Nuvico Xcel NCT-4M-E2 User manual

Package
Overview
Installation
1
2
3
4
►Connecting Network Cable
2
13
* 1 It is recommended to install the water-proof cap for network cable connection.
* 2 If the PoE network switch is used to connect the camera that supports the PoE
power supply, DC12V power supply is not required.
①Loosen the nut from the main element.
②Run the network cable (without RJ 45 connector) through the
both elements. Then crimp the cable with RJ 45 connector.
③Connect the cable to the hermetic connector. Then tighten the
nut and the main cover.
Thank you for purchasing our product. There may be several
technically incorrect places or printing errors in this manual.
The updates will be added into the new version of this manual.
We will readily improve or update the products or procedures
described in the manual. The content is subject to change
without notice.
Warning and Caution
■If the product does not work properly, please contact your dealer
or the nearest service center. Never attempt to disassemble the
camera yourself. (We shall not be responsible for any problems
caused by unauthorized repair or maintenance.)
■Keep away from liquid while in use.
■In the use of the product, you must be strict compliance with the
electrical safety regulations of the nation and region. When the
product is mounted on wall or ceiling, the device shall be firmly
fixed.
■Do not use camera beyond specified voltage range.
■Do not drop the camera or subject it to physical shock.
■ Avoid touching the camera lens.
■If cleaning is necessary, please use clean cloth to wipe it gently.
If the device will not be used for a long time, please cover the lens
cap to protect the device from dirt.
■Do not aim the camera at the sun or extra bright place.
■Do not place the camera in extremely hot, cold (the operating
temperature shall be -20˚C~50˚C), dusty or damp locations, and do
not expose it to high electromagnetism radiation.
■To avoid heat accumulation, good ventilation is required for
operating environment.
■A few parts of the device shall be replaced regularly according
to their average enduring time. Regular checking is recommended
for all users.
Camera Quick start guide
CD Water-proof cap Plastic plug ×4
Drill template
4 tapping screws PA 4×25
Please make sure that the wall or ceiling is strong enough to
withstand 3 times the weight of the camera.
①
disassemble the camera from the mounting base.
Rotate the fixed ring of the camera in anti-clockwise direction to
② Attach the drill template to the place where you want to fix the camera
and then drill 4 screw holes and 1 cable hole ( if you want to route the
cables through the mounting base ) according to the drill template.
∅5
∅68.2
∅94
48.1mm
48.1mm
Dome
Enclosure
Fixed Ring
Mounting Base
Network Cable
DC12V
123
3
1
2
Network Cable
Mounting Base Power Cable
NCT-4M-E2 Eyeball Camera
Quick Start Guide

IE Network Connection
5
MENU
MENU
IPC
IPC
Network Cable Network Cable
Network Cable
Switch
Router Computer
Computer
●Access the camera through Xcel IP Utility
Here we take accessing IP camera via LAN for example. In LAN,
there are two ways to access. 1. Access through Xcel IP Utility;
2. Directly Access through IE Browser
①Make sure that the camera and the PC are well connected via LAN.
②Find the Xcel IP Utility from the CD and then install it in the computer.
After that, run the Xcel IP Utility as shown below.
Device Network Search
Imme dia te Refr esh
name
name
name
IPC
IPC
IPC
unkn ow n
unkn ow n
unkn ow n
192. 16 8.226.2 01
192. 16 8.1.2
192. 16 8.1.3
80
80
80
9008
9008
9008
255. 25 5.
255. 25 5.
255. 25 5.
Modi fy N etwork Pa ra meter
Mac Add re ss
IP Address
Modi fy
CE :98 : 23 : 75 :35 :22
192 .1 68 . 2 26 . 201
255 . 25 5 . 25 5 . 0
192 .1 68 . 2 26 . 1
i
Tip : En ter the a dm inistra to r passw or d, and
then m od ify the net wo rk para me te rs.
Total De vi ce: 3
Loca l IP Ad dr es s:192 .16 8.1.4Subnet M as k:255 .25 5.2 55.0 Gate wa y: 192.168 .1.1 DN S:210.21 .19 6.6
Devi ce N ame Device Type IP Address Http P or t Data P or t Subnet
Prod uc t Model
Abou t
Subn et M ask
Gate wa y
Restore IPC Default Configuration
③Modify the IP address. The default IP address of this camera is
192.168.226.201. Click the information of the camera listed in the
above table to show the network information on the right hand.
Modify the IP address and gateway of the camera and make sure its
network address is in the same local network segment as that of the
computer. Please modify the IP address of your device according
to the practical situation.
Mac Address
IP Address
Modify Network Parameter
Modify
CE :98 :23 :75 :35 :22
192 .168 . 1 . 201
255 . 255 . 255 . 0
192 .168 . 1 . 1
Subnet Mask
Gateway
For example, the IP address of your computer is 192.168.1.4. So the
IP address of the camera shall be changed to 192.168.1.X. After
modification, please input the password of the administrator and click
“Modify” button to modify the setting.
The default password of the administrator is “123456”.
④ Double-click the IP address and then the system will pop up the IE
browser to connect IP-CAM. After downloading Active X control, a
login window will pop up. Input the user name and password to login.
●Directly Access Through IE
The default network settings are as shown below:
IP address: 192.168.226.201 HTTP:80
Subnet Mask: 255.255.255.0 Data Port:9008
Gateway: 192.168.226.1
You may use the above default settings when you log in the camera
for the first time.
①Set the IP address of the PC and make sure the network segment
should be as the same as the default settings of IP-CAM. Open the
network and share center. Click “Local Area Connection” to pop up
the following window. Select “Properties” and then select Internet
protocol according to the actual situation (for example: IPv4).
Next, click “Properties” button to set the network of the PC.
②Open the IE browser and input the default address of IP-CAM
and confirm. The IE browser will download Active X control
automatically.
③After downloading Active X control, the login dialog box will
pop up.
④Input the default username and password and then enter to view.
NCT-4M-E2450043000480 A0
The default username is admin; the default password is 12345 6.
⑤The installation is complete as shown below.
③
base to the ceiling or wall with screws.
then secure the mounting Route the cables and connect the cables. And
④ Adjust the camera to obtain an optimum angle. Then secure the camera
to the mounting base.
Ceiling or Wall
Other manuals for Xcel NCT-4M-E2
1
Table of contents
Other Nuvico IP Camera manuals