manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. P&E
  6. •
  7. Security Sensor
  8. •
  9. P&E PE-7208P Installation and operating instructions

P&E PE-7208P Installation and operating instructions

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

User Manual / Installation Guide
1
PE-7208P – Wireless PIR Wall Mounting Detector / Pet Immunity
User Manual
PE-7208P is wireless PIR intrusion detector with pet immunity, it adopts PIR technology intruder detector
designed to detect human body movement in a protected area, digital processing ensure a high immunity to false
alarms and outstanding stability, it uses a sophisticated radio communication protocol with a high level of data
safety, the detector make auto testing and report its status to the system for full supervision regularly, built-in
tamper switch trigger alarm if there is any attempt to tamper with the detector, auto testing mode make testing in
ease.
Features:
1. anti-white light with spherical lens and sealed optical design
2. adpots self-designed MASK chip with DMT technology
3. reliable detection performance with dual passive PIR technology
4. wireless detection distance: 9m@25℃/ detection angle: 90°
5. wireless emitting distance is 120 ~ 150 meter (in open area)
6. pet immunity under 25kgs
7. wireless emitting frequency is 433MHz / 868MHz
8. working voltage is 3.0V DC (CR123A 3.0V Lithium Battery)
9. Anti-EMI >30V/m(30MHz~1GHz) /Anti-White Light >8000LUX
10. installation height 1.8 ~ 2.5 meter (6 ~ 8 feet) / single-sided corner mount at 45°to wall
11. consumption current is 9uA(static)/20mA(alarm)
12. alarm indication is LED light flash for 2 seconds
13. operation temperature is -10℃to +50℃(14°F to 122°F)
14. storage temperature is -20℃to +60℃(-4°F to 140°F)
15. dimension is 95*64*49mm / ivory white color
Installation:
Installation Guide for Pet Immunity:
Don’t face cold or
hear source Don’t face the
sunshine directly Don’t install near
electric cables Don’t face the
metal wall
Don’t install on a
unstable base
side view wall mounting wide angle lens view
Top part of detection area
is non pet-immunity area Don’t face the detector to the place
that pets can climb up dierctly Pet Immunity ≤25kgs Pet immunity Installation
height is 2.2 – 2.4 meters
User Manual / Installation Guide
2
Note: can choose underside installation, 45° wall installation and bracket installation, bracket installation is the
most convenient way.
DIP Switch Function:
Choose 3 different pulse counting as below:
1-Pulse: detector make the alarm when detected 1 pulse
2-Pulse: detector make the alarm when detected 2 pulse
3-Pulse: detector make the alarm when detected 3 pulse
more pulse counting, the lower performance for sensitivity of capture, but
more pulse counts can reduce fales alarms.
Setting 3 different working modes as below:
Testing Mode: sending the wireless alarm signal when detector had
been triggered, no time interval between two signal sending.
Normal/Saving Mode: every 2.5mins detect one time, every 65mins
sending one wireless monitoring signal to report the status of detector and
battery.
Coding Mode: when detector is on working status, inverse it to send an
address code to alarm control panel
CodingMethod: (betweendetectorandwirelessalarmcontrolpanel)
1. detector on normal mode, place the lithium battery and LED light will flash
few seconds; alarm control panel on wireless coding mode (please refer
alarm control panel user manual), press tamper switch to sending the
wireless signal to alarm control panel, if alarm control panel make the
corresponding indicate sound, it means match code successfully.
2. alarm control panel on manual coding mode, enter the 9 digit address code
to match, this will be a higher probability of coding success.
Change Battery:
when detector sending the wireless signal, LED light flash, it means the low
battery situation, and detector also can sending the low battery alarm indication
to alarm control panel. (CR123A3.0V Lithium Battery)
Walk Testing on Cover Area:
1. detector on testing mode, pulse counting set as 1, 2 or 3;
2. horizontal movement which triggers detector alarming at the remote of the
detection coverage at the speed of 0.75m/s, the LED light indicator will
flash few seconds;
3. testing in different direction to confirm the two boundaries of the coverage,
ensure the detector is appointed to the central desired area;
4. the centre of detection area should not be towards vertical incline, if can
not obtain an ideal detection area, please adjust the vertical angle to
ensure direction for detector neither high or low;
5. once detection angle is adjusted, walk testing must be performed again;
6. please set detector to normal mode after finished walk testing.
DIP Switch 1 & 2 setting
corresponding working modes:
DIP Switch 3 & 4 setting
corresponding working modes: