Ortech DHOS User manual

INSTALLATIONINSTRUCTIONS
DHOS
Dual Technology
Humidity/PIR Motion Sensor
♦
SPECIFICATIONS
Minimun light load 10W or two light bulbs
Fluorescent..
♦
DESCRIPTION
15s, 5 mins, 15 mins, 30 mins
45%-80% RH
- 20FC
600sq.ft
The OHOS is a 3Amp, single pole Humidity/PIR occupancy sensing
switch.The OHOS help conserve energy and automate the lights in
your home. With it's humidity sensor and fan control automatically
detect excess humidity in a room such as bathrooms and basement
and responds by turning on the ventilation fan.The sensor continues to
monitor the air and automatically turns the fan off when the humidity
level has dropped below its preset level .Combines both technologies
can help reduce energy usage by operation the light or the fan only
when needed.
♦
COVERAGE
The coverage range of OHOS is illustrated and specified in Figure 1.
The diagram shows the motion detection area with small motion detection
closer to the sensor. Barriers within the space which blocks the line-of-sight
to the sensor detector will decrease the coverage area.
Best: 150 sq.ft.
Regular: 400 sq.ft.
Maximum: 600 sq.ft.
Figure 1
12'
6'
6'
12'
- 01-
SIDE VIEW
12'
180'' Field of View
♦
INSTALLATIONANDWIRING
WARNING
Turn OFF the circuit breaker, or fuse(s) and test that power is OFF before
wiring. Wiring the fan switch live can cause serious risk of electrical shock
and/or damage the switch, voiding the warranty. FOR SAFETY, THIS
PRODUCT MUST BE INSTALLED IN A GROUNDED ELECTRICAL
BOX. If you are unfamiliar with the methods of installing
electrical wiring, contact a qualified licensed electrician. ONLY
USE COPPER WIRE, DO NOT use aluminum wire with this device.
1. Make sure that the power has been turned OFF at the circuit breaker.
2. Connect lead wires as shown in the WIRING DIAGRAM ( Figure 2):
Connect Black and Blue lead together to Hot/Line wire, Red lead to
(Light) Load wire, Brown lead to (Fan) Load wire, White lead to Neutral
and Green lead to Ground.
Wiring Diagram:
Single Pole
Blue c~
Line2
Black
--
Line
Black
ITriei
White
Neutral
0
"
'----'
HUMIDITY
PIH
"
,, KO:
~
NlOOO
0 USE<>LY
Red
Brown
Green
Ground
Light
Primary
Load
Fan
Secondary;_____.
Load
;;
Figure 2
3. Check connections to ensure that they are tight and that are no bare
conductors are exposed.
4. Insert the OHOS into the wall box carefully.
5. Mount the device into the wall box with screws provided.
6. Attach the wall plate.
7. Restore power at circuit breaker.
8. Press and release the button to turn on/off the load.
How to remove the interchangeable color cover.
The switch comes with the top cover attached. It is very convenient to
change the top cover. Please proceed as follows:
1.7'
8$
cf g .
I 7
)t;::-'
/;
2.
Figure 3
...___
Push down the top cover to release Line up tabs and push up to attach
-02-
♦
PUSHBUTTONFUNCTIONCHART
The switch has four adjustable functions. Each function is shown below
*Factory default setting is indicated with (*)
Note: when the PIR sensor is detecting movement the light green
LED indicator will start flashing. The fan's LED will turns red when
the sensor detect excess humidity in a room otherwise it will always
stay lit in white.
Function 1: Time delay for the light and the fan
1. 15 seconds(')
2. 5 minutes
3. 15 minutes
4. 30 minutes
Function 2: Three adjustable modes
1. Automatic Humidity : Light (manual on, auto off), fan (automatically on
depends on humidity level) (*).
2. Automatic On/Automatic Off with PIR: When motion is detected, both
the light and the fan turn on automatically and turn off based on occupancy
for the selected time delay and humidity level.
3. Manual On/Automatic Off: Both the light and the fan turn on manually
and turn off automatically based on occupancy for selected time dela:
and humidity level.
Function 3: Ambient light level
(to keep the light off if the ambient light is sufficient)
1. Disabled
2. 5 Foot-candle r)
3. 10 Foot-candle
4. 20 Foot-candle
Function 4: Humidity level (Humidity Range 80% - 45%).
1. High Humidity
2. Medium Humidity (*)
3. Low Humidity
Factory Default and Quick Installation Setting
Setting T O I Operation
: ,me eay Mode Photocell . . Fan
Humcdcty'LED Indicator
15 Automatic: 5FC Flashing
*Factory Default Seconds Humidity Medium
Quick Installation 30 Automatic Disable ' Medium Solid
Minutes Humidity
To switch between factory default and quick installation setting simply
press and hold the light and the fan buttons for 1O seconds, released
when the light LED indicator turns solid green.
♦
FUNCTIONSETTING
To change a program feature:
PREP: review the switch adjustable four functions and its individual settin
before proceed with the programming. (During the programming, only the
light button will be used and the green LED light will flash)
-03-

1. START: programming mode
Press and hold the light button for five seconds, (its LED will stay on).
Now the sensor is in the Programming Mode.
a. The LED light will stay on for 20 seconds, waiting for the next step.
b. If the button has not been pressed within 20 seconds, the LED
light flash three times and the sensor will exit the programming
mode.
2. CHOOSE: functions from one through four
Press the button "X" number of times to enter a function to change, (the
LED light will flash with each press).
Note: When the button stops, the sensor will then flash back the current
setting for that function, (the sensor will do this ten times at two-seconds
interval, and then go back it last status mode).
3. CHANGE: the operation mode under each function
Press the button "X" number of times for the new setting, (the LED light
will flash every time it is pressed).
Note: When the button stops, the sensor will then flash back to the
setting for that function, (the sensor will do this ten times at two-seconds
interval, and then go back to it last status mode).
4. SAVE: setting
Press and hold the light button for five seconds until its LED light flash
three times then the program is saved.
Note: for demonstration purposes, the switch is set at quick installation
setting for the following examples.
Example 1: to change the current time delay for the
light and the fan operation mode of the switch from 30
minutes to 5 minutes as follow.
1. Press and hold the light button for five seconds, (the green LED light
should be solid).
2. Press the light button one time for function 1: time delay for the light
and the fan.
3. The green LED light now flash four times indicating the current time
delay which is at 30 minutes.
4. Press the light button two times to choose the operation mode of 5
minutes time delay.
5. The green LED light now flash two times confirming the new setting.
6. Press and hold the light button for five seconds until its LED light flash
three times then the time delay setting is saved.
Example 2: to change the current operation mode of
the light and the fan from automatic humidity to
automatic on/automatic off with PIR of the switch as
follow.
1. Press and hold the light button for five seconds, (the green LED light
should be solid).
2. Press the light button two times for function 2: operation mode for the
light and the fan.
3. The green LED light now flash one time indicating the current
operation mode which is automatic humidity.
4. Press the light button two times to choose automatic on /automatic off
with PIR.
5. The green LED light now flash two times confirming the new setting.
6. Press and hold the light button for five seconds until its LED light flash
three times then the new operation mode setting is saved.
- 04-
♦
OPERATION
♦
TROUBLESHOOTING
The OHOS features three user-friendly adjustable modes for customized The switch buttons are not functional
control to suit the specific ventilation/light needs of the room.These modes Check if the device is installed and wired properly. The device requires
are follow; Automatic humidity, Automatic ON/OFF PIR , and Manual a neural wire for operation.
On/Automatic Off. Beside these three modes, the time control can be
adjusted to set the minimum on time of the lights and fan for 15 seconds.
5 minutes, 15 minutes, and 30 minutes. In order to save energy this
switch will automatically turns the lights off when its preset on time is
expired. However the fan will continue to operate if sensor detect excess
humidity and automatically turns the fan off when the humidity level has
dropped. The sensor switch is also equipped with adjustable ambient
light level and humidity level. The humidity sensitivity adjustment can
be adjusted from high, medium or low.
Automatic Humidity: Light (Manual On/Automatic Off),
Fan (Automatic On/Automatic Off)
The device is pre-set at the factory and required to turn on the light
manually and turn on the fan automatically when the excess humidity is
detected. The sensor keeps the light on when there is occupancy and
automatically turn off if no movement is detected and the time delay setting
has expired. While the fan will turn off after the humidity level dropped
under the humidityset level. If the humiditylevelof an enclosedspace is still
over the preset humidity level after 30 minutes running, the fan will
continue to run after 20 minutes break.
Automatic On/Automatic Off with PIR:
The light and fan will turn on automatically with PIR motion detection
and turn off automatically based on occupancy and humidity level
respectively. During the light/fan on state, the light will turn off
automatically if no movement is detected and the time delay setting has
expired. However the fan will continue to operate if sensor detect
excess humidity and automatically turns the fan off after 3 minutes when
the humidity level has dropped.
Manual On/Automatic Off:
The light and the fan will turns on manually and turn off automatically
based on occupancy and humidity level respectively. During the light/
fan on state, the light will turn off automatically if no movement is
detected and the time delay setting has expired. However the fan will
continue to operate if sensor detect excess humidity and automatically
turns the fan off after 3 minutes when the humidity level has dropped.
Manual On/Manual Off:
At any time the light and the fan can be manually controlled with the
push buttons on the switch.
- 05-
Press the light or fan button
If the load does not work and the indicator light does
not flash
Turn OFF power to the circuit then check wire connections. Confirm
the neutral wire is connected, Black and Blue lead connect to Hot/Line
wire.
If the load operates normally, but the load will not
turn off.
Change sensor's mode of operation to desired setting and set to higher
humidity level.
Note: Do not use the switch to control a fan/light
combination where this is the only means of
illumination or light installed. The device will not
eliminate condensation solely and must be used with
a properly sized ventilation fan in an enclosed space.
♦
WarrantyInformation
Our company warranties this product to be free of defects in materials
and workmanship for a period of two years.There are no obligations or
liabilities on the part of our company for consequential damages arising
out of, or in connection with, the use or performance of this product or
other indirect damages with respect to loss of property, revenue or profit,
or cost of removal, installation or reinstallation.
- 06-
June,2016
00030A
Other Ortech Security Sensor manuals
Popular Security Sensor manuals by other brands

V-TAC
V-TAC VT-80301 instruction manual

Comelit
Comelit 47SE192KM user manual

Afriso EURO-INDEX
Afriso EURO-INDEX OWWG 3 operating instructions

Acroprint
Acroprint timeQplus TQ600 user manual

Crowcon
Crowcon Xgard IR Installation, operating and maintenance instructions

Visonic
Visonic DISCOVERY K9-80 installation instructions

SICK
SICK deTem4 Core Ex operating instructions

Edwards
Edwards SIGA2-HRS Installation and operation

SENSOR MAESTROS
SENSOR MAESTROS SFM2 user manual

Bosch Security
Bosch Security PC1A installation guide

BAPI
BAPI BA/LDT Termination and Troubleshooting

System Sensor
System Sensor 1112/24D Installation and maintenance instructions