Line Burner L - Automatic
INSTALLATION AND OPERATION GUIDE
Before operating Bionova burner please read and follow instructions
Conditions of Use
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
1
The BIONOVA Line Burner L –automatic bioethanol fireplace
burner is designed and produced accorded to new DIN 4734-1 standard.
Dangerous goods
Bioethanol fuel is classified as a flammable liquid Class 3, PG II and is regulated
by various standards. Please follow regulations in order to legally and safely
store, handle and use that sort of fuel. Please inform yourself about regulations
in your country.
Contents
ENGLISH
2
Line Burner L Automatic –Installation and Operation Guide
Conditions of use
……………………………………………………
3
Warnings
……………………………………………………
4
Standard equipment received
……………………………………………………
6
Installation
……………………………………………………
7
Connecting, ventilation
……………………………………………………
10
Ventilation, thermal efficiency,
burning time
……………………………………………………
11
How to operate BIONOVA burner
……………………………………………………
12
Maintenance
……………………………………………………
16
Warranty
……………………………………………………
17
Burner data
……………………………………………………
18
Technology
……………………………………………………
19
How to install the IoT environment
properly
……………………………………………………
20
Conditions of Use
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
3
NOVA VIZANTIJA is safety conscious company. We have taken a great care in
designing, manufacturing and assembling your BIONOVA burner to be sure
that it operates safely, efficiently and visually effectively.
To insure that you can enjoy our product for a long time, in comfort, please
operate the product with care and follow these instructions:
1. Before using BIONOVA burner please read manual carefully. This is the
way to use the product safely and efficiently.
Not following instructions could result in property damage, injury or
even death.
2. Keep children away from operating burner or handling it.
3. Please use only specified fuel –bioethanol (>96%Acc). Do not attempt
to use any other flammable fluids (as gasoline for example). BIONOVA
Burner is specifically designed for use with bioethanol and use of any
other fuel would be extremely dangerous.
4. Approval from building authorities may be required. Please contact
appropriate authorities before installing BIONOVA burner.
5. Possession of fire extinguisher - AMMONIUM PHOSPHATE AB:E type,
or appropriate for extinguishing burning ethanol vapors is required.
6. It is a great security asset and it could be tied with insurance issues to
install smoke alarm.
7. Pebbles or other decorative items should not be placed on the burner
top in a way that they detaining normal operation and handling.
If using decorative items, please be sure that they do not:
-Interfere with sliding mechanism
-Emit carbon monoxide
-Fall into opening of the burner in any time
ENGLISH
Warnings
4
Line Burner L Automatic –Installation and Operation Guide
Please honor following warnings:
1. Risk of explosion:
a) NEVER use any other fuel then specified for use with
bioethanol fireplaces ;
b) NEVER fill the fuel when burner operating or still hot ;
c) NEVER fill the fuel in burner reservoir in areas where
flammable vapors or gas may be present ;
d) NEVER store or transport the fuel in other than metal or plastic
container which is:
-Acceptable for use with specific fuel
-Fuel is in the original container
2. Never store fuel in the living space where the fire is situated ;
3. Keep children, pets, clothing, and furniture away. Temperature of
the burner surface can be very high –may cause serious burns ;
4. Never put flammable objects on the burner. Burner surface
becomes intensively hot during burning and stays hot after
burning for a long time.
5. Indoor pollution –BIONOVA burner have to be used in well
ventilated areas –product of bioethanol vapor burning is carbon
dioxide (can be dangerous in high saturations). Persons with
breathing problems should consult physician before installing
BIONOVA burner.
6. Do not use BIONOVA burner as a cooking appliance or throw any
sort of waste materials or paper in burner opening.
7. It is recommended that BIONOVA burner should be fixed into a
position to avoid displacement ;
8. Do not try to disassemble BIONOVA burner ;
9. Do not try to attach any other fuel tank to BIONOVA burner;
10. BIONOVA burner should be used only with authorized accessories
and equipment ;
11. Do not, in any case, obstruct sliding mechanism for
closing/opening ;
Warnings
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
5
12. Do not try to start BIONOVA burner if you suspect fault or any
damage to the housing or mechanism of the burner.
13. The NOVA VIZANTIJA Company does not accept any responsibility
for any damage or injury which accrues if the BIONOVA burner is
used for purposes other than intended; is used incorrectly or
repaired by unqualified persons or has been changed or altered in
any way.
14. BIONOVA burner is not intended to be a sole continues heating
source and to be used longer than 8 hours per session. To avoid
heat expansion and potential spilling please ensure that the burner
is allowed to cool down completely on a regular basis.
15. Using more than one Burner in the same space or a room or with
other appliances that are burning bioethanol please consult with
the manufacturer of the appliances.
16. Minimum safe distance to combustible materials should be 2m.
Please store these warnings in a safe place for future reference
ENGLISH
Standard Equipment Received
6
Line Burner L Automatic –Installation and Operation Guide
The BIONOVA burner is supplied with following standard equipment:
1. BIONOVA Line Burner L Automatic - 1pc.
2. Installation and operation guide - 1pc.
3. Electronic control unit - 1pc.
4. Remote control - 1pc.
Installation
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
7
Please find following installation instructions:
BIONOVA burner is primarily intended for indoor use. For outdoor use please
contact manufacturer or sales personal for specific terms of services.
There are many different variations available for installing BIONOVA burner but
in every case BIONOVA burner must:
-Be installed in non-combustible material only (stainless steel,
concrete, brick, stone) ;
-Insure that burner is positioned on the edges of the upper plate
and that the bottom rests on a leveled surface –this is the only
correct way of positioning.
-It is necessary to provide ventilation openings on the cube in
which the burner is installed in order to ensure even air
circulation and prevent overheating of the burner body and
avoid possible damage to the burner.
-Before installing the burner, the interior of the cube in which the
burner is placed must be cleaned of construction dust and
similar impurities. Building dust can block the operation of the
burner's ventilation system and permanently damage the burner.
-Do not install burner near any gas connections or pipe lines. If
do, please make it safe by a professional prior to burner
installation ;
-Avoid positioning a burner in the area of the room (space) with
cross ventilation or a strong air flow –this could result in
irregular burning and fire hazard.
CORRECT
INCORRECT
ENGLISH
Installation
8
Line Burner L Automatic –Installation and Operation Guide
-Plate on which burner is positioned must be rigid enough to
withstand load of at least 20 Kg.
-Be installed in fixed, leveled and secure position before filling,
lighting and operating ;
-Be installed in position that limits relocation –it is not suitable
for frequent relocation ;
-Be installed in leveled platform ;
-Do not install directly beside wallpaper or laminate or any other
non-fire proof surface or material ;
-Be installed into a setting that has square back –corners can
influence aerodynamics and cause flame to behave irregularly.
As a general guide we recommending:
-Any furniture, items or fittings placed directly above or beside
BIONOVA burner should be suitable for heat tolerance ;
-Heat reflective panels (ideally stainless steel) should be installed
as surrounding and top to assist heat distribution ;
-Glass or mirrored surfaces near BIONOVA burner must be
toughened.
-Closed volumes in the proximity of the burner must be kept
ventilated.
Installation
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
9
Please find required installation dimensions:
705
710
185
190
maximum 20
ENGLISH
Installation
Connecting, ventilation
10
Line Burner L Automatic –Installation and Operation Guide
Connecting:
BIONOVA Line burner L must be connected to the 220V/230V grounded power
supply.
How to connect:
1. Connect cables (1) and (2) from electronic driver unit to burner
terminals (1) and (2)
2. Connect power cable (3) from electronic driver unit to the grounded
power supply (220V/230V).
3. Place the burner and test the functionally.
Ventilation:
When proper fuel is used BIONOVA burner do not need any permanent fixture
or fitting, chimney, gas line, or any utility or supply.
Products of burning bioethanol vapors are CO2, water steam and heat.
Optimum room volume per a burner is 70m3. If used in smaller spaces, please
leave the door of the adjacent rooms or corridor open, or a window slightly
open.
Ventilation, thermal efficiency, burning time
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
11
Minimum room volume
Air exchange (1/h)
Explanation
280m3
0.2
Air exchange due to
leakage in the building
140m3
0.5
Normal air exchange
rate in the leak proof
buildings
70m3
1
Complete air exchange
in installation room
during one hour
Air exchange *(n/h)
Comments
0 –0.5
Windows/doors closed
0.3-1
Window slightly open-no shutters
0.5-1
Window open
* n/h refers to ratio of air circulation in the room –example 0.5/h means that half of the air in
the room is replaced every hour
Efficiency:
BIONOVA burner is efficient since all the heat stays in the room rather than be
wasted to residual emissions.
You may turn burner on and off at any time.
Volume –Burning time:
One full tank will burn up to 6 hours *. You may turn burner on and off at any
time.
* The efficiency data has approximate value depending on the model purchased, weather conditions,
installation point and bioethanol used
ENGLISH
How to operate BIONOVA burner
12
Line Burner L Automatic –Installation and Operation Guide
It is important to follow the procedure described to ensure that you are operating
and using BIONOVA burner safely:
Only fuel to be used in BIONOVA burner is bioethanol fuel –no other fuel is
allowed. Recommended fuel: NOVAFUEL.
All actions with managing bioethanol should be performed in well-ventilated
area and to be sure that all spillage is easily contained and away from any
ignition source.
Volume:
In the center of the burner (inside of perforated area), when you see fuel at the
bottom of the perforated are tank is full –2.95 liters of fuel.
When filling fuel in the tank, the slide mechanism (flap) of the burner must be
open.
Maksimalna količina
goriva
Izbegavati prolivanje goriva
izmedju ploča gorionika i po
površini gorionika
How to operate BIONOVA burner
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
13
Filling the burner:
Before filling the burner with bioethanol fuel please insure following:
1. That the burner is standing in leveled position fixed from moving and
properly installed ;
2. That the burner is not hot from previous use ;
3. That the burner and the sliding mechanism are free from obstacles of
any kind ;
4. Use a tank opening and appropriate funnel to fill up the tank.
5. Keep your hands and face away from the burner at all times during
filling or igniting.
6. If spilling occurs please wipe it dry before any attempt to ignite a
burner.
7. You may use appropriate funnel to avoid spilling.
Open the sliding mechanism (flap) all the way (button A on the remote control)
- the perforated surface is reviled. Charge the burner slowly, without spilling.
You can pour into the tank any amount of fuel (the recommended minimum
quantity is 0.75 liters). Please take care of the fuel level - do not over fill the
tank.
Do not, in any case, over fill the tank - there may be unwanted consequences.
ENGLISH
How to operate BIONOVA burner
14
Line Burner L Automatic –Installation and Operation Guide
Igniting BIONOVA burner:
Keep your hands and face away from BIONOVA burner at all-time especially
when igniting.
Before igniting, make sure that the burner is clear and ready for use.
1. Put slider in full open position, to have enough ventilation for ignition,
by pressing push button (A) on a remote control.
2. From safe distance, (at least 1m) press push button (C) on a remote
control and hold for few seconds. If ignition is not achieved please
press and hold push button (C) again for few seconds. Do not hold
push button (C) for more than 10 seconds continuously.
3. Strong and stable flames will be achieved approximately 1-2 minutes
from the moment of ignition. You may stop burning process at any
time by pressing push button (B) and put out the flame.
How to operate BIONOVA burner
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
15
Turing BIONOVA burner off and restarting:
1. If fuel in the burner tank is not entirely used up it can be used again. In
order to supply more fuel, please wait until burner cools down to room
temperature and then, only then, it is safe to fill burner tank ;
2. When all fuel is used up, there is no need to clean anything, just wait
for the burner to cool down, then refill and restart.
Note: When you see that the flame is small and reduced –in the perforated area
you can see flame only from sides of the burning pit - that means that fuel level
is at absolute minimum.
Reigniting BIONOVA burner:
1. Check if the burner is on room temperature. It takes from 15-30 min.
to cool down depending on how long it has been used before ;
2. Pressing push button (A) on a remote control to open the slider in full
open position ;
3. Allow for any residual fumes to evaporate. It takes few moments ;
4. If needed refill the fuel and reignite by pressing button (C) on a remote
control
DO NOT REFILL:
1. When burner is operating or hot from previous use ;
ENGLISH
Maintenance
16
Line Burner L Automatic –Installation and Operation Guide
Maintenance:
Should be performed when BIONOVA burner is off, completely empty of fuel,
dry and at a room temperature.
The surface of the burner will change color on very hot spots over time. This is
normal “hot stainless steel” ageing process.
1. Use a vacuum cleaner after approximately 50 liters of burned fuel to
clean inside of the burner opening ;
2. Use a mild detergent to clean burner surface. If the surface is highly
stained, apply mild polishing aperient (without abrasives).
3. Do not let the detergent or polishing aperient to get into a burner
opening especially perforated part since it can cause even more
staining and smell during next use.
4. After cleaning, all surfaces should be without any residue and
completely dry.
Warranty
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
17
Warranty terms:
1. Your BIONOVA burner is covered by 2 years warranty from moment of
purchase.
2. Please note - in order to warranty be applied, instructions for installing,
use and maintenance must be followed.
3. Do not try to fix burner by yourself or by unprofessional service and
persons –we do not except responsibility for operating the burner in
these cases.
This warranty certificate along with the invoice or receipt must be presented
when making any claim.
MODEL No.
SERIAL No.
PURCHASER
DISTRIBUTOR
Distributor stamp here
DATE OF PURCHASE
By signing I, upper mentioned purchaser, declare that:
I understand and will follow the terms of use presented in
INSTALATION AND OPERETION GUIDE and taking the full
responsibility for using the product within it.
Understand the terms of warranty.
Purchaser signature: ……………………………………...................................................................
ENGLISH
Burner data
18
Line Burner L Automatic –Installation and Operation Guide
Burner data and dimensions:
Main
material:
Stainless
Steel
( 1.4301)
Evaporator:
Ceramic
fibers
Tank Size:
2,95 l
Weight :
1 kg
Thermal
output :
Up to 3 Kw *
Req. room
volume:
70m3
Burning
Time:
Continuously
Up to 6 h *
* The efficiency data has
approximate value depending on
the model purchased, weather
conditions, installation point and
bioethanol used.
Technology
ENGLISH
Line Burner L Automatic –Installation and Operation Guide
19
EECT –Evaporated Ethanol Combustion Technology
BIONOVA bioethanol fireplace burners are bringing to you unique technology
of ethanol combustion - EECT.
Our burner’s combusting only ethanol vapors distributed from ceramic
evaporator (no loose fuel) trough burning pit calibrated grill providing precise
and odorless process of burning.

Other Nova Vizantija Burner manuals

Nova Vizantija Bionova Round Burner L Operating instructions

Nova Vizantija

Nova Vizantija Bionova Round Burner L Operating instructions

Popular Burner manuals by other brands

Bentone BG 700 Installation and maintenance  instruction

Bentone

Bentone BG 700 Installation and maintenance instruction

Riello Burners Gulliver RG5D Installation, use and maintenance instructions

Riello Burners

Riello Burners Gulliver RG5D Installation, use and maintenance instructions

Enertech Bentone B1FUV Classic Installation and maintenance  instruction

Enertech

Enertech Bentone B1FUV Classic Installation and maintenance instruction

Riello Burners RL 190/M Installation, use and maintenance instructions

Riello Burners

Riello Burners RL 190/M Installation, use and maintenance instructions

Riello RDB2.2 FIREBIRD C20 70K DGT Installation, use and maintenance instructions

Riello

Riello RDB2.2 FIREBIRD C20 70K DGT Installation, use and maintenance instructions

Frigidaire FGIC13P3KS - Portable Induction Cooker uso y cuidado

Frigidaire

Frigidaire FGIC13P3KS - Portable Induction Cooker uso y cuidado

Bentone BG550 Series Installation and maintenance  instruction

Bentone

Bentone BG550 Series Installation and maintenance instruction

Riello COH 180 Installation, use and maintenance instructions

Riello

Riello COH 180 Installation, use and maintenance instructions

MSR WHISPERLITE instructions

MSR

MSR WHISPERLITE instructions

Carlin 201CRD instruction manual

Carlin

Carlin 201CRD instruction manual

Charmglow Gourmet Series owner's manual

Charmglow

Charmglow Gourmet Series owner's manual

Bentone B 30 A2.2H Installation and maintenance  instruction

Bentone

Bentone B 30 A2.2H Installation and maintenance instruction

TENDERFLAME DL180 Installation

TENDERFLAME

TENDERFLAME DL180 Installation

Riello RLS 310/EV O2 MX Modulating operation

Riello

Riello RLS 310/EV O2 MX Modulating operation

Elite Products ESB-301 instruction manual

Elite Products

Elite Products ESB-301 instruction manual

Ecoflam MAIOR P 500.1 PR manual

Ecoflam

Ecoflam MAIOR P 500.1 PR manual

baltur COMIST 23SP Instruction

baltur

baltur COMIST 23SP Instruction

baltur SPARKGAS 30 LX Instruction

baltur

baltur SPARKGAS 30 LX Instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.