Nualight N51571 User manual

www.nualight.com
1/ 4
N51571 Remote User Manual
1. Product Picture
2. Product Feature
1)Product supply voltage is 3V(AAA*2);
2)2.4G wireless control, with feature of long distance and non-directional control;
3)Full keys design, unique interface, simple operation;
4)Work stable, low power consume, long standby time;
5)N51571 for N51570 PWM Dimmer 24V;
3. Technical Parameters
Working temperature
-20-60℃
Supply voltage
3V (AAA*2PCS)
Sleep state current
15uA
Emission current
17mA
Sleep state power consume
45uW
Emission power
51mW
Net weight
65g
Product size
L150*W40*H20 (mm)
2.4G remote control distance
≤30m
Emission frequency
2.4Ghz
Bright and Color adjust Grade
1024
Battery life
2 years

www.nualight.com
2/ 4
4. Remote Control Layout
Function of each key as below:
Name of Key
Instruction
Set button
Blank key
ON
ON in any time
OFF
OFF in any time
Brightness +
Increase light brightness( from darkest to brightest long press 6 seconds)
Brightness -
decrease light brightness( from brightest to darkest long press 6 seconds)
Hot brightness key +
10%,30%,70%,100% 4 levels brightness selection key, lights will go to last one
after each pressing.
Hot brightness key -
10%,30%,70%,100% 4 levels brightness selection key, lights will go to next one
after each pressing.
Mode key
100% static
Night light
5% brightness
DIY 1/DIY 2
Adjust the preferable light effect, long press DIY key for more than 3 seconds,
the lights will gradually change once, that is saved successfully
Delay button
Press this key,light will flash twice,Output will off after 30 automatically, this
function could be canceled by On/Off Keys

www.nualight.com
3/ 4
Wireless remote control code value setting method
The biggest advantage of this system is that it can not only solve the cabling problem in
engineering wirelessly, but also realize a wired-like operation experience. In order to facilitate the
early testing and debugging of the project, the factory status of the receiver is normally unpaired
and each remote control has a unique code value. The user should perform the matching work of
the remote control and the receiver during the installation of the project to avoid the mutual
influence of the radio frequency remote control technology during the later use.
Please pay attention to the following 3 points before operation:
1) All equipment in the complete system after installation should have a unified and unique
code value, so as to achieve the security and stability of the system.
2) The receiver can only store one code value and cannot be overwritten. Before learning the
new code value, it is necessary to clear the original code of the receiver; the remote control can
only save one code value but can be overwritten and can also restore the factory settings. In order
to facilitate the later maintenance, the three components that may be involved in the system
(including receivers, handheld remote controls, and panel remote controls) can realize mutual
learning of code values.
3) Since the receiver performs code value learning in the power-on state, in order to avoid
confusion in the area, it is recommended that each area has an independent power switch so that
the power of other areas can be easily cut off when the code is being operated.
(1)Code pairing operation: means that the receiver will only be controlled by the
value code remote control.
Step
Operation
Instructions
1
Connecting the load to the receiver and power
on it.
1.It is necessary to clear the code first, if the
receiver was coded before.
2.Batch operation can be performed within the
remote control range.
2
Press and hold “ON” on the remote control for
5 seconds, the indicator of the remote control
will flash quickly, means it enters the pairing
code transmission status.
Will automatically exit code transmission status
after 60 seconds, or pressing any key to exit.
3
See the load light flashes 3 times and return to
the initial state
Pairing coding is finished successfully
(2)Code clearing operation: means that the original code value of the receiver will be
cleared and returned to the factory state. Then it can be controlled by any compatible
remote control, and can learn to a new code.
Step
Operation
Instructions
1
Connecting the load to the receiver and
power on it.
1. The clearing operation should be finished within 5
minutes after the receiver is powered on. If exceeds
the time, can be powered on again.
2. Batch operation can be performed within the
remote control range.

www.nualight.com
4/ 4
2
Press and hold the remote control “Off” for
10 seconds. The indicator of the remote
control flashes quickly, means it enters
the clearing code transmission status.
1. Will automatically exit code transmission status
after 60 seconds, or pressing any key to exit.
2. If the original remote control is lost, the new
remote control can be used for clearing operations.
3
See the load light flashes 3 times and
return to the initial state
Clearing coding is finished successfully
(3)Code learning operation between remote controls: Used to unify system code values
or copy a new remote controls.
Since each remote control has its own unique code at the time of delivery, when there are
multiple remote controls in one system, one of them (for example, remote control A) must be
selected as the system code value, and the code value of the rest remote controls (for example,
remote control B) should be copied to the same one.
Step
Operation
Instructions
1
A remote control:Press and hold “ON” on the remote
control for 5 seconds, the indicator of the remote
control will flash quickly, means it enters the pairing
code transmission status.
Will automatically exit code
transmission status after 60 seconds, or
pressing any key to exit.
2
B remote control: long press "mode key" for 5
seconds, the remote indicator light changes from
100% light to off light, means entering the code value
receiving state
Will automatically exit the code value
receiving state after 30 seconds, or exit
after learning the code value
successfully.
3
see the B remote control indicator light flash 3 times
Code copying is finished and exit code
value receiving status.
(4) The remote control restores the factory setting: it means that the remote control will
be restored to the factory's unique code value.
Step
Operation
Instructions
1
Long press "mode " for 20 seconds
The remote indicator light state:
1-5th seconds: 100% turn on;
5-20th seconds: turns off;
20th seconds: back to turns on 100%, means
successful operation.
2
Press the "OFF" to confirm, the remote
indicator light flashes 3 times
Restore factory settings successfully.