Installation to Solid Concrete or Cinder Block
Use wall arm (A) as template to mark mounting holes.
The top mounting hole should be 7.54" (192 mm) above
the desired screen center as shown in figure 1.1 on
page 5. Drill three 5/16" (8 mm) dia. holes 2.5" (64 mm)
deep as shown in fig. 1.3. Insert anchors (D) into holes
flush with wall as shown. Place wall arm over anchors
and secure with three wood screws (C) using #3
screwdriver bit (L). Level, then tighten all fasteners.
Insert three fastener caps (F) into wall plate mounting
holes.
D
1
A
fig. 1.3
C
F
1
3
2
D
Drill holes and insert anchors (D).
Place plate (A) over anchors (D) and secure with screws (C).
Tighten all fasteners.
A
D
C
concrete
surface
CUTAWAY VIEW
INCORRECT CORRECT
wall
plate wall
plate
plaster/
drywall plaster/
drywall
concrete concrete
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable (not
evaluated by UL), the finishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8" (16 mm), custom fasteners must be supplied
by installer (not evaluated by UL).
WARNING
SOLID CONCRETE CINDER BLOCK
WALL PLATE