PCE Health and Fitness VISTA-650E User manual

USER’S MANUAL
VISTA-650E/ VISTA-850E/ VISTA-1200E
Line Interactive UPS

Table Of Contents
1. Safety - Caution............................................................................................................................... 1
3. Installation and Operation.................................................................................................................3
5. Technical Specifications ...............................................................................................................6
2. System Introduction ........................................................................................................................ 2
4. Trouble Shooting Guide .................................................................................................................. 5
Thank you for purchasing this UPS system product. For utilizing its features and benefits,
please read the following instructions on its installation, usage and safety cautions thoroughly.

1. Safety – CAUTION
• This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The
unit contains no user serviceable parts. Only factory service personnel may perform repairs.
• Internal battery voltage is 24VDC sealed lead-acid, 6 cells battery two pcs for Vista-1200E and
12VDC sealed lead-acid, 6 cells one pc for vista-650E/ vista-850E.
• Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle
may result in shock hazard as well as it may violate local electrical codes.
• In the event of an emergency, press the OFF button and disconnect the power cord from the AC
power supply to properly disable the UPS.
• Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other
liquid-containing vessels on or near the unit.
• This unit intended for installation in a controlled environment (temperature controlled, indoor area
free of conductive contaminants). Avoid installing the UPS in locations where there is standing or
running water, or excessive humidity.
• Do not plug the UPS input into its own output.
• Do not attach a power strip or surge suppressor to the UPS.
• Do not attach non-computer-related items, such as medical equipment, life-support equipment,
microwave ovens, or vacuum cleaners to UPS.
• To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid
exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space
heaters or furnaces.
• Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
• Do not dispose of batteries in a fire as they may explode.
• Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and
eyes. It may be toxic.
• A battery can present a risk of electrical shock and high short circuit current. The following
precautions should be observed when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminals.
• Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries
and the required precautions. Keep unauthorized personnel away from batteries.
• When replacing batteries, replace with the same number and type of sealed lead-acid battery. The
maximum ambient temperature rating is 40°C.
1

• This pluggable type A equipment with battery already installed by the supplier is operator
installable and may be operated by laymen.
• During the installation of this equipment it should be assured that the sum of the leakage currents
of the UPS and the connected loads does not exceed 3.5mA.
• Attention, hazardous through electric shock. Also with disconnection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should
be therefore disconnected in the plus and minus pole of the battery when maintenance or service
work inside the UPS is necessary.
• The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily
accessible.
2. System Introduction
This UPS is specially designed for Personal Computer with multi-functions. Its light weight,
compact design fits to the limited working environment. The line of UPS is equipped with boost and
buck AVR to stabilize input voltage range. It has also built-in DC start function. This function
enables the UPS to be started up withoutAC power supplied.
Features
• Microprocessor control guarantees high reliability.
• Equipped with Boost and BuckAVR.
• Green Power Function for energy saving.
• DC Start Function.
•Auto restart whileAC recovery.
• Compact size, Light Weight.
• ProvidesAC Overload protection.
Front Panel
a. Power Switch
LED Indicators –
b. Normal: Green lighting
c. Battery Mode: Yellow flashing
d.AC Mode: Green lighting
e. Fault: Red lighting
2
Back Panel
f. Output outlets
g.AC input
h. USB port&RJ45
communication
a
c
f
e
g
b
d
h
2
Front Panel
1.Power Switch
2.LED Indicator –
AC Mode: Green lighting
Battery Mode: Green Flashing
Back Panel
3. AC input
4. Output outlets
VISTA-650E/ VISTA-850E
VISTA-1200E
1 3
4

3
3. Installation and Operation
Inspection
Placement
Recharge the UPS
Remove the UPS from its packaging and inspect it for damage that may occur during
shipping. If any damage is discovered, repack the unit and return it to the place of
purchase.
Install the UPS unit in any protected
environment that provides adequate airflow
around the unit, and is free from excessive
dust, corrosive fumes and conductive
contaminants. Do not operate your UPS in an
environment where the ambient temperature
or humidity is high.
On the other hand, place the UPS away from
the monitor at least 20cm to avoid
interference.
This unit is shipped from the factory with its
internal battery fully charged, however, some
charge may be lost during shipping and the
battery should be recharged prior to use.
Turn on the UPS, Plug the unit into an
appropriate power supply and allow the UPS
to be fully charged by leaving it plugged in for
at least 6 hours with no load (no electrical
devices such as computers, monitors, etc.)
connected.

4
All Series are equipped with DC Start function. To start the UPS when AC utility power
is not available, simply press the power switch.
All UPS is equipped with Green Power Function. For saving power and protecting
battery, the method of deep discharging protection is adopted on inverter mode
Plug the UPS into a 2-pole, 3-wire
grounded receptacle. Then
connect one computer-related
device into each of the power
receptacles supplied on the back
of the UPS.
To turn on the UPS unit, press the
power switch lightly. To turn off the
UPS unit, press the power switch
again.
Ϯ
Connection
Ϯʳ
Turn On/Off UPS
Ϯʳ
DC Start
Ϯʳ
Green Power Function

5
4. Trouble Shooting Guide
If any abnormal situations occur other than the listed below, please call service people immediately.
Alarm buzzer beeps continuously when AC supply is normal.
The UPS fails to turn on and No LED display on the front panel
When power failure, back-up time is shortened than the normal status
Mains normal but LED is flashing.
Possible Cause
Solut
ion
Battery weak. Charge battery up to 8 hours.
Battery defect. Replace with the same type of
battery.
Power switch is not pressed. Press the power switch again.
Possible Cause
Solution
Overload of the UPS. Verify that the load matches the
UPS capacity specified in the
specs.
Possible Cause
Solution
Overload of the UPS. Remove some non- critical load.
Battery voltage is too low. Charge battery 8 hours or more.
Battery defect due to high
temperature operation
environment, or improper
operation to battery.
Replace with the same type of
battery.
Possible Cause
Solution
Power cord is lost. Reconnect the power cord
properly.

6
5. Technical Specifications
E0021-atsiVE058-atsiVE056-atsiV
W027/AV0021W084/AV058W063/AV056
Voltage
Voltage Range
Voltage (on battery)
Frequency (on battery)
Output waveform
Transfer Time
Protection Full Protection
Normal Mode Green Lighting
AC Mode
Battery Mode Yellow Flashing
Fault Red Lighting
Battery Back up
Battery Low
Overload
Fault
Type
DC Voltage 24VDC
Typical Recharge Time
Protection
Back up Time
USB
Detect battery low, schedule UPS On/Off, AC
input/output power status display
Compatibility Novell,Windows 95 / 98 / ME /NT/Vista
/ 2000 / XP / 2003
Receptacles
Dimensions (WxDxH) mm
(
inch
)
139 x 365 x 195 (5.45”x 14.3”x 7.64”)
)29.81(6.8)11(5)86.9(4.4)sbl(gKthgieWgnippihS
Ambient Operation
Audible Noise
Storage Condition
Safety
Electromagnetic compatibility
Design, production & services
Environment
*Specifications may change without further notice
ISO 14001 certified company
100 x 278 x 143 (3.9”x 10.9”x 5.61”)
LED Indicators Green Flashing
N/A
N/A
N/A
Communication
N/A
N/A Available RJ45 Network communicaton port
Rapid beeping sound (every 0.5 sec)
165~280VAC
Modified Sinewave
Continuous beeping sound
Discharge, overcharge and overload protection
50 or 60Hz +/- 1 Hz
12VDC
Slow beeping sound (every 10 sec)
4 to 8 milliseconds, including detection time
Model Vista Series
Output power
<40dBA(1 meter from surface)
Optional country specific receptacles
Battery
Sealed lead acid, maintenance free, with 3-5 years lifetime
3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40°C
Green Lighting
Rapid beeping sound (every 1 sec)
220V/230V/240V
Standards &
certifications
Input
Environment
Output
Audible Alarm
Physical
220V/230V/240V +/-10%
6 hours (to 90% full capacity)
Automatic self-test discharge protection
EN 50091-2, EN 50022/B, IEC 62040-2, IEC 61000-3-2, IEC 61000-3-3
ISO 9001
EN 50091-1-1/EN 69050 (RD), IEC 60950
15,000 meters max.
30 min
RJ45

UMVISTA6512ENQ109
This manual suits for next models
2
Table of contents