PERCo WMD-06 Installation and operating instructions

ASSEMBLY AND OPERATION MANUAL
WMD-06
Motorized Electromechanical
Swing Gate

WMD-06
Motorized
electromechanical
swing gate
Assembly and Operation Manual

CONTENTS
1APPLICATION.............................................................................................................................. 3
2OPERATING CONDITIONS......................................................................................................... 3
3TECHNICAL SPECIFICATIONS .................................................................................................. 3
4DELIVERY SET............................................................................................................................ 4
4.1Standard delivery set ........................................................................................................ 4
4.2Optional equipment (upon request) .................................................................................. 5
5DESCRIPTION............................................................................................................................. 5
5.1Main features .................................................................................................................... 5
5.2Design............................................................................................................................... 5
5.3RC-panel........................................................................................................................... 8
5.4Input and output signals parameters ................................................................................ 9
5.5Abnormal situations during gate operation ..................................................................... 12
6MARKING AND PACKAGING.................................................................................................... 12
7SAFETY REQUIREMENTS ....................................................................................................... 12
7.1Installation safety ............................................................................................................ 12
7.2Operation safety ............................................................................................................. 12
8ASSEMBLY AND INSTALLATION............................................................................................. 13
8.1General recommendations ............................................................................................. 13
8.2Tools and equipment required for installation................................................................. 13
8.3Appropriate cable length................................................................................................. 13
8.4Installation procedure ..................................................................................................... 13
9OPERATION .............................................................................................................................. 16
9.1Power-up ........................................................................................................................ 16
9.2Pulse control mode ......................................................................................................... 17
9.3Potential control mode .................................................................................................... 17
9.4Emergency situations ..................................................................................................... 18
9.5Troubleshooting .............................................................................................................. 18
10TRANSPORTATION AND STORAGE ....................................................................................... 18
11MAINTENANCE ......................................................................................................................... 18
APPENDIX A. Control signal algorithm in pulse control mode .............................................. 19
APPENDIX B. Control signal algorithm in potential control mode ......................................... 19

WMD-06 Motorized electromechanical swing gate
Dear customer!
Thank you for purchasing the PERCo product.
Please follow instructions given in this Manual carefully,
and this quality product will provide many years of trouble-free use.
The Assembly and Operation Manual (hereinafter – the Manual) contains the instructions the
user will need for safe transportation, storage, installation, operation and maintenance of the
WMD-06 motorized electromechanical swing gate.
The product installation must be carried out by qualified installers in strict accordance with the
Manual.
Abbreviations adopted in the Manual:
ACS – access control system;
RC – remote control;
WRC – wireless remote control.
1 APPLICATION
The WMD-06 motorized electromechanical swing gate (hereinafter – the swing gate) is
designed for managing pedestrian flows at entrance points of industrial facilities, banks,
administrative buildings, retail outlets, railway terminals, airports, etc. Being an up-market model, it
is recommended to meet the highest requirements for design and comfort. It can be installed
together with other turnstiles and railings produced by PERCo or it can be used as a separate
device.
It is recommended to define the number of swing gates necessary to secure fast and convenient
passage in accordance with throughput rate (see Section 3). For example, it is recommended to
install one turnstile per 500 people on the basis of maximum working load of 12 persons/min.
2 OPERATING CONDITIONS
The swing gate, with regard to resistance to environmental exposure, complies with
GOST 15150-69, category U4 (operation in premises with climate control).
Operation of the swing gate is allowed at ambient air temperature from +1°Сto +50°Сand at
relative air humidity of up to 70% at +27°С.
3 TECHNICAL SPECIFICATIONS
Operating voltage ....................................................................................................... 24 V DC ±10%
Current consumption......................................................................................................... max. 4.4 А
Power consumption ........................................................................................................ max.105 W
Throughput rate in single passage mode................................................................... 12 persons/min
Operating modes ............................................................................................................................. 3
Passageway width with AGG-650 swing panel .................................................................... 700 mm
Passageway width with AGG-900 swing panel .................................................................... 950 mm
Length of RC cable1.......................................................................................................... min. 6.6 m
IP Code .................................................................................................................... IP41 (EN 60529)
Electric shock protection class .................................................................................... III (IEC 61140)
Mean time to failure ..................................................................................... min. 500 000 passages
Mean lifetime .................................................................................................................. min. 8 years
Overall dimensions with AGG-650 swing panel ................................................. 795×147×1012 mm
Overall dimensions with AGG-900 swing panel ............................................... 1045×147×1012 mm
Net weight with AGG-650 swing panel ............................................................................ max. 37 kg
Net weight with AGG-900 swing panel ............................................................................ max. 41 kg
1Maximum length of RC cable is 30 m (upon request).
3

Assembly and Operation Manual
Figure 1. Overall dimensions
4 DELIVERY SET
4.1 Standard delivery set
Basic equipment:
Gate post:
fixed base ............................................................................................................................... 1
housing ................................................................................................................................... 1
cover ....................................................................................................................................... 1
Glass panel ................................................................................................................................. 1
Note:
Type of panel, AGG-650 (700 mm passageway width) or AGG-900 (900 mm passageway
width) is chosen by the customer.
RC panel with cable .................................................................................................................... 1
SW1.5 Allen wrench .................................................................................................................... 1
Gate mounting kit:
PFG IH 10 (SORMAT, Finland) anchor bolt with washer and M10 nut ....................................... 3
Panel installation kit:
M10×35 bolt ................................................................................................................................. 4
M10 nut ........................................................................................................................................ 4
Spring washer .............................................................................................................................. 4
Expanded washer ........................................................................................................................ 8
Plastic bushing ............................................................................................................................. 4
Operational documentation:
Certificate ..................................................................................................................................... 1
Assembly and operation manual ................................................................................................. 1
Template for gate installation ........................................................................................................1
Package:
Box 1 (gate post and RC-panel) .................................................................................................. 1
Box 2 (swing panel) ..................................................................................................................... 1
4

WMD-06 Motorized electromechanical swing gate
4.2 Optional equipment (upon request)
In addition to the standard delivery set the following equipment can be supplied on request:
Power supply unit .........................................................................................................................1
WRC kit1.......................................................................................................................................1
5 DESCRIPTION
5.1 Main features
The swing gate can operate both as a standalone unit and as a part of the ACS. Two control
modes are available: pulse control mode and potential control mode.
The swing gate can be supplied with two types of swing panel: 650 mm or 900 mm. Overall
dimensions of the gate are shown in Fig. 1.
External components of the swing gate (except for swing panel) are made of polished stainless
steel. The swing panel is made of 10 mm thick tempered glass.
The swing gate is a normally open unit i.e. in case of power failure the swing panel can rotate
±90º.
Safe operating voltage – max. 28 V.
Low power consumption – max. 105 W.
5.2 Design
Design of the swing gate is shown in Fig. 2. The numbers of the items in brackets are given
according to Fig. 2, unless stated otherwise.
The gate consists of the fixed base (1), rotary support (7) that holds glass panel (4), housing (2)
and cover (3). The metal (5) and plastic rings (12) provide support of housing (2) and its rotation
around fixed base (1). Decorative plate (15) is fixed with a screw (16).
The gate post is installed on anchors stud-bolts (9) and fixed with nuts (10) and washers (11)
The gate post contains units providing its operation: rotary electric drive with rotation sensor,
electromagnetic stopper unit, bearing units, drive control board (6).
RC panel is included into delivery set (17).
The gate is operated with +24 V DC voltages via cable (13).
The control board is installed inside the gate post. The control board overview is shown in Fig. 3.
The control board contains:
XT1 and XT2 – terminal blocks are designed for power supply, input-output of control signals
and indication. Marking and description of XT1 and XT2 terminal block contacts of the control
board are given in Table 1.
Size
– connector is designed for selection of swing panel type installed on the gate. If the
AGG-900 panel is used, the jumper shall be removed, if the AGG-650 panel is used – the
jumper shall be installed. The jumper is removed by default.
Imp / Pot – connector is designed for selecting gate control mode. If the jumper is installed,
the gate operates in the pulse mode, if the jumper is not installed, the gate operates in the
potential mode. The jumper is installed by default.
FireAlarmDir – connector is designed for selecting gate opening direction when the Fire
Alarm emergency unlocking signal is applied. If the jumper is installed, the swing panel opens
in direction A (see Figure 5), if the jumper is not installed, the swing panel opens in direction B.
The jumper is installed by default.
LED – connector is designed for turn-off of LED indicators located on the control board. If the
jumper is installed, indication is on. If the jumper is not installed, indication is off. The jumper is
installed by default.
1 WRC kit consists of a receiver connected to the gate control board and two transmitters (tags) with
operating range up to 40 m.
5

Assembly and Operation Manual
Figure 2. Overall view of the gate
1 – fixed base; 2 – housing; 3 – cover; 4 – glass panel; 5 – metal ring;
6 – control board;7 – rotary support; 8 – M3 screw (3 pcs); 9 – anchor stud-bolt; 10 – M10 nut;
11 – washer; 12 – plastic ring; 13 – power cable;
14 – control cable (from RC panel / WRC device / ACS controller);
15 – decorative plate; 16 – screw M4; 17 – RC panel
6

WMD-06 Motorized electromechanical swing gate
Figure 3. Control board overview
XT1, XT2 – terminal blocks; 1 – power cable +24 V;
2 – control cable (from RC panel / WRC unit / ACS controller);
3 –jumper wire (installed by default);
4 – connectors (all jumpers are installed by default); 5 – LED indicators.
Table 1. Contacts of the control board
Terminal
block No. Item Designation
1 +24 V
2 GND External power supply connection
3 NO
4 C
5 NC
Light A relay contacts – remote indicator connection for
direction А
6 NO
7 C
8 NC
Light B relay contacts – remote indicator connection for
direction В
9 +12 V Power supply positive terminal of RC-panel
10 GND Power supply negative terminal
11 Common Common contact for PASS А, PASS Вsignals
12 Pass A PASS A relay contact (passage in direction А)
ХТ1
13 Pass B PASS Вrelay contact (passage in direction В)
7

Assembly and Operation Manual
Terminal
block No. Item Designation
1 Fire Alarm
2 GND Input for emergency unlocking device
3 GND Power supply negative terminal
4 Unlock A
5 Stop
6 Unlock B
Inputs for gate control
7 Led A
8 Stop
9 Led B
Indication outputs of RC panel
ХТ2
10 Sound Sound signal output of RC panel
5.3 RC-panel
The RC-panel (17) is a small desktop device made of shockproof ABS plastic that serves for
manual setting of the operating modes and indication thereof. RC-panel is connected to the control
board (6) with flexible multicore cable (14), included into delivery set. The RC-panel overview is
shown in Figure 4.
The RC panel features three control buttons to set swing gate passage modes. The buttons LED
indicators are located above. The STOP button in the middle serves for setting the “Always
locked” operating mode, the RIGHT and LEFT buttons – for allowing passage in the chosen
direction. The RC panel features a built-in piezoelectric buzzer for audio signals generation.
The standard orientation of the RC panel in relation to gate opening direction is shown in Figure 5.
The orientation of the RC panel buttons can be changed if necessary, in such case the connection
of RC panel shown in Fig. 11 shall be changed by swapping the cable of the RC panel to XT2
terminal block in accordance with Table 2.
Figure 4. RC panel overview and dimensions
1, 2, 3 – LEFT, RIGHT, STOP buttons for mode setting;
4, 6 – “Left” and “Right” green indicators; 6 – “Stop” red indicator
8

WMD-06 Motorized electromechanical swing gate
Figure 5. Standard orientation of RC panel relative to gate opening direction
Table 2. Connection of RC panel cable to XT2 connector block in standard and reversed
orientation of the RC panel
Orientation
Number Title Standard Reversed
1 Fire Alarm - -
2 GND - -
3 GND black black
4 Unlock A white green
5 Stop blue blue
6 Unlock B green white
7 Led A yellow red
8 Stop orange orange
9 Led B red yellow
10 Sound brown brown
5.4 Input and output signals parameters
The microcontroller installed on the control board tracks the status of Unlock A, Stop, Unlock B and
Fire Alarm control input signals, and also tracks output signals from rotation sensor.
Upon received data the microcontroller generates commands for the gate control mechanism and
also signals for connected external indication devices, indication on the RC panel (Led A, Led Stop
and Led B), signals on the performed rotation of the swing panel on outputs Pass Аand Pass В.
5.4.1 Inputs for control devices connection
The swing gate can be operated with RC panel, WRC device or ACS controller.
A device that sends Fire Alarm signal is used for passage emergency unlocking.
Note:
Control devices (RC panel, WRC device, ACS controller) can be connected separately or in
any combination with each other.
In case of combined connection, the overlapping of signals sent by control devices may
occur. In such case the reaction of the gate will correspond with the reaction towards the
generated combination of input signals.
9

Assembly and Operation Manual
Control devices are connected to Unlock A, Stop and Unlock B control inputs. The gate is operated
by applying a low-level signal to Unlock A, Stop, Unlock B contacts with GND contact of XT2
terminal block.Algorithms of control signals sending are given in Appendices A and B.
A normally open relay contact or open collector output circuit can be used as a control element
(see Figure 6 and Figure 7).
Figure 6. ACS control element – normally open relay contact
Figure 7. ACS control element – open collector output circuit
The device that sends Fire Alarm emergency unlocking signal is connected to the Fire Alarm
control input.Emergency unlocking is performed by turn-off of the low-level signal at Fire Alarm
contact and GND contact on XT2 terminal block. In such case a normally closed contact or open
collector output circuit can be used as a control element.
If the Fire Alarm input is not used, it is necessary to install a jumper between Fire Alarm and GND
contacts on the XT2 terminal block. The jumper is installed by default.
The gate can operate in two control modes: pulse and potential. Control mode is set by installing or
removing the jumper on Imp / Pot connector. If the jumper is installed, the gate operates in the
pulse control mode; if the jumper is removed, the gate operates in the potential control mode. The
jumper is installed by default. Algorithms of control signals sending for each control mode are given
in Appendix.
Connection of devices to control inputs is performed in accordance with wiring diagram, shown in
Fig. 11.
Note:
To generate high-level signal on all input contacts (Unlock A, Stop, Unlock B, Fire Alarm) 2
kOhm resistors connected to + 5 V power line are used.
Control element shall meet the following signal rquirements:
control element – relay contact:
minimum switching current .................................................................................... max. 2 mA
closed contact resistance
(including connection cable resistance) .......................................................... max. 300 Ohm
10

WMD-06 Motorized electromechanical swing gate
control element – open collector output circuit:
voltage at the closed contact
(low-level signal, at the control board input) .......................................................... max. 0.8 V
5.4.2 PASS outputs
PASS A (Pass A and Common contacts of XT1 terminal block), PASS B (Pass Вand Common
contacts of XT1 terminal block) outputs are basically a relay.
If the power is turned off, control board relays are normally open. In such case Common contact is
not connected to the negative terminal of the gate's power supply (see Fig. 8).
Figure 8. Output stages for PASS A, PASS B
If the status is normalized and the power is turned on, relay coil is energized and PASS A, PASS B
relay contacts are closed.
PASS A, PASS B relays activation/deactivation can be defined by activation/deactivation of
indicators that are installed near the related outputs on the control board (see Fig. 3).
Output stages for PASS A, PASS B relay contacts have the following signal specifications:
maximum switching voltage ........................................................................................... 42 V DC
maximum switching current .............................................................................................. 0.25 А
closed contact resistance..................................................................................... max. 0.15 Ohm
5.4.3 Outputs for external indication connection
Light A and Light B outputs are used for external indication connection and are basically relay
changeover contacts (see Fig. 9). Each output has full contact set on XT1 terminal block: normally
open (NO), normally closed (NC) and common (C). Connection is performed in accordance with
the wiring diagram given in Fig. 11.
Light A (Light B) relay is activated (meaning that its coil is energized) when the passage is open in
the direction A (B) and normalized when the passage is closed in the related direction.
Light A (Light B) relays activation/deactivation can be defined by activation/deactivation of
indicators that are installed by the near related outputs on the control board.
Output stages for Light A (Light B) are relay changeover contacts with the following signal
specifications:
maximum switching DC voltage .......................................................................................... 30 V
maximum switching AC voltage .......................................................................................... 42 V
maximum switching AC / DC ................................................................................................ 3 A
closed contact resistance.................................................................................... max. 0.15 Ohm
Figure 9. Output stages for Light A and Light B
11

Assembly and Operation Manual
5.5 Abnormal situations during gate operation
In a case of any impediment to the free rotation of the swing gate an automatic switching to
overload mode is provided. The mode is used to avoid damage to electromechanical elements due
to overheating.
If any obstacle impedes rotation of the swing panel, three attempts of rotation in the same direction
are made with 3 sec intervals. If the obstacle remains, the swing gate switches to overload mode.
Being in the overload mode the swing panel can rotate free ±90º that allows removing the obstacle.
In such case all three indicators on the RC panel are blinking, and a sound indication consisting of
three short audio signals is turned on each 20 sec.
The overload mode is switched off by rotating the swing panel into the “Closed” position manually
or by turning the power supply off and then on (in this case the gate will be set into home position
automatically).
6 MARKING AND PACKAGING
The swing gate has a marking label located inside the rotary post under the cover. The label
contains the trademark and contact details of the manufacturer, the manufacture date, voltage and
power consumption. To access to the marking take off the post cover by unscrewing three 3
screws using SW1.5 Allen wrench.
The swing gate in the standard package is packed in two boxes that protect it from being damaged
during transportation and storage. The box 1 contains gate post and RC panel, the box 2 contains
a swing panel. Boxes have the marking of the packed product and additional marking in
accordance with design documents and delivery set.
Dimensions, (L×W×H):
box 1 ................................................................................................................... 121×37×22 cm
box 2 for AGG-650 glass panel ............................................................................ 96×12×90 cm
box 2 for AGG-900 glass panel .......................................................................... 121×12×90 cm
Gross weight:
box 1 ......................................................................................................................... max. 36 kg
box 2 for AGG-650 swing panel ................................................................................ max. 28 kg
box 2 for AGG-900 swing panel ................................................................................ max. 35 kg
7 SAFETY REQUIREMENTS
7.1 Installation safety
Installation should be performed by qualified personnel only, in strict accordance with the Manual
and general electrical safety requirements for electrical and installation work.
Attention!
A
ll the connections should be performed only after the control unit is disconnected from
the power supply.
Only serviceable tools should be used.
Cables should be laid in accordance with electrical safety requirements.
Before first activation of the gate, check whether the installation and all connections are
performed correctly.
The installation of power supply unit shall be performed in accordance with general safety
requirements given in its operation manual.
7.2 Operation safety
Observe general safety requirements for use of electrical equipment.
Warning!
Do not use the swing gate in environment different from those given in Section 2.
Do not use the swing gate with power supply unit different from those given in Section 3.
Power supply unit shall be operated in accordance with general safety requirements given in its
operation manual.
12

WMD-06 Motorized electromechanical swing gate
8 ASSEMBLY AND INSTALLATION
Observe safety requirements given in the Section 7.1 during installation.
8.1 General recommendations
Proper installation is crucial to performance and serviceability of the swing gate. We advise you to
study this Manual before installation work and follow the instructions to the latter.
We recommend:
to mount the swing gate on a steady concrete foundation (grade 400 or higher), stone or
similar foundations of at least 150 mm thick.
to make sure the mounting foundation is horizontal and steady, so that all the mount points
lie in the same plane;
to employ reinforcing elements 450×450×200 mm, when installing on a less steady
foundation.
8.2 Tools and equipment required for installation
Use the following tools for the installation works:
1.2÷1.5kW hammer drill;
Ø16 mm hard-alloy drill bits for anchor bolts sleeves;
Phillips head screwdriver No.1;
SW1.5 Allen wrench;
S17 open-end wrench;
hobby knife;
level;
measuring tape 2 m.
Note:
The use of different tools is acceptable on condition that they do not reduce the quality of
installation works.
8.3 Appropriate cable length
Maximum acceptable length of RC panel / ACS controller cable .............................................. 30 m
Maximum acceptable length of power supply cable depends on its cross-section and shall be as
following:
for 1.5 mm2cross-section (AWG 15) ......................................................................max. 10 m
for 2.5 mm2cross-section (AWG 13) ......................................................................max. 20 m
8.4 Installation procedure
Attention!
The manufacturer shall not be liable for any damage caused in the result of improper
installation and declines any claims arising thereof in case if the installation is not in
compliance with the instructions provided in this Manual.
Item numbers in the installation sequence are given accordingly to Fig. 2, unless stated otherwise.
Wiring diagram is given in Fig. 11. Terminal blocks and jumpers positioning on the control board is
given in Fig. 3. Cables used for installation and their maximum lengths are set in Section 8.3.
Recommendations on surface preparation are given in Section 8.1. Follow this sequence during
gate installation:
1. Unpack the box with equipment, check carefully the delivery set according to Section 4.
Attention!
Don’t hold the gate by its cover (3) while moving it.
2. Mark and prepare the mounting holes in the floor as per Fig. 10 for anchors (9) to install the
gate post (If necessary, use the supplied template). Use Ø16 mm hard-alloy drill for hole
preparation. Drilling depth is 60 mm.
13

Assembly and Operation Manual
3. Install power supply unit in accordance with its operation manual.
Figure 10. Mounting hole layout
4. If it is necessary to lay power cables (13) and control cables (14) under the floor, prepare an
electrical conduit in the floor in the zone where cables are inserted into the gate post. The zone
positioning is given in Fig. 10.
5. Install anchors in the drilled holes in the floor, so that their sleeves would not obtrude out of the
floor surface.
6. Lay power cable and route the cable inside electrical conduit towards cable insertion zone. Pull
cables inside the fixed base (1) to the length appropriate for following installation on the control
board (6).
Attention!
Install and fix the gate post only when all cables are laid inside electrical conduit and the
gate post. Be careful until the post is not fixed, prevent it from falling down.
7. Install the gate post on anchors (9). Put it vertically by using a lever. Mounting pads may be
used. Vertical deviation shall not exceed 0.5º in two planes.
8. Remove the metal ring (5). Put a washer (11) on each anchor and fix the gate post with three
M10 nuts (10).
9. Connect power cable and control cable to XT1 and XT2 terminal blocks of the control board (6).
Put cables as shown in Fig. 3.
10. If needed, connect Fire Alarm emergency unlocking device. If the device is not connected, a
wire jumper shall be installed on Fire Alarm and GND contacts on XT2 terminal block.
11. If it is necessary, connect external indicators to XT1.2 and XT1.3 terminal blocks.
12. If it is necessary, change the position of jumpers on the control board.
13. Mount the glass panel according to Fig. 12. Fix the panel (6) on the rotary support (7) with
elements (1) – (5).
Attention!
Be careful while mounting the glass panel, prevent it from falling and hitting by metal
elements of the post. Due to the significant weight of the panel, it is recommended to put a
support under it during the assembly.
14. Install the metal ring (5). Put the gate housing (2) on the post moving it alongside the post axis
till it stops.
15. Install the cover (3) on the top having unscrewed the bolts (8) using SW 1.5 Allen wrench. Fix
the cover with the bolts.
When the installation is finished turn the gate on and test its operation in accordance with
Section 9.1.
14

WMD-06 Motorized electromechanical swing gate
Figure 11. Wiring diagram
Table 3. List of elements on the wiring diagram
Item Designation Comment
А1 Control board
А2Power supply unit of the swing gate +24V DC; 4А
А3Power supply unit of remote indicators
A4, A5Remote indicators 2 pcs
A6.1ACS controller input
A6.2ACS controller output
A7Device sending Fire Alarm (FA) emergency unlocking signal
A8 RC panel PERCo-H6/4
A9WRC device
1 Wire jumper. Installed when the Fire Alarm device (А7) is not
connected.
Installed on
default
Not included in standard delivery set.
15

Assembly and Operation Manual
Figure 12. Glass panel mounting
1 – M10 bolt; 2 – plastic bushing; 3 – M10 nut; 4 – spring washer; 5 – expanded washer;
6 – glass panel; 7 – rotary support
9 OPERATION
Observe safety requirements given in Section 7.2.
Warning!
Do not move any objects through the passageway whose dimensions exceed the width
of the passageway.
Do not hit elements of the swing gate so as to prevent their mechanical damage.
Do not dismantle or adjust mechanisms ensuring operation of the swing gate.
Do not use substances for cleaning of the swing gate that may cause mechanical
damage or corrosion of the surfaces.
9.1 Power-up
Attention!
Make sure that there are no obstacles in the rotation zone and passageway of the gate
before starting the power-up.
Perform the following actions in order:
1. Connect the power cable to the electric socket with voltage and frequency set in the certificate
of the power supply unit.
2. Turn the power supply unit on.
3. The swing gate will detect “Closed” position in automatic mode (see Figure 5).
4. In the pulse control mode the swing gate will switch to the “Always locked” mode, in the
potential mode the swing gate will switch to the “Locked in both directions” mode. The red
indicator located above the STOP button on the RC panel will turn on.
The swing gate is ready for operation.
16

WMD-06 Motorized electromechanical swing gate
9.2 Pulse control mode
Pulse control mode is used to operate the swing gate with RC panel, WRC devices and ACS
controllers that support this mode.
Operating modes setting is performed by applying a low-level signal or by closing Unlock A, Stop,
Unlock B contacts with GND contact of XT2 terminal block. In such case the duration of the control
signal shall be at least 100 ms. Algorithm of control signals is given in Appendix A. Indication of the
RC panel and the swing panel position are given in Table 4.
Table 4. Operating modes in pulse control mode (“Imp/Pot” jumper is installed)
Operating
mode
Operator’s actions on RC-
panel RC-panel indication Panel position
“Always
locked” Press the STOP button. Red indicator above the
STOP button
Panel is the in “Closed”
position and is locked
“Single
passage in
chosen
direction”
Press the LEFT or RIGHT
button corresponding to the
chosen passage direction.
Green indicator above the
button responsible for the
chosen passage direction,
red indicator above the
STOP button
Panel opens in chosen
direction for a single
passage
“Free
passage”
Press the STOP button and
the button corresponding to
the chosen passage
direction simultaneously
Green indicator above one
of the buttons responsible
for the passage direction
Panel opens in one of the
directions and remains in
this position until the mode
is changed.
The gate remains open for 4 sec. in the “Single passage in chosen direction” mode. Timing starts
after the swing panel rotates 85º. After that the swing panel moves to “Closed” position and locks,
the swing gate switches to the “Always locked” mode.
“Single passage in chosen direction” mode can be changed to “Free passage” mode in the same
direction or to “Always locked” mode; “Always free” mode can be changed to “Always locked”
mode only.
9.3 Potential control mode
Potential control mode is used to operate the swing gate with ACS controllers that support this
mode.
Operating modes setting is performed by holding a low-level signal at Unlock A, Stop and Unlock B
contacts and GND contact on the XT2 terminal block. Algorithm of control signals is given in
Appendix B. Indication of the RC panel and the swing panel position are given in Table 5.
Table 5. Operating modes in potential control mode (“Imp/Pot” jumper is removed)
Operating
mode Provided signal Operator’s actions
on RC panel
RC panel
indication Panel position
“Both
directions
closed”
Low-level – on Stop
contact,
high-level – on
Unlock A and
Unlock B contacts.
Press and hold the
STOP button
Red indicator
above the STOP
button
Panel switches to
the “Closed”
position
“Direction
open”
Low-level – on
Unlock A or Unlock B
contact
(corresponding to the
chosen passage
direction),
high-level – on other
contacts Stop,
Unlock B (Stop,
Unlock A).
Press and hold the
LEFT or RIGHT
button,
corresponding to
the chosen passage
direction
Green indicator
above the button
responsible for
the chosen
passage direction
Panel opens in
chosen direction
and remains so
until the low-level
signal on the
corresponding
contact is turned off
17

Assembly and Operation Manual
The duration of waiting period for “Direction open” mode is defined by the duration of control signal
on the contact related to opening direction of the swing panel.
9.4 Emergency situations
In case of fire, disasters and any other emergency situations it is necessary to provide emergency
exit to evacuate people. For example, BH-02 anti-panic rotary sections can be used as an
emergency exit.
The passageway of the swing gate can be used as an additional emergency exit. The construction
of the gate allows providing exit without use of any special keys or tools. Apply Fire Alarm control
signal to the control board. The swing panel will open automatically making the passage free
regardless of the set operating mode. Other control commands will be ignored. The opening
direction is defined by FireAlarmDir jumper on the control board. When the signal is turned off, the
swing panel moves to “Closed” position and locks.
Device sending Fire Alarm emergency unlocking signal is not included into standard delivery set.
Besides, the swing gate is basically a normally open device, meaning that in case of power failure
the swing panel can rotate manually ±90º, making the passage free.
9.5 Troubleshooting
Possible faults to be corrected by the user themselves are listed in Table 6. In an unlikely event of
other faults please consult the PERCo Technical Support Department.
Table 6. Troubleshooting
Fault Possible cause Remedy
When powered-up,
RC-panel indication
does not work
No supply voltage on
control board
De-energize power supply unit. Remove the cover
and housing of the gate. Check the power cable
and its connection to the XT1 terminal block.
The gate cannot
operate in one of the
directions, RC-panel
indication is on
Control signal of
chosen direction is
not applied to the
control board
De-energize power supply unit. Remove the cover
and housing of the gate. Check the cable of RC
panel / WRC device / ACS controller and its
connection to the XT2 terminal block
10 TRANSPORTATION AND STORAGE
The swing gate in the original package should be transported only in closed freight containers or
other closed type cargo transport units.
During storage and transportation boxes with swing gate posts can be stacked no more than 2
layers high. Stacking of boxes with glass panels is not allowed.
The swing gate should be stored in dry indoor facilities at ambient temperatures from –40°C to
+50°C and at relative air humidity of up to 98% at +25°С.
After transportation or storage at below-zero temperatures or high air humidity, the swing gate
should be kept unpacked for minimum 24 hours under normal climate conditions corresponding to
operation conditions.
11 MAINTENANCE
Technical maintenance of the swing gate should be performed only at PERCo service center.
We recommend using liquid non-abrasive cleansers containing ammonia to clean a swing gate
post and a glass panel when dirty.
18

WMD-06 Motorized electromechanical swing gate
APPENDIX A. Control signal algorithm in pulse control mode
The command is a signal active front (signal transfer from the high level to the low level) at any of
the contacts at presence of the corresponding signal levels at the other contacts.
Note:
RC panel:
active front – pressing of the relevant button,
low level – the relevant button has been pressed,
high level – the relevant button has not been pressed.
The following commands can be formed by sending a low-level signal to Unlock A, Stop and
Unlock Bcontacts and GND contact on the XT2 terminal block relative to the GND contact:
Always locked (locked for entry and exit) - active front is at the contact Stop while there is a high
level at the contacts Unlock Aand Unlock B. Both passage directions are locked at this command.
Single passage in the direction А(open for passage of one person in the direction А) - active
front is at the contact Unlock Awhile there is a high level at the contacts Stop and Unlock B. At this
command the passage direction Аopens either for 5 sec. or until the passage has been made in
this direction or until the “Always locked” command, and the status of the passage direction Вdoes
not change at that. The command is ignored if at the moment of its receipt the status of the
passage direction Аis “Always free”.
Single passage in the direction В(open for passage of one person in the direction В) - active
front is at the contact Unlock Bwhile there is a high level at the contacts Stop and Unlock A. At this
command the passage direction B opens either for 5 sec. or until the passage has been effected in
this direction or until the command “Always locked”, and the status of the passage direction A does
not change. The command is ignored if at the moment of its receipt the status of passage direction
B is “Always free”.
Free passage in the direction А(open for free passage in the direction А) - active front is at the
contact Unlock A while there is a low level at the contact Stop and a high level at the contact Unlock
B, or active front is at the contact Stop while there is a low level at the contact Unlock Aand a high
level at the contact Unlock B. At this command the passage direction Аopens until the command
“Always locked” is received; the status of the passage direction Вdoes not change at that.
Free passage in the direction В(open for free passage in the direction В) - active front is at the
contact Unlock Bwhile there is a low level at the contact Stop and a high level at the contact Unlock
A, or active front is at the contact Stop while there is a low level at the contact Unlock Band a high
level at contact Unlock A. At this command the passage direction Вopens until the “Always locked”
command is received; the status of the passage direction Аdoes not change at that.
APPENDIX B. Control signal algorithm in potential control mode
Note:
For ACS controller outputs:
high level – either contacts of the output relay are broken or the output transistor is closed,
low level – either contacts of the output relay are closed or the output transistor is open.
Both directions are locked (locked for entry and exit) - there is a high level at the contacts
Unlock Aand Unlock B, or a low level at the contact Stop. The both passage directions are locked
at this command.
The direction Аis open (open for passage in the direction А)- there is a low level at the contact
Unlock Awhile a high level is present at the contacts Stop and Unlock B. At this command the
direction Аis opened till the low-level signal removal from the contact Unlock Аor until the command
“Both directions locked” is received. The status of the direction Вdoes not change at that.
The direction Вis open (open for passage in the direction В)- there is a low level at the contact
Unlock Вwhile there is a high level at the contacts Stop and Unlock А. At this command the direction
B is opened till the low-level signal removal from the contact Unlock Bor until the command “Both
directions locked” is received. The status of the direction A does not change at that.
19