3
8775-A2-GZ40-00 March 1998
Cables You Need
The following customer-provided cables are used with this product.
For the network connection:
Plug-ended Telco 50-pin cable for connection from the Hotwire 8600 DSLAM
LINE port or one of the Hotwire 8800 DSLAM LINES ports to the Main
Distribution Frame (MDF) or other demarcation point.
For the DTE connection, one of the following:
100-pin plug to four DB15 (X.21)
100-pin plug to four DB25 (EIA-530A)
100-pin plug to four DB37 (RS-449)
100-pin plug to four MS34 (V.35)
See
Technical Specifications
on page 2 for part numbers of the DTE cables. For
more information refer to Appendix D,
Cables and Pin Assignments
, in the User’s
Guide.
Installing DSL Cards
Use a small- to medium-size flat-blade screwdriver to install the 8775 Termination
Unit.
When using a . . . Install the 8775 Termination Unit in . . .
Hotwire 8600 DSLAM base
chassis Slot 2 or 3 (Slot 1 of the Hotwire 8600 DSLAM base
chassis must contain a Management Communications
Controller (MCC) card.)
Hotwire 8600 DSLAM
expansion chassis Slot 1, 2, or 3
Hotwire 8800 DSLAM
chassis Any one of the first 18 slots (i.e., Slot 1 through 18)
An 8775 Termination Unit can be installed, removed, and replaced from a Hotwire
DSLAM chassis without disrupting service to the other cards in the chassis.
NOTE:
When installing the 8775 Termination Unit, you need to remove the filler plate
before proceeding.
Do not discard unused filler plates. Each slot in the chassis must contain a
circuit card or a filler plate. Store all unused filler plates in a safe place. You
may need to use the filler plates to cover open slots in the chassis at a later
time.