6
Oceanic Saunas Ltd, Pountney Street, Wolverhampton, WV2 4HX
Chapter Three: Installation and operation
Installation
1. The steam generator must be installed upright. Position to the mini steam generator to
prevent accidental contact during operation and to avoid direct contact with the steam
rising from the generator during use.
2. Connect the equipment to the power supply with a suitable cable
General Operation
The mini steam generator is designed to increase the humidity in the sauna cabin and can be
used with both traditional and infra red sauna heaters; it also allows the use of aromatherapy
water based oils which can add a further dimension to the enjoyment of the sauna bath –
normally users will find their own level of comfort for temperature and humidity; we suggest
all users start with a reduced cabin temperature when using the mini steamer remember hot
air rises so the temperature and humidity may be much higher at the roof of cabin than on the
lower benches.
Always start with the lower power settings and only increase the power when you are happy
with the comfort level –higher power levels may only be suitable for larger cabins.
1. Carefully fill the boiler (for the first use this will be around 1200ml), press the On/Off
button to turn on, both the power indicator and water level indicator lights will turn on as
follows; light C is red water level is too low to operate, light B is green add water light C
is orange water level is at full –stop filling –do not over fill.
2. The heat light will turn on 5 seconds after the B light turns on (green). That means the
equipment is under heating situation.
3. The power of this equipment can be adjust among three levels by the “Power ”key. The
power level will keep the same with last time when you turns on the equipment by On/Off
key. But the power will return to the lowest level if the power is cut off and be connected
again (The default power is the lowest level).
4. When the indicator light B begins to flash, the equipment will alternate between on and
off as well as the indicator light “Heat”, that means the water level is too low and you
should fill water into the equipment (about 350ml).
5. Aromatherapy –concentrated water based oils may be dropped onto the V shaped top
plate of the boiler to evaporate on contact with the steam.
6. After use we recommend all air vents and the sauna cabin door left completely open for a
period to allow all extra humidity to disperse and avoid condensation.
Maintenance periodically check the boiler for build up of deposits such as lime-scale and if
necessary uninstall and de-scale using a solution of mild acid such as citric acid crystals.
Warranty this product is guaranteed for a period of 12 months from the date of purchase –
excluding consumable parts such as light bulbs and heating elements.