nvent Schroff 24579-081 User manual

CPCI System Subrack 2 U
User’s Manual
Product No.:
24579-081
April 14, 2011
Doc-No: 63972-233_R1.1

Impressum:
Schroff GmbH
D-75334 Straubenhardt, Germany
The details in this manual have been carefully compiled and
checked - supported by certified Quality Management System
to EN ISO 9001/2000
The company cannot accept any liability for errors or misprints.
The company reserves the right to amendments of technical
specifications due to further development and improvement of
products.
Copyright2011
All rights and technical modifications reserved.
Rev. Date updated Change
R1.0 January 14, 2008 Initial Release
R1.1 April 18, 2011 Fan Tray with mini compression latch

CPCI System Subrack 2 U
24579-081
www.schroff.biz I R1.1, April 18, 2011
Table of Contents
1 Safety................................................................................................................. 1
1.1 Intended Application............................................................................................ 1
1.2 Safety Instructions ............................................................................................... 2
1.2.1 Safety Symbols used in this document.................................................. 2
1.3 General Safety Precautions................................................................................. 2
2 Product Definition............................................................................................. 3
2.1 References and Architecture Specifications........................................................ 3
2.2 Subrack System Overview................................................................................... 3
2.3 Subrack................................................................................................................ 4
2.4 CPCI Backplane .................................................................................................. 4
2.5 Power Supply....................................................................................................... 5
2.5.1 Grounding/Earthing................................................................................ 5
2.5.2 ATX Power Supply................................................................................. 6
2.6 Cooling................................................................................................................. 7
2.7 Remove/Install Fan Tray...................................................................................... 7
3 Installation......................................................................................................... 9
3.1 General Installation Guidelines............................................................................ 9
3.1.1 Unpacking.............................................................................................. 9
3.1.2 Ensuring Proper Airflow......................................................................... 9
3.2 Rack-Mounting................................................................................................... 10
3.3 Initial Operation.................................................................................................. 10
4 Service............................................................................................................. 11
4.1 Technical support and Return for Service Assistance....................................... 11
4.2 Declaration of Conformity .................................................................................. 11
4.3 Scope of Delivery............................................................................................... 12
4.4 Accessories ....................................................................................................... 12
4.5 Spare Parts........................................................................................................ 12
5 Technical Data ................................................................................................ 13
6 Dimensions ..................................................................................................... 14

CPCI System Subrack 2 U
24579-081
www.schroff.biz II R1.1, April 18, 2011

CPCI System Subrack 2 U Safety
24579-081
www.schroff.biz 1 R1.1, April 18, 2011
1 Safety
1.1 Intended Application
The CompactPCI (CPCI) system subrack, described in this manual, is intended
as a platform for a microcomputer system based on the CompactPCI Standard
PICMG 2.0 Rev.3.
The CPCI system subracks are designed for protection class IP 20 and can be
used only in the resp. environments.
For higher protection requirements, e.g. IP 54/55 you must install the system
subrack in a protective case.
CPCI system subracks are not end-products, so there is no valid approval for
this unit. In order to enable stand-alone functionality, additional elements are
required. An operational system is achieved only by way of appropiate CPCI
boards.
The completion and final testing of the units have been carried out, or at least
supervised, by qualified technicians. These instructions are directed exclusively
to these qualified technicians i.e.engineers, trained and qualified electricians
etc.
Make sure that:
• the finished system complies with the safety regulations currently applicable
in the country it is going to be used.
• the finished system complies with all other regulations and specifications at
the place and country of use, e.g. interference limits, approval by the tele-
communications authorities.

CPCI System Subrack 2 U Safety
24579-081
www.schroff.biz 2 R1.1, April 18, 2011
1.2 Safety Instructions
The intended audience of this User’s Manual is system integrators and
hardware/software engineers.
1.2.1 Safety Symbols used in this document
1.3 General Safety Precautions
• Service personnel must know the necessary electrical safety, wiring and
connection practices for installing this equipment.
• Install this equipment only in compliance with local and national electrical
codes.
Hazardous voltage!
This is the electrical hazard symbol. Familiarise yourself with the danger of
electrical voltages and the safety precautions to avoid accidents before
starting to work with parts that carry dangerous voltages.
Caution!
This is the user caution symbol. It indicates a condition where damage of the
equipment or injury of the service personnel could occur. To reduce the risk of
damage or injury, follow all steps or procedures as instructed.
Danger of electrostatic discharge!
Static electricity can damage sensitive components in a system. To avoid
damage, wear ESD wrist straps or at regular intervals touch blank enclosure
parts.
Warning!
Voltages over 60 VDC can be present in this equipment. This equipment is
intended to be accessed, to be installed and maintained by qualified and
trained service personnel only.
This equipment is designed in accordance with protection class 1!
It must therefore be operated only with protective GND/earth connection!

CPCI System Subrack 2 U Product Definition
24579-081
www.schroff.biz 3 R1.1, April 18, 2011
2 Product Definition
The Schroff CPCI system subrack consists of:
• A shielded 19“ subrack with front and rear card cage for
6 U boards according to CompactPCI Standard PICMG 2.0 Rev.3
• A 6 U 4 slot CPCI Backplane, system slot left (bottom)
• An ATX power supply (250 W) with wide range input
• Fans for the active cooling of the boards
• DC switch
2.1 References and Architecture Specifications
• User Manual CPCI Backplanes
Order no.: 73972-101
• Technical Data Schroff CPCI Backplanes 23006-7xx
Order no.: 73972-088
• User Guide Schroff CPCI Backplanes 23006-799
Order no.: 63972-214
Further information can also be found in the catalogue „Electronic Packaging“
and on the internet under www.schroff.biz
2.2 Subrack System Overview
Figure 1: System Overview
12311811
1 CPCI backplane 3 ATX Power Supply
2 Fan Tray 4 DC Switch

CPCI System Subrack 2 U Product Definition
24579-081
www.schroff.biz 4 R1.1, April 18, 2011
2.3 Subrack
The 2 U 19” subrack is based on the Schroff europacPRO system with EMC
shielding. The card cage enables the horizontal assembly of 4 CPCI front
boards (6 U, 4 HP, 160 mm deep) and 4 Rear I/O Boards (6 U, 4 HP, 80 mm
deep).
The right guide rails of the card cage are equipped with ESD clips.
2.4 CPCI Backplane
The horizontally assembled 6 U Backplane provides:
• CompactPCI bus (PICMG2.0 R.3.0) with System Slot left (bottom)
• Connector for the Fan Tray at the left side
• Connector for the power supply at the right side
Applicable Specifications:
PICMG 2.0 R3.0 CPCI Core Specification
PICMG 2.01 R2.0 Hot Swap
PICMG 2.09 R1.0 System Management Bus
PICMG 2.10 R1.0 Keying

CPCI System Subrack 2 U Product Definition
24579-081
www.schroff.biz 5 R1.1, April 18, 2011
2.5 Power Supply
Power is provided through a 250 W ATX power supply with wide range input.
The power supply is located to the right of the card cage behind a perforated
front panel. The AC input is via an IEC 320-C14 connector at the back.
The mains on/off switch is located at the back close to the AC input connector.
With a DC switch at the front you can switch-off the DC outputs of the power
supply.
2.5.1 Grounding/Earthing
Hazardous voltage!
Parts of the power supply may be exposed with hazardous voltage. Always
remove mains/line connector before carry out any assembly work.
Caution!
Your system has not been provided with a AC power cable. Purchase a
AC power cable that is approved for use in your country. The AC power cable
must be rated for the product and for the voltage and current marked on the
product's electrical ratings label. The voltage and current rating of the cable
should be greater than the ratings marked on the product.
Caution!
The unit is designed inaccordance with protection class 1! It must therefore be
operated with protective earth/GND connection. Use only a three conductor
AC power cable with a protective earth conductor that meets the IEC safety
standards!

CPCI System Subrack 2 U Product Definition
24579-081
www.schroff.biz 6 R1.1, April 18, 2011
2.5.2 ATX Power Supply
Figure 2: ATX Power Supply
Table 1: Techn. Data ATX Power Supply
10006854
1 ATX Power Supply 4 AC Connector (IEC320-C14)
2 AC Switch 5 DC Switch
3Fan
Input voltage 90...264 VAC, 120...380 VDC / active PFC
Input frequency 47...63 Hz
Input current 4 A (115 V) / 2 A (230 V)
Output (max) 5 V / 23 A; 3,3 V / 14 A, 12 V / 16 A, -12 V / 0,5 A)
Output (min) 5 V / 3 A; 3,3 V / 1 A, 12 V / 2 A, -12 V / 0,1 A)
Inrush Current 65/130 A (115/230 VAC)
Efficiency >70%, (115 VAC full oad)
Overload protection 110...160%, shut down
Short circuit protection +3,3 V, +5 V, +12 V, shut down / -5 V, -12 V, +5 VSB, auto recovery
Over voltage protection +3,3 V (+3,6...+4,2 V), +5 V (+5,6...+6,6 V), +12 V (13,2...14,6 V)
Ripple +3,3 V 60 mV / +5 V 50 mV / +12 V 120 mV / -12 V 120 mV
Load regulation +3,3 V ±5% / +5 V ±5% / +12 V ±5% / -12 V ±10%
Hold up time >16 msec.
Power Good Signal switch-on delay 100...500 msec. Switch-off delay 1msec.
Isolation voltage Input / Chassis 3000 VAC for 60 sec. Input / Output 1800 VAC for 60 sec.
Leakage current <3,5 mA, 115 VAC / 230 VAC
Operating temperature 0...+50°C
Derating Power on: +3,3 V: +30°C/14 A, +40°C/12 A, +50°C/10 A
Storage temperature -20...+80°C
Humidity 20...80% RH, non-condensing
MTBF 120.000 h at +50°C, without fan
Safety TÜV EN 60950 / UL 60950
EMV CE
Fan ball bearing fan, temperature regulated
Dimensions (LxBxH) 190 x 100 x 40 mm, ±0,5mm

CPCI System Subrack 2 U Product Definition
24579-081
www.schroff.biz 7 R1.1, April 18, 2011
2.6 Cooling
Figure 3: Fan Tray
The CPCI boards are cooled by forced air convection through two 12 VDC axial
fans (109 m³/h (64 cfm) each).
The operating temperature is from 0°C to 50°C, but note that the power supply
starts derating at 50°C.
2.7 Remove/Install Fan Tray
The Fan Tray is locked into the chassis by a mini compression latch with
indicator red/green. In closed position the indicator shows green, in open
position the indicator shows red.
Remove Fan Tray:
• Turn the knob counterclockwise until the indicator shows red.
• Pull out the Fan Tray:
Install Fan Tray:
• Insert the Fan Tray into the slot
Turn the knob clockwise until the Fan Tray is locked into the chassis.(By turning
the knob clockwise, the cam is put into the latched position and the green
indicator appears. Once latched, a further turning of the knob makes the cam
starts its compression feature until the Fan Tray is locked.)
12311810

CPCI System Subrack 2 U Product Definition
24579-081
www.schroff.biz 8 R1.1, April 18, 2011
Figure 4: Airflow
12308828
Caution!
To maintain proper airflow, all open slots must be covered with filler panels.
The filler panel should include an airflow baffle that extends to backplane.

CPCI System Subrack 2 U Installation
24579-081
www.schroff.biz 9 R1.1, April 18, 2011
3 Installation
3.1 General Installation Guidelines
3.1.1 Unpacking
Consider the following when unpacking and storing the system:
• Leave the system packed until it is needed for immediate installation.
• After unpacking the system, save and store the packaging material in case
the system must be returned.
If the packaging is damaged and possible system damage is present, report to
the shipper and analyze the damage.
3.1.2 Ensuring Proper Airflow
• Install the system in an open rack whenever possible. If installation in an
enclosed rack is unavoidable, ensure that the rack has adequate ventilation.
• Maintain ambient airflow to ensure normal operation. If the airflow is blocked
or restricted, or if the intake air is too warm, an over temperature condition
can occur.
• Ensure that cables from other equipment do not obstruct the airflow through
the systems.
• Use filler panels to cover all empty chassis slots. The filler panel prevents
fan air from escaping out of the front of an open slot.
Caution!
When opening the shipping carton, use caution to avoid damaging the system.
Caution!
To maintain proper airflow, all open slots must be covered with filler panels.
The filler panel should include an airflow baffle that extends to backplane.

CPCI System Subrack 2 U Installation
24579-081
www.schroff.biz 10 R1.1, April 18, 2011
3.2 Rack-Mounting
This subrack system can be installed in 19“ equipment racks. The rack must be
accessible from the front and rear for equipment installation.
Mounting Instructions:
• Ensure that the rack is constructed to support the weight and dimensions of
the system.
• Install any stabilizers that came with your equipment rack before mounting
or servicing the system in the rack.
• Load the rack from the bottom to the top, with the heaviest system at the
bottom, avoid uneven mechanical loading of the rack.
3.3 Initial Operation
• Ensure that the system has not been damaged during transport, storage or
assembly.
• Check the Protective Earth (PE) resistance, should be < 0,1 Ohm.
• Switch on the system and check all CPCI voltages directly on the
backplane connectors before the board assembly.
Note: The ATX power supply requires a minimum load!
• Plug-in the boards
• Cover all open Slots with filler panels.
Warning!
Voltages over 60 VDC can be present in this equipment. This equipment is
intended to be accessed, to be installed and maintained by qualified and
trained service personnel only.
This eqipment is designed in accordance with protection class 1!
It must therefore be operated only with protective GND/earth connection!

CPCI System Subrack 2 U Service
24579-081
www.schroff.biz 11 R1.1, April 18, 2011
4 Service
4.1 Technical support and Return for Service Assistance
Wegenerallyrecommendto returnthecompletesubracksystem.Forallproduct
returns and support issues, please contact your Schroff sales distributor or
www.schroff.biz.
Werecommendthatyousavethepackingmaterial.Shippingwithoutthe original
packing material might void the warranty.
4.2 Declaration of Conformity
SCHROFF CompactPCI system subracks are developed and manufactured
according to EN 60950-1.
SCHROFF CompactPCI system subracks are not end-products with
independent functionality as described in the definition of the EMC regulations,
and therefore a CE marking is not required. However, when CPCI cards are
assembled according to specification, the systems fulfill the requirements in
accordance with EMC Directive 2004/108/EG and Low-voltage Directive
2006/95/EG.
Interferenceresistanceandinterferenceemissionsarefactors which areheavily
influenced by the type and quantity of CPCI cards used in the system assembly.
Through the use of high quality line filters and EMC optimized enclosure design,
SCHROFF offers CPCI systems which serve as an ideal base for system
integrators, which comply with the prescribed limits of EN 6100-6-3 and
EN 61000-6-2
The systems are generally equipped with power supplies which possess
CE markings in accordance with EN 60950-1, EN 61000-6-3, EN 61000-6-2).
Before delivery a high-voltage, protective earth and functionality test is carried
out on each individual system.

CPCI System Subrack 2 U Service
24579-081
www.schroff.biz 12 R1.1, April 18, 2011
4.3 Scope of Delivery
4.4 Accessories
4.5 Spare Parts
On request.
Quantity Description
1 19” subrack, shielded, black powder coated (RAL9005)
1 CPCI backplane (PICMG2.0 R.3.0), 4 slot 6 U
1 Front card cage for max. 4 boards 6 U 160 mm deep
IEEE guide rails inc. ESD clips (ESD clip assembled at the right)
1 Rear card cage for max. 4 boards 6 U 80 mm deep
IEEE guide rails inc. ESD clips
1 250 W ATX power supply with input range of 100 VAC to 240 VAC
with 4 voltages: 3,3 V / 14 A; 5 V / 23 A; 12 V / 16 A; -12 V / 0,5 A)
1 Complete AC/DC cabling
1 DC switch
1 Fan Tray, hot swappable
Order No. Description
20848-7xx Slot covers with front panel and EMC shielding for vacant slots. For dimensions, please see
catalogue.
34562-8xx Slot covers for vacant slots. For dimensions, please see catalogue.
24579-03x Printed Circuit Board covers (solder side covers). For dimensions, please see catalogue

CPCI System Subrack 2 U Technical Data
24579-081
www.schroff.biz 13 R1.1, April 18, 2011
5 Technical Data
Table 2: Technical Data
Dimensions
Height 88.10 mm (2 U)
Width 482.80 mm (19“)
Depth (Card cage) 275 mm
Depth (Overall with handles) 309 mm
Weight
Completely assembled 5 kg
Power Supply
Input Voltage 100 VAC bis 240 VAC
Frequency 50 / 60 Hz
Power input up to 250 W
Cooling
2 x 12 VDC fans 109 m³/h (64 cfm) each, free blow
Ambient Temperature
Operation +0 °C to +50 °C
Storage -40 °C to +85 °C
Humidity
Admissible humidity 30 % to 80 %, non-condensing
EMC, fulfils requirements for:
Transient Emissions EN 61000-6-3
Interference Resistance EN 61000-6-2
Safety
Test voltages according to EN 60950 Input - Output:
Input - PE:
Output - PE:
Output - Output:
4,3 kVDC
2,2 kVDC
0,7 kVDC
0,7 kVDC
Shock and vibration: EN 60068-2-6 and EN 60068-2-27
Electromagnetic Shielding
Shielding attenuation typ. 40 dB at 1 GHz if shielded front
panels are used.

CPCI System Subrack 2 U Dimensions
24579-081
www.schroff.biz 14 R1.1, April 18, 2011
6 Dimensions
Figure 5: Dimensions


SCHROFF GMBH www.schroff.biz
Langenalberstr. 96-100 Tel.: + 49 (0) 7082 794-0 Fax: +49 (0) 7082 794-200
D-75334 Straubenhardt
Table of contents
Other nvent Rack & Stand manuals

nvent
nvent SCHROFF NOVASTAR User manual

nvent
nvent VARISTAR User manual

nvent
nvent B165R User manual

nvent
nvent Caddy 512HD User manual

nvent
nvent 512 Series User manual

nvent
nvent CAT12 User manual

nvent
nvent SCHROFF VARISTAR User manual

nvent
nvent AFBS-B600 User manual

nvent
nvent Schroff 20836-220 User manual

nvent
nvent Schroff 20836-820 User manual

nvent
nvent FBS Series User manual

nvent
nvent SCHROFF VARISTAR 21130-761 User manual

nvent
nvent CJ6STS User manual

nvent
nvent HOFFMAN SYSPEND 180-MAX User manual

nvent
nvent Schroff 24579-400 User manual

nvent
nvent SCHROFF NOVASTAR User manual

nvent
nvent RAYCHEM JBM-100-A User manual

nvent
nvent SCHROFF VARISTAR CP User manual