Cooling
The centrifugal blowers provide the necessary cooling of the amplifier, even during long contests. The
main blower is activated by switching the PA on and it is turned off when after-cooling is finished
(approx. 1-5 min after switching off the PA depending on the temperature of the tube). The
supplemental fan is turned on depending on the temperature of the air exiting from the amplifier. It is
switched on at 70°C and switched off at 60°C.
Operation
Operating elements (see photo of front panel)
TUNE - Anode capacitor for tuning, tuning of higher frequencies to "0",
lower frequencies to „100“.
LOAD -Output capacitor tunes antenna load resistance to amplifier.
Capacity is low at „0“ and high at "100" on the scale.
OFF - You switch off the amplifier by pressing this button.
ON - You switch on the amplifier by pressing this button.
Heating of tube is on and after 3min of delay the amplifier will be
ready for operation.
OPR/STBY - „OPERATE“ you will be ready for operation.
At STBY, if WAIT-LED is on or the amplifier is off your transceiver is in
bypass-mode directly connected to antenna. Maximum 400Watts !
RF OUTPUT - Bar graph –shows output power .
REFLECTED POWER -Bar graph –shows reflected power of the antenna. 350W
maximum or amplifier switches to STANDBY-mode
Ig2 bargraph –measerus the currency of the second grid in the range from -20mA to
+80mA
HV/IP/TUNE bargraph –measure the anode voltage, anode currency or tuning of the amplifier
TUNING
The OM3006 amplifier is operated in class AB. Thus it’s possible to obtain a maximum output
power at an excellent linearity. For this purpose the amplifier has to be tuned carefully.
The operation of a mistuned PA will cause malfunctions, the increase of grid current (the GRID-
MAX-LED will light up) and problems with TVI/BCI.
The grid-current is shown with 2 LED diodes. It’s normal if the green LED is flashing or may be
shining a little bit during peak operation. If you overload the amplifier the output power increases the
grid current at very small rates and the red GRID-MAX-LED is shining and the safety devices switch
the PA to STBY, you have overloaded the amplifier and must decrease the output.