TECHNICAL SPECIFICATIONS
U2W2E
Via Pianelli,38 - 28017 S.Maurizio d’Opaglio (NO) ITALY Tel. +39 0322 96217 - Fax. +39 0322 96546 - www.pettinaroli.com
STE0135 rev.00 05/10/2015
Wireless control unit 868MHz
U2W2E 230V 4/8/12 zones ETHERNET
The wireless control unit U2W2E - 230V - 868 MHz is smart
base station with no wires to manage room thermostats
(T2WB and/or T2WBD) and actuators (A542O2) in order to set
and keep the temperature in different rooms.
Thewireless control unit U2W2E - 230V - 868 MHz can deliver
the power to move actuators (A542O2) and it can install a
bidirectional communication with thermostats, throughout
the most recent 868 MHz radio technology.
This unit records and uses an important amount of measured
data to control singularly the room temperature, in order to
guarantee the maximum comfort.
The standard version is equipped with a technological
software, able to comply every management requirement with
current and next heating systems have; since this branch looks
constantly ahead, every software and settings update can be
done by inserting a MicroSD memory card. MicroSD slot is on
the bottom and the card is optional.
The wireless control unit U2W2E - 230V - 868 MHz has a RJ45
port and an integrated web server to manage and set remotely
via Internet with PC/smartphone/tablet.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
TECHNICAL FEATURES
Wireless communication between room thermostat
(T2WB or T2WBD) and the wireless control unit U2W2E -
230V)
Technology 868 MHz
Thermostat status indication
“Antifreeze” function
Heating and cooling systems adjustment function for single
rooms, managing up to 12 zones (according to version)
Management of maximum 18 actuators and 12 room
thermostats (according to the control unit version), a
pump/boiler, CO signal generator, a dry bulb humidity
sensor and external clock
System setting by MicroSD card
RJ45 port to manage and set via Internet with
PC/smartphone/tablet.
GENERAL INFORMATION
Name
U2W204Eto manage maximum 4 room thermostats (T2WB or
T2WBD) –4 zones
U2W208Eto manage maximum 8 room thermostats (T2WB or
T2WBD) –8 zones
U2W212Eto manage maximum 12 room thermostats (T2WB
or T2WBD) –12 zones
Each room thermostat can drive several zones.
Packaging content
1 x wireless control unit U2W2E - 230V 868 MHz
1 x instruction manual
1 x fixing metallic bar
Accessories (optional)
External antenna U2WA –it extends the radio signal range of
the control unit
Signal repeater U2WR –it increases the unit control radio
range
Humidity sensor U2DP or U2DPRS –it measures humidity and
dew point for heating/cooling floor applications
USE
The wireless control unit U2W2E - 230V is used in conditioning
systems for new buildings as well as renovations like houses,
offices, stores, etc…
Using the wireless control unit U2W2E - 230V the installation
time can be consistently reduced; that is a great benefit for
installers. The wireless control unit U2W2E - 230V is often
installed in manifold wall boxes. This product is developed for
the connection of 4-8-12 room thermostat (T2WB or T2WBD)
and 18 actuators (A542O2).
Wireless room thermostat installation (T2WB or T2WBD) is
very easy because no wiring is needed. The free tool
connection and the clear color codification allow to quickly link
wires (actuators, boiler, pump, etc.). All wires are placed in
specific guides, in order to have a clear and orderly
arrangement and a fast installation of the wireless control unit
U2W2E - 230V.
‘’Antifreeze’’ function
Every actuator outlet has protection function against freezing,
independently of the operation mode. As soon as the set
antifreeze temperature is overpassed (5 … 10°C), actuators
A542O2 of the corresponding heating zone are switched on,
until reaching the safety set temperature. “Antifreeze”
temperature can be set by the MicroSD card.
Pump protection function
The pump is periodically activated (default intervals are set) to
avoid any damage due to too long stops. During that time, the
LED pump is on.
Valves protection function
When valves are closed for long time (for example, out of the
heating season), they are cyclically open in every heated zone
to avoid mechanic blocks.
Monitoring the dew point
If the system has a dew point sensor (to purchase separately)
and humidity is measured, the valves of all circuits are closed
to avoid damages to surfaces because of the moisture. Dew
point sensor input is taken into account just in cooling mode.
Safety temperature limitation
If a temperature limiter (optional) is installed, when the critical
temperature (previously set) is overpassed, valves shut down
and they preserve fragile surface of floors.

TECHNICAL SPECIFICATIONS
U2W2E
Via Pianelli,38 - 28017 S.Maurizio d’Opaglio (NO) ITALY Tel. +39 0322 96217 - Fax. +39 0322 96546 - www.pettinaroli.com
STE0135 rev.00 05/10/2015
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Connection of many control units
In case of use of many control units in a conditioning system,
up to 7 control unit can be paired (Pairing), enabling global
parameters exchange. The connection is done via radio or by
means of BUS system (syBUS). The radio range has to be
followed in order to pair units wireless. If the range is not
enough, control units must be connected through the wired
system syBUS. The communication type is the master/slave
principle. All messages and actions are exchanged among
control units. The master unit monitors in a centralized way the
following functions:
CO input/output (if the pilot function is activated)
Boiler output
Pump output
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
CONNECTION OF ETHERNET
Integration into the home network
Quick and easy implementation into the home network
System interface for creation of superior control system
Control via PC / Smartphone
Comfortable parameterization and initial setting of the
system via PC, smartphone or tablet
Maximum comfort felt in every room
Maximum comfort due to the web application
Intuitive web interface for a clear overview
Complete control over all functions
The connection into the can be carried out by means of an
Ethernet cable, linking the control unit to the router or directly
to the PC/laptop.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
APPROVALS

TECHNICAL SPECIFICATIONS
U2W2E
Via Pianelli,38 - 28017 S.Maurizio d’Opaglio (NO) ITALY Tel. +39 0322 96217 - Fax. +39 0322 96546 - www.pettinaroli.com
STE0135 rev.00 05/10/2015
TECHNICAL DATA
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
DIMENSIONS
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
PACKAGE CONTENT
Type
U2W404E
U2W408E
U2W412E
Supply voltage
230 V AC, ±15% / 50Hz
Max. power consumption
50 W
Fuse
5 x 20 mm, T4AH
Max. n. of room thermostat
4
8
12
Max. n. of actuators
2 X 2 + 2 X 1
4 X 2 + 4 X 1
6 X 2 + 6X 1
Max. supply power for actuators
24W (2x 2W or 8x3 resp. or 18 x 1W)
Max. switching power
1A/zone
1A/heating zone
Frequency
868 MHZ-band
Radiated power
<10mW
Range
Max. 25 m
Standard and regulations
EN60730-1 / EN60730-2-9
Dimensions (mm) WxHxD
306x75x52
371x75x52
436x75x52
Protection class
III
Protection degree
IP20
Environment temperature
da 0 a + 60° C
Storage temperature
da -25° a + 70° C
Air humidity
Max. 80%
Solid wire
0,5 –1 mm2
Flexible wire
1 - 1.5 mm2
Ethernet connection
RJ45
Weight
500 g
650 g
760 g

TECHNICAL SPECIFICATIONS
U2W2E
Via Pianelli,38 - 28017 S.Maurizio d’Opaglio (NO) ITALY Tel. +39 0322 96217 - Fax. +39 0322 96546 - www.pettinaroli.com
STE0135 rev.00 05/10/2015
INSTALLATION
ELETTRIC CONNECTION
1. Temperature limiter
2. Pump
3. Boiler
4. ECO
5. Change-over
6. Humidity sensor
7. Actuators

TECHNICAL SPECIFICATIONS
U2W2E
Via Pianelli,38 - 28017 S.Maurizio d’Opaglio (NO) ITALY Tel. +39 0322 96217 - Fax. +39 0322 96546 - www.pettinaroli.com
STE0135 rev.00 05/10/2015
SYSTEM BUS CONNECTION
PROTECTIVE COVER CLOSING
FUSE CHANGING

TECHNICAL SPECIFICATIONS
U2W2E
Via Pianelli,38 - 28017 S.Maurizio d’Opaglio (NO) ITALY Tel. +39 0322 96217 - Fax. +39 0322 96546 - www.pettinaroli.com
STE0135 rev.00 05/10/2015
COMMISSIONING
EXTERNAL TOOLS CONNECTION
(*) Not included in the package
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
ETHERNET CONNECTION SETTING
The integration can be carried out by means of an Ethernet cable, linking the control unit to the router or directly to the PC/laptop.
Set-up in the home network
Open the router menu (see manual of the respective device) entering its URL in the address bar in the web browser (Internet
Explorer, Firefox, Google Chrome)
Open an overview of all devices in the network.
Through the MAC address (see type sign beside the RJ45 port) in order to find out the IP address allocated to the wireless control
unit.
Note the IP address of the control unit and enter it into the address bar of the web browser in order to open the web interface.
Save this address.
Direct connection to PC/laptop
Open the network settings in the PC/laptop and manually assign the IP address IP 192.168.100.1 as well as the subnet mask
255.255.0.0 to the PC.
Access to the web interface can be gained by entering the IP 192.168.100.100 in the address bar of your web browser.
You can find further information on the set-up as well on the worldwide Internet access under www.ezr-home.de.
This manual suits for next models
3
Table of contents
Popular Control Unit manuals by other brands

CLA-VAL
CLA-VAL 58-01 Installation, operation and maintenance

Vaillant
Vaillant VWZ AI operating instructions

Cooper Security
Cooper Security i-On 40 Installation and user guide

Viessmann
Viessmann VITOTRONIC 100 Installation and service instructions

AEM
AEM VCU200 user guide

Middle Atlantic
Middle Atlantic MPR-A Series instruction sheet