Pentair PENTEK UVS-110 User manual

PENTEK®MODELS UVS110, UV110, UV120, UVBB120
UV Water SYSteMS InStrUctIon ManUal
www.pentairaqua.com

MODELS
Model
Part #
(120v/60Hz)
Part #
(220v/50Hz)
UVS-110 163003 163004
UV-110 163005 163006
UV-120 163007 163008
UVBB-120 163009 163010
APPLICATION
Ultraviolet Water Disinfection
SPECIFICATIONS
Models: UVS-110 UV-110 UV-120 UVBB-120
Maximum Operating
Pressure
65 psi 65 psi 65 psi 65 psi
Temperature
Range
40-100˚F
(4.4-37.8˚C)
40-100˚F
(4.4-37.8˚C)
40-100˚F
(4.4-37.8˚C)
40-100˚F
(4.4-37.8˚C)
Flow Rate @ 60 psi
(4.1 bar)
1 gpm
(3.8 Lpm)
2 gpm
(7.6 Lpm)
8 gpm
(30 Lpm)
15 gpm
(56 Lpm)
Voltage (Domestic)
120v/60Hz 120v/60Hz 120v/60Hz 120v/60Hz
Voltage (Int’l)
220v/50Hz 220v/50Hz 220v/50Hz 220v/50Hz
CBU Cartridge
The UVS-110 and the UV-110 are supplied with a carbon block filter
cartridge which reduces sediment, bad taste and odor.
GENERAL PRECAUTIONS
Always disconnect the UV from the power
source. Follow the procedures provided in
this manual. Improper handling can result in
death or serious injury.
Do not look directly at the UV lamp. This can
cause retina/eye damage.
Do not touch the UV bulb. Any fingerprints or
dirt will reduce the efficiency of the bulb and
may cause it to explode.
Observe caution when inserting quartz sleeve
to prevent breakage and cracking, which may
result in injury and damage to unit.
NOTE: When handling the UV bulb hold only the plastic-
covered ends of the bulb. If the bulb has been touched,
remove bulb and clean with alcohol before reinserting.
If water pressure exceeds 65 psi, a pressure
regulator, set at less than 65 psi, must be installed
before the Ultraviolet system.
Install on cold water lines only.
Do not install where system is exposed to
direct sunlight.
Do not use wicking or sealing agents for fitting
connections. Plumbers tape is recommended.
This system must be protected from
freezing which can cause cracking of the
filter housing and water leakage.
Because of the product’s limited service life,
and to prevent costly repairs or possible water
damage, we strongly recommend that the bottom
of all opaque housings be replaced every ten
years. If the bottom of your housing has been
in use for more than this period, it should be
replaced immediately. Date the bottom of any
new or replacement housing to indicate the next
recommended replacement date.
NOTE: Filter cartridge life varies depending on filter type,
usage and water conditions
.
For the UVS-110 and UV-110
Allow a minimum of 12 inches clearance under the filter for
changing the cartridge, and above the system to allow the UV
bulb to be changed.
For the UV-120 and UVBB-120
Allow a minimum of 20 inches clearance under the filter for
changing the cartridge, and above the system to allow the UV
bulb to be changed.
CARTRIDGE REPLACEMENT
(for UVS-110 and UV-110 only)
Your cartridge should be replaced when there is a noticeable
drop in water flow at the faucet or tap, and/or when unpleasant
odors return (approximately every 6-9 months).
1. Turn off water supply to the system.
2. Open faucet to relieve water pressure to the housing.
3. Unscrew housing from cap. If housing sticks or is difficult to
open use an Pentek spanner wrench.
4. Remove used cartridge from housing, remove plastic sleeve
and discard cartridge.
5. Remove O-ring from groove below the threads of the
housing and wipe groove and O-ring clean. Lubricate O-ring
with silicone grease. Place O-ring back into the groove.
With two fingers wipe or press O-ring down into the groove.
Note: This step is important to ensure a proper filter seal.
Make sure that the O-ring is seated level in the groove.
6. Insert a new cartridge into the sump making sure that it
slips down over the sump standpipe.
7. Remove gasket from cartridge end and slide plastic
sleeve into center of cartridge then replace gasket on top
of cartridge.
8. Screw the sump onto the cap and hand-tighten. Do not over-
tighten. Make sure that the cap slips over the cap standpipe
.
9. Turn on the water supply to allow the unit to slowly fill
with water.
10. Check for leaks before leaving installation.
11. Each time that you use water from your unit for drinking or
cooking purposes, it is recommended that you run (flush)
the tap for at least 10 seconds prior to using water. This is
particularly important if the water tap is not used daily.
UV LAMP REPLACEMENT
1. Turn off all electrical power to the system by unplugging or
throwing the circuit.
2. Unscrew the UV control module from the mounting bracket (4
screws) for Models UV-110, UV-120 and UVBB-120. For Model UVS-
100, slide mounting bracket retainer to allow access to the UV bulb.
3. Slide the old bulb out and unplug from the control module.
Note: Hold the UV lamp only by the plastic covered ends of
the bulb.
4. Carefully discard the old UV lamp.
5. Holding the new UV lamp only by the plastic covered ends of the
bulb, plug the new UV lamp into the control module or power cord.
Slide the new bulb into the cartridge housing and reattach UV
control module or secure mounting bracket retainer (depending
on model).
6. Restore electrical power to unit.
7. Check for leaks.
2 • PENTEK®UV Water Systems Instruction Manual

PENTEK® UV Water Systems Instruction Manual • 3

4 • PENTEK®UV Water Systems Instruction Manual
UVS-110
REPLACEMENT PARTS
Part Desciption Part #
1. 10" Slim Line™ Housing 153017
2. O-ring 143026
3. CBU-10 155271-03
4. Plastic Sleeve 163518
5. Quartz Sleeve 163504
6. O-rings for Quartz Sleeve 163538
7. 1/2" Black Cap w/o pr SPECIAL ORDER
8. Spacer Bushing 163517
9. Mounting Bracket SPECIAL ORDER
10. UV Lamp 163503
11. Control Module (120v/60Hz)
Control Module (120v/60Hz)
163501 - for use with
UVS-110-1
163502 - for use with
UVS-110-2
12. SW-1 Wrench 150539
UV-110
REPLACEMENT PARTS
Part Desciption Part #
1. 10" Housing 153001
2. O-ring 143011
3. CBU-10 155271-03
4. Plastic Sleeve 163518
5. Quartz Sleeve 163509
6. O-rings for Quartz Sleeve 163516
7. Plunger Rod w/Retainer 163519
8. 1/2" Black Cap w/o pr SPECIAL ORDER
9. Spacer Bushing 163517
10. Mounting Bracket SPECIAL ORDER
11. UV Lamp 163508
12. Control Module (120v/60Hz)
Control Module (120v/60Hz)
163506 - for use with
UVS-110-1
163507 - for use with
UVS-110-2
13. SW-1 Wrench 150295
120 V/60 Hz
420 Amp
Control Module
SW-1

PENTEK® UV Water Systems Instruction Manual • 5
UV-120
REPLACEMENT PARTS
Part Desciption Part #
1. 20" Housing 153013
2. O-ring 143011
3. Gasket for Insert Sleeve 163515
4. Stainless Steel Insert Sleeve 163514
5. Quartz Sleeve 163513
6. O-rings for Quartz Sleeve 163516
7. Plunger Rod w/Retainer 163519
8. 3/4" Black Cap w/o pr SPECIAL ORDER
9. Spacer Bushing 163517
10. Mounting Bracket SPECIAL ORDER
11. UV Lamp 163512
12. Control Module (120v/60Hz)
Control Module (220v/50Hz)
163510 - for use with
UV-120-1
163511 - for use with
UV-120-2
13. SW-2 Wrench 150295
UVBB-120
REPLACEMENT PARTS
Part Desciption Part #
1. 20" BB Housing w/SS sleeve SPECIAL ORDER
2. O-ring 143273
3. Quartz Sleeve 163548
4. Plastic Holder w/O-rings 163543
5. Plastic Tube 163545
6. 11⁄2" Black Cap w/o pr 153541
7. Mounting Bracket SPECIAL ORDER
8. UV Lamp 163512
9. Control Module (120v/60Hz)
Control Module (220v/50Hz)
163542 - for use with
UVBB-120-1
163547 - for use with
UVBB-120-2
10. SW-3 Wrench 150296
1
2
9
7
8
4
3
5
6
10

MAINTENANCE
The quartz sleeve should be cleaned with warm soap and water
every three months.
UV bulb should be replaced every 9-12 months. The bulb does
not normally burn out, however the efficiency of the bulb
decreases after one year.
Contact your local water treatment professional for replacement
cartridge and bulb pricing or call 1-800-645-0267 for a dealer
near you.
Leaks
At inlet/outlet connections:
• Use Plumber tape.
Between cap and housing:
• Make sure that the O-ring is clean, lubricated and
properly seated.
• Hand-tighten the housing.
• Check cartridge length. If cartridge is too long, replace
with proper length cartridge.
At UV quartz sleeve:
• Turn off all electrical power to the unit by unplugging or
throwing the circuit.
• Remove UV lamp and unscrew housing (See UV lamp
replacement).
• Check quartz sleeve for cracks, leaks and loose fittings.
• Check that O-rings between quartz sleeve and cap are
secure and have not been cut or damaged.
• If the sleeve is broken replace with a new quartz sleeve
and new O-rings.
6 • PENTEK®UV Water Systems Instruction Manual

PENTEK® UV Water Systems Instruction Manual • 7

FILTRATION & PROCESSING SOLUTIONS
5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209
P: 262.238.4400 |WWW.PENTAIRAQUA.COM |CUSTOMER CARE: 800.279.9404 |tech-supportpentair.com
All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their
respective owners. Because we are continuously improving our products and services. Pentair reserves the right to change specifications without prior notice.
Pentair is an equal opportunity employer.
145453 REV D MR13 © 2013 Pentair Residential Filtration, LLC All Rights Reserved.
This manual suits for next models
3
Table of contents
Other Pentair Water System manuals
Popular Water System manuals by other brands

GE
GE MERLIN 1255052 Installation and maintenance manual

Solar Roofs
Solar Roofs Fireball 20014 installation manual

Aquacentrum
Aquacentrum HIGHDROGEN AGE2 GO Blue900 user manual

AquaScape
AquaScape IonGen Installation Instructions & Maintenance Owner's Manual

Schier
Schier GB-75-B installation guide

Hypertherm
Hypertherm HT2000 instruction manual

Wesco
Wesco WES50 instructions

BIO-MICROBICS
BIO-MICROBICS BioBarrier 0.5 installation manual

Little Giant
Little Giant WCR Series installation instructions

AquaticLife
AquaticLife RO Buddie 75 GPD Installation, operation, maintenance guide

Pure-Pro
Pure-Pro RO101 user manual

Puretec
Puretec IL-TM Series user guide