Photonic Universe MT11 User manual

REMOTE
METER
Model: MT11
INSTRUCTION MANUAL
For use with DM series dual battery MPPT solar charge controllers


Contents
1. Important Safety Instructions ............................................................1
2. Overview...........................................................................................2
3. Product Components ........................................................................3
4. Installation ........................................................................................4
4.1 Mounting Frame (optional accessory, included) ........................4
4.2 Wall installation steps ...............................................................5
4.3 Surface mounting steps ............................................................7
5. Product Features ..............................................................................8
5.1 Front View ................................................................................8
5.2 Rear View.................................................................................9
6. Display and Operation ....................................................................11
6.1 LCD display ............................................................................11
6.2 Auto global view mode............................................................ 12
6.3 Temperature units...................................................................14
6.4 Clear the generated energy ....................................................14
6.5 Battery type ............................................................................15
6.6 Fault indication .......................................................................19
7. Technical Specifications..................................................................20

1
1.
Important Safety Instructions
SAVE THESE INSTRUCTIONS:
This manual contains important safety, installation and operating
instruction for the remote meter.
General safety information
Please inspect the MT11 thoroughly after it is delivered. If there is
any damage, document this with photos and contact the shipping
company or seller for assistance.
Please read this manual carefully before installing the product and
pay close attention to the safety information.
Keep the MT11 away from rain, dust, vibrations, corrosive gas and
intense electromagnetic interference.
Do not allow water to enter the remote meter.
There are no user serviceable parts inside the remote meter. Do not
disassemble or attempt to repair it.
The MT11 is only compatible with DM series charge controllers.
Please confirm before purchase and installation.

2
2. Overview
The MT11 remote meter is an accessory which is compatible with
the DuoRacer (DM series) MPPT solar controller. It can monitor the
running data and working status of the controller, set the battery type
and temperature units, and reset the generated energy counter.
Features:
Automatically identify and display the type, model and relevant
parameter data of compatible controllers.
Real-time display of the operational data and working status of the
connected device in digital, graphical and textual forms by a large-
screen multifunctional LCD.
Three touch buttons are quick and easy to operate.
No need for external power supply. The connected charge controller
supplies the power for MT11.
The meter can browse the controller’s parameters, set the
battery type and temperature unit, and reset the generated
energy counter.
Real-time display of fault information of the connected devices.
Long communication distance via RS485.

3
3. Product Components
Remote meter MT11
5m communication cable
(Model: CC-RS485-RS485-3.81-4P-500)
Optional Mounting Frame

4
4. Installation
4.1 Mounting Frame (optional accessory, included)

5
Mechanical parameter
Measurement
Overall dimensions
114 x 114 x 44.41mm
Mounting dimensions
88.6 x 88.6mm
Terminal
Φ5
4.2 Wall installation steps
Step 1: Mark and drill screw holes to match the mounting dimensions
of the base, and insert the plastic expansion bolts.
Step 2: Use four PA4.2×32 self-tapping screws to fix the frame to the
wall.
Step 3: Remove the decorative shell.
Step 4: Use four M4×8 pan head screws to mount the MT11 screen
onto the frame.
Step 5: Install the decorative shell over the screen.

6

7
4.3 Surface mounting steps
Step 1: Mark and cut an appropriately-sized hole in the surface for the
cable and rear of the screen.
Step 2: Mark and drill screw holes based on the mounting dimensions.
Step 3: Remove the decorative shell.
Step 4: Use four M4×8 cross recessed pan head screws with M4 nuts
to mount the MT11 screen onto the surface.
Step 5: Install the decorative shell.
NOTE: Consider the plugging/unplugging space and the length of
the cable during installation to ensure the cable will fit.

8
5. Product Features
5.1 Front View
LCD display screen
Remote meter operation interface. Refer to chapter 6 for details of
display and operation.
Buttons
The meter buttons include two function buttons and one switch button.
Press the button
1. PV array parameters
2. Storage battery parameters

9
3. Browse the starter battery parameters
automatically ( )
Press the button
1. Browse the PV array parameters
2. Browse the storage battery
parameters
3. Browse the starter battery parameters
Press the button
and hold for 5s
Temperature units/Battery type
Press the button
Turn the meter ON
Press the button
and hold for 5s
Turn the meter OFF
5.2 Rear View

10
RS485 communication port
Used to connect to the solar controller which, provides power and
data to the MT11.
Communication cable models
CC-RS485-RS485-3.81-4P-500 (Included, 5m length)
CC-RS485-RS485-3.81-4P-1000 (Optional, 10m length)
CC-RS485-RS485-3.81-4P-2000 (Optional, 20m length)
Pins definition
PIN
Definition
1
DC5V
2
RS-485-B
3
RS-485-A
4
GND

11
6. Display and Operation
6.1 LCD display
Icon Instruction Icon Instruction
BATT1 battery capacity
level
①
0~12%
BATT2 battery capacity
level
①
0~12%
BATT1 battery capacity
level
①
13%~35%
BATT2 battery capacity
level
①
13%~35%
BATT1 battery capacity
level
①
36%~61%
BATT2 battery capacity
level
①
36%~61%
BATT1 battery capacity
level
①
62%~86%
BATT2 battery capacity
level
①
62%~86%

12
BATT1 battery capacity
level
①
87%~100%
BATT2 battery capacity
level
①
87%~100%
Day
PV array
Night
BATT1 charging icon
Display the parameters
of the PV array
BATT2 charging icon
Display the parameters
of BATT1
BATT1 temperature
parameters
Display the parameters
of BATT2
AES signal icon
Setting icon
Battery type icon
Auto global view sign
Minimum voltage icon
Fault icon
Maximum voltage icon
①Battery power capacity is calculated by a linear relationship between the
disconnect voltage and float charging voltage.
6.2 Auto global view mode
Operation:
Step 1: Press the button, will appear.
Step 2: Press the button, select the . The display will now
automatically loop through all parameters.

13
Display Loop: PV voltage →PV current →PV power→Battery power →BATT1
voltage →BATT1 current →Max. BATT1 voltage →Min.BATT1 voltage →BATT1
temperature →BATT1 battery type →BATT2 voltage →BATT2 current →Max. BATT1
voltage →Min.BATT2 voltage →PV voltage

14
6.3 Temperature units
Operation:
Step 1: Press the button under the battery temperature interface.
Step 2: Press the button to select the temperature unit.
Step 3: Press the button to set successfully.
6.4 Clear the generated energy
Press the and button and hold for 5s to clear the generated
energy.

15
6.5 Battery type
1)Operation:
Step 1: Press the button and hold for 5s under the battery type interface.
Step 2: Press the button when the battery type interface is flashing.
Step 3: Press the button to confirm the battery type.
2) Battery type
BATT1 12V Sealed
BATT1 24V Sealed
BATT1 12V Gel
BATT1 24V Gel
BATT1 12V Flooded
BATT1 24V Flooded
LiFePO4 (4S)
LiFePO4 (8S)
Li-NiCoMn (3S)
Li-NiCoMn (6S)
User
NOTE: The battery voltage is set as default and not changeable when
selecting the default battery type. Please change to “User” battery type
before adjusting the battery voltage. Set the voltage of the “User” battery
type via PC software only.

16
1) Lead-acid Battery Control Voltage Parameters
The parameters below are for a 12V system at 25 ºC. Please double the
values in a 24V system.
Battery type
Voltage parameter
Sealed Gel Flooded
User
Over Voltage Disconnect Voltage
16.0V
16.0V
16.0V
9~17V
Charging Limit Voltage
15.0V
15.0V
15.0V
9~17V
Over Voltage Reconnect Voltage
15.0V
15.0V
15.0V
9~17V
Equalize Charging Voltage
14.6V
→
14.8V
9~17V
Boost Charging Voltage
14.4V
14.2V
14.6V
9~17V
Float Charging Voltage
13.8V
13.8V
13.8V
9~17V
Boost Reconnect Charging Voltage
13.2V
13.2V
13.2V
9~17V
Low Voltage Reconnect Voltage
12.6V
12.6V
12.6V
9~17V
Under Voltage Warning Reconnect
Voltage
12.2V 12.2V 12.2V 9~17V
Under Volt. Warning Voltage
12.0V
12.0V
12.0V
9~17V
Low Volt. Disconnect Voltage
11.1V
11.1V
11.1V
9~17V
Discharging Limit Voltage
10.6V
10.6V
10.6V
9~17V
Equalize Duration (min.)
120
→
120
0~180
Boost Duration (min.) 120 120 120 10~180
NOTE:
1) When the battery type is sealed, gel, or flooded, the adjustable range of
equalize duration is 0 to 180min, and boost duration is 10 to 180min.
2) The following rules must be observed when modifying the value of the
parameters in User battery type (factory default value is the same as sealed
type):

17
A. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize
Charging Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage >
Boost Reconnect Charging Voltage.
B. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥
Discharging Limit Voltage.
D. Under Voltage Warning Reconnect Voltage > Under Voltage Warning
Voltage ≥ Discharging Limit Voltage.
Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.
2) Lithium Battery Control Voltage Parameters
The parameters below are for a 12V system at 25 ºC; please double the
values in a 24V system.
Battery type
Voltage parameter
LiFePO4
(4S)
Li-NiCoMn
(3S) User
Over Voltage Disconnect Voltage
15.6V
13.5V
9~17V
Charging Limit Voltage
14.6V
12.6V
9~17V
Over Voltage Reconnect Voltage
14.5V
12.5V
9~17V
Equalize Charging Voltage
14.5V
12.5V
9~17V
Boost Charging Voltage
14.5V
12.5V
9~17V
Float Charging Voltage
13.8V
12.2V
9~17V
Boost Reconnect Charging
Voltage
13.2V 12.1V 9~17V
Low Voltage Reconnect Voltage
12.4V
10.5V
9~17V
Under Voltage Warning Reconnect
Voltage
12.5V 11.0V 9~17V
Table of contents
Other Photonic Universe Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Excelitas Technologies
Excelitas Technologies OmniCure LM2011 Series user guide

SATO KEIRYOKI
SATO KEIRYOKI WVAT6D0-3-10 instruction manual

South
South N6+ Series Operation manual

Autonics
Autonics KN-2000W Series product manual

Advanced Energy Industries
Advanced Energy Industries LumaSense Technologies E2T Quasar 2 Series quick start guide

Decagon Devices
Decagon Devices KD2 Pro Operator's manual