NEOxl 40 Spare Base Module Controller Instructions
10400902 ©2019 Overland-Tandberg Page 2 of 3
Power Off Library
If still running, power off the library from the Base Module
front panel by pressing and holding down the power button for
three (3) seconds.
NOTE: If the library does not perform a soft shutdown, press and
hold the power button for 10 seconds.
Verify that the Robotic Assembly is in its parked position and
that all host processes are idle.
Remove Cords and Cables
Disconnect all cables and cords, noting where they connect.
1. Unplug any AC power cords (1).
2. For a multi-module system, remove the expansion
interconnect cables (2) from the Base Module and any
Expansion Modules to which it is connected.
NOTE: Completely remove the expansion interconnect cables
from the modules to prevent damaging the cables during
module removal and replacement.
3. Label and remove any Ethernet management cables (3).
4. If present, remove the optional USB device (4).
Replace the Controller
1. At the rear of the Base Module, loosen the two blue
thumbscrews on the old controller.
2. Using the thumbscrews, slowly remove the controller
from the module and set it aside.
3. Position the new controller on the alignment rails.
4. Slide the controller slowly into the module until it is flush
with the rear panel of the module.
5. Finger-tighten the thumbscrews to secure it.
Reattach Cables and Cords
1. For a multi-module system, reconnect the expansion
interconnect cables (2) from the Base Module to any
adjacent Expansion Modules.
2. Reconnect any Ethernet management cables (3).
3. If removed earlier, reinsert the USB device (4).
4. Reconnect the AC power cords (1).
Power on the Library
Power on the library from the Base Module front panel by
pressing and holding down the power button for three (3)
seconds until the green light on the front panel illuminates
indicating the status is
Ready
.