MIW-POWER-PRO-PFP INSTALLATION INSTRUCTIONS
STEP 1:
Select a location close to the equipment. In the case of a at panel
display, the recommended location is one that is behind the device
and hidden from view once the Plasma TV is mounted. Cut a 4”
wide by 3 3/4” high hole in the wall for the outlet box.
STEP 2:
Run the building wire (e.g. Romex) through a rear opening in
the outlet box (not included). No more than 1” of wire sheath
should extend into the outlet box. 3” of wire should be able to
extend beyond the opening of the outlet box. Install the outlet
box in the hole.
STEP 3:
Strip building wire. Using the included wire nuts, rst connect
the ground wires - green insulated on the MlW-Power-Pro-PFP
and bare copper on the building wire. Then connect the neutral
wires (white), then the hot wires (black).
STEP 4:
Neatly fold the AC wires as you install the MIW-Power-Pro-PFP
in the outlet box and secure with the included screws.
STEP 5:
Turn the power on to the circuit. The blue Power indicator
should light up, indicating the outlet is ready for use.
NOTES:
In the event of a hazardous voltage situation, the red Unsafe
Voltage indicator will light up until the voltage returns to a safe
level.
1
(Outlet boxes
not included)
INS00840 REV E 02/10
CAUTION:
Only for use with 15 Amp circuits utilizing a minimum of 14 AWG.
Make sure the circuit is not live before installation. If you are unsure how
to perform this task, please contact an electrician.
Signal Protection Module Usage:
Panamax In-Wall signal protection modules (sold separately),
while not necessary for surge protection in the Max In-Wall
Power-Pro-PFP, may be used to provide a clean looking interface
for the signal lines. When used in the proper manner the modules
also provide total protection to the connected equipment.
2
MIW-POWER-PRO-PFP SPECIFICATIONS
AC Circuit
AC Outlets, Total: ..................................................2
Line Voltage: .....................................120V, 50/60Hz
Total Current Capacity: .....................................15A
Voltage Protection Rating
(UL1449 3rd Edition, 3,000A)...........................500V
Protection Modes: .............................L-N, L-G, N-G
Energy Dissipation: ................................546 Joules
Peak Impulse Current: ...............................32,500A
Catastrophic Surge Circuit: ...............................Yes
Thermal Fusing: ................................................Yes
Over-voltage shutoff: ....................142VAC ± 5VAC
Power Outlet Faceplate
AC Connectors: ............................2 NEMA 5-15
Noise Filtration: ......................................Level 1
Signal Line Protection: Not Included / Modules
Sold
Separately
CONTENTS CONTACTING PFPOWER
PFPower
1690 Corporate Circle
Petaluma, CA 94954
Phone - 707-283-5900 or 800-472-5555
Fax - 707-283-5901
Web - www.panamax.com
Customer Relations
7:30 AM – 4:30 PM, M-F Pacic Time
Email - [email protected]
One MAX In-Wall
power outlet
enclosure
Specications are subject to changes due to product upgrades and improvements.
(4) Mounting Screws
(3) Wire Nuts
Included Installation Accessories:
CAUTION – Do not install this device if
there is not at least 10 meters (30 feet) or
more of wire between the electrical outlet
and electrical service panel.

Other Panamax Enclosure manuals

Panamax MIW-POWERKIT-TL User manual

Panamax

Panamax MIW-POWERKIT-TL User manual

Panamax MIW-SURGE User manual

Panamax

Panamax MIW-SURGE User manual

Panamax MIW-POWERKIT-MOB User manual

Panamax

Panamax MIW-POWERKIT-MOB User manual

Panamax MIW-POWERKIT-TL User manual

Panamax

Panamax MIW-POWERKIT-TL User manual

Popular Enclosure manuals by other brands

Thermaltake VP4000 Series user manual

Thermaltake

Thermaltake VP4000 Series user manual

Eaton 93PM IAC-T Series Installation and operation manual

Eaton

Eaton 93PM IAC-T Series Installation and operation manual

Connectland X-Rev Storage Center user manual

Connectland

Connectland X-Rev Storage Center user manual

CopperOptics PairGain PG-FLEX PLUS PRL-770 List 2E manual

CopperOptics

CopperOptics PairGain PG-FLEX PLUS PRL-770 List 2E manual

Netstor NS780S-G3 user manual

Netstor

Netstor NS780S-G3 user manual

Newer Technology miniStack v2 Owner's manual & assembly guide

Newer Technology

Newer Technology miniStack v2 Owner's manual & assembly guide

Origen ae S8 user guide

Origen ae

Origen ae S8 user guide

Altronix Trove T1RAL13F8P8 installation manual

Altronix

Altronix Trove T1RAL13F8P8 installation manual

Rosewill RX30 User manual & installation guide

Rosewill

Rosewill RX30 User manual & installation guide

Vantec NexStar TX installation guide

Vantec

Vantec NexStar TX installation guide

Extron electronics HSA 822M user manual

Extron electronics

Extron electronics HSA 822M user manual

Geberit IDO Showerama 8-3 Operating and maintenance instructions

Geberit

Geberit IDO Showerama 8-3 Operating and maintenance instructions

Sharkoon BD28 quick start guide

Sharkoon

Sharkoon BD28 quick start guide

ABB ACH580-01 PxR R3 instructions

ABB

ABB ACH580-01 PxR R3 instructions

Icy Box IB-HUB1703-QC3 Quick installation guide

Icy Box

Icy Box IB-HUB1703-QC3 Quick installation guide

Lindy 43288 user manual

Lindy

Lindy 43288 user manual

Martin Audio W8LD Specification sheet

Martin Audio

Martin Audio W8LD Specification sheet

Allen-Bradley 1336 PLUS II instruction manual

Allen-Bradley

Allen-Bradley 1336 PLUS II instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.