Apogee Ascent Quick Start Guide
Unpacking your Camera and Accessories
2
Installing the Camera Acquisition Software
You must have administrator access on your PC to perform this installation.
• We recommend you install your camera acquisition software e.g. Windows SDK for Apogee, Micro-Manager or
MaxIm DL before setting up your Apogee camera.
• Please see the Windows SDK for Apogee, Micro-Manager or MaxIm DL installation guides for specic instructions
related to installation of this software.
• Apogee cameras are supported by MaxIm DL version 3.21 and beyond.
• Apogee Camera Control Demo software is for demo and test purposes only. Available for download from andor.com.
If you are using different camera control software, please refer to the software installation information supplied with the
software.
3
For more information visit: andor.com/software/software_support/
Please turn over
6V Ascent
Power Supply
Apogee
Integration Starter
Kit CD
Country Specic
Power Cord
USB 2.0 Cable
Apogee Ascent CCD
Camera
Refer to the user manual for further information.
Optional ItemsStandard Items
Optional items are supplied as specied
for your application at the time of
ordering:
Items include:
• Lens Adapters
• Telescope Adapter
• USB Extender
• Filter Wheel
• Temperature compensated focuser
Lens Adapter Filter Wheel
Camera
Preparing your Facility
Handle the camera and accessories with care.
Apogee Ascent weighs 0.65 kg [1 lb 4 oz].
Observe anti-static precautions when
installing the controller card and camera.
Ensure 100 mm clearance around camera
and power supply vents (Do not block
vents when operating on benchtop).
Operation of the camera close to intense
pulsed sources (e.g. plasma and X-ray
sources) may compromise performance.
Keep dry, <70% humidity non-condensing
Use correct power supply and cables.
Operate between 0°C and 40°C. Refer to User
guide for further information regarding ambient
temperature, cooling performance and dew point.
Store between -25°C and 50°C.
1
4Install the Camera Drivers
5
1. Insert the 6V DC power cable into the power connector on the
Connections panel of the camera.
2. Connect the supplied USB cable between the USB connector
on the camera and the corresponding slot on the PC
3. Optional: An 8-pin Mini DIN connection enables various
hardware signals to be controlled by the device. If this is
required, connect the I/O Connection cable to the I/O 8
mini DIN type connector. (refer to the user guide for further
information).
4. Turn power to the camera ON.
5. Turn ON the PC.
6. Start your software.
7. Start acquiring data.
Troubleshooting
Camera LEDS do not light
• The LEDs should ash on startup, if this does not occur, ensure that the power cables are connected and the
power is turned on.
Cannot nd camera when using ApogeeCameraInfo
• The ApogeeCameraInfo search process takes approximately 10 seconds to complete. In extremely rare
circumstances, the camera may take longer than 10 seconds to respond.
• If the rst attempt to nd the camera fails, try a second time. If the second attempt fails, the “Broadcast
Address” eld may be incorrect. Verify the correct broadcast address and try again.
Connecting your Camera and Switching it on
6
MAN-06734
MAN-09694
ASCNTSG 0816 R1
For additional troubleshooting information please refer to the user manual on the CD provided and for
technical information about the Apogee Ascent go to:
www.andor.com/scientic-cameras/apogee-camera-range/ascent-interline-series
Connections
?
The Ascent can be connected to a telescope, lens or other equipment using a wide range of plate-lens adapters
and other accessories. An outline is shown below. Refer to your user guide and contact your customer support
representative for further information if required.
WARNING:
• Do not connect your Apogee camera to a PC before installing the drivers. If you do and the “Add New Hardware Wizard”
appears, please select the Cancel button.
• Never connect or disconnect the camera from the PC during operation.
To Camera I/O port
USB to PC
Power
1. Ensure the camera control software (e.g. Maxim DL and
drivers have been installed.
2. Attach the camera mounting adapter to the camera face
plate using the supplied mounting screws. Note: if using a
lter wheel the lter wheel may be supplied pre-tted to the
camera.
3. Attach the camera and mounting assembly to the telescope
or lens.
4. Now connect the power and signal connections
Left: Ascent shown with
lter wheel and lens
adapter (Nikon) attached.
Above: Example of mounting options for the ascent.
WARNING:
• Do not connect your Apogee camera to a PC before installing the drivers. If you do and the “Add New Hardware
Wizard” appears, please select the Cancel button.
• Never connect or disconnect the camera from the PC during operation.
1. Make sure your Windows user account has administrator privileges.
2. Double click on the setupApogeeSoftware.
3. Follow the steps in the Installation Wizard.
4. Click Finish.
5. The drivers for your Apogee camera are now installed on your PC (A notication should be displayed in the bottom
right corner of your PC screen).
Mounting the Camera

Other Oxford Instruments Security Camera manuals

Oxford Instruments ANDOR Clara Installation instructions

Oxford Instruments

Oxford Instruments ANDOR Clara Installation instructions

Oxford Instruments ANDOR Zyla User manual

Oxford Instruments

Oxford Instruments ANDOR Zyla User manual

Oxford Instruments ANDOR iKon-XL Series Installation instructions

Oxford Instruments

Oxford Instruments ANDOR iKon-XL Series Installation instructions

Popular Security Camera manuals by other brands

Sony EVI-FDP8C3 Specifications

Sony

Sony EVI-FDP8C3 Specifications

SecurityMan FreeCam2 specification

SecurityMan

SecurityMan FreeCam2 specification

Interlogix TVP-6102 installation guide

Interlogix

Interlogix TVP-6102 installation guide

Riva RC3502HD-5311 installation guide

Riva

Riva RC3502HD-5311 installation guide

CLEBO-HD AID-2301 IR manual

CLEBO-HD

CLEBO-HD AID-2301 IR manual

American Dynamics VideoEdge IP Indoor Mini-dome 8200-2646-02... Installation & operation guide

American Dynamics

American Dynamics VideoEdge IP Indoor Mini-dome 8200-2646-02... Installation & operation guide

Wisenet TNO-6320E quick guide

Wisenet

Wisenet TNO-6320E quick guide

Intellinet IBC-667IR Hardware installation guide

Intellinet

Intellinet IBC-667IR Hardware installation guide

Velleman CAMTVI7N user manual

Velleman

Velleman CAMTVI7N user manual

Hitachi Kokusai Electric KP-F500PCL Operation manual

Hitachi Kokusai Electric

Hitachi Kokusai Electric KP-F500PCL Operation manual

Vitek VTC-IRE40 manual&nbsp;

Vitek

Vitek VTC-IRE40 manual&nbsp;

Vitek VTC-IR302FN user manual

Vitek

Vitek VTC-IR302FN user manual

Hanwha Vision PNO-A6081R user manual

Hanwha Vision

Hanwha Vision PNO-A6081R user manual

CLEBO-HD AOD-2301 manual

CLEBO-HD

CLEBO-HD AOD-2301 manual

TP-Link VIGI C440 quick start guide

TP-Link

TP-Link VIGI C440 quick start guide

Allied AVT STINGRAY Technical manual

Allied

Allied AVT STINGRAY Technical manual

Princeton ProEM-HS user guide

Princeton

Princeton ProEM-HS user guide

LG LCV5300R-BP owner's manual

LG

LG LCV5300R-BP owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.