PCB Piezotronics IMI SENSORS 684a16 User manual

Model 684a16
6 Channel BNC Enclosure
Installation and Operating Manual
For assistance with the operation of this product,
contact PCB Piezotronics, Inc.
Toll-free: 800-959-4464
24-hour SensorLine: 716-684-0001
Fax: 716-684-3823
E-mail: [email protected]
Web: www.imi-sensors.com

Manual 21354 Rev E
ECN 50523
Repair and Maintenance
PCB guarantees Total Customer Satisfaction through its
“Lifetime Warranty Plus” on all Platinum Stock Products
sold by PCB and through its limited warranties on all other
PCB Stock, Standard and Special products. Due to the
sophisticated nature of our sensors and associated
instrumentation, field servicing and repair is not
recommended and, if attempted, will void the factory
warranty.
Beyond routine calibration and battery replacements
where applicable, our products require no user
maintenance. Clean electrical connectors, housings, and
mounting surfaces with solutions and techniques that will
not harm the material of construction. Observe caution
when using liquids near devices that are not hermetically
sealed. Such devices should only be wiped with a
dampened cloth—never saturated or submerged.
In the event that equipment becomes damaged or ceases
to operate, our Application Engineers are here to support
your troubleshooting efforts 24 hours a day, 7 days a
week. Call or email with model and serial number as well
as a brief description of the problem.
Calibration
Routine calibration of sensors and associated
instrumentation is necessary to maintain measurement
accuracy. We recommend calibrating on an annual basis,
after exposure to any extreme environmental influence,
or prior to any critical test.
PCB Piezotronics is an ISO-9001 certified company whose
calibration services are accredited by A2LA to ISO/IEC
17025, with full traceability to SI through N.I.S.T. In
addition to our standard calibration services, we also offer
specialized tests, including: sensitivity at elevated or
cryogenic temperatures, phase response, extended high
or low frequency response, extended range, leak testing,
hydrostatic pressure testing, and others. For more
information, contact your local PCB Piezotronics
distributor, sales representative, or factory customer
service representative.
Returning Equipment
If factory repair is required, our representatives will
provide you with a Return Material Authorization (RMA)
number, which we use to reference any information you
have already provided and expedite the repair process.
This number should be clearly marked on the outside of
all returned package(s) and on any packing list(s)
accompanying the shipment.
Contact Information
PCB Piezotronics, Inc.
3425 Walden Ave.
Depew, NY14043 USA
Toll-free: (800) 828-8840
24-hour SensorLine: (716) 684-0001
Repair inquiries: rma@pcb.com
For a complete list of distributors, global offices and sales
representatives, visit our website, www.pcb.com.
Safety Considerations
This product is intended for use by qualified personnel
who recognize shock hazards and are familiar with the
precautions required to avoid injury. While our equipment
is designed with user safety in mind, the protection
provided by the equipment may be impaired if equipment
is used in a manner not specified by this manual.
Discontinue use and contact our 24-Hour Sensorline if:
Assistance is needed to safely operate equipment
Damage is visible or suspected
Equipment fails or malfunctions
For complete equipment ratings, refer to the enclosed
specification sheet for your product.
Definition of Terms and Symbols
The following symbols may be used in this manual:
DANGER
Indicates an immediate hazardous
situation, which, if not avoided, may
result in death or serious injury.

Manual 21354 Rev E
ECN 50523
CAUTION
Refers to hazards that could damage
the instrument.
NOTE
Indicates tips, recommendations and
important information. The notes
simplify processes and contain
additional information on particular
operating steps.
The following symbols may be found on the equipment
described in this manual:
This symbol on the unit indicates that
high voltage may be present. Use
standard safety precautions to avoid
personal contact with this voltage.
This symbol on the unit indicates that
the user should refer to the operating
instructions located in the manual.
This symbol indicates safety, earth
ground.

Manual 21354 Rev E
ECN 50523
PCB工业监视和测量设备 - 中国RoHS2公布表
PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table
部件名称
有害物质
铅(Pb)
汞
(Hg)
镉
(Cd)
六价铬(Cr(VI))
多溴联苯 (PBB)
多溴二苯醚(PBDE)
住房
O
O
O
O
O
O
PCB板
X
O
O
O
O
O
电气连接器
O
O
O
O
O
O
压电晶体
X
O
O
O
O
O
环氧
O
O
O
O
O
O
铁氟龙
O
O
O
O
O
O
电子
O
O
O
O
O
O
厚膜基板
O
O
X
O
O
O
电线
O
O
O
O
O
O
电缆
X
O
O
O
O
O
塑料
O
O
O
O
O
O
焊接
X
O
O
O
O
O
铜合金/黄铜
X
O
O
O
O
O
本表格依据 SJ/T 11364 的规定编制。
O:表示该有害物质在该部件所有均质材料中的含量均在 GB/T 26572 规定的限量要求以下。
X:表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572 规定的限量要求。
铅是欧洲RoHS指令2011/65/ EU附件三和附件四目前由于允许的豁免。
CHINA RoHS COMPLIANCE

Manual 21354 Rev E
ECN 50523
Component Name
Hazardous Substances
Lead (Pb)
Mercury (Hg)
Cadmium (Cd)
Chromium VI
Compounds
(Cr(VI))
Polybrominated
Biphenyls (PBB)
Polybrominated
Diphenyl Ethers
(PBDE)
Housing
O
O
O
O
O
O
PCB Board
X
O
O
O
O
O
Electrical Connectors
O
O
O
O
O
O
Piezoelectric Crystals
X
O
O
O
O
O
Epoxy
O
O
O
O
O
O
Teflon
O
O
O
O
O
O
Electronics
O
O
O
O
O
O
Thick Film Substrate
O
O
X
O
O
O
Wires
O
O
O
O
O
O
Cables
X
O
O
O
O
O
Plastic
O
O
O
O
O
O
Solder
X
O
O
O
O
O
Copper Alloy/Brass
X
O
O
O
O
O
This table is prepared in accordance with the provisions of SJ/T 11364.
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit
requirement of GB/T 26572.
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit
requirement of GB/T 26572.
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU.

SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING
Models 684A1/684A4 Panel Meter Enclosures
Operating Guide with Enclosed Warranty Information
3425 Walden Avenue, Depew, New York 14043-2495
Phone (716) 684-0003
Fax (716) 684-3823
Toll Free Line 1-800-959-4IMI
MANUAL NUMBER: 20810
MANUAL REVISION: NR

PAGE 2
SENSORS AND INSTRUME
NTATION FOR MACHINE
CONDITION MONITORING
Table of Contents
Introduction………………………………………………………………………………………. Page 3
General Features
Specifications……………………………………………………………………………………. Page 3
Installation and Wiring………..………………………………………………………………… Page 4
Terminal Block Diagram…….………………………………………………………………….. Page 5
Dimension Drawing……...……………………………………………………………………… Page 6
ESD Sensitivity…………..……………………………………………………………………… Page 7
Ordering Information . .………………………………………………………………………… Page 8
Warranty/Servicing
Warranty, Service & Return Procedure........................................................................... Page 9
Customer Service........................................................................................................... Page 10

PAGE 3
SENSORS AND INSTRUME
NTATION FOR MACHINE
CONDITION MONITORING
Introduction
Models 684A1 and 684A4 Enclosures are designed to accept IMI Sensor’s 683A Series Panel Meter/Controllers.
Internal screw type terminal blocks are incorporated for easy interface between the Sensor, Panel Meter, and
Process Equipment. Models 684A1 and 684A4 utilize NEMA 4X (IP66) enclosures.
General Features
Enclosure has been machined to readily accept IMI Sensor’s model 683A Series Panel
Meters/Controllers.
Easy installation of Enclosure with supplied mounting accessory kit.
Screw terminal blocks provide for fast and reliable installation of wiring.
Different Panel Meters/Controllers can be mixed within one Enclosure.
Panel Meter/Controller comes factory installed and wired to its respective terminal blocks.
Enclosure is rated NEMA 4X (IP66)
Specifications
Channels: ...... 1 to 8 (User defined)
Terminal Strip Connectors: …… Input, Output, Power, Raw Vibration, SP1, SP2, and Retransmit.
BNC Jacks: …… Raw Vibration
Terminal Strips: …… 0.315”(8mm) Two Screw
Wire Size: …… 12 to 24 AWG (3.31 to 0.511 mm2)
Cord Grips: …… 1-PGME13, 5 to 40 PGME07 (depending on number of channels)
Enclosure Type: …… NEMA4X (IP66)
Dimensions (HxWxD): …… 16x14x8 in. (406 x 356 x 203 mm)
Dimensions (HxWxD) w/Meter, Grips, BNC: …… 17.4 x 14.6 x 8.5 in. (442 x 371 x 216 mm)
Weight: …… 10 lbs (4.5 kg)
Weight w/Meter, Grips, BNC: …… 23 lbs (10.5kg)
Panel Cutout (HxW): …… 1.715x3.615 in. (43.6x91.8mm)
BNC Cutout: …… 0.375 in. Dia. (9.5mm Dia.)

PAGE 4
SENSORS AND INSTRUME
NTATION FOR MACHINE
CONDITION MONITORING
Installation and Wiring
The 684A1/684A4 Enclosure is designed for use in conjunction with the Series 683A Panel Meter/Controller. The
Enclosure can be located near the machine that needs monitoring. Depending on the Enclosure’s configuration,
up to 8 sensors can be connected to the internal terminal blocks for interface to the Panel Meters/Controllers. The
terminal blocks also provide for output connections including Raw Vibration, 4-20mA Retransmit, and Alarm/Alert
Relays.
Establish an easily accessible location for installation and keep in mind where the cabling will be oriented. Once
the unit has been mounted, begin making appropriate connections for the interface cables.
All user connections are made to the terminal blocks (Fig.1) attached to the inside rear panels of the unit through
cord grips located on the bottom of the enclosure. The larges cord grip on the Enclosure should be used for
power connection, all other cord grips are used for sensor and signal interface.
Observe the labels on the terminal blocks when making connections. These labels identify the Panel
Meter/Controller interface where #1 is the TOP ROW LEFT METER, #2 is the TOP ROW RIGHT METER, #3 is
the SECOND ROW FROM TOP LEFT METER, and so on. Each Sensor Input has three connections, which are
made on the terminal strip; one for the signal/power (typically red wire, +), another for ground (typically black
wire), and the third is for the shield (typically a drain wire, SHIELD GND).
Panel Meter/Controller Power is connected to the respective terminal block located in the lower middle position.
Line, Neutral, and Earth Ground are connected to this block. Earth Ground should also be connected to the spade
lugs located on the two bottom screws that hold the terminal block mounting bracket.
The output connections from the terminal blocks consist of Raw Vibration, 4-20mA Retransmit, Alert (typically
SP1) and Alarm (typically SP2) Relays. All of these connections should go to process control/monitoring
equipment, additional signal conditioners, and machine diagnostic tools.
To install the wires, unscrew the terminal block so that enough room exists to insert a wire stripped of its
insulation. Insure that no bare wire is exposed and tighten the screw on the terminal block to hold the wire in
place.
To install Earth Ground to the spade lugs, remove the lugs by first unscrewing the terminal block mounting
bracket. Insert the Earth Ground wire into the lug and crimp using a crimping tool or a set of pliers. Reinstall the
lug to its original location. Note that all terminal block mounting bracket screws do not need to be removed during
Earth Ground installation. It is recommended that only the screws holding the lugs to the bracket be removed.
Regardless of ordered options, all Enclosures come equipped to electrically accommodate eight meters.
Therefore, some terminal blocks may be unused.
WARNING
AC and DC input signals and power supply voltages can be hazardous. DO NOT
connect live wires to screw terminal plugs, and DO NOT insert, remove, or handle screw
terminal plugs with live wires connected.

PAGE 5
SENSORS AND INSTRUME
NTATION FOR MACHINE
CONDITION MONITORING
Terminal Block Diagram
Figure 1

PAGE 6
SENSORS AND INSTRUME
NTATION FOR MACHINE
CONDITION MONITORING
Dimension Drawing
Figure 2
Model 684A18 Shown

PAGE 7
SENSORS AND INSTRUME
NTATION FOR MACHINE
CONDITION MONITORING
Warning 1 –ESD sensitivity
The power supply/signal conditioner should not be opened by anyone other than qualified service
personnel. This product is intended for use by qualified personnel who recognize shock hazards and are familiar
with the safety precautions required to avoid injury.
Warning 2 –ESD sensitivity
This equipment is designed with user safety in mind; however, the protection provided by the equipment may be
impaired if the equipment is used in a manner not specified by PCB Piezotronics, Inc.
Caution 1 –ESD sensitivity
Cables can kill your equipment. High voltage electrostatic discharge (ESD) can damage electrical devices.
Similar to a capacitor, a cable can hold a charge caused by triboelectric transfer, such as that which occurs in the
following:
Laying on and moving across a rug,
Any movement through air,
The action of rolling out a cable, and/or
Contact with a non-grounded person.
The PCB solution for product safety:
Connect the cables only with the AC power off.
Temporarily “short”the end of the cable before attaching it to any signal input or output.
Caution 2 –ESD sensitivity
ESD considerations should be made prior to performing any internal adjustments on the equipment. Any
piece of electronic equipment is vulnerable to ESD when opened for adjustments. Internal adjustments should
therefore be done ONLY at an ESD-safe work area. Many products have ESD protection, but the level of
protection may be exceeded by extremely high voltage.

PAGE 8
SENSORS AND INSTRUME
NTATION FOR MACHINE
CONDITION MONITORING
Ordering Information
IMI Part Number: 684A 0 1
Basic Model Number
684A
Enclosure Type
1 8x14x16 in. with BNC Holes
4 8x14x16 in. without BNC Holes
Number of Channels
1 One Panel Meter Cutout
2 Two Panel Meter Cutouts
3 Three Panel Meter Cutouts
4 Four Panel Meter Cutouts
5 Five Panel Meter Cutouts
6 Six Panel Meter Cutouts
7 Seven Panel Meter Cutouts
8 Eight Panel Meter Cutouts
Notes:
1) When only 1 meter is ordered, 6 cord grips are installed (1 Power, 5 Signal). Blanks will occupy 35 holes.
2) When 2 meters are ordered, 11cord grips are installed (1 Power, 10 Signal). Blanks will occupy 30 holes.
3) When 3 meters are ordered, 16 cord grips are installed (1 Power, 15 Signal). Blanks will occupy 25 holes.
4) When 4 meters are ordered, 21 cord grips are installed (1 Power, 20 Signal). Blanks will occupy 20 holes.
5) When 5 meters are ordered, 26 cord grips are installed (1 Power, 25 Signal). Blanks will occupy 15 holes.
6) When 6 meters are ordered, 31 cord grips are installed (1 Power, 30 Signal). Blanks will occupy 10 holes.
7) When 7 meters are ordered, 36 cord grips are installed (1 Power, 35 Signal). Blanks will occupy 5 holes.
8) When 8 meters are ordered, all cord grips are installed (1 Power, 40 Signal).
9) When a Model 683A0XXXXX Series Panel Meter is installed into a Model 684A1X Enclosure the BNC
hole will be populated with a Blank.
10) When a Model 683A1XXXXX Series Panel Meter is installed into a Model 684A1X Enclosure the BNC
hole will be populated with an off-ground BNC Jack.
11) All Enclosures come equipped with the correct number of terminal blocks and cord grip holes to
accommodate 8 Meters.
Example:
Part Number: 684A02
6x8x10 Enclosure with 2 Meter/Controller cutouts and 2 BNC holes. One cord grip installed for Power cabling and
10 cord grips installed for Signal cabling. Five remaining cord grip holes are occupied by blanks

PAGE 9
SENSORS AND INSTRUME
NTATION FOR MACHINE
CONDITION MONITORING
Warranty
IMI instrumentation is warranted against defective material and workmanship for 1 year unless otherwise
expressly specified. Damage to instruments caused by incorrect power or misapplication, is not covered by
warranty. If there are any questions regarding power, intended application, or general usage, please consult with
your local sales contact or distributor. Batteries and other expendable hardware items are not covered by
warranty.
Service
Because of the sophisticated nature of IMI instrumentation, field repair is typically NOT recommended and may
void any warranty. If factory service is required, return the instrumentation according to the “Return Procedure”
stated below. A repair and/or replacement quotation will be provided prior to servicing at no charge. Before
returning the unit, please consult a factory IMI applications engineer concerning the situation as certain problems
can often be corrected with simple on-site procedures.
Return procedure
To expedite returned instrumentation, contact a factory IMI applications engineer for a RETURN MATERIAL
AUTHORIZATION (RMA) NUMBER. Please have information available such as model and serial number. Also,
to insure efficient service, provide a written description of the symptoms and problems with the equipment to a
local sales representative or distributor, or contact IMI if none are located in your area.
Customers outside the U.S. should consult their local IMI distributor for information on returning equipment. For
exceptions, please contact the International Sales department at IMI to request shipping instructions and an RMA.
For assistance, please call (716) 684-0003, or fax us at (716) 684-3823. You may also receive assistance via e-
mail at imi@pcb.com or visit our web site at www.pcb.com.

PAGE 10
SENSORS AND INSTRUME
NTATION FOR MACHINE
CONDITION MONITORING
Customer Service
IMI, a division of PCB Piezotronics, guarantees Total Customer Satisfaction. If, at any time, for any reason, you
are not completely satisfied with any IMI product, IMI will repair, replace, or exchange it at no charge. You may
also choose, within the warranty period, to have your purchase price refunded.
IMI offers to all customers, at no charge, 24-hour phone support. This service makes product or application
support available to our customers, day or night, seven days a week. When unforeseen problems or emergency
situations arise, call the IMI Hot Line at (716) 684-0003, and an application specialist will assist you.
3425 Walden Avenue, Depew, NY 14043-2495
Phone: (716) 684-0003
USA Fax: (716) 684-3823
INTL Fax: (716) 684-4703
ICP®is a registered trademark of PCB Group, Incorporated,
which uniquely identifies PCB sensors that incorporate built-in microelectronics.

Model Number
684A16 ENCLOSURE WITH DIN RAILS Revision: A
ECN #: 46438
Performanc
e
ENGLISH S
I
Channels(Max) 24 24
Environmenta
l
Enclosure Rating Nema 4X IP66
Physica
l
Cable Input(36) PGME07 PGME07
Cable Output(1) PGME13 PGME13
Housing Material Fiberglass Fiberglass
Size (Height x Width x Depth) 8.47 in x 14.55 in x 16.95 in 215.1 mm x 369.6 mm x 430.5 mm
Weight(No Barriers) 15 lb 6.8 kg
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP®is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
Entered: LK Engineer: BAM Sales: M
C
Approved: BAM Spec Number:
Date: 2/3/2017 Date: 2/3/2017 Date: 2/3/2017 Date: 2/3/2017 22620
3425 Walden Avenue, Depew, NY 14043
Phone: 800-959-4464
Fax: 716-684-3823
E-Mail: [email protected]

Table of contents
Other PCB Piezotronics Enclosure manuals

PCB Piezotronics
PCB Piezotronics IMI SENSORS PCB-691A50/04 User manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 682A00 User manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 691A50/02 User manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 691A50/04 User manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS PCB-691A51/01 User manual

PCB Piezotronics
PCB Piezotronics IMI Sensors 691A50/05 User manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 691A51/03 User manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 691A50/06 User manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 691A50/08 User manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 682A00/06 User manual