Introduction
The cameras are supplied in different configurations. The camera signal output can be supplied as a balanced or unbalanced video signal output. A
balanced video signal makes it possible to use a twisted pair cable for video transmission, while an unbalanced video signal requires a coaxial cable for
video transmission. See the specifications table for the different configurations. The camera is supplied with a 3.6 mm wide-angle lens with an 80°
opening underwater, ideal for coming close to an object in low visibility water. The camera has an indent on the back that can clamp the camera to a
support using a jubilee clip.
Dimensions
Connector layouts:
Installation
The light housing can be fixed to any structure or bracket using a jubilee clip which fits in the groove on the back part of the camera housing or a clamp
bracket. Make sure to connect the power to the correct indicated pins. The power contacts are polarity protected. The video signal contacts are not
protected against external power supply. DO NOT: do not connect a power supply to the video signal contacts.
Maintenance
The stainless steel housing can be cleaned with water and soap and if needed polished with stainless steel polishing materials. The Lexan front glass
can be cleaned with water and soap and only using a cotton cloth or any other non-scratching material. Small scratches on the front glass will not affect
the view underwater. The front glass is locked in the housing with a clip ring in the groove. The clip ring are partially visible at the front of the housing.
Make sure that the clip ring are correct in its place. If not, do not use the camera before the clip ring is well seated or replaced by the factory. Lubricate
the connector pins regular with silicon grease.
WARNING
• It is not allowed to disassemble the system or to repair the product by unqualified personal, this voids all warranties.
• DO NOT: do not use the system if you detect any moisture or water inside.
• DO NOT: do not clean the front glass with paper or other scratching materials.
• DO NOT: do not clean the front glass of Lexan with any liquid containing dissolvent.
CAUTION
• Protect the unit from shock, extreme heat, direct sunlight, and chemical attack.
• The system cannot withstand the impact of heavy objects like air cylinders.
Warranty
The Limited Warranty Period starts at the date of original retail purchase. The Warranty Period is two (2) years for the product. Warranty applies only on
manufacturing defaults. The Warranty Period is one (1) year for accessories, including mounting hardware and connector cables.