PaloAlto Networks ION 1200 Series Application guide

ION 1200 Hardware Reference
docs.paloaltonetworks.com

Contact Information
Corporate Headquarters:
Palo Alto Networks
3000 Tannery Way
Santa Clara, CA 95054
www.paloaltonetworks.com/company/contact-support
About the Documentation
• For the most recent version of this guide or for access to related documentation, visit the Technical
Documentation portal docs.paloaltonetworks.com.
• To search for a specific topic, go to our search page docs.paloaltonetworks.com/search.html.
• Have feedback or questions for us? Leave a comment on any page in the portal, or write to us at
Copyright
Palo Alto Networks, Inc.
www.paloaltonetworks.com
© 2021-2022 Palo Alto Networks, Inc. Palo Alto Networks is a registered trademark of Palo
Alto Networks. A list of our trademarks can be found at www.paloaltonetworks.com/company/
trademarks.html. All other marks mentioned herein may be trademarks of their respective companies.
Last Revised
December 12, 2022
ION 1200 Hardware Reference 2©2022 Palo Alto Networks, Inc.

Table of Contents
Before You Begin............................................................................................... 5
Tamper Proof Statement........................................................................................................... 6
Third-Party Component Support............................................................................................. 7
Product Safety Warnings...........................................................................................................8
ION 1200 Overview........................................................................................13
Overview ION 1200.................................................................................................................14
ION 1200 Hardware Specifications......................................................................................16
ION 1200 Front Panel............................................................................................................. 22
ION 1200-C-NA/ROW Front Panel.....................................................................................24
ION 1200-C-5G-WW Front Panel....................................................................................... 26
ION 1200 Back Panel.............................................................................................................. 28
ION 1200-C-NA/ROW Back Panel...................................................................................... 29
ION 1200-C-5G Back Panel...................................................................................................31
ION 1200 Compliance Statement.........................................................................................33
ION 1200-S Front Panel......................................................................................................... 37
ION 1200-S-C-NA/ROW Front Panel................................................................................. 39
ION 1200-S-C5G-WW Front Panel..................................................................................... 41
ION 1200-S Back Panel.......................................................................................................... 43
ION 1200-S-C-NA/ROW Back Panel.................................................................................. 44
ION 1200-S-C-5G Back Panel............................................................................................... 45
ION 1200 LEDs......................................................................................................................... 46
ION 1200-S Compliance Statement.....................................................................................48
Installation Kit Components................................................................................................... 50
Install the ION 1200....................................................................................... 51
Install Antennas......................................................................................................................... 52
Insert SIM Cards........................................................................................................................54
Install the ION 1200 on a Flat Surface............................................................................... 58
Install the ION 1200 on a Wall............................................................................................. 59
Wall Mount Template.............................................................................................................. 63
Install the ION 1200 in a 19-inch Equipment Rack..........................................................64
Install the ION 1200 Using the Racktray............................................................................65
Power on the ION 1200......................................................................................................... 72
Restart the ION 1200...................................................................................................72
Shut Down the ION 1200...........................................................................................72
Install ION 1200-S...........................................................................................73
Insert SIM Cards in the ION 1200-S....................................................................................74
ION 1200 Hardware Reference 3©2022 Palo Alto Networks, Inc.

Table of Contents
Install Antennas in the ION 1200-S..................................................................................... 75
Install the ION 1200-S on a wall.......................................................................................... 77
ION 1200-S Wall Mount Template...................................................................................... 80
Install the ION 1200-S on a Rack.........................................................................................81
Troubleshoot ION 1200.................................................................................87
Troubleshoot Common Issues with the ION 1200...........................................................88
ION 1200 Hardware Reference 4©2022 Palo Alto Networks, Inc.

Before You Begin
Tamper Proof Statement
To ensure that products purchased from Palo Alto Networks were not tampered with during
shipping, verify the following upon receipt of each product:
• The tracking number provided to you electronically when ordering the product matches the
tracking number that is physically labeled on the box or crate.
• The integrity of the tamper-proof tape used to seal the box or crate is not compromised.
• The integrity of the warranty label on the firewall or appliance is not compromised.
ION 1200 Hardware Reference 6©2022 Palo Alto Networks, Inc.

Before You Begin
Product Safety Warnings
To avoid personal injury or death for yourself and others and to avoid damage to your Palo Alto
Networks hardware, be sure you understand and prepare for the following warnings before you
install or service the hardware. You will also see warning messages throughout the hardware
reference where potential hazards exist.
All Palo Alto Networks products with laser-based optical interfaces comply with 21 CFR
1040.10 and 1040.11.
The following safety warnings apply to all Palo Alto Networks firewalls and appliances, unless a
specific hardware model is specified.
• When installing or servicing a Palo Alto Networks firewall or appliance hardware component
that has exposed circuits, ensure that you wear an electrostatic discharge (ESD) strap. Before
handling the component, make sure the metal contact on the wrist strap is touching your skin
and that the other end of the strap is connected to earth ground.
French Translation: Lorsque vous installez ou que vous intervenez sur un composant matériel
de pare-feu ou de dispositif Palo Alto Networks qui présente des circuits exposés, veillez
à porter un bracelet antistatique. Avant de manipuler le composant, vérifiez que le contact
métallique du bracelet antistatique est en contact avec votre peau et que l’autre extrémité du
bracelet est raccordée à la terre.
• Use grounded and shielded Ethernet cables to ensure agency compliance with electromagnetic
compliance (EMC) regulations.
French Translation: Des câbles Ethernet blindés reliés à la terre doivent être utilisés pour
garantir la conformité de l'organisme aux émissions électromagnétiques (CEM).
• I/O ports are intended for intra-building connections only and not intended for OSP (Outside
Plant) connections or any network connections subject to external voltage surge events.
•Radio Frequency (RF) Radiation Exposure Warning: Hazardous Radiation Exposure Warning
—Adjustments or procedures other than those specified may result in hazardous RF radiation
exposure. A minimum distance of 50cm (19.7in) must be maintained between the operating
radio antennas and personnel.
•Antenna Installation Warning: To avoid hazardous RF radiation exposure, ensure the device
is switched off when installing or changing antennas. The device must only use Palo Alto
Networks approved antennas and accessories.
•Cellular Devices: The USB 2.0 port on the cellular device is used for maintenance only.
•International Statements and Information Pertaining to Radio Products
•Information on compliance to RF exposure guidelines: The Palo Alto Networks ION
1200 series devices are designed to comply with the following national and international
standards on human RF exposure, to ensure compliance with these RF exposure standards,
ION 1200 Hardware Reference 8©2022 Palo Alto Networks, Inc.

Before You Begin
the device must only be operated with Palo Alto Networks approved antennas and
accessories.
• US 47 Code of Federal Regulations Part 2
• American National Standards Institute (ANSI) / Institute of Electrical and Electronic
Engineers / IEEE C 95.1 (99)
• International Commission on Non-Ionizing Radiation Protection (ICNIRP) 98
• Ministry of Health (Canada) Safety Code 6, Limits on Human Exposure to Radio
Frequency Fields in the range from 3KHz to 300GHz
• Australia Radiation Protection Standard
•International Guidelines for Exposure to Radio Waves: The ION 1200 series includes a
radio transmitter and receiver. It is designed not to exceed the limits for exposure to RF
radiation specified in ICNIRP guidelines that were devised to include a substantial safety
margin to ensure the safety of all persons, regardless of age and health.
The World Health Organization has stated that current scientific information does not
indicate a need for special precautions for wireless devices. They also recommend that
further exposure reductions are possible by orienting antennas away from personnel or by
increasing the separation distance.
•Additional Information on RF Exposure:
• FCC Bulletin 56: Questions and Answers about Biological Effects and Potential Hazards
of Radio Frequency Electromagnetic Fields
• FCC Bulletin 65: Evaluating Compliance with the FCC guidelines for Human Exposure to
Radio Frequency Electromagnetic Fields
• FCC Bulletin 65C (01-01): Evaluating Compliance with the FCC guidelines for Human
Exposure to Radio Frequency Electromagnetic Fields: Additional Information for
Evaluating Compliance for Mobile and Portable Devices with FCC limits for Human
Exposure to Radio Frequency Emission
• World Health Organization Internal Commission on Non-Ionizing Radiation Protection at
this URL: www.who.int/emf
• United Kingdom, National Radiological Protection Board at this URL: www.nrpb.org.uk
• Cellular Telecommunications Association at this URL: www.ctia.org/
• The Mobile and Wireless Forum (MWF) at this URL: www.emfhealth.info/index.cfm
•National Statements and Information Pertaining to Radio Products
•US
•RF Exposure Warning: This equipment was evaluated to FCC radio frequency (RF)
exposure limits set forth for an uncontrolled environment. To comply with FCC exposure
limits, antennas for this product must be located at a distance of a minimum of 50cm
(19.7in) or more from all persons.
•Product Modification Warning: The radio contained in this product operates with
other devices in this frequency band and with other services operating within the radio
spectrum. Any changes or modifications to the product without approval from Palo
Alto Networks could void the user’s authority to operate the device. Such modifications
include the use of non-approved antennas, accessories, or amplifiers. The radio has been
ION 1200 Hardware Reference 9©2022 Palo Alto Networks, Inc.

Before You Begin
evaluated under FCC Bulletin OET 65C and found compliant to the requirements as set
forth in CFR 47 Sections 2.1091.
•Cellular Products: This device operates under the authority of a licensed radio service
under 47 Code of Federal Regulations Parts 22, 24, and 27.
•FCC Co-location: This product must not be co-located or operate in conjunction with
another radio.
•FCC Guidelines for Exposure to Radio Waves: The ION 1200 series includes a radio
transmitter and receiver. It is designed not to exceed the limits for exposure to RF
radiation specified in FCC Part 1.1310. The FCC guidelines are based on IEEE ANSI C
95.1 (92) and include a substantial safety margin to ensure the safety of all persons,
regardless of age and health. The device has been tested and found compliant with the
applicable regulations as part of the radio certification process. The US Food and Drug
Administration (FDA) has stated that current scientific information does not indicate
a need for special precautions for wireless devices. The FCC recommends that further
exposure reductions are possible [1] by orienting antennas away from personnel, [2] by
increasing the separation distance.
•Canada
•Industry Canada Radio Interference Statement: This device contains transmitter(s)/
receiver(s) that comply with Innovation, Science and Economic Development (ISED)
Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
This device may not cause interference.
This device must accept any interference, including interference that may cause
undesired operation of the device.
French Translation: L’émetteur/récepteur exempt de licence contenu dans le présent
appareil est conforme aux CNR d’Innovation, Sciences et Développement économique
Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée
aux deux conditions suivantes:L’appareil ne doit pas produire de brouillage.L’appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
•RF Exposure Warning: This equipment complies with ISED RF exposure limits set forth
for an uncontrolled environment. This equipment must be installed and operated with a
minimum distance of 50cm (19.7in) between personnel and the radio antennas.
•ISED Co-location: This product must not be co-located or operate in conjunction with
another radio.
•Industry Canada Guidelines for Exposure to Radio Waves: The ION 1200 series includes
a radio transmitter and receiver. It is designed not to exceed the limits for exposure to
RF radiation as referenced in Health Canada Safety Code 6. Those guidelines include a
substantial safety margin to ensure the safety of all persons, regardless of age and health.
Health Canada states that current scientific information does not indicate a need for
special precautions for wireless devices. Health Canada recommends that further
exposure reductions are possible [1] by orienting antennas away from personnel or [2] by
increasing the separation distance.
The systems are designed to be operated to avoid contact with the antennas by the user.
It is recommended to set the system in a location where the antennas can remain at
ION 1200 Hardware Reference 10 ©2022 Palo Alto Networks, Inc.

Before You Begin
least a minimum distance as specified from the user in accordance with the regulatory
guidelines which are designed to reduce the exposure to the user.
•EU
This equipment is intended to be used in all EU and EFTA countries. Outdoor use may be
restricted to certain frequencies and/or may require a license for operation. The use of
wireless devices in hazardous locations is limited to the constraints posed by the safety
directors of such environments. The use of a portable device may be restricted in some
locations.
The use of wireless devices in hospitals is restricted to the limits set forth by each hospital.
The use of software or firmware not supported/provided by the manufacturer may result in
the equipment being no longer compliant with the regulatory requirements.
•Australia and New Zealand
To ensure compliance with RF exposure standards, the system must only be operated with
Palo Alto Networks approved antennas and accessories.
To ensure compliance with exposure limits to radio frequency fields, the antenna must be
no closer than 50cm (19.7in) from personnel.
Radio communications devices are sometimes used for radio applications with commercial
or safety of life implications. Users of such applications are encouraged to have particular
regard to the suitability of operating under the Australian Radio communications Class
License for their radio communications need.
ION 1200 Hardware Reference 11 ©2022 Palo Alto Networks, Inc.

Before You Begin
ION 1200 Hardware Reference 12 ©2022 Palo Alto Networks, Inc.

ION 1200 Overview
Learn about the next generation SASE ION 1200 device.
>Overview ION 1200
>ION 1200 Hardware Specifications
>ION 1200 Front Panel
>ION 1200-C-NA/ROW Front Panel
>ION 1200-C-5G-WW Front Panel
>ION 1200 Back Panel
>ION 1200-C-NA/ROW Back Panel
>ION 1200-C-5G Back Panel
>ION 1200 Compliance Statement
>ION 1200-S Front Panel
>ION 1200-S-C-NA/ROW Front
Panel
>ION 1200-S-C5G-WW Front Panel
>ION 1200-S Back Panel
>ION 1200-S-C-NA/ROW Back Panel
>ION 1200-S-C-5G Back Panel
>ION 1200 LEDs
>ION 1200-S Compliance Statement
>Installation Kit Components
13

ION 1200 Overview
Overview ION 1200
Prisma SD-WAN ION 1200 is a next generation software defined enterprise branch device with
integrated 4G or 5G cellular network access and Layer 2 switching ports. The switching ports
increase the number of devices directly connected on Wireless Access Points (WAP).
With the introduction of ION 1200, you can accelerate your SASE deployment to branch offices
by leveraging 4G or 5G connectivity without installing additional hardware in the branch. Use the
4G or 5G network as the primary WAN connectivity to enable rapid deployment of ATMs or kiosk
systems or as a secondary backup link to improve the resilience of the branch WAN.
With the new ION 1200-S device, you can provide secure, access layer connectivity to endpoint
devices, through PoE++ capable switch ports.
The variants of the ION 1200 series are:
•ION 1200 for enterprise small branch.
•ION 1200-C-NA and ION 1200-C-ROW for small branch with integrated 4G LTE for North
America (NA) or Rest of the World (ROW).
•ION 1200-C-5G-WW for small branch with integrated 5G for world wide (WW).
•ION 1200-S for enterprise small branch with integrated Layer 2 switch ports.
•ION 1200-S-C-NA and ION 1200-S-C-ROW for small branch with integrated Layer 2 switch
ports and 4G LTE for North America (NA) or Rest of the World (ROW).
•ION 1200-S-C5G-WW for small branch with integrated Layer 2 switch ports and 5G for world
wide (WW).
•ION 1200: Enterprise small branch.
•ION 1200-C-NA and ION 1200-C-ROW
ION 1200-C-NA: Enterprise small branch with integrated 4G LTE for North America (NA).
ION 1200-C-ROW: Enterprise small branch with integrated 4G LTE for APAC and EMEA (Rest
of the World).
ION 1200 Hardware Reference 14 ©2022 Palo Alto Networks, Inc.

ION 1200 Overview
•ION 1200-C-5G-WW:
Enterprise small branch with integrated 5G for world wide (WW).
•ION 1200-S
Enterprise small branch device with integrated Layer 2 switch ports.
•ION 1200-S-C-NA and ION 1200-S-C-ROW
ION 1200-S-C-NA: Enterprise small branch with integrated Layer 2 switch ports and 4G LTE
for North America (NA).
ION 1200-S-C-ROW: Enterprise small branch with integrated Layer 2 switch ports and 4G LTE
for APAC and EMEA (Rest of the World).
•ION 1200-S-C5G-WW
Enterprise small branch with integrated Layer 2 switch ports and 5G for world wide (WW).
ION 1200 Hardware Reference 15 ©2022 Palo Alto Networks, Inc.

ION 1200 Overview
ION 1200 Hardware Specifications
Learn the hardware specifications of the following ION 1200 variants:
•ION 1200
•ION 1200-S
ION 1200 ION 1200-C-NA ION 1200-C-
ROW
ION 1200-C-5G-
WW
Description Enterprise small
branch
Enterprise small
branch with
integrated 4G
LTE for North
America
Enterprise small
branch with
integrated 4G
LTE for APAC
and EMEA
Enterprise small
branch with
integrated 5G
for world wide
Ports
Console Port 1 x RJ-45 1 x RJ-45 1 x RJ-45 1 x RJ-45
WAN/LAN
ports
4 x
10/100/1000
RJ-45
4 x 10/100/1000
RJ-45
4 x
10/100/1000
RJ-45
4 x
10/100/1000
RJ-45
USB 2 x Type-A 2 x Type-A 2 x Type-A 2 x Type-A
eMMC Storage 32GB 32GB 32GB 32GB
Encrypted IP
throughput
(measured
with 1400 byte
packets)
250Mbps 250Mbps 250Mbps 250Mbps
Memory 8GB 8GB 8GB 8GB
Type or Watts 25W Power
adapter
40W Power
adapter
40W Power
adapter
40W Power
adapter
Power Input AC 100–240 V,
50–60Hz
AC 100–240 V,
50–60Hz
AC 100–240 V,
50–60Hz
AC 100–240 V,
50–60Hz
Mechanical
System Cooling Fanless Fanless Fanless Fanless
Certifications
ION 1200 Hardware Reference 16 ©2022 Palo Alto Networks, Inc.

ION 1200 Overview
ION 1200 ION 1200-C-NA ION 1200-C-
ROW
ION 1200-C-5G-
WW
Certifications IEC 62368-1,
cTUVus, FCC,
CE B, RoHS
IEC 62368-1,
cTUVus, FCC, CE
B, RoHS
IEC 62368-1,
cTUVus, FCC,
CE B, RoHS
IEC 62368-1,
cTUVus, FCC,
CE B, RoHS
Environmental
Operating
temperature
(3000 m
altitude)
32ºF - 104ºF
(0ºC - 50ºC)
32ºF - 104ºF
(0ºC-50ºC)
32ºF - 104ºF
(0ºC-50ºC)
32ºF - 104ºF
(0ºC-50ºC)
Storage
temperature
-4ºF - 158ºF
(-20ºC - 70ºC)
-4ºF - 158ºF
(-20ºC - 70ºC)
-4ºF - 158ºF
(-20ºC - 70ºC)
-4ºF - 158ºF
(-20ºC - 70ºC)
Operating
humidity (non-
condensing)
10-90% 10-90% 10-90% 10-90%
Storage
humidity (non-
condensing)
10-90% 10-90% 10-90% 10-90%
Physical
Dimensions
(DxWxH)
6.42”x9.53”x1.73”(163mmx242mmx44mm)6.42”x9.53”x1.73”(163mmx242mmx44mm)6.42”x9.53”x1.73”(163mmx242mmx44mm)6.42”x9.53”x1.73”(163mmx242mmx44mm)
Weight (lbs) 3.69 3.75 3.75 3.75
Mount options Rack, Desktop,
Wall
Rack, Desktop,
Wall
Rack, Desktop,
Wall
Rack, Desktop,
Wall
Cellular specifications
SIM Slot Size Not Supported Nano (4FF) Nano (4FF) Nano (4FF)
Radio Main (TX/RX1)
AUX (RX2)
GNSS
Main (TX/RX1)
AUX (RX2)
GNSS
Main (TX1/RX1)
MIMO1(TX2/
RX2)
MIMO2 (RX3/
GNSS L5)
AUX (RX4/
GNSS L1)
ION 1200 Hardware Reference 17 ©2022 Palo Alto Networks, Inc.

ION 1200 Overview
ION 1200 ION 1200-C-NA ION 1200-C-
ROW
ION 1200-C-5G-
WW
Antenna
Terminal
Not Supported SMA (F) SMA (F) SMA (F)
GNSS/GPS Not Supported GPS Standalone GPS Standalone GPS Standalone
Supported RF
bands
Not Supported LTE: B2, B4, B5,
B7, B12, B13,
B14, B25, B26,
B41, B42, B43,
B48, B66, B71
3G: B2, B4, B5
LTE: B1, B3, B7,
B8, B20, B28,
B32, B38, B40,
B41, B42, B43
3G: B1, B5, B8
5G NR
Sub-6GHz (FR1):
n1, n2, n3, n5,
n28, n41, n66,
n71, n77, n78,
n79
LTE: B1, B2, B3,
B4, B5, B7, B8,
B12, B13, B14,
B17, B18, B19,
B20, B25, B26,
B28, B29, B30,
B32, B34, B38,
B39, B40, B41,
B42, B46, B48,
B66, B71
3G: B1, B2, B3,
B4, B5, B6, B8,
B9, B19
Cellular Carrier
Certification
Not Supported • AT&T
• Verizon
• PTCRB
• T-Mobile
• GCF • AT&T
• PTCRB
• T-Mobile
• Verizon
• GCF
Learn the new hardware specifications of the ION 1200-S series.
ION 1200-S ION 1200-S-C-NA ION 1200-S-C-
ROW
ION 1200-S-
C5G-WW
Description Enterprise small
branch device
with L2 switch
ports.
Enterprise small
branch device
with integrated
with L2 switch
ports and 4G
LTE for North
America.
Enterprise small
branch device
with integrated
with L2 switch
ports and 4G
LTE for APAC
and EMEA.
Enterprise small
branch device
with integrated
with L2 switch
ports and 5G for
world wide.
ION 1200 Hardware Reference 18 ©2022 Palo Alto Networks, Inc.

ION 1200 Overview
ION 1200-S ION 1200-S-C-NA ION 1200-S-C-
ROW
ION 1200-S-
C5G-WW
Ports
Console Port 1 x RJ-45
WAN/LAN
ports
6 x 10/100/1000 RJ-45, 2 x RJ-45/SFP Combo ports
L2 Switch Ports 6xRJ-45 LAN, 1Gbps
• 4 x PoE (802.3af) 15.4 W maximum
• 3 x PoE+ (802.3at) 30 W maximum
• 1 x PoE++ (802.3bt) 60 W maximum for type 3 PSEs.
L2 ports PoE 90W PoE budget, 4xPoE ports, 60W max/port
USB 3.0 2 x Type-A
ByPass Pair 2xRJ-45 (1pair)
eMMC Storage 128GB
Encrypted IP
throughput
(measured
with 600 byte
packets)
250Mbps
Memory 8GB
Type or Watts 150W Power adapter
HTTP
throughput
(Mbps)
<>
Power Input AC 100–240 V, 50–60Hz
Mechanical
System Cooling Fanless
Certifications
Certifications IEC 62368-1,
cTUVus, FCC,
CE B, RoHS,
FIPS
IEC 62368-1,
cTUVus, FCC, CE
B, RoHS, FIPS
IEC 62368-1,
cTUVus, FCC,
CE B, RoHS,
FIPS
IEC 62368-1,
cTUVus, FCC,
CE B, RoHS,
FIPS
ION 1200 Hardware Reference 19 ©2022 Palo Alto Networks, Inc.

ION 1200 Overview
ION 1200-S ION 1200-S-C-NA ION 1200-S-C-
ROW
ION 1200-S-
C5G-WW
Environmental
Operating
temperature
(3000 m
altitude)
32ºF - 113ºF
(0ºC - 45ºC)
32ºF - 113ºF
(0ºC-45ºC)
32ºF - 113ºF
(0ºC-45ºC)
32ºF - 113ºF
(0ºC-45ºC)
Storage
temperature
-4ºF - 158ºF
(-20ºC - 70ºC)
-4ºF - 158ºF
(-20ºC - 70ºC)
-4ºF - 158ºF
(-20ºC - 70ºC)
-4ºF - 158ºF
(-20ºC - 70ºC)
Operating
humidity (non-
condensing)
10-90% 10-90% 10-90% 10-90%
Storage
humidity (non-
condensing)
10-90% 10-90% 10-90% 10-90%
Physical
Dimensions
(DxWxH)
9” x 13” x 1.73” (228.6mm x 330.2mm x 43.9mm)
Weight (lbs) 7.79 7.85 7.85 7.85
Mount options Rack, Desktop Rack, Desktop Rack, Desktop Rack, Desktop
Cellular specifications
SIM Slot Size Not Supported Nano (4FF) Nano (4FF) Nano (4FF)
Radio Not Supported Main (TX/RX1)
AUX (RX2)
GNSS
Main (TX/RX1)
AUX (RX2)
GNSS
Main (TX1/RX1)
MIMO1(TX2/
RX2)
MIMO2 (RX3/
GNSS L5)
AUX (RX4/
GNSS L1)
Antenna
Terminal
Not Supported SMA (F) SMA (F) SMA (F)
GNSS/GPS Not Supported GPS Standalone GPS Standalone GPS Standalone
ION 1200 Hardware Reference 20 ©2022 Palo Alto Networks, Inc.
Other manuals for ION 1200 Series
1
This manual suits for next models
8
Table of contents
Popular Network Router manuals by other brands

Asoka
Asoka Pluglink PL9950-BBR user guide

SMC Networks
SMC Networks EZ Switch SMC-EZ1024DT user guide

D-Link
D-Link DSL-504G Quick installation guide

Silicon Graphics
Silicon Graphics Altix ICE 8000 Series Quick reference guide

Patton electronics
Patton electronics IM 1/I user manual

Mercury
Mercury Broadband Router user manual