SPECIFICATIONS
Motor: 600W
Max. Flow Rate: 3,600l/h
Max. Lift 8m
Max. Head: 40m
Outlet & Inlet: 25mm (1”)Female
Max. Delivery Pressure: 4.0 bar
Water Temp.: 1°C - 35°C
Hmin=: 2m
Weight: 10kg
TRP-650
WHAT’S IN THE BOX
Transfer Water Pump
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from the
original date of purchase and is intended for DIY (Do It Yourself)
use only. If a product is defective it will be replaced in accordance
with the terms of this warranty. Warranty excludes consumable
parts, for example: O-rings, bearing, seals gaskets.
WARNING
The following actions will result in the warranty being void.
• If the tool has been operated on a supply voltage other
than that specified on the tool.
• If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
• Failure to perform maintenance as set out within the
instruction manual.
• If the tool is disassembled or tampered with in any way.
INSTALLATION
TROUBLESHOOTING
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
The benefits provided under this warranty are in addition
to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded
at law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Generally you will be responsible for all costs associated with
a claim under this warranty, however, where you have suffered
any additional direct loss as a result of a defective product you
may be able to claim such expenses by contacting our customer
service helpline above.
ozito.com.au
1113
WARNING!
The input hose or pipe should be low enough in the water to ensure that if the
water level falls, the pump will not run dry. Ensure that this is checked when in operation.
NOTE: A leaking hose or pipe will draw in air and therefore not draw in any water.
Positioning the Hose or Pipe
Position the input hose or pipe so that it rises from the water drawing source to the pump. Avoid
positioning the input hose or pipe higher than the pump, as this would delay the escape of air
bubbles from the input hose or pipe and impede the priming process (see section ‘starting the
pump’ for description on priming the pump)
Problem Possible Cause Solution
The pump does not start,
or pump water
Pump is not connected to the power supply
Pump is blocked
Pump is not connected to the water supply
Check that the pump is connected to the mains power supply
Disconnect the pump from the mains power. Inspect the discharge outlet and lter
Ensure the pump is connected to the water supply
The pump does not supply water
when the motor is running
The pump has not been primed
Suction line is leaking
The pump is sucking air
Pump is blocked
Pump is not producing enough pressure
Water source does not have enough water
The suction height is too high
The hose diameter is too small
Fill the pump with water, ensure the suction line and pump are lled with water
Check the suction line for leaks and replace hose or pipe if it is damaged or worn
Ensure all connections and ttings are secured tightly
Disconnect the mains power and check the discharge outlet and lter for any foreign matter
Check all parts of the pump and clean
Wait until the water source increases so the pump can operate
Ensure the suction height is no higher than 8m
Ensure the hose diameter is at least 25mm (suction line) and 19mm (discharge line)
Tube or piping does not stay on
the male thread when water is
travelling through
The hose or tubing may be worn or vary
slightly with the dimensions
Add a hose clamp to prevent leaks and secure the hose or pipe
The pump operates intermittently
There is a water leak in the household
plumbing
The voltage is out of range
Air ow is not allowing the motor to cool
The motor is faulty or damaged l
Inspect and x any leaks
Supply the pump in accordance with the rating label requirements
(230-240V)
Ensure the pump is in a well ventilated area
Contact Ozito customer service
Poor Performance
low pressure ow
Faulty suction line Check all the suction lines for leaks or any damage. Replace if they are faulty and check that
you are using a reinforced hose to prevent the hose from collapsing
DESCRIPTION OF SYMBOLS
CARING FOR THE ENVIRONMENT
Power tools that are no longer usable should not be disposed of
with household waste but in an environmentally friendly way. Please
recycle where facilities exist. Check with your local council authority
for recycling advice.
Recycling packaging reduces the need for landll and raw materials.
Reuse of recycled material decreases pollution in the environment.
Please recycle packaging where facilities exist. Check with your
local council authority for recycling advice.
Spare parts can be ordered from the Special Orders Desk
at your local Bunnings Warehouse.
For further information, or any parts not listed here, visit
www.ozito.com.au or contact Ozito Customer Service:
Australia 1800 069 486 New Zealand 0508 069 486
SPARE PARTS
ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS
WARNING! Read all safety warnings and all instructions. Failure to follow the warnings and
instructions may result in electric shock, re and/or serious injury.
Save these instructions
1. Work area safety
a. Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b. Donotoperatepumpsinexplosiveatmospheres,suchasinthepresenceofammableliquids,
gases or dust. Pumps create sparks which may ignite the dust or fumes.
c. Keep children and bystanders away while operating a pump. Distractions can cause you to lose control.\
2. Electrical safety
a. Pump plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs
with earthed (grounded) pumps. Unmodied plugs and matching outlets will reduce risk of electric shock.
b. Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
c. Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the pump. Keep cord
away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of
electric shock.
d. When operating a pump, use an extension cord suitable for wet conditions. Use of a cord suitable for
wet use reduces the risk of electric shock.
e. If operating a pump, use a residual current device (RCD) protected supply. Use of an RCD reduces the
risk of electric shock.
3. Personal safety
a. Stay alert, watch what you are doing and use common sense when operating a pump. Do not use
apumpwhileyouaretiredorundertheinuenceofdrugs,alcoholormedication. A moment of
inattention while operating a pump may result in serious personal injury.
b. Avoid accidental starting. Ensure the switch is in the off position before plugging in. Carrying pump
with your nger on the switch or plugging in pumps that have the switch on invites accidents.
c. Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
d. When operating a pump outdoors, use an extension cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of electric shock.
4. Pump use and care
a. Disconnect the plug from the power source before making any adjustments, changing accessories,or
storing pumps. Such preventive safety measures reduce the risk of starting the pump accidentally.
b. Maintain pumps. Check for misalignment or binding of moving parts, breakage of parts and any other
condition that may affect the pumps operation. If damaged, have the pump repaired before use. Many
accidents are caused by poorly maintained pumps.
c. Use the pump, and accessories etc., in accordance with these instructions and in the manner
intended for the particular type of pump, taking into account the working conditions and the work to
be performed. Use of the pump for operations different from intended could result in a hazardous situation.
5. Service
a. Haveyourpumpservicedbyaqualiedrepairpersonusingonlyidenticalreplacementparts.This will
ensure that the safety of the pump is maintained.
b. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualied persons in order to avoid a hazard.
GENERAL SAFETY WARNINGS
ELECTRICAL SAFETY
WARNING! This product is intended for pumping water in a Home Domestic application.
Do not use it for corrosive, abrasive, explosive or dangerous liquids. Fluids other than water
willdamagethewaterpumpand/orcreatearehazard.Failuretofollowallinstructionslisted
belowmayresultinelectricshock,reand/orseriousinjury.
WARNING! This product is not suitable for use with drinking (potable) water.
This appliance is not intended for use by person (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
• Ensurethewaterpumpisdisconnectedfrommainspowerwheninstalling.
• Donotinstalloroperatethewaterpumpinanexplosiveenvironmentornearammablematerial.
• Donotoperatethewaterpumpwithoutliquid.
• Donotrunthewaterpumpdry.
WARNING! The water pump together with associated pipework operate under pressure. Do not
disconnect water pump or pipework until internal pressure has been released. Failure to do this
could result in personal injury and damage to property.
• Avoid inserting hands into the inlets/outlets of the water pump while it is connected to power.
• Before using the water pump, always inspect it visually. Do not use the pump if it is cracked and/or damaged.
If the water pump is damaged, contact Ozito customer service.
• The water pump has a built-in thermal protection overload switch. The water pump stops if an overload
occurs. The motor restarts automatically after it has cooled down.
• The pump must not be used when people are in the water.
• Never work or perform maintenance on the pump without rst making sure it has been disconnected from the
mains power.
• Pollution of the liquid could occur due to leakage of lubricants Important:
Avoid inserting hands into the mouth of the pump if it is connected to the mains.
The electrical connection must always be made in a dry area. Make sure that electrical connections are protected
from inundations.
Protect the plug and the power cable from heat, oil or sharp edges.
If damaged, The power cable must be replaced by a qualied electrician.
WARNING! When using mains-powered tools, basic safety precautions, including the
following,shouldalwaysbefollowedtoreduceriskofre,electricshock,personalinjuryand
material damage.
Read and understand the manual prior to operating this pump.
Save these instructions and other documents supplied with this pump for future reference. The electric motor has
been designed for 230V and 240V only. Always check that the power supply corresponds to the voltage on the
rating plate.
Note: The supply of 230V and 240V on Ozito pumps are interchangeable for Australia and New Zealand. This
pump is earthed in accordance with AS/NZS 60335-2-41.
Note: The power outlet used for the water pump is recommended to be protected by a 30mA residual current
device or earth leakage circuit breaker. If the power outlet is external, ensure that it is weather proof. If the supply
cord is damaged, it must be replaced by an electrician or a power tool repairer to avoid a hazard. The water pump
has a built-in thermal protection overload switch. The water pump stops if an overload occurs. The motor restarts
automatically after it has cooled down.
Using an Extension Lead
Always use an approved extension lead suitable for the power input of this product. Before use, inspect the
extension lead for signs of damage, wear and ageing. Replace the extension lead if damaged or defective. Then
using an extension lead on a reel, always unwind the lead completely. Use of an extension lead not suitable for
the power input of this product or which is damaged or defective may result in a risk of re and electric shock.
V Volts Hz Hertz
~ Alternating current WWatts
/min Revolutions or noNo load speed
reciprocation per minute
l Litres ºC Degrees celsius
p/hr Per hour kPa Pressure rating (kilopascals)
bar Pressure rating FInsulation class