Pentair DC20 Manual

12V Portable Diaphragm Compressor
Operating and Maintenance Instructions
(Part No. DC20)
Part No. Serial Number Date Purchased
2395 Apopka Blvd. •Apopka, FL 32703 •Phone: 877-347-4788 •Fax: 407-886-6787 •PAES.General@Pentair.com •PentairAES.com

Table of Contents
Page
Safety Messages ..............................................................................2
Guidelines for Product Use .............................................................2
Operation Guidelines .......................................................................2
Installation .....................................................................................2
Plumbing .......................................................................................3
Starting..........................................................................................3
General Maintenance.......................................................................3
Flushing the Muffler System...........................................................3
Frequently Asked Questions (FAQ) ................................................3
Pump Curves ....................................................................................4
Limited Warranty..............................................................................4
Exploded View of Compressor........................................................5
Repair Kit Parts List.........................................................................5
Safety Messages
Safety is important to us. We have included safety messages
throughout this manual and for your protection. Please read and follow
all directions.
A safety message has a safety alert symbol
followed by an explanation of what the hazard
is, what can happen and what you should do
to avoid injury. This is the safety alert symbol:
The safety alert symbol and "WARNING" or "CAUTION" will precede
all safety messages:
WARNING
You will be killed or seriously injured if you don't follow
instructions.
CAUTION
You can be killed or seriously injured if you don't follow
instructions.
• Do not pump flammable or explosive gases or use in an atmosphere
that contains such gases.
• Protect all surrounding items from exhaust air. This exhaust air can
become very hot.
• Corrosive gases and particulate material will damage the unit. Water
vapor, oil-based contaminants or other liquids must be filtered out.
• Do not flush with kerosene or other combustible solvents.
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit breaker or fuse box before
installing this product. Install where it will not come into contact with
water or other liquids and where it will be weather protected. Electrically
ground this product. Failure to follow these instructions can result in
death, fire or electrical shock.
Guidelines for Product Use
• Pump only clean, dry, atmospheric air.
• Operate at 32–104°F (0–40°C).
• Protect unit from dirt, foreign material and moisture.
• Never lubricate oilless air compressors.
Operation Guidelines
Installation
Make sure the wiring is done by a qualified electrician familiar with
NEMA MG2 safety standards, national electric code and all local safety
codes. Select fuses, motor protective switches or thermal protective
switches to provide protection. Fuses act as short circuit protection for
the motor, not as protection against overload. Incoming line fuses help
to withstand the motor's starting current. Motor starters with thermal
magnetic overload or circuit breakers protect the motor from overload
or reduced voltage conditions. The wiring diagram attached to the
product provides required electrical information.
Make sure that installation clearances do not block air flow. Blocking air
flow over the product in any way can cause the product to overheat.
2395 Apopka Blvd. •Apopka, FL 32703 •Phone: 877-347-4788 •Fax: 407-886-6787 •PAES.General@Pentair.com •PentairAES.com
2

WARNING
Product surfaces become very hot during operation; allow them to cool
before handling.
The air stream from this product may contain solid or liquid material
that can cause eye or skin damage; wear proper eye protection.
Failure to follow these instructions can result in burns, eye injury
or other serious injury.
Each model has an automatic thermal protector that shuts the motor
off if it overheats. The motor will restart without warning once the
protector resets itself upon cooling.
This product can be installed in any orientation, provided that the flow
of cool, ambient air is not blocked. To minimize noise and vibration,
the nit should be mounted on a solid surface that will not resonate.
We recommend the use of shock mounts or vibration isolation
material. Inlet noise can be minimized by attaching an optional muffler.
Plumbing
Remove plugs from the IN and OUT ports. Connect with pipe
and fittings that are the same size or larger than the product's
threaded ports.
Starting
If the compressor is extremely cold, allow it to warm to room
temperature before starting. If the motor fails to start or slows down
when under load, shut it off and unplug it. Check that the supply
voltage agrees with the motor post terminals and motor data name
plate, and make sure the motor is turning in the proper direction.
General Maintenance
WARNING
When servicing, all power to the motor must be discharged and the
plug disconnected. All rotating components must be at a standstill.
Make sure that pressure and vacuum are released from the product
before starting maintenance. Check intake and exhaust filters after the
first 500 hours of operation. Clean filters, and determine how frequently
filters should be checked during future operation. This procedure in
particular will help the product's performance and service life.
1. Remove the end plate and filters. Inspect filters for rips, tears, cuts,
brittleness and excessive foreign material.
2. Clean filters if in good condition with compressed air. Reinspect for
wear conditions. Set filters aside.
3. Check the filter/muffler for compacted debris. If debris is present,
replace the filter/muffler.
4. Check the condition of O-ring. It should be soft and flexible.
Replace if it is not.
5. Remove and inspect the muffler box (not all models have a muffler
box). Clean the box and set it aside.
6. Check the gasket for cracks or tears. Install new gasket if any cracks
or tears exist.
7. Replace the muffler box.
8. Reinstall filters or install new filters if required. Reinstall the end plate.
Flushing the Muffler Assembly
Should excessive dirt, foreign particles, moisture or oil be permitted
to enter the compressor, the vanes will act sluggish or even break.
Flushing the muffler assembly should remove these materials. Do not
use kerosene or other combustible solvents. Use flushing solvent (part
no. AQ255) liberally to clean muffler parts.
Frequently Asked Questions (FAQ)
Is my compressor running too hot?
It is normal for a motor to run hot to the touch because the shell
transfers heat away from the motor windings.
However, improved materials used in motor manufacturing make the
"too-hot-to-touch" test obsolete. The best way to determine if a motor
is operating properly is to check the ampere (amp) draw. Each motor
has a nameplate listing full-load amps (FLA). If the tested amp draw
does not exceed the nameplate rating, its internal or external cooling
fan is working (if so equipped), and the ambient air temperature around
the motor is below 104°F (40°C). The motor is probably not running
hot, even though it is too hot to touch.
Even so, make sure that there is plenty of air flow around the motor,
and keep the area around the motor clear so that there is no blockage
of air flow to the motor. Also keep paint and other flammable materials
away from the motor.
How much will it cost to operate my compressor?
The cost of operation will depend on the length of time the compressor
is run each day. The following example is for a typical 1-hp, single-phase
compressor operated 24 hours a day at $.08 per kWh. The cost per
kWh will vary from location to location. Check your electric bill for the
cost per kWh.
9.7 amps x 115 volts = 1,115.5 watts (amps & volts are
on motor nameplate)
1,115.5 watts x 1,000 = 1.116 kW
1.116 kW x 24 hrs = 26.77 kWh
26.77 kWh x $.08 per kWh = $2.14 per day
Why is my compressor so noisy?
Compressor noise can be the result of vibration or mechanical noise.
1. Vibration is the intensification of normal compressor noise.
The noise should decrease if the compressor is firmly attached
to the foundation or if the compressor is completely isolated
by using a rubberized or cushioned base.
2. Mechanical noise is typically a high-pitched squealing sound.
The most common causes include worn motor bearings and
rubbing of the impeller against the compressor housing.
2395 Apopka Blvd. •Apopka, FL 32703 •Phone: 877-347-4788 •Fax: 407-886-6787 •PAES.General@Pentair.com •PentairAES.com
3

0
0
2
4
6
8
10
246810 12
0
0
0.4
0.8
1.2
1.6
20
246810 12
Flowrate vs. Pressure
Current vs. Pressure
Pressure (psi)
Pressure (psi)
Flowrate (cfm) Current (amps)
DC20 Pump Curves
2395 Apopka Blvd. •Apopka, FL 32703 •Phone: 877-347-4788 •Fax: 407-886-6787 •PAES.General@Pentair.com •PentairAES.com
4
LIMITED WARRANTY
Pentair Aquatic Eco-Systems, Inc. (PAES) warrants that its products
shall, at the time of delivery and for a period of twelve (12) months
thereafter, except for filters, be free from l defects in materials and
workmanship; and, if any such product shall prove to be defective
in material or workmanship under normal intended usage and
maintenance during the warranty period, upon examination by PAES
or its authorized representative, then PAES shall repair or replace, at
its sole option, such defective products at its own expense; provided,
however, that the Purchaser shall be required to ship each such
defective product, freight prepaid, to PAES' designated facility. The
warranty on products and/or components not manufactured by PAES,
is limited to the warranty, if any, provided by the original manufacturer
of said product or component. PAES sole warranty in regard to
any components or products that are not manufactured by it shall
be limited to the repair or replacement of the product, as set
forth herein, with the condition that the Purchaser first return such
defective item, freight prepaid, to PAES' designated facility. After
PAES has made an inspection of the product, and has confirmed that
there is a defect in the manufacture of the product, a credit will be
issued to Purchaser's account. PAES HAS MADE NO AFFIRMATION
OF FACT AND HAS MADE NO PROMISE RELATING TO THE
GOODS BEING SOLD THAT HAS CREATED OR AMOUNTED TO AN
EXPRESS WARRANTY OR THAT THE GOODS CONFORM TO ANY
AFFIRMATION OR PROMISE. PAES DISCLAIMS ANY IMPLIED
WARRANTY OF MERCHANTIBILITY AND FITNESS. PAES SHALL
NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES
RESULTING FROM ANY PRODUCT DEFECT. THERE ARE NO
WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON
THE FACE HEREOF.
This Warranty does not extend to any Equipment that have been
subjected to:
1. Damage caused by careless handling, improper repackaging,
or shipping.
2. Damage due to misapplication, misuse, abuse or failure to
properly operate equipment.
3. Damage caused by improper installation or storage.
4. Damage due to unauthorized product modifications
or repairs.
5. Damage caused by negligence, or failure to properly
maintain products.
6. Accidental damage, fire, acts of God, or other circumstances
outside the control of PAES.

Should you require service or repair parts, contact Pentair Aquatic
Eco-Systems at 877-347-4788 from 8 AM to 7 PM Monday to
Thursday and 8 AM to 5 PM Friday. Have your part and serial
numbers handy, and our technical staff will gladly help you
resolve any problems.
Ref.
No. Description Part
Qty
1 Diaphragm 1
2Brush Card Assembly 1
3Valve Flapper 2
4 O-Ring 1
5Filter Element 1
Exploded View & Parts Included in Repair Kit
2395 Apopka Blvd. •Apopka, FL 32703 •Phone: 877-347-4788 •Fax: 407-886-6787 •PAES.General@Pentair.com •PentairAES.com
5
Table of contents
Other Pentair Air Compressor manuals