Nola Kebne 1 User manual

Kebne 1p.
1
/7
Kebne 1 product number Ö72-10
Head office: Nola Industrier AB Box 17701 Repslagargatan 15b
118 93 Stockholm Tel: 08 702 1960 Fax: 08 702 1962 headoffice®nola.se
Customer services/showroom/export/press: Skeppsbron 3 211 20 Malmö
www.nola.se
ASSEMBLY INSTRUCTIONS
2100
OVERVIEW
1400
1462
722
2100

Kebne 1p.
2
/7
Kebne 1 product number Ö72-10
Head office: Nola Industrier AB Box 17701 Repslagargatan 15b
118 93 Stockholm Tel: 08 702 1960 Fax: 08 702 1962 headoffice®nola.se
Customer services/showroom/export/press: Skeppsbron 3 211 20 Malmö
www.nola.se
ASSEMBLY INSTRUCTIONS
PARTS INCLUDED A
C
B B
D
F E
C
G F
X

Kebne 1p.
3
/7
Kebne 1 product number Ö72-10
Head office: Nola Industrier AB Box 17701 Repslagargatan 15b
118 93 Stockholm Tel: 08 702 1960 Fax: 08 702 1962 headoffice®nola.se
Customer services/showroom/export/press: Skeppsbron 3 211 20 Malmö
www.nola.se
ASSEMBLY INSTRUCTIONS
1665
260
30
PARTS INCLUDED
A - 1 pcs
B - 2 pcs
C - 2 pcs
D - 1 pcs
E - 1 pcs
X - 14 pcs
Stop screw M10x30 - 28 pcs
For attaching 20 cm below ground level
Y- 4 pcs
For attaching to the ground
F - 2 pcs Z-4 pcs
1000
1665
1665
1398

Kebne 1p.
4
/7
Kebne 1 product number Ö72-10
Head office: Nola Industrier AB Box 17701 Repslagargatan 15b
118 93 Stockholm Tel: 08 702 1960 Fax: 08 702 1962 headoffice®nola.se
Customer services/showroom/export/press: Skeppsbron 3 211 20 Malmö
www.nola.se
ASSEMBLY INSTRUCTIONS
ASSEMBLY
Install the two end panels BCDF & BCEF using
connecting fitting X. See the principle for
mounting.
Screw on connecting fittings (without tightening
them) in all openings on A and G respectively
Assemble both ends with A and G at the same
time.
Tighten all screws according to the following
principle.
PRINCIPLE FOR ASSEMBLY
1.
A connecting fitting (X)
and two stop screws
M10x30 are needed for
each join.
PLEASE NOTE! THE
SCREWS MUST BE
LUBRICATED!
2.
Screw the connecting
fittings into one part
without tightening the
screw.
3.
Join the parts and
screw in the other
screw.
4.
Ensure that the two
parts are lined up and
then tighten the screws
alternately until the
screw head is in line
with the outer tube. Be
careful not to pull so
hard that the outer tube
is deformed.
A
1.
C
2.
D
B
B
3.
4.
F
E
C
G
F
X

Kebne 1p.
5
/7
c-c 2062
Kebne 1 product number Ö72-10
Head office: Nola Industrier AB Box 17701 Repslagargatan 15b
118 93 Stockholm Tel: 08 702 1960 Fax: 08 702 1962 headoffice®nola.se
Customer services/showroom/export/press: Skeppsbron 3 211 20 Malmö
www.nola.se
ASSEMBLY INSTRUCTIONS
ATTACHMENT 20 CM BELOW GROUND LEVEL
Install the mounting brackets with washer + K6S
M10 x 30 (supplied). Fully tighten the screw. The
pipe should be flattened slightly against the
mounting bracket.
The mounting brackets have a base plate with four holes
for mounting with M16 bolt.
Dig to frost-free depth and base with a non-frosting material.
Use prefab foundation or cast concrete
foundation on site. Drill holes in the
foundation and mount with core
anchor/expander.
Fill with 20 cm of shock absorbing surface. For example,
Bark/gravel/sand
Ground level
Fall protection materials
Foundations
200
c-c 1060

Kebne 1p.
6
/7
c-c 2062
Kebne 1 product number Ö72-10
Head office: Nola Industrier AB Box 17701 Repslagargatan 15b
118 93 Stockholm Tel: 08 702 1960 Fax: 08 702 1962 headoffice®nola.se
Customer services/showroom/export/press: Skeppsbron 3 211 20 Malmö
www.nola.se
ASSEMBLY INSTRUCTIONS
ATTACHING TO THE GROUND
Install the mounting brackets with washer + K6S
M10 x 30 (supplied). Fully tighten the screw. The
pipe should be flattened slightly against the
mounting bracket.
The mounting brackets have a base plate with four holes
for mounting with M10 bolt.
Drill holes in the foundation and mount with core
anchor/expander.
Mounting on wooden base using French wood screw.
c-c 1060

Kebne 1p.
7
/7
Kebne 1 product number Ö72-10
Head office: Nola Industrier AB Box 17701 Repslagargatan 15b
118 93 Stockholm Tel: 08 702 1960 Fax: 08 702 1962 headoffice®nola.se
Customer services/showroom/export/press: Skeppsbron 3 211 20 Malmö
www.nola.se
ASSEMBLY INSTRUCTIONS
SAFETY DISTANCE/FALL PROTECTION
1500 mm Nola recommends a safety distance of 1.5 m from the
outer edge of each unit. Note that the recommended
distance between two units then adds up to 3 m.
Nola also recommends that fall protection is installed
according to Swedish standard SS-EN 16630:2015
“Permanently installed fitness equipment for outdoor
use - Safety requirements and test methods”.
Examples of fall protection can be 20 cm sand,
gravel or bark. A substratum of rubber granules or
grass may also act as fall protection.
Ground level
Foundation
Fall protection materials
200 mm
Table of contents