manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Osram
  6. •
  7. Security Sensor
  8. •
  9. Osram HIGH BAY User manual

Osram HIGH BAY User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

OSRAM GmbH
Kunden Service Center
Customer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg
Germany
Tel : +49 (0) 1803 677 - 200
(kostenpichtig / charges apply)
Fax.: +49 (0) 1803 677 - 202
www.osram.com
www.osram.de
40083214100788
4008321410078 Page 1 of 4
Motion detector
Fitting instructions
VI 2009
HIGH-BAY_ma0906en_we1.01.indd
HIGH BAY
DE
BA
C
Description Purpose and application
The HIGH BAY motion detector detects the movements of
people and vehicles, such as fork lifts.
The sensor is attached to ceilings and is ideal for mounting at
great heights and for wide detection areas. The unit is mounted
directly in a dry lining box or using the „Mounting Adapter“,
optionally available from OSRAM, to ensure that the installation
conforms to the CE guidelines.
The HIGH BAY motion detector can be connected to any control
component with a oating input that is designed for permanent
contact (switch).
Function
The motion detector detects motion within a detection area of
360° and switches on the connected luminaires when motion is
registered. When motion is no longer registered, the luminaires
switch off after an adjustable delay period.
Design
The sensor is made up of the following components:
• Housing (A)
• Connection cable (B):
– L: phase (black)
– N: neutral conductor (blue)
– Floating switch contact (2x white)
• Motion sensor (C)
• Button for setting the delay (D)
• LED (E)
Installation Safety instructions
The motion detector must only be installed and put into opera-
tion by a qualied electrician. The applicable safety regulations
and accident prevention regulations must be observed.
WARNING!
Exposed, live cables or damaged housing.
Danger of electric shock!
• Only work on the motion detector when it is
de-energised.
CAUTION!
Destruction of the motion detector and other
devices through incorrect
mounting!
• Adhere to the connection diagram.
• Do not exceed the maximum line length.
• Do not route sensor lines together with power
supply or lamp lines.
Page 2 of 4
Installation (cont.)
F
G
H
max. 13 m
max. 10 m
0 m
3 m
6 m
9 m
10 m
12 m
13 m
9 m 6 m 3 m 0 3 m 6 m 9 m
max. Ø 12 m
max. Ø 18 m
Selecting the installation location
F Maximum mounting height
– Detection of movement of persons: 10 m
(àdetection area Ø 12 m)
– Detection of movement of vehicles: 13 m
(àdetection area Ø 18 m)
G Place devices that radiate heat outside of the monitoring
cone.
H Avoid drafts (e.g. from ventilators)
Attaching the motion detector to the
ceiling
Note: The mounting adapter, available as an accessory, can be
used for attachment. Follow the separate tting instructions.
 Unlock and remove the plastic cover by turning it anticlock-
wise.
 Screw on the motion detector, using the mounting adapter
as an aid, if necessary.
 Connect the sensor; see the connection diagram.
 Adjust the delay, if necessary; see the separate operating
instructions.
 Replace the plastic cover and lock it by turning it clockwise.
Page 3 of 4
Installation (cont.) I
K
L
N
PE
N L L N PE
16A
L
N
PE
N L
T1…8
GND
L
O
M
N
M
P
Q
R
L
N
PE
N L L N PE
16A
L
N
PE
N L
T1…8
GND
L
O
M
N
M
P
Q
R
Limiting the detection area
The supplied lens adhesives can be used to limit the detection
area, e.g.:
I End of passageway/corridor
K Middle of passageway/corridor
Connection diagram
L Variant 1: switching of mains voltage
M Switch contact
N Load (ECG, lamps, etc.)
O Variant 2: oating switching (example with EASY PB Cou-
pler)
M Switch contact
P EASY PB Coupler
Q EASY control line
R EASY control unit
Page 4 of 4
Appendix Technical data
Operating voltage 120 V … 277 V AC / 50-60 Hz
Fuse External 16 A
Switch output Floating switch contact
Switch output load
capacity Max. 5 A – 230 V
Inductive load: 250 VA
Ohmic lamp: 1200 W
Max. number of ECGs:
QTP5: 10 pcs. 1x14-35
8 pcs. 1x54 / 2x14-35
6 pcs. 2x80 / 2x54
QTP8: 10 pcs. 1x58
6 pcs. 2x58
QT-FIT8: 10 pcs. 1x58 / 1x36
6 pcs. 2x58 / 2x36
QTi: 15 pcs. 1x28/54
10 pcs. 2x28/54
6 pcs. 2x35/49/80
Operating temperature -10 °C … +70 °C
Protection type IP 20
Dimensions
(Ø x H) 115.6 x 39.4 mm
Dimensioned drawing
Ø 115,6 mm 39,4 mm
The EMC requirements to EN 55015 are fullled.
Conformity with the relevant EU directives is
conrmed by the CE symbol.