OrienTek TFM-200 Technical manual

TFM-200 Handheld Fiber Microscope Operation instruction
Product description

Eyepiece viewing

Ocus knob

Universal adapter

Two lighting modes

Battery cover
The hand-held fiber optic microscope is a fiber end face
detector. With its high-end optics, it can quickly manually focus
and detect scratches, dirt, and dust on the fiber end face. The
product supports UPC's SC, FC, ST, LC male heads, with good
optical performance and integrated laser safety filter, whether it
is tested on the production line or on-site, allowing your
technicians to quickly find scratches, fiber end dirt.
TFM-200
FiberConnector Microscope
X
200
1
5
2
3
4
Eyepiece: Optical fiber end face viewing window
1
Battery cover: unscrew to put the battery
2
Switch: Two different lighting modes can be selected
3
Adapter interface: including 1.25 mm and 2.5 mm
universal adapters
4
Focus knob: adjust the focus of the knob to check the
clarity of the fiber end face
5
TFM-200
200X
Fiber Connector Microscope
Toggle "|" to jump to the axial
illumination, toggle "||" to jump
to the side illumination, and
toggle "o" to directly turn off.
TFM-200
200X
Fiber Connector Microscope
The first step is to unscrew the
battery cover, and the second
step is to put the battery in, and
the battery can be replaced and
used in time.
TFM-200
200X
Fiber Connector Microscope
Holding the fiber optic
microscope with one hand,
aiming at the eyepiece with a
single eye, you can accurately
check whether the fiber end
face needs to be cleaned.
TFM-200
200X
Fiber Connector Microscope
Align the eyepiece and
adjust the focal length of the
knob to clearly check the degree
of dirt on the end face.
TFM-200
200X
Fiber Connector Microscope
Universal adapter
interface, respectively 1.25mm
and 2.5mm is appropriate
interfaces Orchestration.
Contact us
NANJING ORIENTEK OPTICAL COMMUNICATION LTD
Mail: [email protected]
Add: Jianshan Industry Park, Liuhe District, Nanjing, Jiangsu, China
Web: www.orientekot.com
TEL: +86 17312230635
Product features

Tips


Product parameter

Product parameter
200 times magnification, the fiber end face
is clearly visible.
The frosted silicone shell is non-slip, drop-proof
and shock-proof.
Support SC, FC, ST, and LC male headers of UPC.
Imported coated lens, fouling is clearly visible.
3*LR44 button battery 6F22 (need to buy by yourself).
Manually adjust the focus quickly.
Small size, can be held with one hand, convenient
and fast.
100,000 hours of LED lighting, 20 hours of standby.
Side lighting
Axial lighting
The lateral
Axial
Support SC/FC/ST/LC
Magnification 200X
Light source and
usage time
Size 225mm x 60mm x 42mm
White LED, service life of 100,000 hours;
Battery life of 40 hours
Adapter interface Includes 1.25 mm and 2.5 mm universal adapters
Interface Type SC, FC, ST , LC
Overview
Host
1.25 mm and 2.5 mm adapter nylon black bag;
LR44 button battery 6F22
(need to purchase by yourself);
Packing box.
Operating environment altitude:
areas below 2000m above sea level
Use environment
1) Do not store this product in high temperature, strong light
and strong magnetic fields, and do not place it in other harsh
environments such as fire sources.
2)Improper use of the product may easily cause the product
damage or may endanger personal and property safety.
3) If consumers violate the product manual and improperly
use it, the personal and property damage caused by it will
bearby yourselve, our company will not bear any legal
responsibility.
4) Non-professionals are strictly prohibited from
disassembling this product.
5) Avoid using electrical appliances or loads that exceed the
output current of this product (the circuit will be protected
and there will be no output).
6) Avoid strong physical effects, including knocking, throwing,
trampling, squeezing, etc.
Nylon carrying bag, product host, battery,
adapter interface.
Standard configuration
Please read all instructions and warnings before
using this product. Irregular use will cause
damage to the product or personal safety.
TFM-200
SC FC ST LC

Popular Microscope manuals by other brands

Huvitz HS-5500 Operator's manual

Huvitz

Huvitz HS-5500 Operator's manual

Saxon NK103-B instruction manual

Saxon

Saxon NK103-B instruction manual

Bresser Science TFM 201 instruction manual

Bresser

Bresser Science TFM 201 instruction manual

Accu-Scope Excelis HD quick start guide

Accu-Scope

Accu-Scope Excelis HD quick start guide

Motic AE2000MET instruction manual

Motic

Motic AE2000MET instruction manual

Bresser lcd micro 5mp operating instructions

Bresser

Bresser lcd micro 5mp operating instructions

Vision Engineering Ergo 80 user guide

Vision Engineering

Vision Engineering Ergo 80 user guide

Olympus BX41 instructions

Olympus

Olympus BX41 instructions

Nikon SMZ1500 instructions

Nikon

Nikon SMZ1500 instructions

Euromex BioBlue Series instruction manual

Euromex

Euromex BioBlue Series instruction manual

Olympus BX-FLA instructions

Olympus

Olympus BX-FLA instructions

Andonstar AD205 user manual

Andonstar

Andonstar AD205 user manual

Zeiss LSM 510 META operating manual

Zeiss

Zeiss LSM 510 META operating manual

MRC L3201LED user guide

MRC

MRC L3201LED user guide

Nikon LABOPHOT-POL instructions

Nikon

Nikon LABOPHOT-POL instructions

BioTools BS-2090 instruction manual

BioTools

BioTools BS-2090 instruction manual

4Deep HoloSea S7 user guide

4Deep

4Deep HoloSea S7 user guide

Fisher Scientific 11350119 instruction manual

Fisher Scientific

Fisher Scientific 11350119 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.