TABLE OF CONTENTc2Configuration
Tabel of contents
1 About this manual 7
Text conventions 7
Additional technical documentation 8
2 General information 9
The vending machine interfaces 9
The user interfaces 9
When to use the HENRI service tool? 9
Connecting HENRI 10
3 Presettings 11
Selecting menu language 11
Setting display contrast (only c2blue) 12
Specifying display message for operating mode (only c2blue) 13
4 Settings for filling and emptying cassette 14
Which settings should be done? 14
Settings for tube refilling by coin insertion 14
Settings for direct refilling the removed cassette 14
Configuring float levels 15
Specifying float level per tube 15
Activating/deactivating float-up function 16
Setting tube counters to float levels automatically 17
Correcting tube counters according to filling level sensors 18
Resetting tube counters before fill-up 19
Redirecting cash-box coins to return area 20
Reporting inserted coins to machine (only c2MDB) 21
Disabling/enabling inventory keys / disabling/enabling inventory
keys using MDB/BDV protocol (only c2blue/green) 22

4
TABLE OF CONTENTS c2Configuration
5 Prices and vending modes
(only c2BDV/Executive) 23
Price holding in the coin changer 23
Setting prices 24
Activating coin changer price holding 25
Displaying price 26
Configuring "Committed to vend" or change return at any time 27
Configuring single or multi vend 28
Resetting or storing credit which cannot be paid out 29
6 Cash acceptance 30
Limiting acceptance of coins and banknotes
(only c2BDV/Executive) 31
Limiting acceptance of tube coins (filling level limitation) 32
Inhibiting coins 33
Inhibiting high-value coins if there is not enough change
(only c2BDV/Executive) 34
Optimising acceptance of genuine coins/rejection of fraud coins
(defining acceptance tolerances) 35
Selecting coin group A or B 36
Preventing coins from getting stuck in the tubes 38
Configuring security stock for each tube 38
Transmitting tube filling level incl. security stock to VMC
(only c2MDB) 39
Enabling VMC to payout security stock with DISPENSE
(only c2MDB) 39
7 Change payout 40
Reassigning coin cassette 40
Reporting more than 255 coins of the same payout
denomination to VMC (only c2MDB) 42
Limiting change return (only c2BDV/Executive) 43
Configuring conditions for tube empty message 44
Activating low-power single-motor payout 46

5
TABLE OF CONTENTc2Configuration
Activating change machine mode (small coins first) 47
8-way c² spider payout (only c2MDB) 48
Assigning the c² spider cash box/hopper coins (only c2MDB) 48
Inverting assignment of hopper and spider sorter chute
(only c² MDB) 49
8 Peripheral 50
Hopper settings 50
Setting hopper coins 51
Setting up communication with hopper(s) 52
Making hopper coins to be paid out first 53
Disabling/Enabling hopper empty and/or full detection 54
Recycler settings 55
Setting up communication with recycler 55
Inhibiting high-value banknotes depending on change stock
(only c2MDB) 57
Paying out all banknotes
(compensating the machine‘s security stock) (only c2MDB) 58
Bill validator settings (only c2BDV/Executive) 59
Setting up communication with MDB bill validator 59
Inhibiting/releasing banknote acceptance depending on
change stock or card payments 60
Activating/deactivating escrow function 61
Card reader settings (only c2BDV/Executive) 62
Setting up communication with MDB/BDV card reader 62
Activating second price list for card transactions 63
Limiting debit card recharging
(only for BDV/MDB card readers) 64
Setting up communication with external audit unit
(only c2BDV/Executive) 65

6
TABLE OF CONTENTS c2Configuration
9 Audit (option) 66
Setting vending machine number 66
Setting date and time 68
Specifying data to be printed 69
Setting output device 70
Selecting printing format 70
Selecting type of output device 71
Activating maximum IrDA readout speed
(only c2with IrDA interface on coin validator) 72
Activating Bluetooth audit (only c2with Bluetooth module) 73
10 Basic settings 74
Changing smallest coin value (base value) 74
Changing decimal point position (only c2MDB) 76
Configuring alternative coin value for second currency or
as token value 77
Changing currency/calling code (only c2MDB) 78
Changing MDB level (only c2MDB) 79
Selecting mains operation or battery operation (only c2MDB) 80
Configuring wake-up time (only c2MDB) 81
Providing coin changer configuration with write protection for
BDV machines (only c2BDV) 82
11 Batch configuration 83
Configuring coin changer master 83
Storing desired configuration in HENRI 84
Transferring desired configuration to coin changers 84
Adapting individual settings 85
12 Index 86

7
ABOUT THIS MANUALc2Configuration
1 About this manual
This manual describes how to set the c2concerning:
• Language and display (Presettings)
• Coin cassette filling and emptying
• Prices and vending modes
• Cash acceptance
• Change payout
• Peripherals
• Audit
This manual does not describe the whole functional range of the
coin changer currenza c2or HENRI service tool. In order to be able
to use the whole functional range of the devices safely as well as
toconfigureallpossiblefunctions,allmanualsandshortreference
guidesfortheNRIchangercurrenzac2andHENRIservicetoolmust
be read carefully (PDF download at www.cranepi.com, NRISupport).
Text conventions
Tomakeiteasierforyoutonavigatewithintheseinstructionsandtooperate
the devices, the following accentuations were made in the text:
Safety instructions, which you must observe in order to protect
operators and equipment.
Notes,whichyoumustobserveinordertoprotecttheenvironment.
Special notes, which are to facilitate the use of the devices.
At the beginning of a chapter you will find a short "guide", which
summarises the content of the chapter.
1 2 3 ... Requests to perform an action are numbered in another typeface
and, if possible, listed in a table.
DISPLAY TEXTS are set in small capitals.
BUTTONS and MENU ITEMS are shown in bold capitals.

8
ABOUT THE MANUAL c2Configuration
Additional technical documentation
Apart from the manual you already have, there is further documentation
for the currenza c2and HENRI service tool, e.g. about service work and
technical data. All product descriptions are available as PDF at www.
cranepi.com, NRI Support.

9
c2Configuration GENERAL INFORMATION
2 General information
In order to keep the manual as short as possible, this chapter provides
you with all general information, which will not be repeated in the following
chapters (e.g., connecting the HENRI service tool).
The vending machine interfaces
This manual refers to the configuration of all currenza c2models. The
models have different configuration options, e.g., due to different vending
machine interfaces.
The chapter title supplement put in brackets limits a certain function or
setting for one or several interfaces.
The user interfaces
Beyondthatthecurrenzac2modelsdifferintheiruserinterface.Thec2blue
is the only model with a user interface allowing a direct configuration at the
coinchanger.Allothermodels(green,orange,white)mustbeconnectedto
the HENRI service tool for configuration, that cannot be carried out using
the switch block on the rear of the coin validator.
When to use the HENRI service tool?
• To configure the c2green/orange/white
• To configure a second currency/special token values in the c2blue/
green/orange/white
• As data transfer unit for e.g. current configuration and firmware files,
which are supposed to be loaded into a c2blue/green/orange/white

10
c2Configuration
GENERAL INFORMATION
Connecting HENRI
In the HENRI short reference guide you learn how to connect the
HENRI service tool to the currenza c2with full details. At this point
you will only find a short description for on-site configurations.
Plug the RJ-45 connector of the HENRI connecting cable into the top right
socket of the coin changer.
HENRI is powered by the vending machine, switches over to the c² mode
automaticallyandshowsthe(vendingmachine)displayinnormaloperating
mode, e.g., the current change stock.
InthefollowingchaptersithasbeenassumedthatHENRIneedstobe
connectedtothecoinchangersc2green/orange/whiteforconfiguration
and shall not be explained again.
Fig. 1: Connecting HENRI

11
c2Configuration PRESETTINGS
3 Presettings
This chapter describes settings which are not concerned with the coin
changer operation itself but must be carried out once before configuring
the coin changer, if not set at Crane Payment Innovations, Buxtehude:
• Menu language
• Display contrast
• Display message
Selecting menu language
There are four different language packages for the c² menu language:
1. English, German, French, Spanish, Italian
2. English, German, French, Spanish, Dutch
3. English, Polish, Czech, Slovak, Hungarian
4. English, German, French, Turkish, Romanian
When delivered, the coin changer language package has been installed
according to the customer’s requirement.
To select the menu language desired from the package (also for audit
receipts):
Quick approach:
= Main menu > E = Settings > Other settings > Language
Press key ... How often? Effect
11 x You enter the main menu
21 x You enter the SETTING menu
3until Other settings You want to enter submenu OTHER
SETTINGS
41 x You enter the submenu
51 x You want to set the menu LANGUAGE
61 x Now you can set the LANGUAGE
7/until language desired You want to set this language
81 x You lock the language selected in
memory
91 x/2 x You return to main menu/operating
mode

12
c2Configuration
PRESETTINGS
Setting display contrast (only c2blue)
The contrast of the c2blue display has a default setting of "46".
To change the contrast:
Quick approach:
= Main menu > E = Settings > Other settings > Display contrast
Press key ... How often? Effect
11 x You enter the main menu
21 x You enter the SETTING menu
3until Other settings You want to enter submenu OTHER
SETTINGS
41 x You enter the submenu
5until Display contrast You want to set the DISPLAY CONTRAST
61 x Now you can set the CONTRAST
7/until required digit You highlight the digit to be changed
8/until required value This value is to be set (the contrast is
changing with the value set)
9Please repeat steps 7 and 8 to set the second digit of the contrast value, if necessary
10 1 x You lock the set value in memory. The
display has the new contrast
11 1 x/2 x You return to main menu/operating
mode

13
c2Configuration PRESETTINGS
Specifying display message for operating mode (only c2blue)
During normal operating mode the currenza c² blue may
display one of the following messages:
• Total CHANGE stock in coin cassette
• CASHBOX stock and total change stock in coin cassette
by turns
• Totalchangestockandcoinnumberpertube(INVENTORY)
To specify the display message:
Quick approach:
= Main menu > E = Settings > Other settings > Display
Press key ... How often? Effect
11 x You enter the main menu
21 x You enter the SETTING menu
3until Other settings You want to enter submenu OTHER
SETTINGS
41 x You enter the submenu
5until Display You want to set the DISPLAY message
for normal operating mode
61 x Now you can select the DISPLAY
message
7/until required message You want to set this message
81 x You lock the message selected in
memory
91 x/2 x You return to main menu/operating
mode
9OK
67.85
Change
9OK
46.13
Cashbox
Inventory:
EUR
010.20
000 000
008 000 048 025

14
c2Configuration
SETTINGS FOR FILLING AND EMPTYING CASSETTE
4 Settings for filling and emptying cassette
Thischapterdescribesuseful or required settings for refilling andemptying
the coin cassette:
• Configuring float level
• Setting tube counters to float-level automatically
• Correcting tube counters according to filling level sensors
• Resetting tube counters before refilling cassette
• Redirecting cash-box coins to return area
• Reporting inserted coins to machine (only c2MDB)
• Disabling/enabling inventory keys / disabling/enabling inventory keys
using MDB/BDV protocol
Which settings should be done?
Toenablethecoinchangertoregistertheexactcoinnumberwerecommend
the following settings depending on the filling method used:
Settings for tube refilling by coin insertion
If the cassette is refilled by inserting the tube coins (and without emptying
the cassette completely beforehand), see that the tube counters are not
correctedaccordingtothefillinglevelsensorsautomatically,astheinserted
coins will be registered exactly in the tube filling mode.
Whereas,ifyouremoveandcompletelyemptythecassettebeforeinserting
the tube coins, you should set the following in order to reset the tube
counters before refilling the cassette:
• Resetting the tube counters before refilling the cassette
• Correcting tube counters according to filling level sensors automatically
Settings for direct refilling the removed cassette
If the cassette is removed to be directly refilled with a certain number of coins
per tube,i.e. countedcoins, the coinchanger mustbe setas followsto ensure
the exact registration of the coin number:
• Configuration of the coin number as float level per tube
• Automatic tube counter setting to float levels
• Deactivation of the automatic tube counter correction according to filling
level sensors
If the cassette is removed to be directly refilled with any number of coins, the
tubecountersmustbecorrectedaccordingtofillinglevelsensorsautomatically.

15
c2Configuration SETTINGS FOR FILLING AND EMPTYING CASSETTE
Configuring float levels
Should you wish the service personal to always fill or empty the tubes at
a filling level of a certain and always identical coin number, it is advisable
to configure so-called float levels.
First of all specify a number of coins for each change tube (see section
"Specifying float level per tube" in this chapter).
Ifthetubesarerefilledbyinsertingthetubecoinswiththecassetteinstalled,
you also have to activate the float-up function (see section "Activating/
deactivating float-up function" in this chapter).
If the coin cassette is going to be removed to be refilled directly, you have
to activate the automatic tube counter programming (see section "Setting
tube counters to float levels automatically" in this chapter).
Specifying float level per tube
To specify the float levels:
Quick approach:
= Main menu > E = Settings > Coin settings > Float level
How often? Effect Ziel
11 x You enter the main menu
21 x You enter the SETTING menu
3until Coin settings You want to enter submenu COIN
SETTINGS
41 x You enter the submenu
5until Float level You want to enter submenu FLOAT LEVEL
61 x You enter the submenu
7/until tube desired You want to set a float level for this
tube
81 x Now you can set a float level for this
tube
9/until required digit You highlight the digit to be set
10 /until required value This value is to be set
11 Please repeat steps 9 and 10 to set the other two digits of the float level, if necessary
12 1 x You lock the set float level in memory
13 Please repeat steps 7 to 12 to set the float levels of the other tubes, if necessary
14 1 x/2 x You return to main menu/operating
mode

16
c2Configuration
SETTINGS FOR FILLING AND EMPTYING CASSETTE
Activating/deactivating float-up function
Youshouldactivatethefloat-upfunctionifthecassetteisrefilledbyinserting
the tube coins on site. This makes sure that all tube coins being inserted
after the float level has been reached will be directed to the return area.
If the float-up function is activated but no float level configured (float
levelforthesingletubes=000),thetubewillbefilleduntiltheoptional
50% filling level sensor is covered, or emptied until this sensor is no
longer covered.
To activate/deactivate the float-up function:
Quick approach:
= Main menu > E = Settings > Operating modes > Float-up
Press key ... How often? Effect
11 x You enter the main menu
21 x You enter the SETTING menu. The
correct menu item has already been
selected
31 x You enter submenu OPERATING MODES
4until Float-up You want to activate/deactivate the
FLOAT-UP function
51 x Now you can activate/deactivate the
FLOAT-UP function
6/until setting desired You want to activate/deactivate the
function
71 x You lock the setting in memory
81 x/2 x You return to main menu/operating
mode

17
c2Configuration SETTINGS FOR FILLING AND EMPTYING CASSETTE
Setting tube counters to float levels automatically
Activate this function if you remove the coin cassette to directly refill it
with a certain number of coins (float levels). This is to ensure that the tube
counters will be set to the float level coin number automatically in the tube
filling mode as soon as you remove the cassette from the coin changer.
To activate/deactivate the automatic tube counter programming:
Quick approach:
= Main menu > E = Settings > Operating modes > Program tube counters autom.
Press key ... How often? Effect
11 x You enter the main menu
21 x You enter the SETTING menu. The
correct menu item has already been
selected
31 x You enter submenu OPERATING MODES
4until Program tube
counters autom. You want to activate/deactivate the
function
51 x Now you can activate/deactivate the
function
6/until setting desired You want to activate/deactivate the
function
71 x You lock the setting in memory
81 x/2 x You return to main menu/operating
mode

18
c2Configuration
SETTINGS FOR FILLING AND EMPTYING CASSETTE
Correcting tube counters according to filling level sensors
Six tube counters are monitoring the exact number of coins in the tubes
and register each coin collected by and paid out from the tubes.
In addition each tube is equipped with up to four filling level sensors. If the
coin changer is supposed to compare the tube counter readings with the
measured filling levels of the sensors after a coin has been accepted or
paid out and correct the tube counters if necessary, you should activate
the automatic tube counter correction.
If the vending machine control is unable to process the automatic
correction of the tube counters, you must deactivate this function.
If the tube counter correction is deactivated, ensure that the tubes
are emptied either using the inventory keys or the service menu.
Otherwise the tube counters do not equal zero before refilling the
tubes, but the number of coins registered before emptying the tubes
(cp. separate service manual).
To activate/deactivate the tube counter correction:
Quick approach:
= Main menu > E = Settings > Operating modes > Tube counter correction
Press key ... How often? Effect
11 x You enter the main menu
21 x You enter the SETTING menu. The
required menu item has already been
selected
31 x You enter submenu OPERATING MODES
4until Tube counter
correction You want to activate/deactivate the
TUBE COUNTER CORRECTION
51 x Now you can activate/deactivate the
TUBE COUNTER CORRECTION
6/until setting desired You want the tube counters to be
corrected/not corrected according to
filling level sensors
71 x You lock the setting in memory
81 x/2 x You return to main menu/operating
mode

19
c2Configuration SETTINGS FOR FILLING AND EMPTYING CASSETTE
Resetting tube counters before fill-up
If change is refilled by inserting the tube coins but the cassette is removed
to be completely emptied before fill-up, the coin changer should be set so
that the tube counters will be reset when removing the cassette, i.e. before
refilling the tubes.
To activate/deactivate the tube counter reset:
Quick approach:
= Main menu > E = Settings > Operating modes > Tube counters correct. to zero
Press key ... How often? Effect
11 x You enter the main menu
21 x You enter the SETTING menu. The
required menu item has already been
selected
31 x You enter submenu OPERATING MODES
4until Tube counters
correct. to zero You want the TUBE COUNTERS to be
reset/ignored
51 x Now you can set the function
6/until setting desired You want the tube counters to be
reset/ignored when removing the coin
cassette
71 x You lock the setting in memory
81 x/2 x You return to main menu/operating
mode

20
c2Configuration
SETTINGS FOR FILLING AND EMPTYING CASSETTE
Redirecting cash-box coins to return area
If you replenish change by inserting coins and if you do not want the cash-
box coins to be accepted but only the tube coins, the coin changer can be
set so that all cash-box coins will be inhibited and redirected to the return
area when the changer is in tube filling mode.
To disable/enable the cash-box coins when refilling the coin cassette:
Quick approach:
= Main menu > E = Settings > Operating modes > Only tube coins in filling mode
Press key ... How often? Effect
11 x You enter the main menu
21 x You enter the SETTING menu. The
required menu item has already been
selected
31 x You enter submenu OPERATING MODES
4until Only tube coins in
filling mode You want only tube coins/also cash-box
coins to be accepted
51 x Now you can set the function
6/until setting desired In tube filling mode you want only
tube coins/also cash-box coins to be
accepted
71 x You lock the setting in memory
81 x/2 x You return to main menu/operating
mode
Other manuals for Currenza C2
3
Table of contents
Other NRI Cash Counter & Coin Sorter manuals

NRI
NRI v2 eagle User manual

NRI
NRI Currenza C2 User manual

NRI
NRI G-13.6000 User manual

NRI
NRI Currenza C2 User manual

NRI
NRI Currenza F2 User manual

NRI
NRI currenza c2 airport User manual

NRI
NRI G-18.mft User manual

NRI
NRI G-13.mft MDB/S1 User manual

NRI
NRI G-13.mft MDB/S1 User manual

NRI
NRI v2 eagle User manual