manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. nvent
  6. •
  7. Rack & Stand
  8. •
  9. nvent CAT12 User manual

nvent CAT12 User manual

2. Place cables
in the J-hook.
1. Install the
nVent CADDY CAT12
support clip.
The nVent CADDY CAT12 is equipped with a bend back
tab to provide contact free containment for
sensitive high performance cables.
3. (Optional) Using
pliers bend top
portion of hook
back at slot.
Load
Fig 12
Fig 8
Pre-Riveted Factory Assemblies
Fig 14
Fig 10
Fig 11
Fig 6 Fig 7
Fig 1 Fig 2 Fig 3
Fig 16
Fig 15
Fig 13
Fig 9
Fig 4 Fig 5
For use with Data Communication Cables only.
The nVent CADDY CAT12 support clip holds 4-pair UTP cables: 16 Cat.5/5e or 16 fiber optic
cables or 10 Cat.6.
Provides strain relief and routes cables so bend radius conforms to EIA/TIA-568-A standard.
Complies with UL,cUL, and NEC requirements for structured cabling systems.
Complies with 1997 EIA/TIA 569-A.
R
Note: Do not exceed recommended cable
quantities per fastener
Part Number
Article
Number
Fig.
Description
CAT12AF14
181840 1
1/16" [2] thru 1/4" [6] Z Purlin
CAT12VF14
181800 2
1/16" [2] thru 1/4" [6] vertical flange
CAT124Z34 181240
3
#12 thru 1/4" [6] wire, plain or threaded rod
& 1/8" [3] thru 3/8" [10] flange
CAT126Z34 181270
3/8" [10] plain ot threaded rod & 3/8" [10]
thru 9/16" [10] flange
CAT128Z34
N/A
1/2" [13] & 5/8" [16] threaded rod
CAT12AB
181900 4
Angle Bracket
CAT12CPNA
N/A
16
Angle bracket with pin driven mounting
hole
CAT12BC
N/A
6
1/8" [3] thru 1/2" [13] flange
CAT12BCB
N/A
7
1/8" [3] thru 1/2" [13] flange, rotates 360
CAT12BC200B
181430 8
1/8" [3] thru 5/8" [16] flange, rotates 360
CAT12BC200
181400 9
1/8" [3] thru 5/8" [16] flange
CAT12TS
181200 10
Support from Tee Grid
CAT1224
181650
11
1/8" [3] thru 1/4" [6] flange, bottom mount
rotates 360
CAT1258
181660
5/16" [8] thru 1/2" [13] flange, bottom
mount rotates 360
CAT12912
181670
1/2" thru 3/4" flange, bottom mount rotates
360
CAT1224SM
181510
12
1/8" [3] thru 1/4" [6] flange
CAT1258SM
181520
5/16" [8] thru 1/2" [13] flange
CAT12912SM
181530
1/2" [13] thru 3/4" [19] B1 flange
CAT12
181100 13
Hold 4-pair UTP cables: 16 Cat. 5/5e or 16
fiber optic cables or 10 Cat. 6
CATTS
181170 14
Support from Tee Grid
CAT12CD1B
181950 15
J-Hook to 3/4" & 1" round or square
pedestal
CAT12AFAB3
N/A
5
Angle bracket with pin driven mounting
hole
TECHNICAL SUPPORT:
www.nVent.com
CFS246_N
INSTRUCTION SHEET
1 OF 4
© 1997-2019 nVent All Rights Reserved


WARNING:
nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Instruction sheets are available at
1.
www.nVent.com
and from your nVent customer service representative.
nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
2.
All instructions must be
completely
followed to ensure proper and safe installation and performance.
3.
Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property
4.
damage, serious bodily injury and/or death, and void your warranty.
Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment.
5.
All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any
6.
other purpose.
NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified
engineer.
c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed.
Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are
owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the
right to change specifications without prior notice.
4' [121cm] TO
5' [152cm]
Fig 2
Squeeze
fastener
Rotate
into place.
1. Squeeze fastener.
2. Connect top edge over wire.
3. Twist into place.
4. Release.
Drop Wires, Rods and Flanges
Fig 1
Place cable
into nVent CADDY
CAT12
Fig 3
Note: Assemblies are
placed 4' to 5' apart to
keep the cable from
sagging more than 12"
at mid-span.
2. Use the built-it
thread impression
for quick field
assembly to a
wide variety of
supporting nVent
CADDY Fasteners.
1. Nail or screw
the J-hook
directly to
the structure.
1. Place fastener against flange. Tap straight down.
(1/16" [2mm] to 1/4" [6mm] flange or C Purlin)
2. Place cable into clip. Secure if desired.
* nVent CADDY Part Number VAFT may be used
for easy installation of verticle and angled
flange assemblies, from the floor.
C & Z Purlin
Create custom field assemblies as your needs require.
12" [30.5cm]
Part Number
Article
Number
Fig.
Description
CAT12AF14
181840 1
1/16" [2] thru 1/4" [6] Z Purlin
CAT12VF14
181800 2
1/16" [2] thru 1/4" [6] vertical flange
Part Number
Article
Number
Fig.
Description
CAT124Z34 181240
3
#12 thru 1/4" [6] wire, plain or
threaded rod & 1/8" [3] thru 3/8" [10]
flange
CAT126Z34 181270
3/8" [10] plain ot threaded rod & 3/8"
[10] thru 9/16" [10] flange
CAT128Z34
N/A
1/2" [13] & 5/8" [16] threaded rod
TECHNICAL SUPPORT:
www.nVent.com
CFS246_N
INSTRUCTION SHEET
2 OF 4
© 1997-2019 nVent All Rights Reserved
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are
owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the
right to change specifications without prior notice.
Or use 1/4-20
x 1/2" screw
4
Use SMS8 screw
if desired.
1/4-20 x 1/2" Screw
Fig 14
12
3
1. Push nVent CADDY CATTS or nVent CADDY CAT12TS
down on to tee grid.
2. Install cables.
3. To prevent cables from slipping when ceiling tiles
are moved, use pliers to bend top portion
of hook back at slot.
4. Screw to Tee Grid if desired.
Support From Tee Grid
Pre-Riveted
Fig 10
Fig 5
1. Place on beam and tighten screw securely,
(Approx. 20 in. lbs. torque.)
2. Place cables in clip.
Beam Clamp
Fig 6 Fig 8
Fig 7 Fig 9
1. Position nVent CADDY CAT12CPNA or nVent CADDY
CAT12AB on joist, wall or concrete.
2. Secure with
appropriate tool.
Fig 4
Angle Brackets
Fig 16
Fig 5
Fig 4
Part Number
Article
Number
Fig.
Description
CAT12AB
181900 4
Angle Bracket
CAT12AFAB3
N/A
5
Angle bracket with pin driven
mounting hole
CAT12CPNA
N/A
16
Angle bracket with pin driven
mounting hole
Part Number
Article
Number
Fig.
Description
CAT12BC
N/A
6
1/8" [3] thru 1/2" [13] flange
CAT12BCB
N/A
7
1/8" [3] thru 1/2" [13] flange, rotates 360
CAT12BC200B
181430 8
1/8" [3] thru 5/8" [16] flange, rotates 360
CAT12BC200
181400 9
1/8" [3] thru 5/8" [16] flange
Part Number
Article
Number
Fig.
Description
CAT12TS
181200 10
Support from Tee Grid
CATTS
181170 14
Support from Tee Grid using
1/4-20 x 1/2" screw
TECHNICAL SUPPORT:
www.nVent.com
CFS246_N
INSTRUCTION SHEET
3 OF 4
© 1997-2019 nVent All Rights Reserved
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are
owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the
right to change specifications without prior notice.
Fig 15
1. Position clip on pedestal.
3. Place cables in J-Hook.
2. Tighten screw thru clip
with 75 in-lb torque.
Floor Pedestal Support
1. With hammer, tap clip to flange.
Side Mount Flange Clips
1. With hammer, tap clip to flange.
Bottom Mount Flange Clips
2. Place cables in clip.
Fig 12
2. Place cables in clip.
Fig 11
Part Number
Article
Number
Fig.
Description
CAT1224
181650
11
1/8" [3] thru 1/4" [6] flange, bottom
mount rotates 360
CAT1258
181660
5/16" [8] thru 1/2" [13] flange, bottom
mount rotates 360
CAT12912
181670
1/2" thru 3/4" flange, bottom mount
rotates 360
Part Number
Article Number
Fig.
Description
CAT1224SM
181510
12
1/8" [3] thru 1/4" [6] flange
CAT1258SM
181520
5/16" [8] thru 1/2" [13]
flange
CAT12912SM
181530
1/2" [13] thru 3/4" [19] B1
flange
Part Number
Article
Number
Fig.
Description
CAT12CD1B
181950 15
J-Hook to 3/4" & 1" round
or square pedestal
TECHNICAL SUPPORT:
www.nVent.com
CFS246_N
INSTRUCTION SHEET
4 OF 4
© 1997-2019 nVent All Rights Reserved
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are
owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the
right to change specifications without prior notice.

Other nvent Rack & Stand manuals

nvent Schroff 20836-220 User manual

nvent

nvent Schroff 20836-220 User manual

nvent HOFFMAN SYSPEND 180-MAX User manual

nvent

nvent HOFFMAN SYSPEND 180-MAX User manual

nvent 512 Series User manual

nvent

nvent 512 Series User manual

nvent Schroff 24579-400 User manual

nvent

nvent Schroff 24579-400 User manual

nvent VARISTAR User manual

nvent

nvent VARISTAR User manual

nvent Schroff 24579-081 User manual

nvent

nvent Schroff 24579-081 User manual

nvent B165R User manual

nvent

nvent B165R User manual

nvent FBS Series User manual

nvent

nvent FBS Series User manual

nvent Schroff 20836-820 User manual

nvent

nvent Schroff 20836-820 User manual

nvent AFBS-B600 User manual

nvent

nvent AFBS-B600 User manual

nvent CJ6STS User manual

nvent

nvent CJ6STS User manual

nvent Caddy 512HD User manual

nvent

nvent Caddy 512HD User manual

nvent SCHROFF VARISTAR CP User manual

nvent

nvent SCHROFF VARISTAR CP User manual

nvent SCHROFF VARISTAR User manual

nvent

nvent SCHROFF VARISTAR User manual

nvent SCHROFF VARISTAR 21130-761 User manual

nvent

nvent SCHROFF VARISTAR 21130-761 User manual

nvent RAYCHEM JBM-100-A User manual

nvent

nvent RAYCHEM JBM-100-A User manual

nvent SCHROFF NOVASTAR User manual

nvent

nvent SCHROFF NOVASTAR User manual

nvent SCHROFF NOVASTAR User manual

nvent

nvent SCHROFF NOVASTAR User manual

Popular Rack & Stand manuals by other brands

Konig & Meyer 28070 manual

Konig & Meyer

Konig & Meyer 28070 manual

Gembird MA-WA1-01 user manual

Gembird

Gembird MA-WA1-01 user manual

CHIEF MSP-WL4C installation instructions

CHIEF

CHIEF MSP-WL4C installation instructions

Chenbro RM23712 Technical manual

Chenbro

Chenbro RM23712 Technical manual

Clarion HRM100 installation instructions

Clarion

Clarion HRM100 installation instructions

ResMed AIRMINI user guide

ResMed

ResMed AIRMINI user guide

vipp VIPP895 user manual

vipp

vipp VIPP895 user manual

Dantel B23-41076 Installation & operation manual

Dantel

Dantel B23-41076 Installation & operation manual

CHIEF MSBV installation instructions

CHIEF

CHIEF MSBV installation instructions

Gembird WM-55T-03 user manual

Gembird

Gembird WM-55T-03 user manual

ricoo TS8211 quick start guide

ricoo

ricoo TS8211 quick start guide

VEVOR STX001-047-01 user manual

VEVOR

VEVOR STX001-047-01 user manual

Ergotron 888-45-198 user guide

Ergotron

Ergotron 888-45-198 user guide

Toolson PRO UG2000PRO Translation of original operating manual

Toolson PRO

Toolson PRO UG2000PRO Translation of original operating manual

NAIM FRAIM manual

NAIM

NAIM FRAIM manual

Sanus Systems STEEL FOUNDATIONS SFC instruction manual

Sanus Systems

Sanus Systems STEEL FOUNDATIONS SFC instruction manual

Tektronix Keithley 4299-4 installation instructions

Tektronix

Tektronix Keithley 4299-4 installation instructions

FLINT HILL FHG39ZR Instruction manual parts catalog

FLINT HILL

FLINT HILL FHG39ZR Instruction manual parts catalog

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.