Novelan LA Compact Station 1E User manual

Operating Manual
UK
Accessories for
Air/Water heat pumps
Outdoor Installation
LA Compact Station 1E
LA Compact Station 2E
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com

283054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Please read rst
This operating manual provides important information
on the handling of the unit. It is an integral part of the
product and must be stored so that it is accessible in the
immediate vicinity of the unit. It must remain available
throughout the entire service life of the unit. It must be
handed over to subsequent owners or operators of the
unit.
Read the operating manual before working on or opera-
ting the unit. This applies in particular to the chapter on
safety. Always follow all instructions completely and wi-
thout restrictions.
It is possible that this operating manual may contain in-
structions that seem incomprehensible or unclear. In
case of questions or uncertainty, contact the factory cu-
stomer service department or the manufacturer’s local
service partner.
Since this operating manual was written for several dif-
ferent models of the unit, always comply with the para-
meters for the respective model.
This operating manual is intended only for persons as-
signed to work on or operate the unit. Treat all constitu-
ent parts condentially. The information contained he-
rein is protected by copyright. No part of this informa-
tion may be reproduced, transmitted, copied, stored in
electronic data systems or translated into another lan-
guage, either wholly or in part, without the express writ-
ten permission of the manufacturer.
Symbols
The following symbols are used in the operating manu-
al. They have the following meaning:
Information for operators.
Information or instructions for qualied
personnel.
DANGER!
Indicates a direct impending danger resul‑
ting in severe injuries or death.
WARNING!
Indicates a possibly dangerous situation that
could result in severe injuries or death.
CAUTION!
Indicates a possibly dangerous situation that
could result in medium or light injuries.
ATTENTION
Indicates a possibly dangerous situation, which
could result in property damage.
NOTICE.
Emphasized information.
€ENERGY SAVING TIP
Indicates suggestions that help to save energy,
raw materials and costs.
Reference to other sections of the operating
manual.
Reference to other instructions of the manufac-
turer.

383054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Contents
INFORMATION FOR USERS AND QUALIFIED
PERSONNEL
PLEASE READ FIRST.......................................................................2
SYMBOLS..........................................................................................2
INTENDED USE................................................................................4
EXCLUSION OF LIABILITY ............................................................4
SAFETY..............................................................................................4
CUSTOMER SERVICE......................................................................5
WARRANTY / GUARANTEE...........................................................5
DISPOSAL .........................................................................................5
HEAT QUANTITY RECORDING.....................................................5
OPERATION......................................................................................5
CARE OF THE UNIT.........................................................................5
MAINTENANCE OF THE UNIT......................................................6
MALFUNCTIONS.............................................................................6
INSTRUCTIONS FOR QUALIFIED PERSONNEL
SCOPE OF DELIVERY......................................................................6
INSTALLATION AND ASSEMBLY .................................................7
Installation location ................................................................7
Transport to installation location........................................7
Installation.................................................................................7
Components of the unit.........................................................8
Installation / Hydraulic connection
to heating circuit...............................................................9
Safety component .................................................................10
Hydraulic connection of hot water tank ..........................10
Expansion vessels ..................................................................10
ELECTRICAL CONNECTIONS .....................................................10
RINSING, FILLING AND BLEEDING THE SYSTEM..................11
Rinsing, filling and bleeding
the heating and hot water circuits .............................11
Rinsing, filling and bleeding the hot water tank...........13
Bleeding the circulating pump of
the heating circuit...........................................................13
INSULATING THE HYDRAULIC CONNECTIONS ....................13
SET THE OVERFLOW VALVE.......................................................14
INSTALLATION OF THE CONTROL ELEMENT........................14
INSTALLATION AND REMOVAL OF THE SCREEN .................16
COMMISSIONING .........................................................................17
DISMANTLING...............................................................................17
TECHNICAL DATA/ SCOPE OF DELIVERY ...............................18
POWER CURVES
Free compression
Compact Station 1E ...............................................................20
Compact Station 2E...............................................................21
DIMENSIONAL DRAWINGS........................................................22
INSTALLATION PLAN...................................................................23
HYDRAULIC INTEGRATION
with LA 7.1 – LA 18.................................................................24
Legend Hydraulic integration.............................................25
TERMINAL DIAGRAM...................................................................26
CIRCUIT DIAGRAM
Compact Station 1E ...............................................................27
Compact Station 2E...............................................................28

483054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Intended use
The hydraulic tower is an accessory for air/water heat
pumps intended for outdoor installation. Taking into ac-
count the limits of application, the unit can be used in
combination with an outdoor installation air/water heat
pump in new or existing heating systems.
The unit may be used only for the intended use. This
means:
•for heating.
•for heating hot water.
The unit may be operated only within its technical pa-
rameters.
Overview “Technical data/Scope of delivery”
and overview “Technical data/Scope of delivery”
of the operating manual for the heat pump to
which the hydraulic tower is connected.
NOTICE.
Notify the responsible power supply company
of the use of a heat pump or heat pump system.
Exclusion of liability
Der Hersteller haftet nicht für Schäden, die durch nicht-
bestimmungsgemässen Einsatz des Geräts entstehen.
The manufacturer will not be liable for damage resulting
from unauthorized use of the unit.
The manufacturer’s liability will also be voided in the
following cases:
•if work is performed on the unit and its compon-
ents in a manner that does not comply with the
terms of this operating manual;
• if work is performed on the unit and its compon-
ents in an improper manner;
•if work is performed on the unit that is not descri-
bed in this operating manual, and this work was
not expressly approved in writing by the manuf-
acturer;
•if the unit or components in the unit are modi-
ed, redesigned or removed without the express
written permission of the manufacturer.
Safety
The unit is operationally safe when used for the inten-
ded purpose. The construction and design of the unit
conform to the state of the art, all relevant DIN/VDE re-
gulations and all relevant safety regulations.
Every person who performs work on the unit must ha-
ve read and understood the operating manual prior to
starting any work. This also applies if the respective per-
son has already worked with such a unit or a similar unit
or has been trained by the manufacturer.
Every person who performs work on the unit must com-
ply with the applicable accident prevention and safety
regulations. This applies in particular to the wearing of
personal safety gear.
DANGER!
Danger of fatal injury due to electric current!
Electrical connections may be installed only
by qualied electricians.
Before opening the unit, disconnect the
system from the power supply and secure it
from being switched back on!
WARNING!
Only qualied technicians (trained heating,
cooling, refrigerant and electrical techni‑
cians) may perform work on the unit and its
components.
ATTENTION
For safety reasons:
Never disconnect the unit from the power sup-
ply, unless the unit is being opened.

583054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Customer service
For technical information please contact your local
heating engineer or the manufacturer’s local partner.
For a current list and additional partners of the manuf-
acturer, please visit www.novelan.com.
Warranty / Guarantee
For warranty and guarantee conditions, please refer to
the purchase documents.
NOTICE.
Please contact your dealer concerning warran-
ties and guarantees.
Disposal
When decommissioning the unit, always comply with
applicable laws, directives and standards for the recove-
ry, recycling and disposal of materials and components.
“Dismantling”.
Heat quantity recording
In addition to the proof of the unit’s eciency,
EEWaermeGalso meets the demand for a heat quantity
recording (hereafter refered to as HQR). The HQR is
mandatory with air/water heat pumps. With brine/
water and water/water heat pumps, a HQR may only
be set up when a forward ow temperature of ≥ 35 °C
has been reached. The HQR must record the total warm
energy release (heating and hot water) in the building.
In heat pumps with heat quantity recording, the analysis
is conducted by the regulator. The regulator displays
the thermal energy that is exchanged from the heating
system in kWh.
Operation
Your decision to purchase a heat pump or a heat pump
system is a long-term contribution to protecting the en-
vironment through low emissions and reduced primary
energy use.
You can operate and control the heat pump system wi-
th the control element of the heating and heat pump re-
gulator.
NOTICE.
Make sure that the control settings are correct.
Operating manual of the heating and heat
pump regulator.
To ensure that your heat pump or heat pump system
operates eciently and ecologically, the following are
especially important:
€ENERGY SAVING TIP
Avoid unnecessarily high ow temperatures.
A lower ow temperature on the hot water side
increases the eciency of the system.
€ENERGY SAVING TIP
When letting in fresh air, do not leave windows
open for an extended period in order to save
energy and reduce your heating costs.
Care of the unit
The outer surfaces of the unit can be cleaned with a
damp cloth and household cleaning products.
Do not use cleaning or care products that contain ab-
rasives, acids and/or chlorine. Such products would de-
stroy the surfaces and could also damage the technical
components of the unit.

683054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Maintenance of the unit
The components of the heating circuit and the heat
source (valves, expansion vessels, circulating pumps)
should be inspected annually by a qualied technician
(heating or cooling system technician).
The hot water tank should be cleaned once each year
by qualied personnel (heating or cooling system tech-
nicians). To do this, rst empty the hot water tank. Then
remove the Styrofoam guard through the service hole
of the hot water tank. Screw o the ange cover of the
service hole.
Check the safety valve (provided by customer) for the
hot water tank at regular intervals. Since an external
current anode is built in, the anode requires no mainte-
nance.
It is a good idea to have a maintenance contract with
a heating installation company. The company will con-
duct the required maintenance at regular intervals.
Malfunctions
In the event of a malfunction, you can detect the cause
of the malfunction via the diagnostic program of the he-
ating and heat pump regulator.
Operating manual of the heating and heat
pump regulator.
ATTENTION
Service and repair work on the components of
the unit may be performed only by customer
service personnel authorized by the manufac-
turer.
Note that no fault is displayed if the safety temperature
limiter has triggered at the heating element (depends
on device).
Scope of delivery
Example of scope of delivery:
1 Compact unit (hot water tank and
buer tank, without heat pump)
2 Extra box with control element
of the heating and heat pump
regulator, safety component
for heating circuit, outdoor
temperature sensor, feet
3 Expansion vessel for heat circuit
Inspect delivery for outwardly visible signs of da-
mage…
Check to make sure that delivery is complete.
Any defects or incorrect deliveries must be claimed
immediately..
NOTICE.
Note the model.
Overview “Technical data/scope of delivery” or
rating plate on unit.

7
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Installation and assembly
Observe the following when performing all work:
NOTICE.
Always comply with applicable accident pre-
vention regulations, statutory regulations, ordi-
nances and directives.
INSTALLATION LOCATION
ATTENTION
Install the unit only indoors.
The installation area must be frost-free and dry. It must
fulll applicable local regulations.
Dimensional drawing and installation plan for
respective unit model.
TRANSPORT TO INSTALLATION LOCATION
To avoid damage during transport, you should trans-
port the unit to the nal installation location in its ori-
ginal packaging (with angle bracket on the wooden pal-
let), using a lifting truck.
CAUTION!
Several people are required to transport the
unit. Do not underestimate the weight of the
unit.
Overview “Technical data/scope of delivery”,
“General unit data” section.
CAUTION!
Unit is not fastened to the wooden pallet.
The unit can tip when being lifted down and
during transport with a lifting truck. This
can result in personal injury and damage to
the unit.
– Take suitable precautionary measures to
eliminate the danger of tipping.
If it is not possible to transport the unit to the nal in-
stallation location using a lifting truck, you can also
transport the unit using a hand truck.
ATTENTION
Never use components and hydraulic connec-
tions on the unit for purposes of transport.
ATTENTION
Do not damage the components and hydraulic
connections under any circumstances.
DANGER!
The strap attached to the back of the unit is
an aid for tipping the unit onto a hand truck!
Always secure the unit on the hand truck wi‑
th a tension belt!
Do not lift or transport the unit using only
the strap!
– The strap could break
– Persons could be injured
– Persons beneath the load could be fatally
injured
– The unit and other objects could be da‑
maged!
CAUTION!
Wear safety gloves.
INSTALLATION
CAUTION!
Several people are required to install the
unit. Do not underestimate the weight of the
unit.
Proceed as follows at the installation location:
Set unit on a solid and level, preferably sound-insu-
lated surface…
Mount feet…
ATTENTION
Moving the unit without the feet mounted can
damage the oor.

883054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
•
Tip the unit slowly and carefully to one side…
Secure unit in raised position so that it cannot acci-
dentally tip back into the original position.
CAUTION!
Hands and ngers could be crushed during
the following tasks!
•
Mount one foot each on the front and back of the
unit…
1 Foot
2 Lock nut
3 Adjusting screw
•
Slowly and carefully tip the unit back into the origi-
nal position…
•
Repeat procedure on the other side of the unit…
Attach side panels and position unit at nal loca-
tion. Compensate for minor unevenness using the
four adjusting screws. Then tighten the lock nuts.
COMPONENTS OF THE UNIT
1 Safety component for
heating circuit (insulated)
2 Hot water temperature sensor
3 External current anode
for hot water tank
4 Hot-water tank
5 Overow valve
6 Circulating pump for
heating circuit (HUP)
7 Switching valve for hot water
8 Fill/empty cock for heating circuit
9 Adjustable feet
10 Capability for installation of
an electric heating element
(heating element not included
in delivery; heating element for
buer tank up to max. 1 x EHZ 60)
11 Buer tank
12 Option for installation of an
electric heating element
(heating element not included in
delivery; heating element for hot
water tank up to max. 1 x EHZ 45F)
13 Electrical switch cabinet

9
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
INSTALLATION / HYDRAULIC CONNECTION
TO HEATING CIRCUIT
The connections for the heating circuit, for the cold and
hot water and for the circulation are located on the back
of the unit. The connection for the safety component of
the heating circuit is on the top of the unit:
1 Safety component for
heating circuit
2 Hot water
3 Hot water inow (return ow)
4 Hot water outow (forward ow)
5 Circulation
6 Cold water
7 Heating water outow
(to heat pump)
8 Heating water inow
(from heat pump)
NOTICE.
Dimension heating system so that the free com-
pression of the circulating pumps integrated in
the unit always ensures the minimum heating
water ow rate.
Always take into account the connecting lines
between the heat pump and the hydraulic tower.
ATTENTION.
Install hot water connections to the heat pump
based on the specications of the heat pump
guide below frost penetration depth.
Heat pump guide.
Remove front panel of unit. To do this, loosen
quick-release screws on the front panel. Turn coun-
ter-clockwise 90°…
Lift front panel and set aside in a safe place…
ATTENTION
When installing the connections, always secure
the connections on the unit from twisting, in or-
der to prevent damage to the copper pipes in
the interior of the unit.
Rinse heating circuit thoroughly prior to connec-
ting the unit to the heating circuit…
NOTICE.
Contamination and deposits in the heating cir-
cuit can cause malfunctions.
Install shut-o devices for the hot water outow
(forward ow) and hot water inow (return ow) on
the heat pump side.
Hydraulic connection instructions‘.
Install ll/empty devices, shuto valves and non-re-
turn valves at the required locations in the heating
circuit.

10 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Electrical connections
Observe the following when performing all work:
DANGER!
Danger of fatal injury due to electric current!
Electrical connections may be installed only
by qualied electricians.
Before opening the unit, disconnect the
system from the power supply and secure it
from being switched back on!
WARNING!
Observe the relevant EN‑, VDE and/or
applicable local safety regulations during
the installation and during all electrical
work.
Comply with technical connection
requirements of the responsible power
supply company (if required by the latter)!
NOTICE.
All live wires must be stripped before they are
installed in the cable duct of the switch cabi-
nets!
Remove right side panel of unit, if necessary.…
Transport to installation location.
Open switch cabinet in unit…
To do this, only loosen the two upper screws of the
cover plate. Remove the remaining screws. Remove
cover plate….
Insert control and sensor wires and the wire for the
power company blocking contactor through the
bushings on the back of the unit. Guide wires via
the cable duct to the terminals in the switch cabi-
net…
Follow specications of the terminal diagram for
electrical connections…
“Terminal diagram” for respective model.
SAFETY COMPONENT
The safety component for the heating circuit is in the
extra box.
Mount the safety component on the connection provi-
ded on the top of the unit.
The safety drain of the safety valve must lead into the
drain via a funnel siphon in accordance with the applica-
ble standards and regulations!
HYDRAULIC CONNECTION OF HOT WATER TANK
Connect hot water tank according to DIN 1988 and DIN
4753, Part 1 (or the local applicable standards and direc-
tives).
Do not exceed the operating pressures specied on the
rating plate. Install a pressure reducer, if necessary.
ATTENTION
The electrical conductivity of the hot water out-
ow must be > 100 µS/cm and must be compa-
rable to water that is suitable for drinking.
EXPANSION VESSELS
The expansion vessel for the heating circuit, the corre-
sponding cap valve and the wall mount are included in
the scope of delivery. They must be integrated in the he-
ating circuit on-site in compliance with the applicable
standards and directives.
We recommend installing a suitable expansion vessel
(not included in delivery) in the hot water circuit. This
equalizes pressure uctuations or water shocks in the
cold water network and prevents unnecessary loss of
water.

11
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
1 Connection for control voltage
2 Electrical switch cabinet
E
D
C
B
www.alpha-innotec.de
D - 95359 Kasendorf
Industriestraße 3
Alpha-InnoTec GmbH
1
1
Ers. d.
Ers. f.
Benennung
Durchusssensor VFS5-100
603772
-
Zust. Änderungstext Datum
9.2.2009 HS
Von
Blatt
von
Werksto Gewicht
-
Maßstab
1:2
Det. Maßstab
Datum Name
Erstellt
Gepr.
Norm.
9.2.2009 Stenglein
toleranz
Allgemein-
DIN ISO 2768 -c
Oberächen
ArtikelNr.
---
1 2 3 4
Schutzvermerk nach DIN 34 beachten
Blattformat: A4 hoch
ATTENTION
The sensor cable for heat quantity recording
may not be shortened!
NOTICE.
The control element of the heat and heat pump
regulator can be a connection with a computer
or network using an network cable designed for
such pruposes, thus allowing the heating and
heat pump regulator to be controlled remotely.
If such a connection is desired, install a scree-
ned network cable (category 6, with RJ-45 plug)
through the unit when installing the connec-
tions and run it through the front facade of the
unit, parallel to the already-present heating and
heat pump regulator control cable.
NOTICE.
If electric heating elements are installed, you are
responsible for the fuse protection of these.
After completion of all electrical installation work,
close the switch cabinet inside the unit…
Close the unit if no further installation work inside
the unit is to be performed immediately.
Rinsing, lling and bleeding the
system
ATTENTION
The system must be absolutely free from air be-
fore commissioning.
Contamination and deposits in the system can cause
malfunctions.
RINSING, FILLING AND BLEEDING
THE HEATING AND HOT WATER CIRCUITS
ATTENTION
Do not exceed a pressure of 2.5 bar when rin-
sing the unit. The drain line of the heating cir-
cuit safety valve must be closed before rinsing
and lling.
ATTENTION
Before rinsing and lling the hot water tank,
the drain pipe of the safety valve must be con-
nected.
COMPACT STATION 1E
Connect hose for water outlet to lling and em-
ptying tap (provided by customer) between he-
at pump and compact station (heating water inlet
from heat pump) and lead to a drain…
„Dimensional drawings“
Connect hose for water inlet to lling and emptying
tap (provided by customer) between heat pump
and compact station (heating water outlet to heat
pump)…
„Dimensional drawings“

12 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Close shut-o valves (provided by customer) to he-
at pump! Open shut-o valves (provided by custo-
mer) to compact station…
Remove the motor of the 3-way valve. To do so, re-
move the U-bolt on the motor base and CAREFULLY
pull the motor upward…
Turn spindle 180° and rinse hot water circuit ca. 1
minute…
Turn spindle 180° back to starting position (roun-
ded side of spindle points to B)…
Rinse heating circuit! If necessary, heating and hot
water circuit can be rinsed at the same time! To do
so, turn spindle 30°…
After completion of the rinsing and lling procedu-
re, move spindle to starting position and mount the
motor of the 3-way valve…
NOTICE.
To ensure a good seat of the motor on the valve,
make sure that the U-bolt with the reduction is
not pushed past the lug, because then the mo-
tor will not be held securely on the valve!
In order to be supported securely, the U-bolt must bear
with both ends against the lug:
The unit is bled automatically when the bleeders
(black cap) of the safety component of the hea-
ting circuit and the bleeders on the inlet to the ex-
changer of the hot water tank are open. If the hea-
ting circuit is lled or emptied, the bleeding valves
open…
Open shut-o valves (provided by customer) to he-
at pump! Close shut-o valves (provided by custo-
mer) to hydraulic tower…
Exchange hoses at lling and emptying taps and
rinse condenser of the heat pump via return ow…
In addition, open the bleeding valve on the con-
denser of the heat pump. Bleed condenser and
then close the bleeding valve after completion of
bleeding.
HYDRAULIC TOWER 2
Follow the instructions from to compact stati-
on 1E…
NOTICE.
When delivered, the valve is set to hot water.

13
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
BLEEDING THE CIRCULATING PUMP OF
THE HEATING CIRCUIT
Loosen the screw-on cap in the middle of the circulating
pump for the heating circuit.
Insulating the hydraulic
connections
You must insulate the pipes of the heating circuit, the
connecting lines between the compact station and the
heat pump and the connections for the hot water tank.
NOTICE.
Insulate in accordance with applicable local
standards and directives.
3-way valve
1 button
2 adjusting lever
Rinse hot water circuit for ca. 1 minute…
Press button on motor of 3-way valve and simulta-
neously turn adjusting lever 90°…
Rinse heating circuit! If necessary, heating and hot
water circuit can be rinsed at the same time! To do
so, press button on motor of 3-way valve and simul-
taneously turn adjusting lever 45°…
After completion of the rinsing and lling procedu-
re, move adjusting lever of motor to starting positi-
on…
Follow the instructions from to for hydraulic
tower 1.
RINSING, FILLING AND BLEEDING THE HOT WATER
TANK
ATTENTION!
Before rinsing and lling the hot water tank,
the drain pipe of the safety valve must be con-
nected. Do not exceed the response pressure of
the safety valve.
Open valve for cold water inlet on the hot water
tank…
Open the hot water valves at the taps…
Rinse the hot water tank until air no longer emerges
from the valves at the taps…
Close hot water valves at the taps.

14 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Set the overow valve
REMARQUE
The activities in this section are only necessary
for in-line tank integration.
Complete the worksteps quickly, otherwise the
maximum return temperature can be exceeded
and the heat pump switches to high-pressure
fault.
Turn the adjusting knob at the overow valve to
the right to increase the temperature dierence
(the temperature drop), turn it to the left to re-
duce it.
System is running in heating mode (ideally in cold
condition).
In case of low heating curve: Set the system to
“Forced heating”…
Operating manual of the heating and heat
pump controller.
Shut o valves to the heating circuit…
Ensure that the total ow is routed via the overow
valve…
Read out the ow and return temperature at the
heating and heat pump controller…
Operating manual of the heating and heat
pump controller.
Turn the adjusting knob (1) of the overow valve (2)
until the temperature drop between the ow and
return temperature is set as follows:
External temperature Recommended settings
-10 °C 4 K
0 °C 5 K
10 °C 8 K
20 °C 9 K
30 °C 10 K
Open valves to heating circuit…
Reset the heating and heat pump controller.
Installation of the control
element
Situated at dierent heights in the front facade of the
unit are recesses (each with 4 recesses) for fastening the
control element:
1 four upper recesses
2 four lower recesses
4 hooks are located on the back side of the control
element and can be used to hang the control element
on the front facade of the unit:

15
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Hang the control element’s hooks on the recesses
of the front facade (either in the upper or lower
recesses)…
Example:
Control element in upper recesses
Push the control element down until it locks into
position…
Stick the heating and heat pump regulator’s control
cable into the right bushing on the bottom of the
control element…
NOTICE.
A connection to a computer or a network can be
installed via the left bushing on the bottom of
the control element, thus allowing the heating
and heat pump regulator to be controlled remo-
tely. One pre-condition is that a screened net-
work cable (category 6) be installed through the
unit when installing the unit.
Operating manual for the heating and heat
pump regulator, version “Qualied technician”,
“Web server” section.
If this network cable is available, insert the net-
work cable’s RJ-45 plug into the left bushing of
the control element.
NOTICE.
The network cable can be exchanged at any
time. In order to be able to connect it, the screen
must rst be removed.

16 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Installation and removal of the
screen
INSTALLING THE SCREEN
NOTICE.
The screen is provided at the time of delivery so
that the control element may be inserted in the
upper recesses of the front facade.
If the control element has been inserted in the
lower recesses of the front facade, you must rst
remove the screen’s temporary cover and then
reinsert it above the logo.
Screen at time of delivery:
1 recess for control element
2 logo
3 temporary cover
First, insert the screen below, in the provided slots
on the front of the facade…
Beginning rst on one side and moving upwards,
lock the screen’s snap-in lugs in place in the slots
provided on the front of the facade…
Next, on the opposite side, moving upwards.
Lock the screen’s snap-in lugs in place in the slots
provided on the front of the facade…
Finally, press the screen’s upper snap-in lugs into
the slots provided on the front of the facade.
REMOVING THE SCREEN
In order to remove the screen, the snap-in lugs must
rst be loosened by pressing one side completely
toward the middle of the screen. Thereafter, remove
the snap-in lugs from the opposite side.

17
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Dismantling
DANGER!
Danger of fatal injury due to electric current!
Electrical connections may be installed only
by qualied electricians.
Before opening the unit, disconnect the
system from the power supply and secure it
from being switched back on!
WARNING!
Only qualied heating or cooling system
technicians are allowed to remove the unit
from the system.
ATTENTION
Recycle or provide for proper disposal of unit
components in accordance with the applicable
regulations, standards and directives.
REMOVAL OF THE BUFFER BATTERY
ATTENTION
Before scrapping the heating and heat pump re-
gulator, remove the buer battery on the pro-
cessor board. The battery can be pushed out
using a screwdriver. Dispose of battery and elec-
tronic components in keeping with environ-
mental considerations.
Commissioning
Follow the instructions in the section entitled
“Commissioning” in the operating manual for
your heat pump.
Make sure of the following…
•The water supply to the hot water tank must be
open.
•The hot water tank must be lled.
If the heat pump is switched on with an empty
tank, the control element will indicate a malfunc-
tion.
Operating manual of the heating and heat
pump regulator.

18 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Accessory for heat pump model LA 7 – LA 8 ı LA 10 – LA 18 • applicable ı — not applicable
Installation location Indoors ı Outdoors • applicable ı — not applicable
Conformity CE
Heating circuit Free compression heat circuit pump ∆p ı volume flow bar ı l/h
max. permissible operating pressure bar
Volume of buffer tank l
3-way valve, heating/hot water integrated: • yes — no
Hot‑water tank Rated volume l
permissible operating pressure bar
Surface heat exchanger heat pump m²
General unit data Dimensions (see dimensional drawings for the specified unit size) unit size
Total weight kg
Connections Heating circuit ...
Cold water ...
hot water ...
Circulation ...
Electric Voltage code ı circuit breaker control voltage *) ... ı A
effective power input of heating/hot water circuit pump kW
Protection type IP
Safety equipment Safety component heating circuit ı Safety component heat source Incl. in sc. of delivery: • yes — no
Heating and heat pump regulator Incl. in sc. of delivery: • yes — no
Expansion vessels Heating circuit: Scope of delivery ı Volume ı Initial pressure • yes — no ı l ı bar
Overflow valve integrated: • yes — no
Factory setting (adjust when commissioning the system) bar
Sound Sound pressure level in free field/sound conducting level dB(A) ı dB(A)
UK813300L
*) comply with local regulations
Technical data/scope of delivery

19
83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Accessory for heat pump model LA 7 – LA 8 ı LA 10 – LA 18 • applicable ı — not applicable
Installation location Indoors ı Outdoors • applicable ı — not applicable
Conformity CE
Heating circuit Free compression heat circuit pump ∆p ı volume flow bar ı l/h
max. permissible operating pressure bar
Volume of buffer tank l
3-way valve, heating/hot water integrated: • yes — no
Hot‑water tank Rated volume l
permissible operating pressure bar
Surface heat exchanger heat pump m²
General unit data Dimensions (see dimensional drawings for the specified unit size) unit size
Total weight kg
Connections Heating circuit ...
Cold water ...
hot water ...
Circulation ...
Electric Voltage code ı circuit breaker control voltage *) ... ı A
effective power input of heating/hot water circuit pump kW
Protection type IP
Safety equipment Safety component heating circuit ı Safety component heat source Incl. in sc. of delivery: • yes — no
Heating and heat pump regulator Incl. in sc. of delivery: • yes — no
Expansion vessels Heating circuit: Scope of delivery ı Volume ı Initial pressure • yes — no ı l ı bar
Overflow valve integrated: • yes — no
Factory setting (adjust when commissioning the system) bar
Sound Sound pressure level in free field/sound conducting level dB(A) ı dB(A)
UK813300L
*) comply with local regulations
Compact Station 1E
• ı —
• ı —
•
0,70 ı 1000
3
98
•
295
10
2
1
290
R 1“
R 1“
R 1“
RP ¾“
1~N/PE/230V/50Hz ı B10
0,07
20
• ı —
•
• ı 25 ı 1,5
•
0,3
35 / 49
813300a
Compact Station 2E
— ı •
• ı —
•
0,52 ı 2000
3
98
•
285
10
3,5
1
290
R 1¼“
R 1“
R 1“
RP ¾“
1~N/PE/230V/50Hz ı B10
0,09
20
• ı —
•
• ı 50 ı 1,5
•
0,5
35 / 49
813301d

20 83054003dUK – Translation into English of the original German operating manual – Subject to change without notice. www.novelan.com
Bezeichnung:
Freie Pressung
Seite: 1/1
HT 1
Zeichnungsnummer: 812022
Datei: 812022b Externe Pressung HT 1
- / PEP 021-2006 / Stannow / 22.06.07
a/ÄM 0072-2015/Liska/25.01.2015
b/ÄM 001-2016/Liska/25.02.2016
Änd./ÄM/Ersteller/Datum
0,0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5
Δp (bar)
VHW (m³/h)
Legend: UK812022
“” Volume ow, heating water
∆p (bar) Free compression, heating circuit
Compact Station 1E Free compression
This manual suits for next models
1
Table of contents
Other Novelan Heat Pump manuals
Popular Heat Pump manuals by other brands

Trane
Trane RTXC XE Series Installation operation & maintenance

Atlantic
Atlantic alfea extensa duo+ Installation and operating manual

hydro-s
hydro-s Inverter 6 User and service manual

Heat Controller
Heat Controller HBH Series Installation, operation & maintenance manual

Vaillant
Vaillant 0020180635 System Installation Instructions

Immergas
Immergas MAGIS COMBO PLUS V2 Series INSTRUCTIONS AND RECOMMENDATIONS FOR THE INSTALLER