manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Nutreco
  6. •
  7. Scanner
  8. •
  9. Nutreco Trouw Nutrition Agrocares Reference guide

Nutreco Trouw Nutrition Agrocares Reference guide

Popular Scanner manuals by other brands

Radio Shack PRO-433 quick start guide

Radio Shack

Radio Shack PRO-433 quick start guide

Atid AT911N series user guide

Atid

Atid AT911N series user guide

Siemens RUGGEDCOM WiN5100 Faq

Siemens

Siemens RUGGEDCOM WiN5100 Faq

Canon CanoScan LiDE 20 Specifications

Canon

Canon CanoScan LiDE 20 Specifications

Epson 4180 - Perfection Photo Product support bulletin

Epson

Epson 4180 - Perfection Photo Product support bulletin

Radio Shack PRO-72 owner's manual

Radio Shack

Radio Shack PRO-72 owner's manual

Lanier 5622 Operator's guide

Lanier

Lanier 5622 Operator's guide

Faro Freestyle 2 user manual

Faro

Faro Freestyle 2 user manual

Kramer VS-16N user manual

Kramer

Kramer VS-16N user manual

Z/I Imaging PhotoScan 2001 instructions

Z/I Imaging

Z/I Imaging PhotoScan 2001 instructions

Renkforce DS100-5M operating instructions

Renkforce

Renkforce DS100-5M operating instructions

Canon imageFORMULA CR-120N user manual

Canon

Canon imageFORMULA CR-120N user manual

Fujitsu FI-4860C2 Specifications

Fujitsu

Fujitsu FI-4860C2 Specifications

HPc9861a 4400c Setup and support guide

HPc9861a

HPc9861a 4400c Setup and support guide

Kodak i5800 Scanner Brochure & specs

Kodak

Kodak i5800 Scanner Brochure & specs

Kodak i7300 user guide

Kodak

Kodak i7300 user guide

Revopoint POP user manual

Revopoint

Revopoint POP user manual

Fujitsu fi-4860C installation guide

Fujitsu

Fujitsu fi-4860C installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Avoid eye contact with the light source of the
Scanner.
Burn hazard - bottom parts are hot during
use. Do not touch the bottom parts unless the
Scanner is turned off and cooled down.
Warnings
IR
The AgroCares Scanner is a Near Infra-Red (NIR) measuring
device. It must be fully charged before first use. First time
charging requires approximately 18 hours. After this,
charging requires 11 hours. To avoid battery damage please
make sure you recharge the battery at least once a month.
The calibration cap, especially the yellow side, is extremely
sensitive. Please follow the cleaning instructions carefully to
avoid damage.
Tips
Scanner Quick Reference Card
1. Handheld scanner & calibration cap
1A. Scan button (ON/OFF)
1B. Bluetooth connection indicator
1C. Battery indicator
2. Charging port
3. Temperature sensor
4. Infra Red (IR) light source
5. Electrical Conductivity (E.C.) probes
6. Reset button
7. Calibration Cap
7A. WHITE ‘Background Sample’
7B. YELLOW ‘Standard Sample’
7. USB cable
8. Power socket
9. Cleaning products
10. Sample tray
1087
3
4
5
2
1C
180
O
7A
7B
9
1A
1B
3. System Set-up
The AgroCares Scanner is operated with an application on an Android smartphone (5.0 or higher).
2. Accessories
7
6
4. Registration
Scanner Quick Reference Card
A. Download one of the NutriOpt or AgroCares mobile apps from the Google Play Store. In order to use
the app, you need a valid license key. You can purchase your license from the AgroCares webshop
(webshop.agrocares.com).
B. Register your account in the app and login with the same credentials (email and password) that were
used for the webshop, or register directly in app. After logging in, you can enter the license key.
B. The device name of your Scanner is on the
back side of the handle. The device name
should follow this scheme: ‘SC_xxxxX’.
C. Navigate to Account and select your Scanner from ‘Device Settings’. After the app and the Scanner are connected, you
can proceed with scanning. Follow the instructions that are given in the app.
The ‘reset’ icon is located on the side of the Scanner. Reset the Scanner by touching the ‘reset’ icon with the magnet part
of the charger cable. You will hear a soft click. Press the ‘Scan’ button for 3 seconds to start it up again.
6. Resetting your Scanner
L
o
5. Starting-up and connecting the Scanner
A. Turning the Scanner ON. Press the SCAN
button (1A) for 3 seconds. The Scanner will
initiate its start-up sequence indicated by the
blinking green battery icon. The Scanner is
ready to be connected via Bluetooth when the
battery icon (1C) turns continuously green and
the Bluetooth indicator (1B) starts blinking.
IR
IR
Devicename: SC_134C
serialnumber: R522GH234
input: DC=5V/1.6A
designandproduction location: TheNetherlands
Device name : SC_134C
serial number : R522GH234
input: DC = 5V/1.6A
design and production location: The Netherlands
RESET
Cleaning your Scanner:
Proper care of the sensor head is needed to ensure a good performance of the device. Therefore, the bottom needs to be
kept clean at all times by using the cloth and the brush.
Cleaning your calibration cap:
The yellow side of the calibration cap cannot, in any way, handle water. Additionally, the yellow part is made out of fibre
material which can’t be brushed. Scan the yellow side only with a clean scanner and wipe it gently with a soft cloth if it is
a bit dirty.
The white part of the calibration cap needs to be clean and dry. The white side can be cleaned with a moist towel with a
drop of an abrasive cleaning product. The material of the white side absorbs water, therefore drying takes several hours.
The cap can be dried on the heater.
7. Cleaning
More information
Check for additional information, instructions and manuals at your portal via www.agrocares.com
and check www.nutriopt.com/onsiteadviser for more information about your NutriOpt license.