Oval Flowpet-5G Series User guide

88888888
I.Fr
O.t
F.t
SoFt.
FC.r
SWR
SWM
LooP
S.b
S.c
nA
AL
A1
A1
A1
A2
A2
A2
rAtE
AF
Ad A
A
bP
At
Po n
Un
SP
d.o1
d.o2
⇒HoldingtheMODEbuttondown
until the last bar disappears
executes long-press process
(Switching between Normal
mode and Review mode, or
finalizingtheparametersetting,
etc.).IfturnedOFF(releasing
the MODE button) before the
lastbar disappears, the same
operationas①Normaloperation
willtakeplace.
OPERATINGCONDITIONS
PRECAUTIONSONINSTALLATIONLOCATION
②Analogoutput+Pulseoutputtype
←max.20mA
DC
←max.20mA
max.
max.30V
30V
←max.20mA
DC
←max.20mA max.
max.30V
30V
Outputtype Specification
Factoredpulse
Unfactoredpulse
Analog
Model
mm
※3
L/h
L/P Hz mL/P Hz
LS5277
20
1
0.33
9.918
33.6
1200
LS5377
25
1
17.955
55.7
3600
LS5577
40
10
0.2
0
35.496
56.3
7200
LS5677
50
10
0.33
76.455
43.6
12000
LS4976
20
1
0.22
5.928
37.5
800
LS5076
20
1
0.56
9.912
56.0
2000
LS5276
25
1
1.05
9.639
3800
LS5376
40
1
1.77
17.47
101.8
6400
LS5576
40
10
0.38
34.526
112 .6
14000
LS5676
50
10
0.66
74.483
89.5
24000
Item Specification
Localdisplay
function
Displaymode Displaymodesymbol
SelectablewithMODEbutton
ZeroresettablewithRESETbutton
①Accumulatedtotal(8-digit) None
②
Instantaneousflowrate,L/h(5-digit)
b1
③
Instantaneousflowrate,L/m(5-digit)
b2
④Resettabletotal(7-digit) C
Displayaccuracy Totalflow Within±1count
Instantaneousflowrate Within±1%offullscale
Displayorientation
Flowdetection
Magneticsensordetectsalternatingmagneticfields.(200Hzmax.)
Cable
Transmission
distance
EitherPulseorAnalog
outputused
Max.1km
(CVVS:1.25to2.0mm2)
Pulse+Analogoutput
bothused
Max.100m
(CVVS:1.25to2.0mm2)
Powersource
Lithium
battery
External
powersource
12to50VDC±10%(consumptioncurrent:Max.30mA)
(Foranalogoutput,referto"6.Acceptableloadresistancerange")
Ambienttemperature
-10to+60℃(nocondensing)
Material Polycarbonate(black)
Configuration IP65(Installindoorsorundertheeaves.Avoidexposuretodirectsunlight.)
Leftback:MODEbutton
Rightback:RESETbutton
PUSH!
※
1:AboutthedisplayduringMODEbuttonoperation
①Normaloperation ②Long-pressoperation
Accumulatedtotal
Instantflowrate:L/h
Instantflowrate:L/m
Resettabletotal
MODE
MODE
MODE
MODE
RESET
Item Description
Pon Factoredpulsewidth[ms]setting
Pu Factoredpulseweight[L/P]setting
AF Analogoutputfullscale[L/h]setting
(Flowindicatordisplayislinkedtothissetting.)
AdAn Analogoutputdamping[sec.]setting
LooPtESt Simulatedoutputatarbitraryflowrate
⇒Refertothecorrespondingsectionsintheinstruction
manualfortheproceduressuchaschangingeach
parameterandoperatingthesimulatedoutputfunction
.
[NOTE]
Pleasereadbeforeinstallationanduse
Tomaintainhighaccuracyandlonglifeofthismeter,itisnecessarythatthemeter
be used within the specified conditions in flow rate, pressure, temperature and
viscosity.Theseoperatingconditionsarestatedonthenameplateoftheregister.
Confirmthecontentsofthenameplatethoroughlybeforeinstallationandoperation.
(1)Inthisregister,amagneticsensorisusedtopickupmagneticfieldsofsignaling
magnets embedded in the rotor. For this reason, the FLOWPET should be
installedsufficientlyawayfromsourcesgeneratingmagneticfield.Ifamagnetic
valveof10wattsorsoisused,separateitatleast10centimetersfromthe
flowmeter(varieswithoperatingconditions).
(2) For applications in cold regions, install the meter indoors (boiler room, for
example)topreventaccidentscausedbyfreezing.
①Averticalrunisrecommendedforeaseofpipelinedrainage.Provideadrain
plug.
②Wheninstallinglagging,donotlagtheelectronicregister,strainercover,and
drainplug.Also,makesureofreadyseparationofthemeterfromthepiping
assembly.NOTE:Refertothecorrespondingsectionsintheinstruction
manualforpipingdetails.
(3)Thisregisteroperatesatthetemperaturerangeof-10to+60゜C.Toensureits
operation within the specified temperature range, protect the register with a
sunshadeorheatshieldifexposuretoelevatedtemperaturesbydirectsunlight,
reflectedheat,etc.,isexpected.
(4)Thisregisterisdesignedforindooruse:installthemeterinalocationfreefrom
rainwater, oil, or sunlight. If exposure to such environment is unavoidable,
provideappropriateweatherprotectionorsunshade.
Allspecificationsinthisstartupguidearesubjecttochangewithout
noticeforimprovementinperformanceandproductquality.
ElectronicRegisterSTARTUPGUIDE
ThankyouforchoosingtheFLOWPET-5G.
・This Startup Guide provides basic information that is
helpfulforstartingtheuseoftheFLOWPET-5Gelectronic
register. For detailed explanation of the FLOWPET-5G's
functionsandoperationinstructions,refertotheaccompa-
nyinginstructionmanualbeforeuse.
・PleasekeepthisStartupGuidehandyforquickreference.
1.GENERALSPECIFICATIONS
Displayangleadjustablein15°steps
(Adjusttheangleupordownbyhandtofind
easy-to-viewposition)
3.BASICOPERATIONPROCEDURE(MEASUREMODE)
Theflowindicatoratthebottomofthedisplayindicates%ofactualflow
(instantaneousflowrate)tothefullscaleflowrate.
NOTE:Fullscaleflowrate(flowratewhichrepresents100%)isdeterminedin
theparameter:AF.(AFvalueisalsoappliedtotheanalogoutputfullscalevalue
ofanalogoutputspecification)
Ontheresettabletotaldisplay,
zero-resetwillbeperformedon
totalflowbypressingtheRESET
button.
WhentheMODEbuttonis
pressed:
⇒8barsappear.
WhentheMODEbuttonis
keptpresseddown:
⇒Barsbegintodisappear
onebyonefromtheleft
⇒Immediately turning OFF
(letting go of the button)
scrolls the display to the
nextone.
2.OPERATIONBUTTONS
・Thepushbuttonsforoperation(MODEandRESET)arelocatedonthebackofthedisplay.
BROSUP.:Power+
BROSUP.:Power+
4.WIRING(formodelswithoutputcapability)
①Pulseoutputtype
GRYSIG.1:Factoredpulse(orAlarm1)※1
GRYSIG.1:Factoredpulse(orAlarm1)※1
WHISIG.2:Unfactoredpulse(orAlarm2)
※1
WHISIG.2:Unfactoredpulse(orAlarm2)
※1
12to50V
12to50V
GRNCOM:0V
GRNCOM:0V
NOTE:Leavetheshieldedwireopenatitsend(nocontact).Toextendthe
cable,makesuretouseshieldedwireandextendtheshieldaswell.
NOTE:Leavetheshieldedwireopenatitsend(nocontact).Toextendthe
cable,makesuretouseshieldedwireandextendtheshieldaswell.
4to20mAAnalogoutput
※1:SIG.1andSIG.2cangeneratepulsesbybuilt-inbatterypowerwithoutexternalpowersource.(Batterylifeis8yearsapproximately.)
Foranalogoutputonlymodel,leavetheendsofSIG.1andSIG.2cablesopensincetheywillnotbeused.Alarmoutputisoptional.
8.DISPLAYMENUTREE
5.OUTPUTSPECIFICATIONS
・Opendrainoutput(equivalentofopencollector)
・Allowablecurrent:20mA,Max.voltageapplied:30V
(Adjustableat[Pon]parameterwithintherangeof1to999msin1msincrements.)
・Opendrainoutput(equivalentofopencollector)
・Allowablecurrent:20mA,Max.voltageapplied:30V ・Pulsewidth:2ms(fixed)
・4to20mAoutput(usingpowerwire)・Acceptableloadresistance:seefigurebelow.
6.
ACCEPTABLELOADRESISTANCERANGE
7.STANDARDPULSEUNIT※2
1.00
109.5
※2:Unlessotherwisespecified,pulseunitissetaccordingtofactoredpulseunitlistedintheabovetable.Fortheofficial
specificationatthetimeofshipment,pleaseconfirmthenameplateontheactualproduct.
※3:Fullscalevaluesof"Flowindicatordisplay"and"Analogoutput"willbemax.flowratevaluesinthetableabove.
(Foroil-servicemodels,theactualratedmaximumflowratevariesbytypesofoil.)
Under"ReviewMode",settingchangestotheitemslisted
belowandusingspecialfunctionssuchas"Simulated
Output"areavailable.
1900
600
012 24 50
Powersupplyvoltage(VDC)
PRESSPRESS
toturnontoturnon
PRESS
toturnon
XXXXXXXX[□]
b1±XXXXX[□/h]
b2±XXXXX[□ /min]
CXXXXXXX[□]
totAL Alarmdata
A.tri.
tESt
Simulatedoutput
Servicemode
F
Instantflowrelateddata
dAlarm1setting
Simulated
instantflowvalue
Simulated
total
flowvalue
Inputfrequencydisplay
Hn
Fullscaleflowrate
H
Alarm1hysteresis
Operatingtime
Pu
Damping
Instantflowdecimalpoint
S
Alarm1status
Simulatedoutput
Flowoperatingtime
Pulsewidth Samplingtime d
Indicatedunit H
Alarm2hysteresis
Totalflowdecimalpoint
S
Alarm2status
None
C
:HoldingtheMODEswitchpressedformorethan2secondsatthis
displaychangestheReviewModetotheWriteMode.Thefollowing
operationsareenabledintheWriteMode:
①PressingtheMODEswitchmovesthedigitoneplacetotheleft.
②PressingtheRESETswitchincreasesthefigurebyone.
③HoldingtheMODEswitchpressedformorethan2secondsagain
changesthemodebacktotheReviewMode.
:T i t l e
(Titlesdescribetheattributesofeachparameterstoredundereach
title:Theyarenotsettableparameters.)
:SwitchingtoWriteModefromthesedisplayswillallowoperatorsto
usespecialfunctionssuchasanalogtrimsandsimulatedoutput.
NOTE:Goesbacktothescreenbefore
switchingtoReviewMode
:Transitionmadebypressing"MODE"switch
:Transitionmadebykeeping"MODE"switchpressedformorethan5seconds
:Transitionmadebypressing"RESET"switch
b1
b2
Accumulatedtotal
Instantflowrate(hourly)
Instantflowrate(per-minute)
Resettabletotal
Totalflowrelateddata
Meterfactor
Conversionfactor
Digitaloutput1assign.
Digitaloutput2assign.
Samplingcyclenumber
Alarm2setting
NOTE:Displayedonlyonanalog
outputequippedmodels.
Analogtrim
4mAtrim
20mAtrim
No.ofMODEswitchpress
No.ofRESETswitchpress
Factoryreset
Softwarerevision
NOTE:Notdisplayedonstandard
specification.(Displayedonlyon
alarmoptionspecifiedmodels)
※1:DuringReviewMode,theinformationicon is
displayedontheupperrightcornerofthescreen.
※2:Parametersymbolsaredisplayedatflowrateunitdisplay
area.
※3:Thisproductdoesnotused.o3modesetting.
Ins. No.S-179-SU-1-E
Operating
range
1mofvinyl-sheathed,4-conductorshieldedcable(individualelementsAWG24)
furnishedasstandard(Notfurnishedwithmodelswithoutpulsegenerator)
3.6VDCdedicatedbatterybuilt-in,Batterylife:8years(varies with operating conditions)
Storagelife:10years
・Batteryiconblinksasthebatterystartstorunout.
・Ifequippedwithpulseoutputcapability,pulsegenerationcanbedonejustwithbuilt-in
batterywithoutanexternalpowersource.(Ifsuppliedwithexternalpowersource,lithium
batterywillnotbeconsumed.)
EachtimetheMODEbuttonispressed,thescreenscrollsthrough
flowdisplays;selectthedesiredflowdisplay.
(Accumulatedtotal→Instantaneousflow:L/h→Instantaneousflow:
L/m→Resettabletotal)
Loadresistance:R
L
Allparametersaresetbeforeshipmentbasedonthe
specificationsatthetimeoforderreceipt,andgenerally
there is no need for the users to perform parameter
setting.Properflowmeasurementmaybeunavailableif
parameter setting is performed inappropriately. Please
avoidperformingunnecessarychangestotheparam-
eters.(Confirmthecorrespondingsectionsintheinstruc-
tionmanual thoroughly in caseit isnecessary tomake
parameterchanges.)
Factored
pulse
Unfactored
pulse
Max.
flowrate
Nom.
size
Pulse
unit
Output
freq.
Nominal
meter
factor
Output
freq.
LoadresistanceRL(Ω)
MeasureMode(normalmode)
ReviewMode
Pulseweight
OVAL Corporation
Phone. 81-3-3360-5121 Fax. 81-3-3365-8605
FLOWPET-5G
StArt
A20
A04
※3
※1
※2
※2
d.o3
Digitaloutput3assign.
EnergySavemodesetting
ES.bt.
Other manuals for Flowpet-5G Series
2