NVC ODESSA V2 User manual

1
ODESSA V2 LED FLOODLIGHT INSTRUCTIONS
Issue 04 on 5
th
March 2021
THANK YOU for buying this product. To help ensure it gives complete satisfaction please install it according
to these instructions and then pass the instructions to the appropriate person for retention and future
reference.
SAFETY This is a mains powered product. It is designed to be installed by suitably qualified personnel
only and in accordance with the applicable building and electrical regulations. Before installation or
maintenance the electrical supply to the product must be isolated.
INSTALLATION SUPPORT If installation advice or accessories are required please contact us at the above
address. We will do our best to help. When reporting a suspected fault or seeking installation support the
problem is likely to be resolved most quickly if you have full product details to-hand, as well as details of when
and where it was purchased.
LUMINAIRE INSTALLATION
1. Secure the luminaire into its required fixing position using the fixing holes/slots provided in the stirrup
mounting bracket (see diagrams above), ensuring the chosen method is sufficient to support the
luminaire weight.
2. To rotate the luminaire to the required angle, loosen the two hinge screws where the stirrup bracket
joins the main fitting with an allen key, rotate to required position, then retighten to secure.
3. The luminaire is supplied with a power supply lead already attached. Route the free end to a suitably
IP rated connection point (minimum IP65) & terminate ensuring correct polarity is observed.
WARNING: THIS LUMINAIRE MUST BE EARTHED
4. Reconnect power supply & check for correct operation.
MAINTENANCE
The luminaire should be switched off & allowed to cool before any maintenance is carried out.
1. Cleaning of the glass front cover should be carried out at regular intervals so as not impair
photometric performance.
2. Dust should not be allowed to accumulate on the rear of the product as this will affect the thermal
performance of the heat sink.

2
PIR-PEC SENSOR OPTION (…/PIR-PEC/…)
With the passive infra-red and photocell (PIR-PEC) sensor version, the following information is applicable.
PIR RATINGS
Power supply 220-240VAC 50Hz
Power Consumption 0.8W work, 0.2W static
Handset Battery Type CR2025 (Instructions on how to change on handset)
Recommended mounting height 1.8m – 2.5m
Detection range See diagram below, 8m max.
Photocell 70 Lux OFF / 35 Lux ON
Ambient light level setting Day mode = Always work, Dusk mode = Work at low light levels (60 Lux or less)
Time out settings 15 sec, 30 sec, 1 min, 3 min, 5 min, 10 min, 15 min, 30 min
Default settings PIR = On, Lux = Dusk mode, Sensitivity = Near distance, Time out = 30 sec
TO CHANGE PIR SETTINGS
The unit comes with a remote control handset, which is used to change settings of the PIR. If the default settings (listed above) are not
suitable, then the use the handset as follows:
PIR TESTING
It may be possible to test the PIR using your required settings, but if it is daylight then you can test it by:
1. Using the remote control handset, set sensor to:
oDAY MODE by pressing the green “Day mode” button
oFAR DISTANCE (max sensitivity) by pressing blue “Far distance” button
oTIME DELAY to 15 Seconds by pressing the orange “15 sec” button
2. Avoid sensor detection to allow fitting to go off.
3. Create movement in front of the sensor & the luminaire will switch on.
4. Cease movement & the luminaire will switch off after 15 seconds.
5. Once satisfied it is working, adjust to required settings as listed above.
PE CELL TESTING
•Using the remote control set the fitting to Photocell only operation by pressing the blue button marked PE cell.
•To test cover the sensor and the fitting will come on, once uncovered the fitting will go off.
FAULT FINDING
If you experiencing a problem please check through the following before making contact with NVC:
Fault - Load does not come on
•Check to see if the live supply to the circuit is good.
•Check that the “Lux Sensing” setting matches the user requirements. If the 60 lux threshold of “Dusk Mode” is too low for switch
on, then change to “Day Mode” setting to always come on.
•Check that the photocell mode of operation has not been selected.
Fault - Light does not go off
•Ensure that the area is left unoccupied for longer than the selected timer setting.
•Avoid direct sunlight entering the sensor.
•Do not site within 1m of forced air heating or ventilation.
•Do not fix to a vibrating surface.
Lux sensing (green buttons):
Day mode = Always come on
Dusk mode = Only come on when
ambient
l
ight level < 60 lux
(Default)
Time out setting (orange buttons):
15 seconds to 30 mins
(Default = 30 secs)
Sensitivity setting (blue buttons):
Near distance = Picks up in shorter range
(Default)
Far distance = senses
in longest range
Override fitting OFF
ON/Manual Override = Turn the
luminaire on, but with no PIR
function
ON/PIR sensor = Turn on PIR mode
(Default)
Note: Press button to select setting. A
successful setting is shown by the
fitting switching off & then back on
.
DETECTION RANGE
8m maximum. Most sensitive on
direct perpendicular to front of
fitting/sensor, so fitting should be
tilted/angled to suit
.
NOTE! The luminaire will flash
off & on to show a handset
command has been received.
P
hotocell
mode
only
Table of contents