OPERATION
10 SpeedScrub2001HD (03–99)
WHILE OPERATING MACHINE
FOR SAFETY: When using machine, go slow on
inclines and slippery surfaces.
WARNING: Flammable materials or reactive
metals can cause explosion or fire. Do not pick
up.
1. Observe amount of solution flow on floor. Adjust
solution control lever to desired flow.
To increase or decrease the maximum solution
flow, turn solution flow adjustment knob located at
rear of machine. Turn knob clockwise to increase
or counterclockwise to decrease maximum
solution flow (
Figure 18
).
FIG. 18
2. Periodically check for foam buildup in recovery
tank
(look through clear lid)
. If excessive foam
buildup begins to develop, pour a recommended
foam control solution into recovery tank.
ATTENTION: Do not allow foam or water to enter
vacuum standpipe, vacuum motor damage will
result. Ball float shut–off will not keep foam out
of standpipe. Vacuum damage due to foam or
water is not covered by warranty.
3. Always operate at a slower speed when scrubbing
around walls or obstacles.
4. Always reduce speed to maintain control when
turning machine.
5. If squeegee leaves streaks, raise and wipe blades
with a cloth. Pre-sweep area to prevent streaking.
6. Overlap each pass by 50mm (2 in).
7. Change or turn over pad when dirty.
8. Stay clear of floor obstructions, such as electrical
plates or grates, they will destroy the pad.
9. During brief stops, you do not have to turn off any
switches, the brush and solution flow will
automatically stop when control grips are
released.
10. Periodically check battery meter discharge level.
When needle drops to the red zone, recharge
batteries.
ATTENTION: Do not continue to run machine
when battery meter needle is in the red zone,
battery damage will result.
11. While cleaning, view clear tube gallon marker for
remaining cleaning solution. Each mark on hose
indicates19 liters (5 gal).
12. When solution tank runs dry, turn off
brush/solution switch, raise brushes and continue
to vacuum until all dirty water is consumed. Then
drain recovery tank
. (See DRAINING TANKS)
.
CIRCUIT BREAKERS
The machine is equipped with (3) circuit breakers to
protect machine from damage.
If circuit breakers should trip, the breakers will not
reset immediately upon tripping. Determine reason
why breaker tripped, allow motor to cool and reset.
Brush motor circuit breaker will trip due to excessive
overload on pad. Reduce pad pressure or replace pad
if breaker should trip. Brush motor circuit breaker is
located near charger plug.
The main (15amp) and drive/vacuum (35amp) circuit
breakers are located at rear of machine (
Figure 19
).
FIG. 19