PACSystems RX3i User manual

PACSystems* RX3i CEP Carrier
Important Product Information
GFK-2884D IC695CEP001 & IC694CEE001
June 2015
* Indicates a trademark of General Electric Company and/or its subsidiaries. All other trademarks are the property of
their respective owners.
Copyright © 2014-2015 by General Electric Company. All Rights Reserved.
The PACSystems* RX3i Carrier IC695CEP001 interfaces
a remote node, consisting of one RX3i I/O module, to a
PROFINET I/O Local Area Network (LAN).
The optional RX3i Expansion Carrier IC694CEE001
attaches to the RX3i CEP001 Carrier and provides the
ability to add one additional RX3i IC694 I/O module to
the remote node.
The RX3i CEP001 Carrier functions as a PROFINET IO-
Device. The RX3i CEP001 Carrier’s main Remote I/O
functions include:
Scanning all the modules within the remote node
(input and output scan)
Publishing data on the PROFINET network to a
PROFINET IO-Controller at a user-specified
production period
Receiving data from a PROFINET IO-Controller on
the PROFINET network at a customer-specified
production period
Managing PROFINET communication and module
configuration between a PROFINET IO-Controller
and modules within the remote node
Managing the state of the I/O when
communications is lost
Publishing fault information (alarms, diagnostics,
and such) to the PROFINET IO-Controller
Provides power to the CEE001 Expansion Carrier
The insertion and removal of I/O modules is the same as in an RX3i Universal Backplane. Refer to GFK-
2314, PACSystems RX3i System Manual.
The RX3i CEP001 Carrier provides two RJ-45 Ethernet receptacles. It supports 10/100BASE-TX Ethernet
standard interface.
Features
Full programming and configuration services for all supported RX3i I/O Modules using Proficy
Machine Edition. Refer to the section, Supported I/O Modules.
Support daisy-chain/line, star, or ring (redundant media) network topologies.
Two switched Ethernet ports: two eight-conductor RJ-45 shielded-twisted pair 10/100 Mbps copper
interfaces.
USB port for field updates of firmware using WinLoader.
Supports Hot-standby CPU Redundancy using PROFINET I/O: requires RX3i CEP001 2.01 GSDML
version 2.3 or later.
Supports HART®Pass Through using PROFINET.
Note: The USB port is for firmware upgrades only. It is not intended for permanent connection.
Note: The CEP001 Carrier requires a user-supplied +24 Vdc power source.
®HART®is a registered trademark of the HART Communication Foundation of Austin, Texas USA. Any use of the term
HART hereafter in this document, or any document referenced by this document, implies the registered trademark.

2 PACSystems* RX3i CEP Carrier
GFK-2884D IC695CEP001 & IC694CEE001
Ordering Information
IC695CEP001
RX3i CEP001 Carrier with RJ-45 Copper Ethernet Interface
IC694CEE001
RX3i CEE001 Expansion Carrier
Specifications
Note: For product standards, general operating specifications, and installation requirements, refer to
GFK-2314, PACSystems RX3i System Manual.
PROFINET support
PROFINET Version 2.3 Class A IO-Device
RX3i Controller version
required
IC695CPU315/CPU320/CPE305/CPE310/CPE330/CRU320, firmware v8.50 or later
IC69PNC001 PROFINET IO-controller with firmware version 2.20 or later
RXi Controller version
required
RXi Controller, ICRXICTL000, with firmware version 7.80 or later is compatible
with CEP001 up to version 2.01, but is not compatible with CEP001 version 2.30.
Proficy Machine Edition
version required
Version 8.6 with SIM 3 or later
Power requirements1
IC695CEP001: 5.25W (0.22 A) at 24 Vdc with or without Expansion Carrier
(IC694CEE001)
DC power supply input range: 19.2 to 30 Vdc
Module dimensions
177.2 x 51 x 35 mm (6.98” x 2.01” x 1.38”). Same for CEP001 and CEE001.
Operating temperature
0°C to 60°C (32°F to 140°F) maximum surrounding air temperature
Number of Ethernet
port connectors
IC695CEP001: Two RJ-45 10/100Base-TX receptacles
IC694CEE001: None
USB connector (for
firmware upgrades)
IC695CEP001: One Micro-B connector. USB 2.0 compliant running at full-speed
(12 MHz) in device mode
IC694CEE001: None
PNS status and control
bits
32 input status bits and 32 output control bits
I/O data update on the
PROFINET LAN
Configurable: 1ms, 2ms, 4ms, 8ms, 16ms, 32ms, 64ms, 128ms, 256ms and
512ms
Number of IP addresses
One; supports Classless Inter-Domain Routing (CIDR)
Number of MAC
addresses
Three; one per external port and one internal. External MAC addresses are only
used for specialized Ethernet protocols such as MRP or LLDP.
I/O station maximum
limits
Number of I/O modules per station
IC695CEP001:
One
IC695CEP001 with IC694CEE001:
Two
I/O data per station
1024 bytes total
512 bytes of input data
512 bytes of output data
Configuration
Configured using Proficy Machine Edition when used with a PACSystems RX3i
PROFINET Controller module as part of an RX3i High-speed I/O LAN system.
V2.3 GSDML file available for import into 3rd-Party tools.
1
Value does not include the power consumption of the installed I/O modules. When calculating the total power
requirements, add the power consumption of the I/O modules according to the I/O module datasheet.

PACSystems* RX3i CEP Carrier 3
IC695CEP001 & IC694CEE001 GFK-2884D
Installation Location
This product is intended for use with the RX3i system. Its components are considered open equipment
(having live electrical parts that may be accessible to users) and must be installed in an ultimate enclosure
that is manufactured to provide safety. At a minimum, the enclosure shall provide a degree of protection
against solid objects as small as 12mm (fingers, for example). This equates to a NEMA/UL Type 1
enclosure or an IEC60529 IP20 rating providing at least a pollution degree 2 environment. For details
about installing RX3i rack systems, refer to PACSystems RX3i System Manual, GFK-2314.
Installation in Hazardous Areas
The following information is for products bearing the UL marking for Hazardous Areas or ATEX marking for
explosive atmospheres:
CLASS 1 DIVISION 2 GROUPS ABCD
This equipment is an open-type device and is meant to be installed in an enclosure suitable for
the environment that is only accessible with the use of a tool.
Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or nonhazardous
locations only.
Warning –EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR
CLASS I, DIVISION 2.
Warning –WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING
MODULES.
ATEX Zone 2
This module must be mounted in an enclosure certified in accordance with EN60079-15 for use in Zone 2,
Group IIC and rated IP54. The enclosure shall only be able to be opened with the use of a tool.

4 PACSystems* RX3i CEP Carrier
GFK-2884D IC695CEP001 & IC694CEE001
Normal Operation of Individual LEDs
Power LEDs
The RX3i CEP001 Carrier has two Power LEDs, PWR1 and PWR2 that indicate whether the power is applied
and is within range corresponding to the two power sources.
Green, ON
Power is applied at the minimum specified level
OFF
The power supply does not have power or has failed.
OK LED
The OK LED indicates whether the CEP001 Carrier is able to perform normal operation.
Green, ON
RX3i CEP001 is OK
Amber, ON
Either the RX3i CEP001 Carrier or IO module has a fault
Amber, blink pattern
Fatal error. Flashes once between error codes.
Fast blinking
CEP001 has no valid MAC addresses
OFF
CEP001 has an unrecoverable fault
Connect LED
The CONN LED indicates the status of PROFINET connections.
Green, ON
At least one PROFINET connection (AR) exists with an IO-Controller
Amber, blink pattern
Fatal error. Flashes once between error codes blinked on the OK LED
Amber, blink in 1Hz
No device name configured
OFF
No PROFINET connection (AR) exists
Port LEDs
The RX3i CEP001 has two Port LEDs, PRT1 and PRT2 that indicate link speed, link connection and link
activity corresponding to the two external Ethernet ports.
Green, ON
Link connected, 100 Mbps
Green, blinking
Port active, 100 Mbps
Amber, ON
Link connected, 10 Mbps
Amber, blinking
Port active, 10 Mbps
Amber, blink pattern
Fatal error. Flashes once between error codes blinked on the OK LED
OFF
The associated Ethernet port is not connected to an active link (can be
disabled by configuration)
Note:Multiple LEDs can blink in patterns that indicate special conditions, such as a request for module
identification. Refer to PACSystems RX3i PROFINET Scanner IC695CEP001 User Manual, GFK-2883.
Power LED (IC694CEE001)
The RX3i Expansion Carrier CEE001 has one PWR LED to indicate whether the power provided by the RX3i
CEP001 Carrier is within range.
Green, ON
OK
Amber, ON
Power 24Vdc and/or 5Vdc is not in specified range
OFF
No power

PACSystems* RX3i CEP Carrier 5
IC695CEP001 & IC694CEE001 GFK-2884D
Quick Start
Carrier Installation Requirements
The CEP001 Carrier and optional Expansion Carrier CEE001
can be mounted on a DIN-rail or on a panel.
Adequate installation space is required for:
1. Clearance for communications port cables.
2. Power wiring.
3. Operating the DIN latch.
The RX3i CEP001 Carrier with an I/O module attached requires
an enclosure with minimum depth of 165 mm.
Rated thermal specifications are based on a clearance of
5.1 cm (2”) above and below the equipment and 2.54 cm (1”) to
the left of the RX3i CEP001 Carrier.
Connecting the CEE001 Expansion Carrier to the CEP001 Carrier
1. Open the connector cap on the RX3i CEP001 Carrier.
2. Slide and install the RX3i CEE001 Expansion Carrier along the guide slots on the RX3i CEP001 Carrier.
3. When the Expansion Carrier is aligned with the CEP001 Carrier, engage the expansion connectors.
4. Close the connector cap.
5. Secure the Expansion Carrier to the DIN rail or panel. Refer to Installing an RX3i CEP001 Carrier on a
DIN-rail or Panel Mounting.
6. Connect the grounding hole on the CEE001 to the panel or enclosure as described in Grounding
below.

6 PACSystems* RX3i CEP Carrier
GFK-2884D IC695CEP001 & IC694CEE001
Installing an RX3i CEP001 Carrier on a DIN-rail
The carrier mounts on a standard EN 50022,
35 x 7.5 mm DIN-rail. Conductive (unpainted) finish is
required for proper grounding.
For best resistance to vibration, the DIN-rail should be
installed horizontally on a panel using screws spaced
approximately 15 cm (6”) apart.
1. With a small flathead screwdriver, pull out the two DIN-rail latches and stand the carrier on the DIN-
rail.
2. Push in the two DIN-rail latches so that the latches hold the DIN-rail.
Panel Mounting
For applications requiring maximum or long term resistance to mechanical vibration and shock, the
panel-mounting method is strongly recommended. A minimum panel thickness of 2.4 mm (.093”) is
required. The mounting diagram below applies to both the CEP001 Carrier and CEE001 Expansion Carrier.
Note 1: Tolerances on all dimensions are ±0.2 mm (0.078”) non-cumulative.
Note 2: Apply 1.1 to1.4 Nm (10 to12 in/lbs) of torque to M3.5 (#6-32) steel screws threaded into tapped
holes in the panel.

PACSystems* RX3i CEP Carrier 7
IC695CEP001 & IC694CEE001 GFK-2884D
Grounding
Warning
All CEP001 Carriers in a system must be grounded to minimize electrical shock hazard.
Failure to do so can result in severe personal injury.
The RX3i CEP001 Carrier and CEE001 Expansion Carrier each provide two grounding connection contacts:
Grounding clips at the back of the carrier, which require DIN-rail installation
Grounding screw hole at bottom-left of the carrier
Note:When the Carrier is mounted on a DIN-rail, the grounding clips on the back of the Carrier do not
provide an adequate ground connection. The Carrier’s metal back must also be grounded using a
separate conductor.
Ground each Carrier to the panel or enclosure using a minimum AWG #12 (3.3 mm2) wire with ring
terminals. Use an M3 screw, star lock washer and a flat washer to connect the wire at the Carrier’s
grounding hole. Connect the other end of the ground wire to a tapped hole in the grounded mounting
panel or enclosure, using a machine screw, star lock washer and flat washer. Alternately, if the panel has
a ground stud, use a nut and star lock washer for each wire on the ground stud to ensure adequate
grounding. Where connections are made to a painted panel, the paint should be removed so clean, bare
metal is exposed at the connection point. Terminals and hardware used should be rated to work with the
aluminum carrier material.
Note:The star lock washer method is suitable for a shield ground, but not suitable for a safety ground.

8 PACSystems* RX3i CEP Carrier
GFK-2884D IC695CEP001 & IC694CEE001
Installing Modules on the Carrier
The insertion and removal of I/O modules is the same as in an RX3i Universal Backplane. For details, refer
to GFK-2314, PACSystems RX3i System Manual.
Caution
Do not install a Power Supply module on the CEP001 or CEE001 Carrier. Attempting to do so
could damage the module and/or the Carrier.
Unsupported Modules
Caution
If an unsupported module is inserted in the CEP001 or CEE001 Carrier, the module will not
be recognized correctly and could cause damage to the Carrier or the module.
When an unsupported I/O module is inserted into either the RX3i CEP001 Carrier or RX3i CEE001
Expansion Carrier, no alarm is reported to indicate this.
For the latest updated list of supported I/O modules, refer to the section, Supported I/O Modules.
Some unsupported I/O modules have the same Distinguishing Class (for example, IC694MDL740 has the
same Distinguishing Class as IC694MDL742).

PACSystems* RX3i CEP Carrier 9
IC695CEP001 & IC694CEE001 GFK-2884D
Connecting Power Supplies
You will need:
Note: Two power supplies are required if using redundant power supplies.
One 24 Vdc power supply which provides a low voltage/limited current (LVLC) power source. (For
example, the combination of an isolated DC supply and a fuse, listed 30 Vdc minimum and 3 A
maximum, connected in series with the input.)
Power cord with 28 to16 AWG / 0.08 to1.32 mm2wires
Ferrules for 28 to16 AWG wires (optional)
Frame ground wire, 28 to16 AWG
Input power terminal block; provided (WAGO Part Number 713-1103)
Small flathead screwdriver (jeweler’s size 14)
Note:For CE Mark purposes, input power lines to the CEP001 Carrier should be limited 30 m (98 ft)
or less.
Note:Before inserting the wires into the power connector terminal block, use a small flathead
screwdriver to release the spring clamp on the terminal block.
1. Using the power cord, attach the power supply to the power terminal
block as displayed in the following figure.
Recommended wire stripping length is 6 to7 mm (0.25”).
2. If using redundant power supplies, connect the second power supply to
the input power terminal block.
3. Insert the input power terminal block into the Input Power connector.
Note:There are no user-serviceable fuses in the CEP001 Carrier.
Connecting Power to RX3i CEP001 Carrier

10 PACSystems* RX3i CEP Carrier
GFK-2884D IC695CEP001 & IC694CEE001
Adding a Redundant Power Supply
To add a redundant power supply to a system that is already in operation
1. Remove power from the primary power supply to the RX3i CEP001 carrier
2. Remove the power terminal block from the carrier.
3. Without disturbing the primary power supply input lines, connect the redundant power supply
input lines to the power terminal block.
4. Insert the power terminal block into the Input Power connector.
5. Apply power to the redundant power supply. The PWR2 LED on the RX3i CEP001 carrier should
turn on.
6. Apply power to the primary power supply. The PWR1 LED on the CEP001 Carrier should turn on.
Note:For the procedure to swap a redundant power supply, refer to PACSystems RX3i PROFINET
Scanner IC695CEP001 User Manual, GFK-2883.
Connecting the CEP001 to the PROFINET Network
The two external RJ-45 Ethernet ports, which provide 10/100 Mbps copper interfaces, are on the bottom
of the CEP001 Carrier.
Devices connected to the RX3i CEP001 ports should have Ethernet Auto-negotiation enabled. The RX3i
CEP001 Carriers and other participating devices can be connected in a daisy-chain/line, or star topology.
Caution
Do not connect both ports on the Ethernet interface, directly or indirectly, to the same device
so as to form a circular network unless Media Redundancy is enabled with one node actively
set up as the Media Redundancy Manager.
Supported Network Media Types and Distances
PROFINET I/O over-wired infrastructure must be 100Mbps full-duplex or faster. The hardware is capable of
operating at 10Mbps but should not be used for PROFINET.
Media Type
Connector
Type
Wavelength
(nm)
Media Type
Core
Size
(μm)
Modal
Bandwidth
(MHz –Km)
Maximum
Distance
10/100BASE-TX
RJ-45
-
CAT5/CAT5e/CAT6
-
-
100 m (328 ft)

PACSystems* RX3i CEP Carrier 11
IC695CEP001 & IC694CEE001 GFK-2884D
Assigning an I/O Device Name to the CEP001
Before attempting to connect to or configure the CEP001, the I/O Device Name must be set with a
Discovery and Configuration Protocol (DCP) tool.
Configuring the CEP001/CEE001 Node and Resident I/O Modules on a PROFINET Network
Proficy Machine Edition is the primary tool used to configure an RX3i PROFINET network. The GSDML file
for the RX3i CEP001 is included with Proficy Machine Edition, or may be downloaded from the support
website at http://support.ge-ip.com. To obtain the GSDML for import into a 3rd-Party tool, contact GE.
Supported I/O Modules
The following table indicates the minimum CEP001 firmware version required for compatibility with the
listed I/O modules and whether the module can be installed in the RX3i Expansion Carrier CEE001.
Catalog
Number
Module Description
Distin-
guishing
Classes2
Earliest
CEP001
Compatible
Version
CEE0013
Comp-
atible
Discrete Input Modules
IC693MDL230
120 Vac Isolated Input (8 Points)
8 in
2.30
Y
IC693MDL240
120 Vac Input (16 Points)
16 in
2.30
Y
IC693MDL632
125 Vdc Input Pos/Neg Logic (8 Points)
8 in
2.30
Y
IC693MDL635
125 Vdc Input Pos/Neg Logic (16 Points)
16 in
2.30
Y
IC693MDL648
48 Vdc Input Pos/Neg Fast (16 Points)
16 in
2.30
Y
IC693MDL660
24 Vdc High-Density Input (32 Points)
32 in
2.30
Y
IC694MDL230
120 Vac Isolated Input (8 Points)
8 in
2.30
Y
IC694MDL240
120 Vac Input (16 Points)
16 in
2.30
Y
IC694MDL250
120 Vac Isolated Input (16 Points)
None
1.00
Y
IC694MDL632
125 Vdc Input Pos/Neg Logic (8 Points)
8 in
2.30
Y
IC694MDL635
125 Vdc Input Pos/Neg Logic (16 Points)
16 in
2.30
Y
IC694MDL646
24 Vdc Input, Pos/Neg Logic, 1 ms Filter (16 Points)
16 in
1.00
Y
IC694MDL648
48 Vdc Input Pos/Neg Fast (16 Points)
16 in
2.30
Y
IC694MDL660
24 Vdc High-Density Input (32 Points)
32 in
2.30
Y
IC695MDL664
Digital Input Module with Diagnostics –(16 Points)
None
1.00
N
Discrete Output Modules
IC693MDL390
120/240 Vac Isolated Output 2A (5 Points)
None
2.30
Y
IC693MDL754
24 Vdc High-Density Output (32 Points) Diagnostics Off
32 out
2.30
Y
IC693MDL754
24 Vdc High-Density Output (32 Points) Diagnostics On
32 in/32 out
2.30
Y
IC693MDL930
Relay Output N.O. 4 A Isolated (8 Points)
8 out
2.30
Y
IC693MDL940
16 Circuit Output 2A Relay
16 out
2.30
Y
IC694MDL390
120/240 Vac Isolated Output 2A (5 Points)
None
2.30
Y
IC694MDL742
12/24 Vdc Output, 1 A, Positive Logic (16 Points), Fused
16 out
1.00
Y
IC694MDL754
24 Vdc High-Density Output with ESCP (32 Points)
None
2.30
Y
IC694MDL916
Relay Output 4 A (16 Points)
None
1.00
Y
IC694MDL930
Relay Output N.O. 4 A Isolated (8 Points)
8 out
2.30
Y
IC694MDL940
16 Circuit Output 2A Relay
16 out
2.30
Y
IC695MDL765
Digital Output Module with Diagnostics (16 Points)
None
1.00
N
Mixed Discrete Input/Output Modules
IC693MAR590
120 Vac Input (8 Points) / Relay Output (8 Points)
8 in/8 out
2.30
Y
2
The RX3i CEP001 Carrier and the RX3i CEE001 Expansion Carrier cannot distinguish between modules within the
same Distinguishing Class type. This means that any module physically present that is in the same class as the one
configured will not alert the user with a System Configuration Mismatch fault on the Controller Fault Table.
3
CEE001 supports IC693 and IC694 series I/O modules, but not IC695 series.

12 PACSystems* RX3i CEP Carrier
GFK-2884D IC695CEP001 & IC694CEE001
Catalog
Number
Module Description
Distin-
guishing
Classes2
Earliest
CEP001
Compatible
Version
CEE0013
Comp-
atible
Analog Input Modules
IC695ALG112
Analog Input Isolated Current/Voltage (12 channels)
None
2.01
N
IC695ALG600
Universal Analog Input: RTD, Thermocouple, Resistance,
Current/Voltage (8 Channels)
None
2.01
N
IC695ALG616
Analog Input, Current/Voltage, Configurable,
(16 Channels)4
None
1.00
N
IC695ALG626
Analog Input with HART Communications,
Current/Voltage, Configurable, (16 Channels)4,5
None
1.006
N
Analog Output Modules
IC695ALG728
Analog Output with HART Communications,
Current/Voltage, (8 Channels)4,5
None
1.006
N
IC695ALG808
Analog Output Isolated, Current/Voltage, (8 Channels)4
None
1.00
N
Analog Mixed Modules
IC693ALG442
Analog Current/Voltage 4-Input/2-Output
ALG IN 4,
ALG OUT 2
2.30
N
IC694ALG442
Analog Current/Voltage 4-Input/2-Output
ALG IN 4,
ALG OUT 2
2.30
N
Specialty Modules
IC694PSM001
Power Sync and Measurement System
None
2.01
Y
4
The RX3i CEP001 Carrier and the RX3i CEE001 Expansion Carrier do not support Interrupts from this module.
5
The RX3i CEP001 Carrier does not support HART features which are logic-driven. HART data obtained via HART Pass
Through is available.
6
RX3i CEP001 version 2.30 is required for HART Pass Through functionality. Refer to additional Compatibility
information below.

PACSystems* RX3i CEP Carrier 13
IC695CEP001 & IC694CEE001 GFK-2884D
Important Product Information
Release History
Version
Firmware
Release
Date
Comments
IC695CEP001-AAAD
2.30
June
2015
Added support for additional I/O Modules (see Supported I/O
Modules above) and for HART Pass Through functionality.
IC695CEP001-AAAC
2.01
Nov
2014
Added Hot-standby CPU redundancy using PROFINET I/O and
support for additional RX3i I/O modules: IC695ALG112,
IC695ALG600, and IC694PSM001
IC695CEP001-AAAA
1.00
Jan
2014
Initial release
Upgrades
Upgrade kit: 41G1897-MS10-000-A2.zip is available at http://support.ge-ip.com.
Compatibility
The PROFINET Scanner modules require the CPU firmware and programming software versions listed in
the following table.
Proficy Machine Edition
Proficy Machine Edition version 8.6 SIM 3 or later
RX3i CPU Version
PACSystems RX3i CPU, IC695CPU315/CPU320/CPE305/CPE310/CPE330/
CRU320, with firmware version 8.50 or later
RX3i PNC Version
PACSystems RX3i PROFINET IO-Controller, IC695PNC001, with firmware
version 2.20 or later
RXi Controller Version
Effective with IC695CEP001 Firmware version 2.30, the PACSystems RXi
Distributed I/O Controller, ICRXICTL000, is no longer compatible with
IC695CEP001. ICRXICTL000 with firmware version 7.80 or later may be used
with CEP001 version 2.01 or earlier.
RX3i I/O Modules
For a complete list of modules supported by the current firmware release,
refer to the section, Supported I/O Modules, above.
HART Pass Through
HART Pass Through entails usage of PC-based applications, RX3i Analog
modules with HART functionality and (optionally) supporting PROFINET
products. HART Pass Through operation is described in the PACSystems HART
Pass Through User Manual, GFK-2929.
Problems Resolved in This Release
Feature
Description
I/O Module revision
codes restriction
For the ALG modules, prior versions of CEP001 did not return the major and
minor revision codes. This issue is resolved with this release.

14 PACSystems* RX3i CEP Carrier
GFK-2884D IC695CEP001 & IC694CEE001
New Features and Enhancements
Feature
Description
Additional RX3i I/O
Modules Supported
For a complete list of modules supported by the current firmware release
(and earlier firmware releases), refer to the section, Supported I/O Modules.
This table also indicates whether a given I/O module is supported in the
expansion carrier (CEE001).
HART Pass Through
The following RX3i analog modules support HART Pass Through functionality:
IC695ALG626
IC695ALG6287
IC695ALG728
If used specifically for HART Pass Through, the supporting RX3i PROFINET
Controller (PNC001) and PROFINET Scanner (PNS001 or CEP001) must also
contain HART-compatible firmware:
IC695PNC001-AK Firmware Release 2.30
IC695PNS001-ABAH Firmware Release 2.30
IC695CEP001-AAAD Firmware Release 2.30.
Restrictions and Open Issues
Restriction / Issue
Description
Pulling and plugging a
module during HSB roll
switch can make the I/O
module not able to be
recognized.
When configuring RX3i CEP001 under PROFINET HSB redundancy, if you pull
the I/O module installed on an RX3i CEP001 while switching the current
primary/backup CPU role, then plug the I/O module back in and switch the
primary/backup CPU role back, the I/O module might be lost.
It is not suggested to pull/plug an I/O module during PROFINET HSB
redundancy roll switch. To recover, cycle power to the RX3i.
Module diagnosis alarms
are not stable, especially
when multiple diagnoses
appear at same time.
Whenever fault reporting is configured for an I/O module, and a fault occurs
and is subsequently resolved, the fault might not be reported via the
PROFINET diagnosis appears / diagnosis disappears alarm sequence. This
situation is more likely to be encountered when multiple alarms occur in
rapid succession. See Diagnosis Disappears alarms may be out of sequence
with Diagnosis Appears alarms below.
When supporting
PROFINET System
Redundancy, set
StartupMode to Advanced
The RX3i CEP001 GSDML does not have the attribute
InterfaceSubmoduleItem/ApplicationRelations/@StartupMode. The default is
Legacy according to the GSDML specification. This setting does not matter
for simplex. However, for PROFINET System Redundancy the StartupMode
needs to be set to Advanced. Refer to Protocol (IEC 61158-6-10) in IO APDU
Substitutions. The SRInfoBlock required for System Redundancy is only
available in IODConnect.Req with StartupMode:=1.
Hot swap of ALG626
module while Online with
attached HART device
causes CEP blink trap 1-2.
Whenever the IC695ALG626 module is hot swapped while online with sixteen
HART devices attached to it, the IC695CEP001 may enter a blink trap1-2. To
recover, cycle power to the CEP001.
7
If used, IC695ALG628 must be installed in the RX3i CPU Rack. At time of publication, it is not supported by PROFINET
scanners IC695PNS001 or IC695CEP001. Refer to IPIs for IC695PNS001 or IC695CEP001 for future updates.

PACSystems* RX3i CEP Carrier 15
IC695CEP001 & IC694CEE001 GFK-2884D
Operational Notes
Note
Description
No alarm report when
inserting an
unsupported I/O
module
Whenever an unsupported I/O module is inserted into either the RX3i CEP001
Carrier or RX3i CEE001 Expansion Carrier, no alarm is reported to indicate this.
For a list of supported I/O modules, refer to the section, Supported I/O Modules
above.
Some unsupported I/O modules have the same Distinguishing Class (for
example, IC694MDL740 has the same Distinguishing Class as IC694MDL742).
If an unsupported module is inserted in the CEP001 or CEE001 Carrier, the
module will not be recognized correctly.
Wait time is too long to
enter download mode
If, while using WinLoader, power is lost to the RX3i CEP001 Carrier during a
firmware update, a delay of more than 50 seconds might be required before the
RX3i CEP001 Carrier can enter the firmware update mode again.
USB port drivers
When connecting the USB cable to the RX3i CEP001 Carrier, you may receive a
warning for installing a driver that has not passed Windows®Logo testing.
Each RX3i CEP001 Carrier is recognized as a separate Windows device with
separate installation, as each has a unique serial number. This is normal
operation for this release.
Network parameters
for IO-devices
If the network parameters (IP Address, subnet mask, and gateway IP) assigned
by the DCP tool are different from the configuration in the IO-Controller and the
IO-Controller is configured to assign IP settings to devices, when the IO
Controller assigns its IP settings, the settings previously stored from the DCP
tool are lost. On a reset, the IO-Device is set to factory default values
(0.0.0.0/0.0.0.0/0.0.0.0) as prescribed by the PROFINET specification.
No Extra Module
alarms
The RX3i CEP001 Carrier and RX3i CEE001 Expansion Carrier ignore all extra
equipment. No Extra I/O Module faults or Loss of I/O Module faults are
generated for unconfigured modules.
Diagnosis Disappears
alarms may be out of
sequence with
Diagnosis Appears
alarms
For RX3i Intelligent modules Diagnosis Disappears alarms are generated by
cyclically polling diagnostic data. These alarms may be slower than Diagnosis
Appears alarms from the same module, which are generated by an interrupt.
Example: When re-applying field power, new channel alarms such as Hi/Low
alarms may occur before the Loss of Field Power alarm clears.
Affected modules are:
IC695MDL664
IC695MDL765
IC695ALG616
IC695ALG626
IC695ALG728
IC695ALG808
CEP001 fails to show
attached I/O module in
PROFINET network
scan when hardware
configuration is absent
If there is no hardware configuration in the controller, and the PROFINET
network is subsequently scanned, the scan may show no I/O module present in
CEP001, even when an I/O module is physically present.
Generic IO module
Whenever an I/O module attached to CEP001 is physically changed, and the
hardware configuration is not updated, the I/O module may show as a
Generic IO module in a subsequent PROFINET network scan.

16 PACSystems* RX3i CEP Carrier
GFK-2884D IC695CEP001 & IC694CEE001
Additional Information
Manuals can be downloaded from the support website at http://support.ge-ip.com.
PACSystems RX3i PROFINET Scanner IC695CEP001 User Manual
GFK-2883
PACSystems RX3i PROFINET Controller User Manual
GFK-2571
PACSystems RX3i PROFINET Controller Command Line Interface Manual
GFK-2572
PACSystems RX7i & RX3i CPU Reference Manual
GFK-2222
PACSystems RX7i & RX3i CPU Programmer’s Reference Manual
GFK-2950
PACSystems RX3i System Manual
GFK-2314
PACSystems RX3i HART Pass Through User’s Manual
GFK-2929
Other manuals for RX3i
4
This manual suits for next models
2
Table of contents
Popular Network Hardware manuals by other brands

Black Box
Black Box Palm-Sized Ethernet Switch Express 8-Port... Specifications

Checkpoint
Checkpoint NGX R66 Getting started guide

HIK VISION
HIK VISION DS-7600NI-12 Series user manual

HIK VISION
HIK VISION DS-7032NI-Q4 user manual

High Sec Labs
High Sec Labs FV11D-M Quick setup guide

Black Box
Black Box 120H user manual