Omron HEM-7154-E User manual

Instruction Manual 1
Automatic Upper Arm Blood Pressure Monitor
M3 (HEM-7154-E)
Symboles/ Symbole/ Simboli/ Símbolos/
Symbolen/ Символы/ Semboller/
ίϣέϟ
Read Instruction manual and before use.
FR Lire le mode d’emploi et avant l’utilisation.
DE Lesen Sie vor der Verwendung die Gebrauchsanweisung und .
IT Leggere il manuale di istruzioni e prima dell’uso.
ES Lea el manual de instrucciones y antes del uso.
NL Lees de gebruiksaanwijzing en voor gebruik.
RU
Прочтите руководство по эксплуатации и перед использованием.
TR Kullanmadan önce, kullanım kılavuzu ve 'yi okuyun.
ϡΩΧΗγϻϝΑϗ ϭ ΕΩΎηέϹϝϳϟΩέϗAR

EN1
EN
1. Introduction
Thank you for purchasing the OMRON Automatic Upper Arm Blood
Pressure Monitor. This blood pressure monitor uses the oscillometric
method of blood pressure measurement. This means this monitor
detects your blood movement through your brachial artery and
converts the movements into a digital reading.
1.1 Safety Instructions
This instruction manual provides you with important information
about the OMRON Automatic Upper Arm Blood Pressure Monitor.
To ensure the safe and proper use of this monitor, READ and
UNDERSTAND all of the safety and operating instructions. If you do
not understand these instructions or have any questions, contact
your OMRON retail outlet or distributor before attempting to
use this monitor. For specific information about your own blood
pressure, consult with your physician.
1.2 Intended Use
This device is a digital monitor intended for use in measuring blood
pressure and pulse rate in adult patient population. The device detects
the appearance of irregular heartbeats during measurement and
gives a warning signal with readings. It is mainly designed for general
household use.
1.3 Receiving and Inspection
Remove this monitor from the packaging and inspect for damage. If
this monitor is damaged, DO NOT USE and consult with your OMRON
retail outlet or distributor.
2. Important Safety Information
Read the Important Safety Information in this instruction manual
before using this monitor. Follow this instruction manual thoroughly
for your safety.
Keep for future reference. For specific information about your own
blood pressure, CONSULT WITH YOUR PHYSICIAN.
2.1 Warning Indicates a potentially hazardous
situation which, if not avoided, could
result in death or serious injury.
• DO NOT use this monitor on infants, toddlers, children or persons
who cannot express themselves.
• DO NOT adjust medication based on readings from this blood pressure
monitor. Take medication as prescribed by your physician. ONLY a
physician is qualified to diagnose and treat high blood pressure.
• DO NOT use this monitor on an injured arm or an arm under medical
treatment.
• DO NOT apply the arm cuff on your arm while on an intravenous
drip or blood transfusion.
• DO NOT use this monitor in areas containing high frequency (HF)
surgical equipment, magnetic resonance imaging (MRI) equipment,
computerized tomography (CT) scanners. This may result in incorrect
operation of the monitor and/or cause an inaccurate reading.
• DO NOT use this monitor in oxygen rich environments or near
flammable gas.
• Consult with your physician before using this monitor if you have
common arrhythmias such as atrial or ventricular premature beats
or atrial fibrillation; arterial sclerosis; poor perfusion; diabetes;
pregnancy; pre-eclampsia or renal disease. NOTE that any of these
conditions in addition to patient motion, trembling, or shivering may
affect the measurement reading.
• NEVER diagnose or treat yourself based on your readings. ALWAYS
consult with your physician.
• To help avoid strangulation, keep the air tube and AC adapter cable
away from infants, toddlers and children.
• This product contains small parts that may cause a choking hazard if
swallowed by infants, toddlers and children.
AC Adapter (optional accessory) Handling and Usage
• DO NOT use the AC adapter if this monitor or the AC adapter cable is
damaged. If this monitor or the cable is damaged, turn off the power
and unplug the AC adapter immediately.
• Plug the AC adapter into the appropriate voltage outlet. DO NOT
use in a multi-outlet plug.
• NEVER plug in or unplug the AC adapter from the electric outlet
with wet hands.
• DO NOT disassemble or attempt to repair the AC adapter.

EN2
EN
Battery Handling and Usage
• Keep batteries out of the reach of infants, toddlers and children.
2.2 Caution
Indicates a potentially hazardous situation
which, if not avoided,may result in minor
or moderate injury to the user or patient or
damage to the equipment or other property.
• Stop using this monitor and consult with your physician if you
experience skin irritation or discomfort.
• Consult with your physician before using this monitor on an arm
where intravascular access or therapy, or an arteriovenous (A-V)
shunt, is present because of temporary interference to blood flow
and could result in injury.
• Consult with your physician before using this monitor if you have
had a mastectomy.
• Consult with your physician before using this monitor if you have
severe blood flow problems or blood disorders as cuff inflation can
cause bruising.
• DO NOT take measurements more often than necessary because
bruising, due to blood flow interference, may occur.
• ONLY inflate the arm cuff when it is applied on your upper arm.
• Remove the arm cuff if it does not start deflating during a
measurement.
• DO NOT use this monitor for any purpose other than measuring
blood pressure.
• During measurement, make sure that no mobile device or any other
electrical device that emit electromagnetic fields is within 30 cm of
this monitor. This may result in incorrect operation of the monitor
and/or cause an inaccurate reading.
• DO NOT disassemble or attempt to repair this monitor or other
components. This may cause an inaccurate reading.
• DO NOT use in a location where there is moisture or a risk of water
splashing this monitor. This may damage this monitor.
• DO NOT use this monitor in a moving vehicle such as in a car or on an
aircraft.
• DO NOT drop or subject this monitor to strong shocks or vibrations.
• DO NOT use this monitor in places with high or low humidity or high
or low temperatures. Refer to section 6.
• During measurement, observe the arm to ensure that the monitor is
not causing prolonged impairment to blood circulation.
• DO NOT use this monitor in high-use environments such as medical
clinics or physician offices.
• DO NOT use this monitor with other medical electrical (ME)
equipment simultaneously. This may result in incorrect operation of
the monitor and/or cause an inaccurate reading.
• Avoid bathing, drinking alcohol or caffeine, smoking, exercising and
eating for at least 30 minutes before taking a measurement.
• Rest for at least 5 minutes before taking a measurement.
• Remove tight-fitting or thick clothing from your arm while taking a
measurement.
• Remain still and DO NOT talk while taking a measurement.
• ONLY use the arm cuff on persons whose arm circumference is
within the specified range of the cuff.
• Ensure that this monitor has acclimated to room temperature before
taking a measurement. Taking a measurement after an extreme
temperature change could lead to an inaccurate reading. OMRON
recommends waiting for approximately 2 hours for the monitor to
warm up or cool down when the monitor is used in an environment
within the temperature specified as operating conditions after
it is stored either at the maximum or at the minimum storage
temperature. For additional information on operating and storage/
transport temperature, refer to section 6.
• DO NOT use this monitor after the durable period has ended. Refer
to section 6.
• DO NOT crease the arm cuff or the air tube excessively.
• DO NOT fold or kink the air tube while taking a measurement. This
may cause an injury by interrupting blood flow.
• To unplug the air plug, pull on the plastic air plug at the base of the
tube, not the tube itself.
• ONLY use the AC adapter, arm cuff, batteries and accessories
specified for this monitor. Use of unsupported AC adapters, arm cuffs
and batteries may damage and/or may be hazardous to this monitor.
• ONLY use the approved arm cuff for this monitor. Use of other arm
cuffs may result in incorrect readings.
• Inflating to a higher pressure than necessary may result in bruising
of the arm where the cuff is applied. NOTE: refer to“If your systolic
pressure is more than 210 mmHg” in section 11 of instruction
manual for additional information.
• Read and follow the“Correct Disposal of This Product” in section 7 when
disposing of the device and any used accessories or optional parts.

EN3
AC Adapter (optional accessory) Handling and Usage
• Fully insert the AC adapter into the outlet.
• When unplugging the AC adapter from the outlet, be sure to safely
pull from the AC adapter. DO NOT pull from the AC adapter cable.
• When handling the AC adapter cable:
Do not damage it. / Do not break it. / Do not tamper with it.
DO NOT pinch it. / Do not forcibly bend or pull it. / Do not twist it.
DO NOT use it if it is gathered in a bundle.
DO NOT place it under heavy objects.
• Wipe any dust off of the AC adapter.
• Unplug the AC adapter when not in use.
• Unplug the AC adapter before cleaning this monitor.
Battery Handling and Usage
• DO NOT insert batteries with their polarities incorrectly aligned.
• ONLY use 4 “AA” alkaline or manganese batteries with this monitor.
DO NOT use other types of batteries. DO NOT use new and used
batteries together. DO NOT use different brands of batteries together.
• Remove batteries if this monitor will not be used for a long period of
time.
• If battery fluid should get in your eyes, immediately rinse with
plenty of clean water. Consult with your physician immediately.
• If battery fluid should get on your skin, wash your skin immediately
with plenty of clean, lukewarm water. If irritation, injury or pain
persists, consult with your physician.
• DO NOT use batteries after their expiration date.
• Periodically check batteries to ensure they are in good working
condition.
2.3 General Precautions
• When you take a measurement on the right arm, the air tube should
be at the side of your elbow. Be careful not to rest your arm on the
air tube.
• Blood pressure may differ between the right and left arm, and
may result in a different measurement value. Always use the same
arm for measurements. If the values between both arms differ
substantially, check with your physician on which arm to use for
your measurements.
Remember to have a record of your blood pressure and pulse
readings for your physician. A single measurement does not provide
an accurate indication of your true blood pressure.
Please use the Blood Pressure Diary to keep records of several
readings over a certain period of time. To download PDF files of the
diary, visit www.omron-healthcare.com.

EN4
EN
3. Error Messages and Troubleshooting
If any of the below problems occur during measurement, check to make sure that no other electrical device is within 30 cm. If the problem persists,
please refer to the table below.
Display/Problem Possible Cause Solution
appears or the
arm cuff does not
inflate.
The [START/STOP] button was pressed
while the arm cuff is not applied.
Press the [START/STOP] button again to turn the monitor
off. After inserting the air plug securely and applying the
arm cuff correctly, press the [START/STOP] button.
Air plug is not completely plugged
into the monitor.
Insert the air plug securely.
The arm cuff is not applied correctly.
Apply the arm cuff correctly, then take another
measurement. Refer to section 5 of instruction manual .
Air is leaking from the arm cuff. Replace the arm cuff to the new one. Refer to section 12
of instruction manual .
appears or a
measurement
cannot be
completed after the
arm cuff inflates.
You move or talk during a
measurement and the arm cuff does
not inflate sufficiently.
Remain still and do not talk during a measurement. If
“E2”appears repeatedly, inflate the arm cuff manually
until the systolic pressure is 30 to 40 mmHg above your
previous readings. Refer to section 11 of instruction
manual .
Due to the systolic pressure is above
210mmHg, a measurement cannot
be taken.
appears
The arm cuff is inflated exceeding the
maximum allowable pressure.
Do not touch the arm cuff and/or bend the air tube while
taking a measurement. If inflating the arm cuff manually,
refer to section 11 of instruction manual .
appears
You move or talk during a
measurement. Vibrations disrupt a
measurement.
Remain still and do not talk during a measurement.
appears The pulse rate is not detected
correctly.
Apply the arm cuff correctly, then take another
measurement. Refer to section 5 of instruction manual .
Remain still and sit correctly during a measurement.
If the “ ”symbol continues to appear, we recommend
you to consult with your physician.
//
appears
does not flash during
a measurement
Table of contents
Other Omron Blood Pressure Monitor manuals

Omron
Omron R5 Prestige User manual

Omron
Omron BP710CANN User manual

Omron
Omron HEM-7132 User manual

Omron
Omron HEM-SOLAR User manual

Omron
Omron SYSDRIVE MX2 SERIES User manual

Omron
Omron M3 Intellisense User manual

Omron
Omron R1 User manual

Omron
Omron RX - 1 User manual

Omron
Omron HEM-7120 User manual

Omron
Omron M2 Compact User manual

Omron
Omron M2 Compact User manual

Omron
Omron M10-IT User manual

Omron
Omron HEM-6121 User manual

Omron
Omron T9P User manual

Omron
Omron HEM-7320T-CA User manual

Omron
Omron M2 Compact User manual

Omron
Omron IntelliSense HEM-712C User manual

Omron
Omron HEM-7112 User manual

Omron
Omron X7 Smart User manual

Omron
Omron MIT Elite Plus User manual