Technical sheet:
KIT. ABOVE BOARD WITH DIVERTER
TECHNICAL CHARACTERISTICS:
- TESTING PRESSURE 12 BAR
- HOT WATER MARK ON THE LEFT RED
- COLD WATER MARK ON THE RIGHT BLUE
LIMITS OF USE CONFORMING TO THE EUROPEAN EN 817 STANDARD
PRESSURE MIN = 0.5 BAR MAX = 10 BAR
TEMPERATURE MAX = 90°
LIMITS OF USE RECOMMENDED BY UNI EN 817 FOR GOOD OPERATION
PRESSURE MIN = 1 BAR MAX = 5 BAR
TEMPERATURE MAX = 65°
WARNINGS:
- THE SYSTEM MUST BE VERY CAREFULLY DRAINED IN ADVANCE TO AVOID DAMAGE TO THE FITTING OR INSTALLED TECHNICAL
DEVICES.
- A CENTRAL FILTER PROTECTS THE SYSTEM FROM IMPURITIES IN THE WATER.
- IN THE CASE OF FEED PRESSURES GREATER THAN 5 BAR, WE RECOMMEND INSTALLING A PRESSURE REDUCER TO PROTECT THE
EQUIPMENT.
PROBLEM POSSIBLE CAUSE SOLUTION
COLD WATER COMES OUT WHEN HOT IS
SELECTED
HOT AND COLD WATER FEEDS ARE REVERSED REVERSE FEED PIPES
LOW FLOW CAPACITYSYSTEM PRESSURE TOO LOW
OUTPUTS OBSTRUCTED
IMPURITIES CLOGGING CARTRIDGE INPUT HOLES
INPUT FILTERS CLOGGED
CHECK THE SYSTEM
CLEAN AERATOR, SHOWERHEAD, ACCESSORIES,
ETC.
DISASSEMBLE THE CARTRIDGE AND CLEAN OR
REPLACE IT
CLEAN INPUT FILTERS
COLD WATER ONLYTHE FEEDS ARE REVERSED
BOILER FAILURE
REVERSE FEED PIPES
CHECK SYSTEM
DIFFICULT TEMPERATURE REGULATION HOT WATER TEMPERATURE TOO LOW
LARGE DIFFERENCE BETWEEN FEED PRESSURES
CHECK THE HOT WATER SUPPLY
BALANCE THE FEED PRESSURES
LEAKS TO THE OUTPUT GASKET SEALS DAMAGED
DIRT BETWEEN SEAL DISKS
CERAMIC DISKS SEVERELY DAMAGED BY IMPURITIES
CHECK THE GASKET SEALS
REPLACE THE CARTRIDGE
REPLACE THE CARTRIDGE
LEAKS BETWEEN CARTRIDGE AND BODY GASKET SEAL DIRTY OR DAMAGED
LOCKNUT HOLDING CARTRIDGE LOOSE
CLEAN OR REPLACE GASKET SEALS
TIGHTEN THE LOCKNUT
SHOWER HEAD LEAKS WHEN WATER IS
COMING OUT OF THE MOUTH
IMPURITIES ON THE DEVIATOR GASKET DISASSEMBLE AND CLEAN OR REPLACE THE
DEVIATOR
LEVER LOOSE THE FIXING GRUB SCREW HAS LOOSENED WITH USE TIGHTEN THE GRUB SCREW
DIMENSIONS: