manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Optex
  6. •
  7. Security Camera
  8. •
  9. Optex InSight Series User manual

Optex InSight Series User manual

INS-QXI-ST
INS-QXI-ST
INSTALLATION INSTRUCTIONS
59-3061-1 2212-27
Quick Guide
1
2
3
4
5
- Specifications
- Dimensions
- Detection area
- Compliance
- How to reset to the factory default
Before installation
Others
<< Contents >>
Page
1
2
3
4
Step
Enable
Disable
Camera angle and PIR area settings
Installation
Device registration to CHeKT portal
DHCP
IP address settings
Checking
VISUAL VERIFICATION PIR CAMERA
Warning
Caution
Prohibition Recommendation
Failure to follow the instructions provided with this indication and
improper handling may cause death or serious injury.
Failure to follow the instructions provided with this indication and
improper handling may cause injury and/or property damage.
NOTE Special attention is required to the
section of this symbol.
- Accessories
- Manufacturer's statement
Before installation
Destroy
Disassemble
modify
Intentional watering
Warning Caution
Full information is available at
https://navi.optex.net/manual/50426
This “Quick Guide” is the part of the entire installation instructions
that guides the installation procedures for installers.
Get the full information of the installation instructions from the web site.
If you need a guide to the operation of the whole system, please
consult the installer of the entire system.
•
•
•
1
series
- Parts identification
4 x 20 mm
Mounting screws T20 Torx wrench
Waterproof cap
for LAN connection
PIR detector
Bracket angle adjusting screw
PIR cover Camera unit Camera angle adjusting screw
Back cover
Mounting plate
PIR area masking strips
InSIght Camera manual
https://navi.optex.net/manual/50426/en/?type=cameramanual
Mounting on
an unstable
wall
- Manufacturer's statement
- Parts identification
- Accessories
- CHeKT account
- CHeKT account
If you do not have a CHeKT account, request a dealer account by visiting the
“CHeKT dealer” , before Step 3. Refer to the “CHeKT support” for more details.
CHeKT support
https://support.chekt.com
CHeKT dealer
www.chekt.com/registration
CHeKT support
https://support.chekt.com
1-4. Secure the main body
1 2
1-3. Connect cables to device.
DC power cable
12 V DC power for camera and PIR
8-pin I/O cable
Tamper
Alarm
Power
+- SP N/A COM AL TP TP
Pink
Orange
Yellow
Brown
Green
Purple
Black
Red
Do not connect to the N/A terminal.
Caution
Put the main body back on the mounting plate.
Waterproof cap
for LAN connection
Caution
Do not pinch the cables during assembly.
It can be also used as a back up
for POE
NOTE
Only the connector can be fixed
inside the body with double-sided
tape. The LAN connector must be
stored in the wall.
Refer to the Web manual how to use the cap.
2
2IP address settings
Step 3
Device registration to CHeKT portal
Step
The default network type of InSight is dynamic.
If you have a DHCP server, it will automatically set the InSight. Jump to Step 3
1-1. Disassemble
123
1Installation
Step
1-2. Install the mounting plate using 2 screws
Hook the fall prevent wire.
NOTE To pass cables through the wall, drill a 25 mm (1") or larger hole in the wall.
Use a single gang box for exposed wiring.
Caution
If you do not have a DHCP server, it will set as follows after one minute.
Initial address: Refer to the label on the InSight
User name: root
Default password: OPTEX
Change your password as appropriate.
Download IP installer;
https://navi.optex.net/firmware/50426
Refer to the “InSight IP camera install manual” for more details;
Setup your CHeKT Dealer Portal:
1. Go to http://dealer.chekt.com/ to log in.
2. Select the Customer on the left side of the dashboard.
3. Select the Site Devices tab.
4. Select the bridge device to be associated with the sensor camera.
5. Access the bridge settings using the gear icon to its right.
6. Select the appropriate tab to register the PIR camera.
Refer to the site for more details.
InSight Camera manual
https://navi.optex.net/manual/50426/en/?type=cameramanual CHeKT suppor
https://support.chekt.com
Detection area settings and walk test
4
Step
Changing for each item in this step is optional.
Check the default settings and if no changes are required, proceed to the next item.
Further information, refer to the “INS-QXI-ST Full manual” on the Web.
INS-QXI-ST Full manual
https://navi.optex.net/manual/50426/en/?type=installationinstructions
PoE LAN
cable
4-1. Horizontal adjustings
Horizontal: ±95°
1
2
Raise up
Pull back
Remove the Back cover. Adjust horizontal angle.
12
Only one side needs to be loosened.
NOTE
5
Checking
Step
Parallel
Adjust the detection range
3
Camera angle adjustment
2
Do not use the vertical angle adjustment of the main unit other than adjusting
the detection area surface to be parallel to the ground inclination.
Vertical: 0°to -20°
Caution
4-2. Vertical adjustings
PIR area adjustment
1
Loosen the screw to adjust camera angle
Angle can be adjusted with either left or right screw.
It is recommended that use the Camera angle at 25° to 35°
since camera images may appear white and blurred in dark scenes.
NOTE
Default
20°min.
35°max.
30°
1
2
4-3. PIR/VCA settings
4-4. PIR area masking
4-6. Put on the back cover
Refer to the InSight VCA manual for details on PIR and VCA area settings.
InSight VCA manual
https://navi.optex.net/manual/50426/en/?type=VCAmanual
INS-QXI-ST Full manual
https://navi.optex.net/manual/50426/en/?type=installationinstructions
4-5. Switch settings
ON OFF
Alarm output N.O. N.C. Do not change *
LED ON OFF
* Alarm output must be kept to N.C.
N.O. setting may cause unstable performance.
3 4
3 4
3 4
3 4
Low
Middle
PIR sensitivity
High
Super High
1 2 3 4 56 7 8
Default
Default
Future use
Do not move the mirror nor PCB from the factory settings as Pet alley cannot be set.
Caution
Walk test: Check the detection area by walking around the area.
System check: Check the image at the time of detection on the monitoring portal.
The default settings are 12.0 m (40') 120° wide.
If no masking of the detection area is required,
proceed to the next item.
If the vertical angle of the camera is to be adjusted, adjustment of this
sections must be matched to ensure the best performance of the sensor.
Caution
Unit: mm (inch)
OPTEX INC./AMERICAS HQ (U.S.)
www.optexamerica.com
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-europe.com
OPTEX SECURITY B.V.
(The Netherlands)
www.optex-europe.com/nl
OPTEX SECURITY SAS (France)
www.optex-europe.com/fr
OPTEX SECURITY Sp.z o.o. (Poland)
www.optex-europe.com/pl
OPTEX PINNACLE INDIA,
PVT., LTD. (India)
www.optexpinnacle.com
OPTEX KOREA CO.,LTD. (Korea)
www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
www.optex.co.th
Copyright (C) 2021-2022 OPTEX CO.,LTD.
OPTEX CO., LTD. (JAPAN)
www.optex.net
- Detection area
Others
- Specifications
- Dimensions
- How to reset to the factory default
FCC notification
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Personal Information
This product is equipped with the function to produce moving image of the designated area and
its surrounding, but not equipped with the function to store or register such image.
Prior to the installation of this product, the compliance to local laws and regulations needs to be
confirmed by the user of this product for the lawful installation and use of this product, and
signage and notification when using this product. User of this product is deemed to be
responsible for the compliance of any laws and regulations relating to personal information,
privacy protection and rights of portrait upon use of this product. Image taken by this product is
required to be treated appropriately under the responsibility of the user of this product.
Installation of this product, producing image, monitoring, recording with camera and handling of
personal information or data shall all be performed under discretion and responsibility of user of
this product, and OPTEX shall not be held liable for any dispute between a user and a third party.
- Compliance
12
3
Follow the steps below to perform a factory reset (for example, forget the password).
The IP address, ID, password and camera settings are initialized.
Caution
Do not pinch the cable when restoring the PIR detector.
About distribution of source code for open source software
This product includes open source software("OSS")
distributed under OSS License. In
compliance with the OSS Licenses such as GPL (GNU GENERAL PUBLIC LICENSE), LGPL
(GNU LESSERGENERAL PUBLIC LICENSE), and/or others included, we are making the source
code of the OSS available, at the actual cost, to our customer upon his/her request. The source
code corresponding to OSS included in this product will be provided in a prescribed manner for
at least than three(3) years after the date of purchase. Please note that the OSS is provided
without warranty of any kind.
• These units are designed to detect an intruder and activate an alarm control panel.
Being only a part of a complete system, we cannot accept responsibility for any
damages or other consequences resulting from an intrusion.
• Specifications and designs are subject to change without prior notice.
INS-QXI-ST
Passive infrared
12.0 m (40') 120° wide
40 zones
0.3 to 2.0 m/s (1' to 6'7"/s)
2.0℃( 3.6°F) at 0.6 m/s
PoE (IEEE 802.3af compliant)
Mini-jack 12 V DC 420 mA max.
Terminal 9.5 to 16 V DC/ 20 mA max. at 12 V DC
2.0 ± 0.5 s
Approx. 60 s (LED blinks)
N.C/N.O. switchable, 28 V DC 0.1 A max.
N.C. 28 V DC 0.1 A max.
Open when the cover is opened
[1] Warm-up [2] Alarm [3] Walk test end
1/2.8” CMOS
H: 114° V: 61°
Color: 0.02 lux. 0 lux. with IR
Visible up to 12 m
Day & Night Automatic/Manual switching
H.264, H.265, MJPEG
1080/ 30 fps, D1 (704 x 480 or 704 x 576)
IPv4: TCP/IP, UDP, RTP(UDP/TCP), RTSP, NTP, HTTP,
HTTPS, SSL, DHCP, SNMPv1/v2/v3(MIB-2), ONVIF
HTTPS(SSL), IP filtering, 802.1x, Digest authentication (ID/PW)
-30℃to +50℃(-22°F to +122°F)
95% max.
IP 54
Wall (Outdoor, Indoor)/Gang box
2.2 to 2.7 m (7'3" to 8'11")
0.85kg(30.0 oz)
[1] Mounting screw (4 x 20 mm) x 2
[2] T20 Torx wrench x 1
[3] Area masking strips x 1
[4] Waterproof cap for LAN connector x 1
Model
Detection method
PIR coverage
PIR zones
Detectable speed
Sensitivity
Power input
Alarm period
Warm-up period
Alarm output
Tamper output
LED indicator
Image sensor
Viewing angle
Minimum illumination
IR illumination
Night vision
Image compression
Resolution/ frame rate
Network protocol
Security
Operation temperature
Environment humidity
International protection
Mounting
Mounting height
Weight
Accessories
Top view
Side view
30 35
25
0
10
912 m
4
7.5 m
2
0
2
510 20
15
3
4
6
40 ft.
5
15
25 ft.
7.5 m
5
10
15
25 ft.
0
0
20
6
6 20
35
30
25
9
20
6
2.2 m
0
1510
5
0
312 m
40 ft.
2.7 m
b
c
d
e
e
fb
c
d
f
a
Caution Pet alley can not be set because the camera performance is not fully exhibited.
Do not slide the main unit of the detector.
Do not raise the mirror of the detector.
•
•
PIR
Camera
7’ 3”
8’ 11”
214 (8.43)
84 (3.31) 209 (8.23)
140 (5.51)
83.5 (3.29)
4
EU/UK contact information
https://navi.optex.net/cert/contact/
Cable
Factory reset switch
Press for 5 seconds to reset.

This manual suits for next models

1

Other Optex Security Camera manuals

Optex WATCHMAN User manual

Optex

Optex WATCHMAN User manual

Optex inSight INS-HX-80N User manual

Optex

Optex inSight INS-HX-80N User manual

Optex InSight Series User manual

Optex

Optex InSight Series User manual

Optex InSight INS-QXI-ST User manual

Optex

Optex InSight INS-QXI-ST User manual

Popular Security Camera manuals by other brands

D-Link DCS-4802E user manual

D-Link

D-Link DCS-4802E user manual

SecurityMan ClockCam-WiFi user manual

SecurityMan

SecurityMan ClockCam-WiFi user manual

Hanwha Techwin Wisenet PNP-9200RH quick guide

Hanwha Techwin

Hanwha Techwin Wisenet PNP-9200RH quick guide

Lorex LW2701AC1 Series quick start guide

Lorex

Lorex LW2701AC1 Series quick start guide

Vivotek IP7130 Quick installation guide

Vivotek

Vivotek IP7130 Quick installation guide

Lorex Professional CVC6993CL Specifications

Lorex

Lorex Professional CVC6993CL Specifications

Lorex CVC6975HR Quick setup guide

Lorex

Lorex CVC6975HR Quick setup guide

AVer SF2111H-BR user manual

AVer

AVer SF2111H-BR user manual

Burg Wächter SFC-851KDIA Quick installation guide

Burg Wächter

Burg Wächter SFC-851KDIA Quick installation guide

Panasonic WV-SC588A installation guide

Panasonic

Panasonic WV-SC588A installation guide

Digital Watchdog DWC-PTZ39XFM user manual

Digital Watchdog

Digital Watchdog DWC-PTZ39XFM user manual

Q-See QCN8009D Specifications

Q-See

Q-See QCN8009D Specifications

Mega Video MPV-720-M2 manual

Mega Video

Mega Video MPV-720-M2 manual

SpyCameraCCTV IDDVRCAM226 Product guide

SpyCameraCCTV

SpyCameraCCTV IDDVRCAM226 Product guide

Abus TVHD51000 user guide

Abus

Abus TVHD51000 user guide

EverFocus EBA1240 eZ.HD Series user manual

EverFocus

EverFocus EBA1240 eZ.HD Series user manual

Wansview NCZ-550W Operation guide

Wansview

Wansview NCZ-550W Operation guide

Siemens CCDA1435-DNX Quick installation guide

Siemens

Siemens CCDA1435-DNX Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.