AUTOMATIC OPERATION
Pump switch-on
Whenever water comes into continuous contact with both sensors for longer than 5 seconds, the bilge pump
switches on.
Pump Switch-off
When one or both sensors are no longer in contact with water for longer than 5 seconds, a 15 second pump
switch-off period will begin. After this period has elapsed, the pump will switch off.
Battery save function
Whenever the power supply falls below 9V DC (for 12V DC systems) or is in the range of 15V and 20V DC (for 24V
DC systems), the 5302 will not permit bilge pump switch-on
Manual Operation
Manual pump switch-on
This button (optional) permits the bilge pump to be switched on manually. Pressing this button for more than 1
second and then releasing it switches the bilge pump on. In the same way, if the button is pressed again, the
pump will switch off. After 8 minutes of continuous operation, the pump switches off automatically and the
5302 returns to automatic mode.
NOTIFICATION SIGNS
The following signals are provided only if the LED or the remote control panel has been installed (optional).
Once power supply has been connected, the LED will light up for 2 seconds continuously in order to indicate the
operating status described in the table below:
AUTOMATIC OPERATION
MAINTENANCE - TECHNICAL DATA
MODEL 10 A
Current carrying of the relay contacts
(Max)
10 A
Supply Voltage (1)
Current absorbed when idling
9 ÷ 31 Vdc
7,5mA (Typical value)
Operating temperature
Degree of protection
from - 15 to + 70°C
IP68
Switch-on delay
Switch-off delay
5 Sec
20 Sec
Casing material
Dimensions (W x H x D)
Weight
EMC Class
Nylon
75 x 83 x 38 mm
415 g
EN 60945 - FCC Part 15 Rules 47
OUTPUT CHARACTERISTICS
INPUT CHARACTERISTICS
AMBIENT CHARACTERISTICS
GENERAL
GENERAL CHARACTERISTICS
(1) Except zone 15-20v DC battery save function for 24V DC systems
MAINTENANCE
Clean the stainless steel sensors periodically in order to ensure the regular operation of the 5302.
OPERATING STATUS
LED STATE
The LED is off
The LED shows slow flashes
The LED is almost always lit
up and switches off only
briefly
The LED is always lit up
Rapidly flashing LED
OTHER SIGNALS
The LED shows two quick
flashes briefly
LED STATE
The LED shows three quick
flashes
DESCRIPTION
No power supply voltage is present
Absence of water and pump switched off
Presence of water and pump is switched on
Manual operation by button and pump switched on even in the absence of water (8 minute
maximum duration)
Switch-on or switch-off delay
DESCRIPTION
Battery save function. Whenever the power supply falls below 9V DC (for 12V DC systems)
or is in the range of 15V and 20V DC (for 24V DC systems), the 5302 will not permit bilge
pump switch-on. Check both the level of charge of the batteries and the correct sizing of
the power supply cables.
Prolonged pump working condition.
The sensor will continue signalling the presence of water for 8 minutes after switch-on.
This signal may indicate:
- normal system behaviour
- a problem linked to the correct working condition of the pump
- the need to service the 5302
- prolonged presence of water where the 5302 is installed