Open House ChannelPlus H636 User manual

ChannelPlus model H636
5 Port Ethernet Switch 10/100 BASE-T
12345
TM
Power
12-15VDC 300mA
ON - 100Mbps
OFF - 10MBps
ON - Connected
BLINK - Activity
Use crossover cable for link
ChannelPlus model H636
5 Port Ethernet Switch 10/100 BASE-T
12345
TM
Power
12-15VDC 300mA
ON - 100Mbps
OFF - 10MBps
ON - Connected
BLINK - Activity
Use crossover cable for link
ChannelPlus model H636
5 Port Ethernet Switch 10/100 BASE-T
12345
TM
Power
12-15VDC 300mA
ON - 100Mbps
OFF - 10MBps
ON - Connected
BLINK - Activity
Use crossover cable for link
The H636 10/100Base-T ethernet switch creates a home network
for two to five computers. “Plug and play” installation is easy when using the
H628 data hub. The H636 is fully IEEE802.3 compliant and has activity LEDs
for network status and speed.
The H636 requires no
programming and starts working
at power up with no user
intervention.
ChannelPlus Fast Ethernet Switch
1
2
3
1) Hook from the top
2) Swing into place
3) Push button to lock
OpenHouse modules attach from the top
tm
ChannelPlus model H616
Telephone Master Hub (4 linesx6phones)
Telephone Master Hub (4 lines x 6 phones)
Telephones
From
Telco
From
Telco
RJ31X
Out
Expansion
Ports
Expansion
Ports
R
T
R
T
4
R
T
R
T
3
R
T
R
T
2
R
T
R
T
1
Typical Installation
Expanding the Network
Wiring the H636 Hub
- Use only Category 5 unshielded twisted-pair cable.
- When connecting to an H628 or a network device directly, use
straight through RJ-45 cables.
- Each run to a network device should be less than 100 meters (328
feet).
DECLARATION OF CONFORMITY
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2)
THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY
CAUSE UNDESIRED OPERATION.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used according to the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which if found by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna
-Increase the separation between the equipment and receiver.
-Connect the equipment to an outlet other than the receiver’s outlet.
-Consult a dealer or an experienced radio/TV technician for assistance.
Power supply
LED Indicators
Network Interface
model number
105-125 VAC
Link/Activity, Speed
Use crossover cable
300mA maximum
15 VDC unregulated
Power
5
350-099
input power
each port
RJ-45 uplink
output voltage
each unit
RJ-45 ports
output current
Environmental
Compliance
operating temperature
IEEE 802.3
0°C to 50°C
100Base-T
Max cable length CAT-5 (UTP) 100 meters (328 feet)
Specifications: typical @ 25 C ± 5 C
OO H636
Ethernet Hub BASE-T (5 RJ-45 inputs, 1 uplink)10
+5VDC
ChannelPlus model H628
Data Hub (8 cables, TIA-568A) Category 5 Compliant
H628
Straight-through cable
(H691 or H692)
H636
Ethernet hub
H636
Ethernet hub
Ethernet connections for 4 rooms
}
To data jacks
in remote
wall plates
Uplink 5
4321
+5VDC
Using more than one hub
Crossover cable
- Use only Category 5 unshielded twisted-pair cable.
- The cable length between two hubs cannot exceed 100 meters
(328 feet).
- Additional hubs may be used as long as the path between any
two network devices does not exceed four hubs and five cables.
- All hubs used must be powered.
-A crossover cable exchanges the In and Out connections on one
end. This will convert any standard port into a “link” port.
Connecting two H636s or connecting an H636 to most firewalls
will require using a crossover cable.
ChannelPlus model H636
5 Port Ethernet Switch 10/100 BASE-T
12345
TM
Power
12-15VDC 300mA
ON - 100Mbps
OFF - 10MBps
ON - Connected
BLINK - Activity
Use crossover cable for link
ON - 100Mbps
OFF - 10Mbps
ON - Connected …
A working device is connected to this port.
BLINK - Activity …
Data is being transmitted or received by this port.
To Internet
Crossover cable
(typical)
Internet gateway
or firewall
H636
Ethernet hub
Crossover cable
LED Indicators
Ethernet switches
The H636
The H636
are superior to ordinary Ethernet hubs in that they
segment the data traffic. Computer A can talk to computer B while computers
C and D also talk. Collisions are eliminated. Throughput is greatly enhanced.
learns the addressing of your network with no programming.
will automatically detect 10 base-T or 100 base-T adaptors on a
port by port basis. The H636 will use the highest possible speed.

multiplex
technology, inc.
®
***
3001 Enterprise Street, Brea, CA 92821-6213, U.S.A.
714-996-4100 800-999-5225 FAX 714-996-4900 www.openhousesystems.com
TM
ChannelPlus®
Ethernet Switch, 10/100Base-T
Model H636
OpenHouse Enclosures, Modules,
Accessories & Wall Plates
ChannelPlus model H628
Data Hub (8 cables, TIA-568A) Category 5 Compliant
OUT
IN
532-230 5MHzto 1000MHz
OUT
IN
OUT
IN
OUT
IN
OUT
IN
SPLITTER
COMBINER
R
TelephonesFrom
Telco
ChannelPlus model H801
Combo Hub (2 lines x 6 phones, 1input x 4 televisions)
R
T
2
R
T
1
ChannelPlus model H616
Telephone Master Hub (4 lines x 6 phones)
Telephones
From
Telco
RJ31X
Out
Expansion
Ports
R
T
4
R
T
3
R
T
2
R
T
1
Starter systems
RF splitters and telephone punch
downs. When it is time to upgrade,
just snap this module out and
replace with one of more of the
more sophisticated units.
Data hubs
Termination blocks for the CAT-5 cables,
Ethernet hubs. Bring the Internet to any
room in the home. Or create a home data
network.
Telephone hubs
Connections for 1-4 phone lines to
every room. Starter hub adds RJ-
31X jack for security system dialer.
Coax panels
Distribute antenna or cable TV to every
room of the house. Some models include
bi-directional amplifiers for interactive cable
systems. Some models include
IR engines.
modulator
inputs and
AV modulators
(for service center)
Create a new TV channel for a front
door camera. Some models feature
Cat-5 input connections.
Warranty
Multiplex Technology, Inc. warrants this product to be free from defects in materials and workmanship
for a period of one year from the date of purchase or MTI will repair, or at its option, replace the
defective product. To obtain warranty service, call MTI for a return material authorization (RMA)
number and return the product prepaid to Multiplex Technology, Inc., 3001 Enterprise Street, Brea, CA
92821, Attention: Customer Service. Please put the RMA number on the outside of the carton.
Any implied warranty arising from the sale of the product including implied warranties of
merchantability and fitness for purpose are limited to the warranty stated above. MTI shall not be
responsible for losses or damages or expenses, whether direct, consequential or incidental arising
from the use of or the inability to use this product. Some states do not allow limitations on how long the
implied warranty lasts or the exclusion or limitation or incidental or consequential damages, so the
above limitations and exclusions may not apply to you. This warranty gives you specific legal rights,
and you may have other rights which may vary from state to state.
TM
Compatible
Service center
enclosures
A full line of OpenHouse compatible
enclosures, from simple, inexpensive
mounting plates to high capacity in-wall
cabinets. AC outlets can be mounted
inside the cabinets using a UL listed
accessory.
AV modulators
(for media center)
Create new TV channels for DVD, VCR,
or a satellite receiver. These modulators
sit in the media center. Some offer true
MTS stereo.
®
model 5445 quad digital modulator
pll frequency control
D
C
BA
program
select
Wall plates
Wall plate systems for all rooms. The typical room gets TV
and telephone. The Home office wall plate adds data ports.
The media center wall plate adds satellite feeds.
IR Accessories
Control video devices from any room.
New Open House products are added all the time.
Visit our website to learn more:
www.openhousesystems.com
Wiring a house for OpenHouse
Typical Room Media Center Home Office
Good
Better
Best
1 Cat-5
1 RG-6
1 Cat-5
3 RG-6
1 Cat-5
2 RG-6
2 Cat-5
1 RG-6
2 Cat-5
2 RG-6
2 Cat-5
3 RG-6
3 Cat-5
3 RG-6
2 Cat-5
2 RG-6
3 Cat-5
3 RG-6
Good ...
Typical room - phone, TV
Media center - phone, satellite receiver, AV modulators
Home office - phone, TV,
Better …
Typical room - phone, TV, ethernet
Media center - phone, TV, satellite receiver, AV modulators
Home office -
Best …
cable modem
ethernet,
phone, TV, ethernet, cable modem
Typical room - phone, TV, ethernet, satellite receiver
Media center - phone, TV, ethernet, satellite receiver, AV modulators, hi-speed data
Home office - phone, TV, ethernet, satellite receiver, cable modem, hi-speed data
The cables in an OpenHouse run from the various rooms of the house
directly to the service center location.(This is known as ‘home run’
wiring.) Two types of wire are used for communication and
entertainment: Cat-5, 4-UTP (4 nshielded wisted airs) wire handles
data or 1 to 4 telephone lines. RG-6 coax handles television (antenna or
cable), satellite dish, cable modem, or AV modulator signals. (An AV
modulator creates new TV channels for front door camera, DVD player, a
VCR or a satellite receiver.)
We recommend the following pre-wire schemes . Run these wires from
the service center to the rooms indicated.
UTP
Multiplex Technology, Inc., Brea, CA 92821Multiplex Technology, Inc., Brea, CA 92821
600-220 Rev. A600-220 Rev. A