INSTALLATION &OPERATIONS MANUAL
FOR FUTURE REFERENCE
Model No: AM-H12A4/SR1
Reverse Cycle Portable Air Conditioner

CONTENTS
Introduction ................................................................
Safety Precaution ....................................................
Technical Specifications............................................
Parts Description .......................................................
Accessories................................................................
Control Panel..............................................................
Operation.....................................................................
Installation ............................................................
Maintenance .............................................................
Trouble Shooting ......................................................
Warning.....................................................................
1
2-3
4
5
6
8
9-10
11
12
7
13
13
Causes Solutions
The Wind Blowing Out, But The Cooling Effect Is Bad
Mistakes in temperature setting.
The air filteris blocked bydust.
The air inlet or outlet of machine is
blocked.
Turn the air conditioner on in very
hot room.
Cooling capacityis insufficient .
The doors or windows are open.
Set a proper temperature, setting
temperature should be lower than
ambient temperature.
Clean the air filter.
Remove the obstruction.
Allow additional timeto remove
stored heat from walls ,ceiling,
floor and furniture.
Reconfirm the required cooling
capacity with your dealer.
Close the doorsand windows.
Causes Solutions
Noise or vibration
The ground is not level or not flat
enough.
Place the unit on a flat, level ground
if possible.

12
To save the cost of a service call, please try the suggestions below to see if
you can solve your problem without outside help.
Causes Solutions
The power switch is released.
Power supply failure.
The fuse isburnt.
It doesn't reach the settime for start
up.
Switch on the power.
Wait for the recovery of power supply.
Replace the fuse.
Wait or eliminate the original setting.
Causes Solutions
Unit Doesn't Start When Pressing ON/OFF Button
It is notthree minutes afterswitch off.
Room temperature is lower than the
setting temperature.
Wait three minutes.
Reset the temperature.
Troubleshooting
Air Condition Will Not Operate
2.Wipe the unit with dry cloth .
3.If the unit is very dirty, please wipe with
wet cloth dipped by cold water .
Never use hot water over 40 (104 )to clean the air filter.
Do not use gasoline ,benzene ,thinner or any other chemicals, or any liquid
insecticide on the air conditioner, as these substances may cause flaking off of
the paint ,cracking or deformation of plastic parts .
Never attempt to clean the unit by pouring water directly over any of the
surface areas, as this will cause deterioration of electrical components and
wiring insulation.
Note: if you don t use the unit for a long time,
please pull out the rubber plug to drain
the inside water out referring to right figure.
,
1.For the purpose of safety, please turn off the
Air Conditioner and cut off the power supply .
Cleaning The Unit
Introduction
1
WARNINGWARNING
This Air Conditioner is a new generation air conditioner ideal for
using in bedroom, study room, lobby, office, meeting room, warehouse,
attics, sports hall and other entertainment room. Its flexibility enable
easy adjustment to desirable room temperature and humidity. The
built-in filter can remove floating dust and purify air to create a healthy
working environment.

Safety Precaution
CAUTION
This symbol indicatesthe possibility of death
or serious injury.
This symbol indicatesthe possibility of injury
or damage to properties only.
!WARNING
!
Your safety and safety of others are very important. We have provided many
important safety messages in this manual and on your appliance. Always read
and obey all safety warnings.
!WARNING
Plug in the power socket properly.
Otherwise, it will cause electric shock or fire due to heat generation.
Do not stop the unit by pulling out the power cord .
CAUTION
!
When the air filter is to be removed, do not touch the metal parts
Of the unit.
They are sharpand may causean injury.
Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric
shock
.
When cleaning the unit switch the unit off, and unplug it.
The fan rotates at highspeed during operation,it may causean injury.
It will cause electric shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
It will cause electric shock or fire.
If the powercord is damaged,it must bereplaced by aqualified electrician to
avoid a hazard.
Do not modify power cord length or share the outlet with other appliances.
It will cause electric shock or fire due to heat generation.
Do not direct air flow at room occupants only.
This could leadto health problem.
211
Cleaning Air Filter
If the air filter is covered by dust,it will effect the performance of the Air
Conditioner, to obtain maximum performance its recommended that you clean
your filter every two weeks.
1.Turn off the air conditioner and cut off the power supply
2.Pull out the filter cover and remove the filter from cover.
3. Wash air filter in warm soap water .Do not
put air filter in the dishwasher or use any chemical
cleaners, ensure that the filteris completely dry
before use.
4.Attach the air filter to the filter cover using
the attachment hooks on the inner surface
of the cover. Put the filter cover back to its
place.
Maintenance
Your new Air Conditioner is designed to give you many years of dependable service.
This section tells you how to clean and care for your Air Conditioner properly.
It is recommended that you get your Air Conditioner serviced annually (at your own
cost).
Window kit installation
Your window kit has been design to fit most standard vertical and horizontal
window applications. However, it may be necessary for you to improvise or
modify some aspects of the installation procedure for certain types of window.
Please refer to fig.A &fig. B for minimum and maximum window openings.
Vertical
window
Window slide kit
minimum:67.5cm
maximum:125cm
Horizontal window
Window slide kit
minimum:67.5cm
maximum:125cm
Fig. A Fig. B
Fig. C
Note:The bolt and nut are used to fix window fixing board.
Nut
Bolt

Do not operate the unit without the air filter or when the front intake
grill has been removed.
Do not put a pets or plants where it will be exposed to direct air flow.
Do not usethis AirConditioner to preserveprecision devices, food, pets,
plants, and artobjects. It maycause deterioration ofquality.
It could cause dust to accumulate on the heat exchanger.
This could harmthe pets orplants.
Do not use for special purpose.
Do not apply flammable spray.
DO NOT place anything onthe top of the unit.
It may causea fire ordeformation of the cabinet.
3
10
Note: 1.The duct canbe compressed to450mm minimum andextended to
1800mm maximum. It is better to keep the ductlength to aminimum.
2. Stretching or bending the duct excessively will affect the cooling
efficiency, as seen below.
Do not!
1. Put areside of ductto
the exhaust air outlet
of mobile air conditioner,
According fix it with unit
correspondingly, then
turn right, Push it
downwards, make
sure that it is
fixed thoroughly.
Adaptor
Duct mount instruction
Yes!
1. Unclip windowoutlet 1 bypulling upwards.
2 .Insert andclip window outlet2 to theunit.
Note: DO NOT throw window outlet 2 out as
its required for the heating mode.
REFER TO ATTACHMENT CHANGES REQUIRED.
Unit
The i window outlet for heating.nstallation
3. Put the adaptor
subassembly
to a nearby
window.
2. Put the other sideof the duct
to adaptor.
1
2
1
2
Children should be supervised to ensure that they do not play with the appliance.
This appliance isnot intended foruse by persons(including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of theappliance by aperson responsible fortheir safety.
(For cooling mode) (For heating mode)
Window outlet 2
Window outlet 1

9
Installation
2.A minimum clearance of 50cm from walls
or other obstaclesshould be kept.
3.The gradient can't be more than 10 degrees
with the horizontal plane while putting
and using the utensil
Note:
2.The plug shall be accessible after the unit is positioned
1. Install the Air Conditioner in a flat and
spacious location where the air outlets will
not be obstructed.
1. DO NOT place Air Conditioner in the laundry
Morethan 50cm
Deal with water condensate
When the inside water tank is full, the water
full indicator flahes..
1.Open the drain cover and extract it upwards.
2.Place one container or drain cover under the
drain pipe, take off the plug on the drain pipe
and let out the condensing water.
3. Once all the condensing water is out , put
the plug back onto the drainage outlet, then
cover the drain cover.
IMPORTANT: This water is not suitable for
drinking.
Select a Location
Drain outlet
Morethan 50cm
4
Technical Specifications
Note: 1.The above cooling capacity is calculated at ambient temperature DB 30 , WB 25.4 .
2. The working temperature range of the air conditioner is 18~35.
Model
Cooling
capacity (W)
Air flow
3
(m /h)
Rated Cooling/
Heating current (A)
Rated Cooling/
Heating power (W)
Power supply
Refrigerant
Weight (kg)
Noise dB(A)
Dimension
(mm)
Suitable room
2
area (m )
830 486 320
F3.15AL (250V 3.15A)
Type of
the fuse
Heating
capacity (W)
AM-H12A4/SR1
3400
2800
5.65\5.35
1600
220-240V~/50Hz
35
50
14-20
Max. power
consumption (W)
Max. Running
current (A)
6.09
1300\1230
450
R410A

5
Parts Description
FRONT VIEW
Remote control
REAR VIEW
Circulation Mode
1. Press MODEbutton in asequence until the "FAN" displayappears..
2. Press the FAN button to select the fan speed.
3. Press the ON/OFF button to start the unit and press it again to stop.
Timer Operation
1. Press the TIMER button .
2. Press the + and - button to adjust your timer time.
Drying Mode
1. Press theMODE button ina sequence until the "DRY" display appears..
2. The fan will run at a fixed speed at this operation mode.
3. Close windowsand doors for the best dehumidifying effect.
4. Press ON/OFF button to start the unit and press it again to stop.
8
Before Starting the Unit
1. Select a suitable location, make sure the unit is near to an electrical outlet.
2. Install the flexible exhaust hose and the adjustable window slider kit.
3. Plug the unit into a right outlet.
4. Plug one end of drain pipe into the water full auto-drain outlet and plug the
other end plug into the windows installation board .
5. Turn the unit on.
Cooling Mode
1.Press the MODE button in a sequence until the "COOL" display appears..
2.Press the + and - button to set your desired set temperature.
3.Press FAN button to select the fan speed.
4.Press ON/OFF button to start the unit and press it again to stop.
Heating Mode
1.Press the MODE button in a sequence until the "HEAT" display appears..
2.Press the + and - button to set your desired set temperature.
3.Press FAN button to select the fan speed.
4.Press ON/OFF button to start the unit and press it again to stop.
Attention: In heat mode ,you need to replace the location of the shutters and
the exhaust pipe, see page 9 "installation" to replace the shutters".
Note: Time off is effective only when the air-conditioner is running.
Time on is effective only when the air-conditioner is stopping.
Operation
Failure to follow the below precaution could result in electrical shock,
fire or personal injury.
1.The plug must be plugged into an outlet that is properly installed and
grounded.
2.Do not use an extension cord or plug adaptor with this unit.
WARNING
Handle recess
Handle recess
Control panel
Air outlet
Air outlet
Castors
Front panel
Air inlet
Air inlet
Rear panel
Drain outlet
Signal receiver
windows
Window outlet 1
Window outlet 2
SET TEMPERATUR()
SET
ON/OFF
MODE
CLEAN
SPEED
SLEEP
LOCK
HEATER
SWINGDUST
SWING2
HEALTH
FUNGUSPROOF
SCREEN
TIMER
AUTO FAN
COOL HIGH
DRY MID
HEAT LOW

Accessories
6
Parts Parts name Quantity
Duct
Adaptor
Windows installation board
Alkaline batteries
Remote control
1
1
2
1
1
bolt 1
nut 1
7
Control Panel
1
2
2
3
56
4
m
i
k
j
b
h
d
e
f
g
a
1.ON/OFF button
2. +or -button
3.MODE button
4.TIMER button
5.FAN button
6.LOCK button
This button toallows you toturn the unit"ON" or "OFF".
Press the + or - button to set the room temperature.
Each time youpress this button,it allows youto select " COOL", "DRY" and FAN
in sequence.
Pressing this button activates and deactivates the timer.
This button allowsyou to selectedthe fan speed from "LOW ", "MED " and "HIGH".
in sequence.
Pressing this button, allows you to lock and unlockall functions of the unit.
Function buttons
Note :1. The Sleep function and Auto fan speed can only be selected by remote
control, all other functions can be operated via the control panel and remote control.
1
Window outlet 2
(
down
of )
The components placed
at the bottom of the
bubble packaging
Function display
a indicator
b-TEMP. indicator
d indicator
e-Med speed indicator
f indicator
indicator
g indicator
h-Running indicator
i-Cool indicator
j-Dry indicator
k
eating indicator(cold wind type unit
with out this )
-Time
-Low speed
-High speed
f-Circulation
-Lock
-Fan indicator
m-H
display
SET TEMPERATUR( )
SET
ON/OFF
MODE
CLEAN
SPEED
SLEEP
LOCK
HEATER
SWING DUST
SWING2
HEALTH
FUNGUSPROOF
SCREEN
TIMER
AUTO FAN
COOL HIGH
DRY MID
HEAT LOW
Table of contents