manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ORIENTAL HUARAY GROUP LIMITED
  6. •
  7. Control Unit
  8. •
  9. ORIENTAL HUARAY GROUP LIMITED HR-1025 User manual

ORIENTAL HUARAY GROUP LIMITED HR-1025 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 1
HR-1025 Low Power RF Module
UserManual
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell phone: 86 15813856667 Fax: 86 755 81782518
Address: Huaxia Industrial park, Jingbei, Shiyan, BaoAn district, Shenzhen, China Postal code:
518108
Website: www.ohglrf.com E-mail:sales@ohglrf.com or [email protected]
Before using HR-1025 Module, please carefully read the user manual of HR-1025
Module, any question in technical, you can contact us. Tel: 86 755 81782516 Cell:
86 15813856667
Application field:
1. AMR system about the water, gas, electric and central heating
2. Industry remote control system and so on.
3. Data collecting system
4. Data transmission system in the railway station, oil field, dock, army field etc.
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 2
5. Medical treatment and electric meter remote control system.
6. Home and building automation system, street lamp wireless control system.
7. Orienting steel wheel system
8. Wireless intellectual over-weight detecting system
9. Queue management system in the bank, hospital, hall etc
Introduce:
Wireless transceiver module HR-1025 can be used in any standard or nonstandard
user protocol
The module has highly be avoided disturbance ability, long transmission range, the
distance can extend to 4500m (1200bps) in open field.
Low power consumption, transmitting current 450-550mA, Receiving current
32-38mA, sleeping current 3uA
The frequency is 433Mhz or 868Mhz
User can order the channel, we can supply 8 channels normally, as the user needs
we can design 16 or 32 channels too.
The module has TTL/RS232/RS485 interface, 7E1, 8N1, 7E2, 8E1, 8O1, 9N1
verify
We can supply the 1200bps/2400bps/4800bps/9600bps/19200bps baud rate, user
can choose one of the baud rate as you want
The user can also choose any antenna to match the modules
Ⅰ、Working qualification:
Ⅱ、Technical specification of HR-1025
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 3
Ⅲ、Interface definition:
HR-1025 (V1.1) module can supply a 9-pin connecter (CON1), and its definitions
as well as connection method for terminals are following show:
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 4
Ⅳ、Setting of the channel, interface, data rate and data format:
4.1. Before using HR-1025, you have to make simple configuration of your
system parameter such as interface and data format.
There is one group of 5-bit short-circuit wire(J1) on the bottom left corner of
HR-1025, defined as A, B, C, D, E respectively, assuming the open circuit wire (with
short circuit) is mode 0
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 5
Above figure is do not input the jumper, input jumper means make the two points join
together as the following show:
4.2 Channel configuration:
ABC jumper wires of J1 provide 8 options and you can choose 0-7 channels (ABC
jumper wire mode is the same), you can transmit data between each module, but keep
in mind at the same time only one modules is in TX mode.
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 6
4.3. Selection of interface mode:
HR-1025 (V1.1) provides there types of interface mode, COM1 (Pin3 and Pin4 of
CON1) is fixed as UART
Serial port of TTL level: COM2 (Pin6 and Pin7 of CON1) can choose interface
mode (RS-232, RS485) through D of J1
(1). TTLinterface connection application circuit
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 7
Note: Please do not connect any wire on Pin6 and Pin7 and also if the other wire
you do not use, please cut them down, or it will has interface.
If you use the TTL only please make sure the D jumper of JP2 without jumper wire
(D=0)
(2). RS-232 interface connection application circuit
Note: Do not connect other wires or it will has interface.
Module and computer DB9 connection figure:
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 8
Note: If the module and the equipment use different power supply, please make
sure the two use the same GND (join the two`s GND together).
(3). RS-485 interface connection application circuit
Note: Do not connect other wires or it will has interface
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 9
4.4: Interface rate setting
The rate of HR-1025 is determined by hardware to make sure the module rate is
suit to your system, we must tell your system`s rate.
4.5: HR-1025 can support no parity and even parity mode of the serial
communication
UART it can choose parity mode through E of J1
E=0 (without short circuit) parity 8E1 (even parity) 8O1/9N1/7E2
E=1 (with short circuit) parity 8N1 (no parity) 7E1
Note: channel setting COM2`s interface mode and parity mode is fixed after the
power is on if you want to change the setting, you must reset the module or power on
again.
Ⅴ、Indicator led function:
1. When power on the module, green led will flash one time, it means the module
is now is now output an edition information, from the edition users can know
HR-1025 (V111) C=00 (433), RS232/RS485, 8N1/9N1
Note: HR-1025 means the module brand, (V111) means the module`s edition
number.
“00” means channel number, RS485/RS232 is the interface choose 8N1/9N1 is the
verify mode.
2. When the data need to transmit to the air, Red led will flash one time (when
use RS232 or RS485 interface the light will not flash)
3. When the module receive the data from air, the Green led will flash again
Ⅵ、Time diagram:
HR-1025 has sleeping mode, it is controlled by SLP pin, usually the SLP is in the
high level mode (SLP=1), if you need the modules in the working mode, you need
make the RST pin become high level, User can reset or repower on the module, the
timing map as following show:
ORIENTAL HUARAY GROUP LIMITED
Tel: 86 755 81782516 Cell: 86 15813856667 Fax: 86 755 81782518 Website: www.ohglrf.com 10
Transmit timing delay
When the RXD of the HR-1025 (named A) receive data, then the modules send the
data to modules B(HR-1023), then the TXD output the data, between those transmit it
has a timing delay (Td), different baud rate has different delay time, example: when
you choose 1200bps, you need add 122ms delay in your program.
Ⅶ、Assembly drawing of structural size: