SPECIFICATIONS
Input: 220-240V~50Hz
Pump Max: 1.1kW, 10 Amps
Max. Pressure: 10 bar (1 Mpa)
Inlet & Outlet: 25.4mm (1“BSP) Male
Water Temp.: 1ºC to 35ºC
Cable Male Plug: 1.5m
Cable Female Socket: 0.5m
IP Rating: IP65
Weight: 1.7kg
PSA-001
STANDARD EQUIPMENT
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from
the original date of purchase. If a product is defective it will
be replaced in accordance with the terms of this warranty.
Warranty excludes consumable parts, for example: O-rings, bearing,
seals gaskets.
WARNING
The following actions will result in the warranty being void.
•If the tool has been operated on a supply voltage other
than that specified on the tool.
•If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
•Failure to perform maintenance as set out within the
instruction manual.
•If the tool is disassembled or tampered with in any way.
•Professional, industrial or high frequency use.
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
The benefits provided under this warranty are in addition
to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded
at law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Generally you will be responsible for all costs associated with
a claim under this warranty, however, where you have suffered
any additional direct loss as a result of a defective product you
may be able to claim such expenses by contacting our customer
service helpline above.
ozito.com.au
0518
Pressure Switch
Teflon Tape

ONLINE MANUAL
Scan this QR Code with your
mobile device to take you to
the online manual.
1. Discharge outlet
2. LED’s
3. Restart button
4. Brass union (knuckle)
5. Inlet
6. Female socket
7. Male plug
PRESSURE SWITCH
KNOW YOUR PRODUCT
1. ASSEMBLY
SETUP & PREPARATION
WARNING!: ENSURE THE PRESSURE SWITCH
IS DISCONNECTED FROM THE POWER SUPPLY
BEFORE PERFORMING ANY OF THE FOLLOWING
OPERATIONS.
ACCESSORIES
8. Teontape
Connecting the Pressure Switch
1. Screw the pressure switch
brass union to the transfer
pump outlet of a suitable
pump.Tightenrmlywitha
spanner (not included).
Note:Teontapeisrequiredonthreadstoensureawatertight
seal and prevent any leakage.
Connecting to the Pumps Suction Inlet
1. Insert 1” male threaded
adaptor (not included).
Tightenrmlywitha
spanner (not included).
2. Securely attach the
input hose or pipe (not
included) to the other end
of the adaptor. Ensure
you have the correct
diameter hose or pipe that
is compatible with your
water drawing source and
pump.
1
8
4
5
6
7
3
2

Primingthepumpisrequiredtopurgeairfromthehose.Don’t
operate the pump without it being primed.
1. Ensure the pump is
switched off at the mains
power.
2. Remove the priming plug
from the top of the pump
housing by turning anti
clockwise.
3. Fill the pump completely
with water. Ensure the
pump and inlet pipe or
hose are full. Replace the priming plug.
4. To fully prime the pump refer to “Starting the pump”.
2. PRIMING THE PUMP
OPERATION
WARNING!: THIS PRODUCT IS INTENDED
FOR PUMPING WATER IN A HOME DOMESTIC
APPLICATION. DO NOT USE IT FOR CORROSIVE,
ABRASIVE, EXPLOSIVE OR DANGEROUS LIQUIDS.
CAUTION. THE PUMP SHOULD BE FILLED WITH
WATER AFTER EACH NEW CONNECTION OR IF WATER
LOSS OR AIR INTAKE HAS OCCURRED. EXTENDED
OPERATION WITHOUT A WATER REFILL WILL DAMAGE
THE PUMP!
Connecting to the Discharge Outlet
1. Insert a 1” female threaded
adaptor (not included).
tightenrmlywitha
spanner.
2. Securely attach the
output hose or pipe (not
included) to the other end
of the adaptor. Ensure
you have the correct
diameter hose or pipe
that is compatible with
your water discharge
application.
Note: The discharge hose or pipe you are using must have a
minimum diameter of 19mm (3/4’’).
Note: Ensure the discharge hose or pipe is not restricted in any
way and nothing is obstructing the hose or pipe when the pump
is in operation.
WARNING!: RISK OF INJURY! IF THE
COMPONENTS ARE NOT COMPRESSION-PROOF
OR IF THEY ARE IMPROPERLY INSTALLED, THE
PRESSURE LINE COULD BURST DURING OPERATION.
Connecting to the Female Socket
1. Connect the pump power
cord plug to the pressure
switch female socket

PSA-001
4. OPERATING THE PUMP3. STARTING
CAUTION. THE PUMP MUST NOT BE ALLOWED TO RUN
DRY.
SUFFICIENT WATER MUST BE ON HAND AT ALL
TIMES.
WARNING!: THIS PUMP MUST BE USED WITH
A RESIDUAL CURRENT DEVICE WITH RATED
RESIDUAL CURRENT OF 30mA OR LESS.
Note: Whenthepumpisfullyprimedandtheairhasbeenushed
out, the pump is ready to operate.
Starting the pump
Thepumpandsuctionlinemustbeconnectedandlledwith
water, refer “PRIMING THE PUMP”.
1. Connect the pressure
switch male plug to the
mains power and switch
on.
2. Switch your pump on if it
has a ON/OFF switch.
3. Fully open any shut-off mechanisms (spray nozzles,
valves, etc.) in the pressure line so that the air can escape
without obstruction.
Note:Whenthepumpisfullyprimedandairisushedout
of the suction cycle, the pump is ready to operate. The pump
may take several minutes to fully prime air from the suction
line and inside the pump.
4. Check to make sure that water is coming out.
Note: If the pressure line is closed, (such as shutting off a tap
down stream) the pump will build up pressure, then switch off
at the preset cut off when the pressure line is opened again,
the pump will automatically restart.
If the motor does not start up or the pump does not build up
any pressure or if similar faults occur, turn the device off and
refer to “TROUBLESHOOTING”sectiontondaremedy.
Pressure Switch
‘GREEN Power on’.
This indicates that there is power
to the pump, but the pump is
currently not on.
‘YELLOW + GREEN Pump on’.
This indicates that there is power
to the pump and the pump is
running.
‘RED Failure + GREEN’.
There is power to the pump, but
owisstalled.Inthisevent,press
the Restart button.
If the malfunction still occurs, refer
to the “TROUBLESHOOTING”
sectiontondaremedy.
‘RESTART Button’.
Whenthepumprequiresrestating
(Failure light illuminates red),
push the Restart button and
hold for 5 seconds to re-start
the pump, the red failure light
should turn off. If the failure light
re-illuminates red, refer to the
“TROUBLESHOOTING” section
tondaremedy.
Note: If all three lights are on; the Pump has detected a
failure, but will continue to run for approx. 10 seconds to
attempttoxtheproblem.

DESCRIPTION OF SYMBOLS CARING FOR THE ENVIRONMENT
Power tools that are no longer usable should not be disposed
of with household waste but in an environmentally friendly way.
Please recycle where facilities exist. Check with your local
council authority for recycling advice.
Recyclingpackagingreducestheneedforlandllandraw
materials. Reuse of recycled material decreases pollution in the
environment. Please recycle packaging where facilities exist.
Check with your local council authority for recycling advice.
Spare parts can be ordered from the Special Orders Desk
at your local Bunnings Warehouse.
For further information, or any parts not listed here, visit
www.ozito.com.au or contact Ozito Customer Service:
Australia 1800 069 486
New Zealand 0508 069 486
E-mail: [email protected]
SPARE PARTS
IP65
Problem Possible Cause Solution
The pump operates
but water is not
owing
There is air in the pump head Disconnectfrompowersupply,opentheprimingscrewandllthe
pump head with water
VerifythejointsaresealedtightlywithTeontape
The suction pipe is blocked Disconnect from power supply, clean the suction pipe
The pump is not primed Following instructions “Priming The Pump”
Theexternalin-linelterisblocked(ifinstalled). Cleanthelter
The inlet and outlet are not connected with the pipe or
hose correctly
Connect the inlet and outlet with pipe or hose correctly, ensure
thereisnoleakage.UseTeontapeonallconnections.
Nowaterowfromsupply Checkifthesupplysourcehassufcientwater
The pump won’t start Power not switched on If the green light doesn’t illuminate, check the mains supply
Restart button has not been pressed Whenthepumprequiresrestating(Failurelightilluminatesred),
push the Restart button and hold for 5 seconds to re-start the
pump, the red failure light should turn off.
Pump stops The mains power is disconnected Check the mains power
Power failure When power is restored, the green light will illuminate, press the
Restart button
There is air in the pump head Disconnectfrompowersupply,opentheprimingscrewandllthe
pump with water
VerifyalljointsaresealedtightlywithTeontape
The suction pipe is blocked Disconnect from power supply, clean the suction pipe
The pump is not primed Follow instructions “Priming The Pump”
Theexternalin-linelterisblocked(ifinstalled) Cleantheexternallter
The inlet and outlet are not connected with the pipe or
hose correctly
Connect the inlet and outlet with pipe or hose correctly, ensure
thereisnoleakage.UseTeontapeonallconnections
Nowaterowfromsupply Check if the tank has plenty of water
System has reached preset cut off pressure This is normal operation. The pump will start automatically once
the outlet system pressure is below 1.5 bar. Open outlet.
The failure light
continues to
illuminate red after
pressing the restart
button
Air leak in the suction line Checkthesuctionlineconnectionsforairleaksandtightenorx
where found.
The pump doesn’t build up enough pressure to
operate.
Checkthesuctionlineconnectionsforairleaksandtightenorx
where found.
Chack the water source tank has water in it.
Electrical fault with the pump Contact Ozito Customer Service
TROUBLESHOOTING

WARNING! This product is intended for pumping water in a Home Domestic
application. Do not use it for corrosive, abrasive, explosive or dangerous liquids.
Fluids other than water will damage the water pump and/or create a re hazard. Failure to
follow all instructions listed below may result in electric shock, re and/or serious injury.
WARNING! This product is not suitable for use with drinking (potable) water.
This appliance is not intended for use by person (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
• Ensure the water pump is disconnected from mains power when installing.
• Donotinstalloroperatethewaterpumpinanexplosiveenvironmentornearammable
material.
• Donotoperatethewaterpumpwithoutliquid.
• Do not run the water pump dry.
WARNING! The water pump together with associated pipework operate under
pressure. Do not disconnect water pump or pipework until internal pressure
has been released. Failure to do this could result in personal injury and damage to
property.
• Avoid inserting hands into the inlets/outlets of the water pump while it is connected to
power.
• Before using the water pump, always inspect it visually. Do not use the pump if it is
cracked and/or damaged. If the water pump is damaged, contact Ozito customer service.
• The water pump has a built-in thermal protection overload switch. The water pump stops
if an overload occurs. The motor restarts automatically after it has cooled down.
• The pump must not be used when people are in the water.
• Neverworkorperformmaintenanceonthepumpwithoutrstmakingsureithasbeen
disconnected from the mains power.
• Pollutionoftheliquidcouldoccurduetoleakageoflubricants
IMPORTANT:
• Avoid inserting hands into the mouth of the pump if it is connected to the mains.
• The electrical connection must always be made in a dry area. Make sure that electrical
connections are protected from inundations.
• Protect the plug and the power cable from heat, oil or sharp edges.
• Ifdamaged,Thepowercablemustbereplacedbyaqualiedelectrician.
• When operating in swimming pools, garden ponds and similar places, the device must be
provided with a residual current of not more than 30 mA by means of a residual-current-
operated protective device.
PRESSURE PUMP SAFETY WARNINGS
WARNING! When using mains-powered tools, basic safety precautions,
including the following, should always be followed to reduce risk of re,
electric shock, personal injury and material damage.
Read and understand the manual prior to operating this pump.
Save these instructions and other documents supplied with this pump for future reference.
The electric motor has been designed for 230V and 240V only. Always check that the power
supply corresponds to the voltage on the rating plate.
Note: The supply of 230V and 240V on Ozito pumps are interchangeable for Australia and
New Zealand. This pump is earthed in accordance with AS/NZS 60335-2-41.
Note: The power outlet used for the water pump must be protected by a 30mA residual
current device or earth leakage circuit breaker. If the power outlet is external, ensure that
it is weather proof. If the supply cord is damaged, it must be replaced by an electrician or
a power tool repairer to avoid a hazard. The water pump has a built-in thermal protection
overload switch. The water pump stops if an overload occurs. The motor restarts
automatically after it has cooled down.
Using an Extension Lead
Always use an approved extension lead suitable for the power input of this product.
Before use, inspect the extension lead for signs of damage, wear and ageing. Replace the
extension lead if damaged or defective. Then using an extension lead on a reel, always
unwind the lead completely. Use of an extension lead not suitable for the power input of this
productorwhichisdamagedordefectivemayresultinariskofreandelectricshock.
WARNING! Read all safety warnings and all instructions. Failure to follow the
warningsandinstructionsmayresultinelectricshock,reand/orseriousinjury.
Save all warnings and instructions for future reference. The term “power tool” in
the warnings refers to your mains-operated (corded) power tool or battery-operated
(cordless) power tool.
1. Work area safety
a. Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b. Do not operate power tools in explosive atmospheres, such as in the presence of
ammable liquids, gases or dust. Power tools create sparks which may ignite the dust
or fumes.
c. Keep children and bystanders away while operating a power tool. Distractions can
cause you to lose control.
2. Electrical safety
a. Power tool plugs must match the outlet. Never modify the plug in any way.
Do not use any adapter plugs with earthed (grounded) power tools.Unmodied
plugs and matching outlets will reduce risk of electric shock.
b. Avoid body contact with earthed or grounded surfaces, such as pipes, radiators,
ranges and refrigerators. There is an increased risk of electric shock if your body is
earthed or grounded.
c. Do not expose power tools to rain or wet conditions. Water entering a power tool will
increase the risk of electric shock.
d. Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the
power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged
or entangled cords increase the risk of electric shock.
e. When operating a power tool outdoors, use an extension cord suitable for outdoor
use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
f. If operating a power tool in a damp location is unavoidable, use a residual current
device (RCD) protected supply. Use of an RCD reduces the risk of electric shock.
3. Personal safety
a. Stay alert, watch what you are doing and use common sense when operating a
power tool. Do not use a power tool while you are tired or under the inuence of
drugs, alcohol or medication. A moment of inattention while operating power tools may
result in serious personal injury.
b. Use personal protective equipment. Always wear eye protection. Protective
equipmentsuchasdustmask,non-skidsafetyshoes,hardhat,orhearingprotection
used for appropriate conditions will reduce personal injuries.
c. Prevent unintentional starting. Ensure the switch is in the off-position before
connecting to power source and/or battery pack, picking up or carrying the tool.
Carryingpowertoolswithyourngerontheswitchorenergisingpowertoolsthathave
the switch on invites accidents.
d. Remove any adjusting key or wrench before turning the power tool on.
A wrench or a key left attached to a rotating part of the power tool may result
in personal injury.
e. Do not overreach. Keep proper footing and balance at all times. This enables better
control of the power tool in unexpected situations.
f. Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing
and gloves away from moving parts. Loose clothes, jewellery or long hair can be
caught in moving parts.
g. If devices are provided for the connection of dust extraction and collection
facilities, ensure these are connected and properly used. Use of dust collection can
reduce dust-related hazards.
4. Power tool use and care
a. Do not force the power tool. Use the correct power tool for your application. The
correct power tool will do the job better and safer at the rate for which it was designed.
b. Do not use the power tool if the switch does not turn it on and off. Any power tool
that cannot be controlled with the switch is dangerous and must be repaired.
c. Disconnect the plug from the power source and/or the battery pack from the
power tool before making any adjustments, changing accessories, or storing
power tools. Such preventive safety measures reduce the risk of starting the power tool
accidentally.
d. Store idle power tools out of the reach of children and do not allow persons
unfamiliar with the power tool or these instructions to operate the power tool.
Power tools are dangerous in the hands of untrained users.
e. Maintain power tools. Check for misalignment or binding of moving parts,
breakage of parts and any other condition that may affect the power tool’s
operation. If damaged, have the power tool repaired before use. Many accidents are
caused by poorly maintained power tools.
f. Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp
cutting edges are less likely to bind and are easier to control.
g. Use the power tool, accessories and tool bits etc. in accordance with these
instructions, taking into account the working conditions and the work to be
performed. Use of the power tool for operations different from those intended could
result in a hazardous situation.
5. Service
a. Have your power tool serviced by a qualied repair person using only identical
replacement parts. This will ensure that the safety of the power tool
is maintained.
b. If the supply cord is damaged, it must be replaced by the manufacturer,
itsserviceagentorsimilarlyqualiedpersonsinordertoavoidahazard.
GENERAL POWER TOOL SAFETY WARNINGS
ELECTRICAL SAFETY
Table of contents