Philips GearUnits ECB330 User manual

12NC
Versiondate: /201
Data subject to change without notice
Printed in Poland
www.philips.com/lighting
4427 100 66681
19/01 2
1. Not applicable for outdoor use.
2. l.
3. Ignitor on the luminaire, not on the gear unit. No limitation of distance between lamp-gear unit.
4. Ignitor on the gear unit.
5. Distance between lamp-gear unit limited to 10m for SON-T 400/600W and 26m for SON-T 1000W.
7. Gear unit suitable also for floodlights equipped with electronic hot restrike ignitor (HRE).
8. Fuse optional, applies as 1-phase protection for 230/240V versions and 2-phase protection for 360-430V versions
amp currents are approximate data. For exact data refer to the lamp data sheet.
.
9. L
Value for two systems in tota
6. Distance between lamp-gear unit limited to 1500m for HPI-TP 400W, 350m for HPI-TP 1000W
and 1200m for HPI-TP 2000W.
MAINS
~50Hz
MIN Ta °CM TaAX C°
Philips GearUnits ECB330/ECP330
Mounting instructions
Instructions de montage
Montageanletiung
Montage instruktic
Instruzioni di montaggio
Instrucciones de montaje
Instruções de montagem
Monteringsinstruktioner
Monteringsvejledning
Kokoonpano- ja kiinnitysohjeet
Montaj yönergesi
Szerelési utasítások
Instrukcja monta uż
Návod k montázi
IEC
EN61347
IP20
ECB330
IP65
ECP330
2 x HPI-TP 400W 230/240V 12 -30 n/a145 n/a198624,327,823,8 2 x gG8A - - x6
2 x SON-T 400W 230/240V 12 -30 n/a145 n/a187824,427,224,5 2 x gG8A x x5-
2 x SON-T 600W 230/240V 13 -30 n/a145 n/a1128426,229,825,8 2 x gG16A x - -
2 x SON-T 600W 230V 13 -30 n/a145 n/a1128426,229,825,8 2 x gG16A - x5-
2 x SON-T 600W 240V 13 -30 n/a145 n/a1128426,229,825,8 2 x gG16A - x5-
HPI-TP 1000W 230/240V 15 -30 n/a145 n/a11051 5,3 8,7 8,25 gG16A - - x6
HPI-TP 2000W 380/400/415V 19,5 -30 n/a145 n/a12059 6,0 10,9 9,1 gG16A - - x6
MHN-FC 1000W 230/240V 16 -30 n/a145 n/a11110 6,0 8,0 8,9 gG16A x - -
MHN-FC 2000W 360/380/400/415V 20,5 -30 n/a145 n/a12158 5,3 8,2 9,6 gG16A x - -
MHN-LA 1000W 230/240V 16 -30 n/a145 n/a11110 6,0 8,0 9,3 gG16A x7- -
MHN-LA 2000W 360/380/400/415V 20,5 -30 n/a145 n/a12166 5,3 8,2 9,6 gG16A x - -
MHN-SE 2000W 380/400/415/430V 22 -30 n/a145 n/a12120 5,9 8,0 11,6 gG16A x7- -
SON-T 1000W 230/240V 16 -30 n/a145 n/a11075 5,4 7,3 10,3 gG16A x x5-
SON-T 600W 230/240V 7,5 -30 n/a145 n/a1642 3,1 4,9 5,8 gG8A x - -
SON-T 600W 230V 7,5 -30 n/a145 n/a1642 3,1 4,9 5,8 gG8A - x5-
SON-T 600W 240V 7,5 -30 n/a145 n/a1642 3,1 4,9 5,8 gG8A - x5-
2 x HPI-TP 400W 230/240V 18 -30 -30 45 55 98624,327,823,8 2 x gG8A - - x6
2 x SON-T 400W 230/240V 18 -30 -30 45 55 87824,427,224,5 2 x gG8A x x5-
2 x SON-T 600W 230/240V 19 -30 -30 45 55 128426,229,825,8 2 x gG16A x - -
2 x SON-T 600W 230V 19 -30 -30 45 55 128426,229,825,8 2 x gG16A - x5-
2 x SON-T 600W 240V 19 -30 -30 45 55 128426,229,825,8 2 x gG16A - x5-
HPI-TP 1000W 230/240V 19 -30 -30 45 55 1051 5,3 8,7 8,25 gG16A - - x6
HPI-TP 2000W 380/400/415V 24 -30 -30 45 55 2059 6,0 10,9 9,1 gG16A - - x6
MHN-FC 1000W 230/240V 20,5 -30 -30 45 55 1110 6,0 8,0 8,9 gG16A x - -
MHN-FC 2000W 360/380/400/415V 25 -30 -30 45 55 2158 5,3 8,2 9,6 gG16A x - -
MHN-LA 1000W 230/240V 20,5 -30 -30 45 55 1110 6,0 8,0 9,3 gG16A x7- -
MHN-LA 2000W 360/380/400/415V 25 -30 -30 45 55 2166 5,3 8,2 9,6 gG16A x - -
MHN-SE 2000W 380/400/415/430V 26,5 -30 -30 45 55 2120 5,9 8,0 11,6 gG16A x7- -
SON-T 1000W 230/240V 20,5 -30 -30 45 55 1075 5,4 7,3 10,3 gG16A x x5-
SON-T 600W 230/240V 12 -30 -30 45 55 642 3,1 4,9 5,8 gG8A x - -
SON-T 600W 230V 12 -30 -30 45 55 642 3,1 4,9 5,8 gG8A - x5-
SON-T 600W 240V 12 -30 -30 45 55 642 3,1 4,9 5,8 gG8A - x5-
ECB330
ECP330
ECB330:
2 x SON-T 600W 230V
2 x SON-T 600W 240V
L1 L2 N
La2 N2
Lamp2
La1 N1
Lamp1
Mains
Lamp 1 & 2
Ballast tap selection Lamp
ECB330 & ECP330:
MHN-SE 2000W
380/400/415/430V
L1 L2 N
430V 415V 400V 380V 1 2
Mains
Lamp
430V 415V 400V 380V
Ballast tap
selection
ECB330 & ECP330:
MHN-FC 1000W
MHN-LA 1000W
HPI-T 1000W
SON-T 1000W
230/240V
Ballast tap selection Lamp
240V 230V La N
L1 L2 N
Mains
Lamp
240V 230V
Ballast tap
selection
ECP330:
2 x SON-T 400W
2 x SON-T 600W
2 x HPI-T 400W
2 x HPI-T 600W
230/240V
L1 L2 N N
Mains
L1 L2 N
Mains
ECP330:
2 x SON-T 600W 230V
2 x SON-T 600W 240V
La2 N2
Lamp2
La1 N1
Lamp1
Lamp 1 & 2
Ballast 1 Ballast 2
Tap selection
240V 230V 240V 230V
Ballast tap
selection
240V 230V 240V 230V
Ballast 1
La1 La2
Lamp
Lamp 1 & 2
Ballast 2
I
GB
F
D
NL
E
S
Total light output is directly dependant on Gear Unit main voltage.
Use the correct ballast tap according the actual main voltage.
Le flux lumineux de la lampe est directement dépendant de la tension d'alimentation de la platine.
Sélectionner la prise ballast en fonction de la tension d'alimentation.
Der abgegebene Lichtstrom haengt von der anliegenden Netzspannung ab.
Klemmenanschluss am Vorschaltgerät entsprechend der anliegenden Netzspannung
De totale licht opbrengst is direkt afhankelijk van het voltage van de platine.
Gebruik de juiste tap van de ballast afhankelijk van de net spanning.
Il fluxo della lampada è directtaménte legato a la tensióne d'alimentazione della unitá elèttrica.
Utilzzare il collegamento a la tensione d'alimentazione guista.
El flujo de la lampara depende del voltage de alimentación.
Utilize la conección correcta segon el voltage de alimentación.
Ljusflödet är beroende på reaktorns driftspänning.
Anslut reaktorn för rätt nätspänning där altenativ finns.
ECB330:
SON-T 600W 230V
SON-T 600W 240V
La N
Lamp
L1 L2 N
Mains
Lamp
L1 L2 L3
415V 400V 380V 360V
Ballast tap selection
1 2
Lamp
Mains
Lamp
ECB330 & ECP330:
MHN-FC 2000W
MHN-LA 2000W
360/380/400/415V
415V 400V 380V 360V
Ballast tap
selection
L1 L2 N
Ballast tap selection Lamp
ECB330 & ECP330:
HPI-T 2000W
380/400/415V
415V 400V 380V 1 2
Mains
Lamp
415V 400V 380V
Ballast tap
selection
ECB330:
2 x SON-T 400W
2 x SON-T 600W
2 x HPI-T 400W
2 x HPI-T 600W
230/240V
L1 L2 N N
Mains
L1 N
Mains
ECP330:
SON-T 600W 230V
SON-T 600W 240V
La N
Lamp
Lamp
240V 230V 240V 230V
Ballast 1 Ballast 2
Tap selection
240V 230V 240V 230V
Ballast tap
selection
Ballast 1
1 2
Lamp
Ballast 2 Lamp 1 & 2
Disconnect before servicing Togliere tensione prima di fare manutencione
Mettre hors tension avant intervention Desconectar antes de manipular
Offnen nur voor onderhoud Bryt str men f re lampbyte
Demonteren voor onderhoud
öm ö
I [A]inrush
30[s]
I
[A]
nom
P
[W]
IK10
ECP330
I
[A]
nom 9FUSE 8
(10x38)
IGNITOR
SI3
IGNITOR
SP4
IGNITOR
PA4

500
O182
460
126
145
472
121
136,3
28
108
O14/8,5
O6,3(x4)
O14/8,5
12,4
36,4
47
O215
163,4
179,4
136
418
535
496,5
43
O12/6,3(x4)
EC 33P 0
EC 330B
3
3,0Nm
EC 33P 0
8 50
Max mains wire diameter 16 mm2
Max lamp wire diameter 4 mm2
D
min(mm)
10 14
PG 16 (M20)
PG 21 (M25) 13 18
D
Recom. Cap
Tightening
Torque (nm)
3,3
5,0
D
min(mm)
EC 330B
PZ2
8 50
Max mains wire diameter 16 mm2
Max lamp wire diameter 4 mm2
-
x1
x3 x2
Fuse optional
Fuse optional
This manual suits for next models
1
Popular Industrial Equipment manuals by other brands

Wilo
Wilo SiBoost Smart Helix V Series Installation and operating instructions

morse
morse 185A Operator's manual

Matsing
Matsing MS-12C45 instruction manual

DeWalt
DeWalt DXCM072-0030 instruction manual

Degelman
Degelman 46/5700 Series Operator's Manual/Parts Catalog

Dungs
Dungs FRM-NOC 100 Series instruction manual