PENSAIR Hospital-grade User manual

Hospital-grade
air purier
— INSTRUCTION MANUAL
Rensair Instruction Manual UK v2.4 – 12pp A5 + 3mm bleed, CMYK

— HOW TO GET STARTED
1– Lift your Rensair air purifier out of the box.
2– Place the unit in the desired location.
3– Insert the power plug to your wall socket.
4– Press the power button [ ] to turn it on. The unit will start
in auto mode where the internal particle counter automatically
adjusts airflow settings based on the surrounding air quality.
To manually control the fan speed, press the fan speed button
[ ] to toggle between low, medium, high and auto.
5– That’s it. Your Rensair air purifier is now purifying the air.
How to turn your Rensair air purifier off:
Press the power button [ ] to turn the unit off.
Alternatively, you can use the timer function to determine when
the Rensair air purifier will automatically switch off. Press the timer
buttons [ / ] to increase or decrease the remaining operating
time. The control panel will display the remaining operating time.
2

CONTROL PANEL
AIR INLET
PERFORATIONS
AIR OUTLET
PERFORATIONS
WHEELS FOR
PORTABILITY
3

— CLEANING & MAINTENANCE
Always unplug the unit when cleaning or carrying out
maintenance. As an added safety feature, the power
will automatically switch off when the unit is tilted.
Cleaning the dust pre-filters
Pre-filters should be checked for dust or dirt on a weekly basis
and cleaned when necessary. Remove all four filters by pressing the
small clip button at the top and lifting them up. If possible shake
dust off outdoors. Use a vacuum cleaner or dry cloth to remove finer
dust. If needed, use mild soap and water to wash them. Make sure
the filters are completely dry before re-inserting them.
4

Cleaning the main body
Using a soft cloth (damp if necessary), gently wipe the outside of the
unit. Caution: Do not use alcohol, gasoline, thinners, acid, abrasives
or any other substances which could cause damage to the surface
of the main body. Water or other liquids should never enter the main
body of the unit.
Replacing the main HEPA 13 filter and UVC lamp
Your Rensair air purifier will run for 9000 hours before you need
to replace the HEPA 13 filter and UVC lamp.
Your Rensair air purifier will automatically alert you when the parts
need to be replaced via the ‘service indicator’ on the display panel
(see page 9). Changing the HEPA 13 filter and UVC lamp is easy
and can be done in five minutes. Instructions on how to change
the filter and lamp will be included in the box when you order your
replacement parts. Alternatively, visit rensair.com/maintenance
to view our online guide to changing these parts.
If you experience any issues with your Rensair air purifier please
contact your distributor or email support@rensair.com
5

UVC LAMP: The UVC lamp will
turn on by default when the unit
is running. It is recommended
to keep the UVC lamp on for
the highest air purification
effectiveness. To manually turn it
on/off press the UVC lamp button.
— CONTROL PANEL
ON/OFF: When switched on, the unit will
start in auto mode where the internal
particle counter automatically adjusts
the airflow settings based on surrounding
air quality. When the air quality is good,
the unit will automatically switch to
standby mode. If the surrounding air
particles increase the Rensair air purifier
will automatically turn on again.
REMOTE CONTROL: The Rensair air purifier can
also be controlled by the included remote control.
The buttons on the remote control correspond
to the buttons on the control panel. Note, the
remote control uses 2x AAA-batteries (not included).
6

TIMER + / -: Use the timer function
to apply or adjust a preset running time
for your Rensair air purifier. Press the
+/- buttons to increase or decrease the
operating time. The control panel will
display the remaining operating time.
The machine will automatically switch
off once this time has elapsed.
FILTER LIFE RESET:
Note – This function should only
be used after the HEPA 13 filter and
UVC lamp have been changed.
See cleaning and maintenance
on page 4 and 5.
FAN SPEED: To manually control the fan speed, press the fan
speed button to toggle between low, medium, high and auto.
RENSAIR AIRFLOW
VOLUME
CUBIC METERS
M³/HOUR
NOISE
LEVEL
POWER
USAGE
Low setting 300 45dBA 160W
Medium setting 430 52dBA 180W
High setting 560 59dBA 220W
tolerance +/- 10%
7

— DISPLAY
Auto mode: this is the default mode when
the unit is first turned on. The Rensair
air purifier will operate continuously
in auto mode if the air quality is deemed
unsatisfactory.
Fan speed indicator: 1 (low), 2 (medium),
3 (high).
UVC lamp on/off indicator.
When Timer mode is in use, the display
panel will indicate the remaining run time.
Otherwise the panel will display the room
temperature.
The temperature indicator displays the
room temperature.
8

The service indicator displays the remaining life of the HEPA 13
filter and UVC lamp. When all the bars are continuously illuminated
to the illustration on the right, it is time to service the unit.
Please visit Rensair.com to order a new HEPA 13 filter and UVC lamp.
For instructions on how to change the HEPA 13 filter and UVC lamp
go to: rensair.com/maintenance
The air indicator shows the quality of the air based on the number
of particles entering the unit. The fewer the bars, the better.
9

— SPECIFICATIONS
Rensair Q01B
220-240V, ~50Hz, IEC C14 to C13 connector to allow for different
power plugs, CE & UKCA marked
Dimensions: H:77cm, Ø37cm
Box Dimensions: H: 84cm x W: 43cm x D: 43cm
Net weight: 18kg
Gross Weight (including box): 21kg
Colour: White
HEPA filter: EU13 (EN 1822 class H13)
UVC lamp: 18W, 254nm light
Length of power cord: 3m
10

PRE-FILTER
FAN
UVC LAMP
HEPA 13 FILTER