Optex TR-20U User manual

2000
Reception/Transmission range must be changed according to environment.
Please check if system works properly for the site.
In the case of insufficient transmission range, add another TR-20U (Repeater unit) to
extend range.
Receiver/ Repeater
RC-20U/ TR-20U
Sensor unit
TD-20U
Repeater
TR-20U
Contact unit
TC-10U
Button unit
TS-10U
TR-20U INSTALLATION INSTRUCTIONS
REPEATER
Please read this manual carefully before installation.
2 PARTS IDENTIFICATION
1 CAUTION AND WARNING
4 INSTALLATION 5 POWER CONNECTION
6 TEACH TRANSMITTER CODES TO TR-20U “LEARN MODE”
3 RECEPTION/ TRANSMISSION (REFERENCE)
2000ft (Open field, line of sight)
150ft (Stucco/Plaster construction)
100ft (Concrete construction)
2000ft (Open field, line of sight)
150ft (Stucco/Plaster construction)
100ft (Concrete construction)
1400ft (Open field, line of sight)
150ft (Stucco/Plaster construction)
100ft (Concrete construction)
Wall Mounting
Use the mounting screw
on a wall. Leave some
length of the screw out
for mounting hole of the
TR-20U.
Desktop
Pull out the stand on the back
of the TR-20U and place it on
any flat surface.
Note:
・Verify that each transmitter has been successfully learned by TR-20U by triggering them.
・Single transmitter cannot be learned by multiple channel.
・TR-20U learned code will keep memorized even if turning OFF the power.
Erasing codes from TR-20U’s memory.
1) Hold down switch 1 until the power indicator starts to flash.
2) Press switch 2 until the appropriate channel indicator is lit.
3) Press switch 1 to erase. Channel indicator will start to flash.
4) Press switch 2 a few times until the power indicator stops flashing and remains lit.
A) The TR-20U automatically
starts in “LEARN MODE”
if no transmitter code has
been programmed.
OR
B) Press and hold switch 1
until the power indicator
starts to flash.
Use only the power adaptor supplied with the
product.
TR-20U
Mounting
hole
Stand
FRONT
Note: When you recycle this product, please disassemble product and recycle according to state law.
BACK
Channel indicator 1
Channel indicator 2
Channel indicator 3
Switch 1
Switch 2
Adaptor
Jack
Power
Switch
Power
indicator
Function
AC Adaptor
Mounting screw
Switch 1 Activating “LEARN MODE” and
“TEACH MODE”
Activating for making selection
Switch 2
Activate “LEARN MODE”
Teach the transmitter code to TR-20U
Channel 1 Channel 2 Channel 3 Channel 4
Activate the transmitter you wish to teach the receiver.
Receiver starts
in channel 1. Press switch 2 to advance to the next channel
and chime sound.
Press switch 2 to return to
normal operation status.
FEATURES
・Compatible with RC-20U (Chime box W/Relay), TD-20U (Indoor/Outdoor Sensor Transmitter), TS-10U
(Hand-Held Transmitter), TC-10U(Door/Window Transmitter) and also compatible with any units of
WIRELESS1000 series.
・Identifies the channel (location) by LED lights (4 channels).
・Able to learn 4 transmission codes.
・Automatic “Learning” function facilitates to preset transmission codes to TR-20U.
・Over 8 million codes possible, eliminates interference from neighbors.
・Low battery indicator to recognize transmission units’ battery status.
・Powered by a 9VDC adaptor(Included).
Erasing all codes from TR-20U. (Return to the factory default)
To erase all programming, turn on power while holding switch 1.
CAUTION
1. Impact/Shock
Impact or Shock can cause severe damage or break the TR-20U.
2. Electric Devices
Use TR-20U at least 3ft (1m) away from electronic devices such as TVs, Radios,
PCs, Microwave ovens, or any other device with an electric motors.
This may cause the unit to malfunction.
3. Transmission range
Transmission range may decrease under the following conditions:
- Either transmission units or TR-20U installed on a metal surface.
- Presence of a steel door, reinforced concrete or other metal obstructions between
transmission unit and TR-20U.
- Places near strong radio sources such as broadcast stations or substation.
4. Cleaning
Harsh cleaners such as paint removers or benzene may ruin the surface. Use a soft wet
cloth and mild soap to clean.
WARNING
1. Harsh environments
Do not use the TR-20U outdoors, severe conditions as out of warranted
temperature, rapid temperature change, high humidity, or steam.
This may cause the unit to malfunction.
2. Tampering
Any changes or modifications not expressly approved by OPTEX could void the user’s
authority to operate the equipment.
3. Adaptor
Do not use any other AC adaptor except what is included.
Each transmitter has a unique transmitter code which can be automatically learned by TR-20U.
The TR-20U’s channels must be taught to respond to the appropriate transmitter. (No transmitter is taught on default setting.)
Normal
Operation Status
Blink
Light

Unit: inches (mm)
1. The system is not
operating
Check the transmitter.
Does the status indicator light up when
you trigger the transmitter?
Check to see whether the battery is inserted correctly.
If the battery is old, replace it with a new one.
Is the status indicator of the transmitter flashing? The battery is old. Replace the battery.
Check the receiver.
Is the power indicator of the receiver lit? Is the receiver on? Check the wiring and connection.
Have all the transmitter codes had been
taught correctly?
Teach the transmitter codes correctly. The system will
not operate without this process.
Is the volume setting correct? Is the volume set to “0”? If so, readjust the volume.
Are there other high power appliances using the
same electrical power outlet?
Please connect the receiver to a different electrical
outlet.
The zone indicator of the receiver is on, but
nothing happens.
Check to see whether the terminal is properly
connected to other devices.
Are the zone indicators flashing slowly? Follow directions in LOW BATTERY INDICATION of
the receiver’s manual.
Are there other high power appliances using the
same electrical power outlet?
Please connect the receiver to a different electrical
outlet.
Are the channel indicators flashing slowly? Follow directions in 9 LOW BATTERY INDICATION.
Is there anything blocking the transmission? Relocate the receiver and/or the transmitter. Metal
objects can shorten the effective transmission range.
Is there anything blocking the transmission? Relocate the TR-20U and/or the transmitter. Metal
objects can shorten the effective transmission range.
2. The system is not operating correctly.
The TR-20U does not learn the transmitter
codes.
The TR-20U gets reception in the wrong channel.
Check whether the transmitter codes have already
been “learned” in a different channel. If so, erase the
memory and teach again.
Erase memory in the channel in which the RC-20U responds
and teach using the correct channel.
A certain zone seem to malfunction.
This is probably the transmitter’s problem. Check the transmitter
that corresponds to that channel.
Before contacting the supplier! Go through the setups again after turning on the
power while holding down switch 1.
•If the above solutions do not work, please contact your supplier for services.
Model
Description
Power Source
Frequency
Operating
Temperature
Installation Location
TR-20U
Repeater
9VDC (Exclusive AC Adaptor)
Power Consumption 3W Max. (Including AC Adaptor 120V,
60Hz)
Status Indicator
Power Indicator: Green
Channel Indicator: Red x 3
418MHz
15°F ~ 120°F (-10°C ~ +50°C)
Indoor
Accessories M
AC Adaptor x 1
ounting Screw × 1
Weight 6.0 oz (170g)
Specifications may change without notice.
7 TEACH TRANSMITTER CODES TO RECEIVER “TEACH MODE”
8TROUBLESHOOTING 9LOW BATTERY INDICATION
10 SPECIFICATION 11 DIMENSIONS
13 WARRANTY
12 COMPLIANCE
1. This product is warranted under normal use for 1 year from the date of purchase. If the
product proves to be defective, return it with a copy of your dated sales receipt for repairs or
replacement without charge.
2. The warranty is not applicable when below circumstances will be found:
• Mechanical or electrical modification(s) are made to the product or it is otherwise altered
manually.
• The product is already been serviced at place(s) other than the manufacturer.
• It is determined that the product malfunction has resulted from improper use or from an
accident.
• No copy of the dated sales receipt has been submitted together with the product to be
serviced.
FCC ID : DC9TR-10U
The changes or modifications not expressly approved by the OPTEX could void the user’s authority to operate the equipment. To
comply with the FCC RF exposure compliance requirements, this device and its antenna must not be co-located or operating to
conjunction with any other antenna or transmitter.Note: This equipment has been tested and found to comply with the limits for a Class
B Digital Device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction, may cause harmful interference to radio communication. However, there is no grantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures.(1)Reorient or relocate the receiving antenna. (2)Increase the separation between the equipment and
receiver.(3)Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.(4)Consult the dealer
or an experienced radio/TV technician for help.
IC : 4012A-000000TR20U
Operation is subject to the following two conditions.(1)this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that permitted for successful communication.
3.5 (88)
1.1
(28)
7.4 (188)
5.3 (134)
The receiver must be taught this transmitter code before use. Refer to the receiver’s manual for details.
1. Preparation of receiver
5. Verification
2. Activate “TEACH MODE”
OPERATION CHART for teaching TR-20U’s code to the receiver.
3. Select channel you wish to teach
TR-20U will automatically return to normal operation after 5 seconds without any operation.
Verify that the receiver has learned successfully by observing the channel
indicators of the receiver. Channel indicators should have stopped flashing and
remain continuously on.
* It will be skipped if no
transmitter code has
been programmed in
channel.
TR-20U starts
in channel 1.
Press switch 2 to advance to the
next channel.
Press switch 1 to transmit the transmitter code
Press switch 2 to return to
normal operation status.
Channel 1 Channel 2 Channel 3 Channel 4 Normal
Operation Status
Press switch 1 of the
receiver untill the power
indicator starts flashing.
Press switch 2 to select
the zone you wish to
assign to the TR-20U.
*Note
Receivers compatible
with TR-20U are RC-20U
of WIRELESS 2000
series and RC-10U/RG-
10U of WIRELESS 1000
series.
* After teaching all the
transmitter codes (If you
have multiple transmitters),
return the receiver to normal
operation status.
* Make sure that the
receiver operates correctly
with all the repeaters and
the transmitters.
Note:
Make sure to teach
TR-20U’s code to the
receiver after teaching
transmitter code to the
repeater.
Press switch 1 twice
within 2 sec to activate
“TEACH MODE”.
The power indicator
light down and
channel indicator
starts to flash.
4. Teach transmitter code
Once selected,
press switch 1 to
teach transmitter
code to receiver.
To select another
channel, press
switch 2 to select.
(Please refer
operation chart)
Press switch 2 to select channel.
Channel indicator start slow flashing whenever the
corresponding transmitters have low battery.
Any operation cannot be done until one of operations
below are conducted.
1) Replace transmitter’s batteries.
2) Press switch 2.
TR-20U will not need to relearn transmitter after replacing
the batteries.
5916560
Check the repeater.
Is the power indicator of the TR-20U lit? Is the TR-20U on? Check the wiring and connection.
Have all the transmitter codes had been
taught correctly?
Teach the transmitter codes correctly. The system will
not operate without this process.
This manual suits for next models