IG-284-EN version 03; 06/05/2020 3
General Instructions
cgm.800: Medium-voltage switchgear with integrated insulation in SF6gas
up to 36 kV in accordance with IEC Standard with rated current up to 800 A
Contents
Contents
1. General description ...................................................4
1.1. Models ......................................4
1.2. Standards applied............................4
1.3. Main components ...........................5
1.3.1. Gas tank .....................................6
1.3.2. Driving mechanism compartment ............6
1.3.3. Base .........................................7
1.3.4. Name plate ..................................8
1.4. Characteristics table .........................9
1.5. Dimensions and weights ....................10
1.6. Operating conditions .......................11
2. Handling and transport...........................................12
2.1. Lifting means ...............................12
3. Storage......................................................................14
4. Installation ...............................................................15
4.1. Unpacking the equipment ..................15
4.2. Location of accessories during transport .....15
4.3. Minimum installation distances..............16
4.4. Recommended cable connection trenches...17
4.4.1. Cubicles with internal arc in tank up to
20 kA - 0.5 s .................................17
4.4.2. Cubicles with classification of internal arc
IAC up to 25 kA - 1 s .........................20
4.5. Fastening to the floor .......................24
4.5.1. Fastening to the floor on profile .............24
4.5.2. Fastening to the floor by anchoring..........25
4.6. Connecting the cubicles.....................28
4.7. Earthing the switchgear .....................28
4.8. Cable connections ..........................29
4.8.1. Horizontal front connection ................30
4.8.2. Cable connection in fuse protection
function 1400 mm high .....................32
5. Recommended sequence of operations.................34
5.1. Checking the gas pressure ..................34
5.2. Live voltage indicator .......................35
5.3. Phase concordance check ...................36
5.4. Feeder function .............................37
5.4.1. Mimic diagram..............................37
5.4.2. Actuating levers ............................37
5.4.3. Opening operation from earthing position...38
5.4.4. Switch closing operation from open
position ....................................39
5.4.5. Opening operation from closed position.....40
5.4.6. Earthing operation from the open position ..41
5.4.7. Cable test...................................42
5.5. Fuse protection function ....................43
5.5.1. Mimic diagram..............................43
5.5.2. Actuating lever .............................43
5.5.3. Opening operation from earthing position ..44
5.5.4. Spring charge operation and closing of the
switch-disconnector from isolating position .45
5.5.5. Opening operation from switch-disconnector
closed position .............................46
5.5.6. Earthing operation from open position ......47
5.6. Fuse replacement sequence .................48
5.6.1. Selection of recommended fuses ............52
5.7. Circuit-breaker function with AV/RAV
driving mechanism .........................53
5.7.1. Mimic diagram..............................53
5.7.2. Spring charge and actuating levers ..........54
5.7.3. Opening operation from earthing position...54
5.7.4. Closing operation from isolating position ...56
5.7.5. Opening operation from closed position.....58
5.7.6. Earthing operation from open position ......60
6. Safety elements........................................................62
6.1. Acoustic earthing prevention alarm .........62
6.2. Interlocks ...................................62
6.2.1. Locking with a padlock......................63
6.2.2. Locking with a lock..........................63
7. Maintenance.............................................................64
7.1. Live voltage indicator test ...................64
7.2. Acoustic earthing prevention alarm test .....65
7.3. Specific maintenance for the cgm.800-v
cubicle .....................................66
8. Spares and accessories ............................................67
9. Environmental information ....................................69