PICOTE New Boy EPS133TDE Use and care manual

These instrucons are for your personal safety. Always ensure that you
have read and understood these instrucons before using the machinery.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
PICOTE
GENERATOR
400V
GENERATOR
OPERATION
& SAFETY
MANUAL

PICOTE GENERATOR 400V
TOPIC PAGE
Safety Warnings & Symbols, Safety Requirements 3
General Informaon 8
Technical Data 8
Main Components 9
Descripon of Control Panel 10
Electrical Diagram 11
Noise Levels & Emissions 12
CE Declaraon of Conformity 12
Starng & Using the Generator 13
Charging the Generator Set 13
Stopping the Generator Set 14
Cooling 14
Protecons 14
Residual Current Device 14
User Safety 14
Connecng The Earth Pin 15
Electrical Cables 16
Spare Parts 16
Maintenance 16
Transport & Storage 17
Troubleshoong Flowchart 18
Warranty Policy & Procedure 19
Table of Contents
www.picotesoluons.com Picote Soluons Oy Ltd
2
To watch praccal demonstraon videos, or to download an electronic copy of these Instrucons, please
visit www.picotesoluons.com. Please note that videos are not intended as a replacement or alternave
to this operang and safety manual, but only as an addional learning tool.

SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
SAFETY INFORMATION
This section contains important safety information. Failure to
comply could result in serious injury or death.
Safety Symbols
Personal Protective Equipment (PPE)
Always use Personal Protective Equipment when using the Picote Generator including
suitable overalls / protective clothing & footwear and the following:
Always wear suitable ear protection when using the Picote Generator 400V to
prevent any hearing loss.
Danger risk of serious injury, follow instructions.
Danger risk of serious injury or death by electrocution, follow instructions.
Danger risk of serious injury from hot parts, follow instructions.
Safety symbols are used throughout this manual to draw attention to potential
hazards.
Danger risk of serious injury or death by electrocution, follow instructions.
3Picote Soluons Oy Ltd www.picotesoluons.com
High voltage. Failure to comply may lead to serious injury including
electric shock or injury from rotating parts!
Always remember
Danger risk of serious injury from rotating parts, follow instructions.
Danger of setting fire, follow instructions.
Always wear suitable cut-resistant gloves when using the Maxi Miller Power+ to
prevent any hand injuries. Any open injuries or skin irritations should be cov-
ered at all times to avoid contact with sewage, chemicals or dust.
Before assembly, use, replacement of parts or
maintenance, turn off the Picote Generator.

1. Always use ear protecon as well as protecve gloves. Other personal protecve equipment, such as respirator
mask, protecve glasses and overalls should be worn when necessary. Exhaust gasses produced when operang are
dangerous to your health. Always wear appropriate protecve equipment and venlate the working area properly.
2. When in use, it is very important that the generator is stable and on an even surface at all mes. Working posion is
horizontal and lying at. When generator is lted, fuel spillage may result. When in use, the generator needs to be
placed at least 1m away from buildings and other equipment.
3. Diesel is extremely ammable and explosive under certain condions. Refuel only in a well-
venlated area with the engine stopped. Do not smoke or allow ames or sparks in the area where
the engine is refuelled or where diesel is stored. Wipe up spilled fuel at once. Avoid repeated or
prolonged contact with skin or breathing of vapour.
4. Use automove diesel (diesel number 2 according to EN590) with cetane number of 40 or higher with max. Sulphur
level of 0.5%.
5. Always ensure that the generator is fully turned o and unplugged before inspecon, maintenance, or installing
any accessories to the generator. Always follow the instrucons in the Picote Soluons manual.
6. Never leave the generator running unaended.
7. Never touch rotang parts. Do not stand on the generator. Do not wear loose clothes near the generator.
8. It is allowed to use the generang set in the rain (according to EN60529—protecon class IP23). This means that the
generang set can support water in the form of rain ll max. 60° in respect of the perpendicular line. Do not use the
generang set in the snow. Only use it in spaces where there is no explosion hazard.
9. The generator is a potenal source of electrical shocks when misused. Do not operate the generator with wet
hands.
10. Connecons for standby power to a building’s electrical system must be made by a qualied electrician and must
comply with all applicable laws and electrical codes. Never connect the generang set to the public mains or any
other electrical power source! Improper connecons can allow electrical current from the generator to back feed
into the ulity lines. Such back feed may electrocute ulity company workers, and when ulity power is restored,
the generator may explode, burn or cause res in the building’s electrical system.
11. The muer becomes very hot during operaon and remains hot for a while aer stopping the engine. Be careful
not to touch the muer while it is sll hot. Let the engine cool down before storing the generator indoors. To
prevent burn injuries, pay aenon to the warning marks aached to the generator.
12. Make sure the generator is operated only outdoors. In case of insucient cooling and/or venlaon severe
damage can occur. Exhaust gases also contain poisonous carbon monoxide.
13. Never use the generator when the cover plates are removed from the engine or alternator.
14. Maintenance should be carried out by trained technicians only. Never work on the generator while it is sll running.
15. Never connect appliances that need more power than the generator can provide. This could seriously damage the
generator.
16. Do not use the generator to power up a welding machine as this might damage the alternator.
17. Do not use the generator to power up electronic devices such as computer, TV, radio, plasc welder. Such
appliances might not work or even break down in combinaon with some alternators.
18.Never let the diesel engine run for a long me (= more than 30 min.) at no load or at a very low load (<15%). This
can severely damage the engine!
4Picote Soluons Oy Ltd www.picotesoluons.com
This secon contains important safety informaon. Failure to comply could result in serious injury.
SAFETY REQUIREMENTS
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
Always read all safety warnings and instrucons. Failure to follow warnings and instrucons may result
in electric shock, re and/or serious injury.

5Picote Soluons Oy Ltd www.picotesoluons.com
This secon contains important safety informaon. Failure to comply could result in serious injury.
SAFETY REQUIREMENTS
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
Symbols on the Generator
Symbol Explanation
Here you can fill the tank with diesel. Remove the fuel filler cap and check the
fuel level. Refuel carefully to avoid fuel spillage. Do not fill the tank to the top.
You might have to lower the fuel level, depending on operating conditions. After
refuelling, reinstall the fuel filler cap and tighten it securely. Spilled fuel causes
environmental damage. Wipe up spilled diesel at once.
Diesel drain plug. By loosening this plug you can drain the fuel tank if
necessary. Spilled diesel causes environmental damage. Wipe up spilled diesel
at once. If you will not use the drained diesel again, you have to dispose of it in
a correct and environmentally friendly way. Respect local regulations. Do not
pour diesel into the ground or down the drain.
Show the location where you can fill the oil by loosening the oil filler cap or
dipstick. Fill carefully to avoid oil spillage. Spilled oil should be wiped up
immediately in a correct and environmentally friendly way. Respect the local
regulations. Do not pour oil onto the ground or down the drain. Look at the oil
recommendations from page 18.
After removing the hatch, you can refill the radiator.
Warning: risk of burns! Stop the generating set and let it cool down before
removing the pressure cap. Loosen the pressure cap to release the pressure.
Do not refill the radiator when the engine has just run and is still warm. Wait until
the engine has cooled down and then refill the radiator. Look at coolant
recommendations from page 18.
HOT COOLANT AND STEAM CAN CAUSE SERIOUS INJURY OR DEATH
WARNING! – Electric shock hazard.
Never connect the generator to an installation which is also connected to
a public mains. Improper connections can allow electrical current from the
generator to back feed into the utility lines. Such back feed may electrocute
utility company workers, and when utility power is restored, the generator
may explode, burn or cause fires in the building’s electrical systems.

6Picote Soluons Oy Ltd www.picotesoluons.com
This secon contains important safety informaon. Failure to comply could result in serious injury.
SAFETY REQUIREMENTS
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
Symbols on the Generator
Symbol Explanation
Here an earth pin can be connected. Follow the instructions in this manual
concerning the use of an earth pin.
WARNING! – Hot surface. Can cause burns. Hot engine and hot exhaust
system can cause serious and even lethal injuries. Never work on the
generating set before it has sufficiently cooled down.
Do not smoke nor allow sparks or flames near the generating set, the fuel pipe,
the fuel filter, the fuel pump or other possible sources of spilled fuel or fuel
vapours.
Fuel is highly flammable and explosive and you can be burnt or seriously injured
when refuelling. Turn the engine off and let it cool down before refuelling.
The engine‘s exhaust gases contain poisonous carbon monoxide. You can be
killed or seriously hurt. Do not run the engine in a closed environment. The
exhaust system should be leak-tight and it should be inspected regularly.
Rotating parts can cause serious injuries or death. Do not let the engine run
unless all protective covers, shields and grids are in place.
Make sure the incoming and outgoing air flow is not obstructed.

8Picote Soluons Oy Ltd www.picotesoluons.com
This secon contains important safety informaon. Failure to comply could result in serious injury.
SAFETY REQUIREMENTS
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
Symbols on the Generator
Symbol Explanation
Only use a hoist according to local safety regulations.
Never allow sharp bends in lifting cables and chains.
It is strictly forbidden to dwell or stay in the risk zone under a lifted load. Never
lift the unit over people or residential areas. Never leave a load hanging on a
hoist. Lifting acceleration and retardation shall be kept within safe limits.
To lift heavy parts, a hoist of ample capacity, tested and approved according to
local safety regulations, shall be used.
Lifting hooks, eyes, shackles, etc. shall never be bent and shall only have stress
in line with their design load axis. The capacity of a lifting device diminishes
when the lifting force is applied at an angle to its load axis.
For maximum safety and efficiency of the lifting apparatus all lifting members
shall be applied as near to perpendicular as possible. A hoist has to be installed
in such a way that the object will be lifted perpendicular.
If that is not possible, the necessary precautions must be taken to prevent load-
swinging, e.g. by using two hoists, each at approximately the same angle not
exceeding 30° from the vertical.
WARNING! – Consult the instruction and maintenance manual of the engine
and the alternator before carrying out maintenance. Improper maintenance, or
failure to correct a problem before operation, can cause a malfunction in which
you can be seriously injured or killed.
Always follow the inspection and maintenance recommendations and schedules
mentioned in the instruction and maintenance manual of the engine and the
alternator.

Picote Generator 400V
6
3
7
8
10
9Picote Soluons Oy Ltd www.picotesoluons.com
GENERAL INFORMATION
When in use, always lay the generator down horizontally on the oor as
shown above.
TECHNICAL DATA
Size
(cm/inches)
Outlet
Power
(kVA)
Engine size
(cm3)
Max. Rotaon
speed
(rpm)
Fuel
Tank (l)
Weight
(kg/lb)
IP
Class
138 x 64 x 66
55 x 25 x 26
3 x 400V
1 x 230V
400V : 13.5
230V : 4.5
3-cylinder
893
3000 25 360 / 793 23

PICOTE GENERATOR 400V
The main components of the generang set are: the water-cooled Kubota diesel engine (3000rpm), the alternator,
the control panel, the silenced canopy and the chassis.
For engine and alternator specicaons we refer to the engine and alternator manual supplied with each
generang set.
Specicaons for the control panel can be found in chapter ”Descripon of The Control Panel”.
The chassis of the generang set also serves as fuel tank and contains the ller cap, the mechanical fuel gauge, the
fuel drain plug (for cleaning the fuel tank), 4 xaon holes (for xed mounng of the genset), the baery support
and the support for the (manual) oil drain pump. In the boom of the chassis there is an extra inspecon hole for
oil drain.
The sound-proof canopy of the genset contains: one central liing eye, 2 plasc inspecon hatches for oil ll and
radiator ll, two doors with key (for normal maintenance), the control panel, the baery inspecon hatch, one
grid that sucks in cold air and one grid that emits hot air.
The exhaust on the Picote Generator is separated from the hot air outlet.
7
10 Picote Soluons Oy Ltd www.picotesoluons.com
MAIN COMPONENTS
Type of the generator: New Boy EPS133TDE
Alternator: Sincro FT2MES (with brushes)
Mecc Alte ECP3-3S/2 (brushless, with AVR)
Engine: KUBOTA D902

The control panel of the Picote Generator
contains:
- Starng Key (o / on / glow / start)
- Pilot Lamp Green (contact on / o), lamp
lights up when contact on
- Pilot Lamp Red (baery charging), lamp
lights up when baery not charged
- Emergency Stop
- Hour Counter
- Residual Current Device
- Earth Leakage Protecon (earth pin
included)
- Voltmeter
- 3 sockets
DESCRIPTION OF THE CONTROL PANEL
www.picotesoluons.com Picote Soluons Oy Ltd
11
At the back side of the control panel you will nd:
- The Baery Charging Regulator
- The Timer-Relay for the Stop Solenoid
- 1 Relay 12V/30A for Oil Pressure and Cooling Water Temperature Protecon (engine stops when oil
pressure too low or cooling water temperature too high)
Further, there is free space on the control panel for following opons:
- frequency meter
- 3 amp.meters
- insulaon protecon relay (instead of earth leakage protecon)
- connector for remote control or automac start/stop panel (AMF)
Other opons (as star-delta switch) cannot be added aerwards.

NOISE LEVEL & EMISSIONS
The typical A-weighted noise level determined according to EN60745:
Sound power level (LWA): 95 dB (A)
WEAR EAR PROTECTION
The engine‘s exhaust gases contain poisonous carbon monoxide. You can be killed or seriously hurt. Do not run
the engine in a closed environment. The exhaust system should be leak-ght and it should be inspected regularly.
www.picotesoluons.com Picote Soluons Oy Ltd
13
This secon contains important safety informaon. Failure to comply could result in serious injury or loss
of hearing.
CE DECLARATION OF CONFORMITY
CE-marking: here is example of a EUROPOWER type indicaon plate. The type indicaon plate can be found on
every generator. More informaon on this can be found in the EUROPOWER documentaon or on their web site
www.europowergenerators.com.

This secon contains important safety informaon. Failure to comply could result in serious injury.
STARTING & USING THE GENERATOR
Main elements on the Picote Generator 400V are: 3 sockets with thermal-magnec protecon, earth leakage
protecon, voltmeter, hour counter, pilot lamp for contact ON/OFF, pilot lamp for baery charging, starng key,
emergency stop and fuel level gauge.
ATTENTION! The generang sets are equipped with a 12V electrical fuel pump. This pump may not run “dry”. If
the engine stops because of fuel deciency, turn contact key “OFF”.
Starng the engine:
- Check Oil Level
- Open Fuel Cock (on fuel lter)
- Check The Fuel Level
www.picotesoluons.com Picote Soluons Oy Ltd
14
Open Closed
- Check The Radiator Coolant Level: Filled
up to the ller cap, check also the coolant
level in the expansion tank: the coolant
has to reach up to 1cm below the level
mark “FULL”. If necessary ll it up. The
mixture consists of 50% water and 50%
anfreeze (working temperature mixture
up to -30°C)
- On the type idencaon plate you can nd the maximum charging current of the generang set.
- In case of overload, the thermal-magnec protecon in the control panel will switch o aer some me. Check
the load, reduce it if necessary and switch on the thermal-magnec protecon again.
- In case of short-circuit, the thermal-magnec protecon will switch o immediately! Check the cause of the
short-circuit and then switch on the protecon again.
- Never let the diesel engine run for a long me (= more than 30 min.) at no load or at a very low load (<15%).
This can severely damage the engine.
- Connect Earth Pin
- Preheat During +/- 10 sec.
- Start The Engine with The Starng Key
- Let The Engine Warm Up for a Few Minutes Before Charging.
- Connect The Users.
CHARGING THE GENERATOR SET

This secon contains important safety informaon. Failure to comply could result in serious injury.
STOPPING THE GENERATOR SET
- Let the generang set cool down at no load for a few minutes before stopping the engine. Stop the engine with
the key.
www.picotesoluons.com Picote Soluons Oy Ltd
15
- Make sure there are no obstrucons at the fresh air intake grid where the cooling air for engine and
alternator comes in.
- Make sure the hot air that comes from cooling the engine and alternator can leave easily through the grid,
as well as the exhaust gases.
- Never let the generator run in an inappropriately venlated room!
- Engine: low oil pressure and high cooling-water temperature protecon.
- Alternator: thermal-magnec protecon and earth leakage protecon (with earth pin).
COOLING
PROTECTIONS
USER SAFETY
The Picote Generator is equipped with earth leakage protecon and earth pin, connected following the TN-S
electrical scheme.
Note: Always use the earth pin.
For connecon of charges class 1 (charges with earthing) and charges class 2 (charges with double insulaon, to
be recognized by the “double square” pictogram on the generator) an unlimited number of charges can be
connected to the genset at the same me.
The working of the earth leakage protecon can only be guaranteed if the added earth pin with 4 metres of earthing cable
is connected to the generang set (see symbol ‘earthing’ on the generang set). The earth pin has to be drawn into the
soil completely to guarantee a good funconing.
The spreading resistance of the earth electrode has to be measured by a recognized organisaon.
Residual current device of the Generator is type A and residual current permission is 30 mA.
RESIDUAL CURRENT DEVICE

This secon contains important safety informaon. Failure to comply could result in serious injury.
www.picotesoluons.com Picote Soluons Oy Ltd
16
CONNECTING THE EARTH PIN
Step 1. Connect the Earth Pole to the Picote Generator.
Step2. The earth pin has to be drawn into the soil completely to guarantee good funcon.

Table: Recommendaon of minimum cable secon (in mm²) and maximum cable length (in m) in funcon of the current
(in A):
www.picotesoluons.com Picote Soluons Oy Ltd
17
Cable length Cable length Cable length
Current [A] 0 to 50m (0 to 160ft) 50 to 100m (160 to 330ft) 100 to 150m (330 to 500ft)
61.5mm² 1.5mm² 2.5mm²
81.5mm² 2.5mm² 4mm²
10 2.5mm² 4mm² 6mm²
12 2.5mm² 6mm² 10mm²
16 2.5mm² 10mm² 10mm²
18 4mm² 10mm² 10mm²
ELECTRICAL CABLES
SPARE PARTS
This spare parts list is valid for thePicote Generator.
Please contact your Reseller for informaon on parts for these opons.
130000016 Fuel filter (fuel hose type) dia. 8mm
217990074 Brush holder with brushes
398010482 Air cleaner element
398110722 Fuel filter element
398210902 Oil filter
A10902001 Valve cover seal
A10902002 Fan belt
All maintenance points (air cleaner, oil drain pump, oil ll cap, oil lter, fuel lters, radiator lling cap) easily
accessible. For normal maintenance acvies, consult the engine manual. In case of engine or alternator failure,
contact your Reseller or nearest Picote Service Centre.
Alternator:
All single phase (1*230V) alternators are free of maintenance. A periodic check of the alternator is not necessary.
A visual control of the dierent alternator parts at every general generator maintenance will do.
All types of 3-phase alternators are free of maintenance.
Please check the rotor sha bearing of the alternator at every visual control.
MAINTENANCE

www.picotesoluons.com Picote Soluons Oy Ltd
18
To prevent fuel spillage when transporng or during temporary storage, the generator should be secured upright
in its normal operang posion, with the engine switch in posion “OFF”.
When transporng the generator:
• Close the fuel cock
• Do not overll the tank (there may not be any fuel in the ller neck).
• Do not use the generator while it is placed in a vehicle.
• Take the generator o the vehicle and use it in a well-venlated place.
Before storing the unit for an extended period ( > 2 months):
• Make sure the storage area is free of excessive humidity and dust.
• For diesel generang sets it is beer to ll the tank completely before storing the generang set for a long me.
In this way you can avoid condensaon and corrosion in the diesel tank.
• Refresh the engine oil.
• Remove the baery and connect it to a baery charger. This way you will increase the life span of the baery.
MAINTENANCE CONT.
In case there is problem that you cannot solve using this manual, please consult your reseller or the manufacturer!
TRANSPORT & STORAGE
Engine:
See engine manual for maintenance intervals.
- In the factory, the engine has been lled with coolant for usage down to -30°C (-22 F).
The specicaon of this coolant is BS6580/92 – SAE J1034. Only use coolant with this specicaon!
- In the factory, the engine has been lled with 15W40 oil (for temperatures down to -10°C (14 F)).The minimum
specicaon of this oil has to be API SJ/CF-4.
- If the ambient temperature is lower, 10W40 oil (up to -20°C) or 5W40 oil (down to -30°C (-22 F)) should be
used. Here the minimum specicaon also has to be API SJ/CF-4.

TROUBLESHOOTING FLOWCHART
Fuse trips when
powering up.
Check fuel
level
Check ON/
OFF Switch
Check E-Stop
Switch
Disconnect tools
from the Generator
outlets. Did it
help?
Yes
No
Check for damaged
electrical cables
Contact your reseller
or nearest Picote
Service Centre
The power load
was too heavy.
Generator does not
power up.
RCD trips when
powering up.
Check for faulty
electrical wiring
Check for water
damage.
The machine does
not power up with
Generator.
Test with different
power source.
Does it power up?
No
Yes Fault with
Generator
Fault with the
connected
machine
Generator heats up
too much
Check radiator
cooling water level Check oil level
Clean air intake
grid and remove
obstacles
Remove obstacles
from exhaust pipe
Did it help?
Generator is OK
Yes
No
www.picotesoluons.com Picote Soluons Oy Ltd
19

WARRANTY POLICY AND PROCEDURE
www.picotesoluons.com Picote Soluons Oy Ltd
20
Limited Warranty:
Picote warrants to the original End User that the Product purchased by such End User will operate in
accordance with and substanally conform to their published specicaons when shipped or otherwise
delivered to the End User and for a period of one (1) year, except electric motors for which the warranty
period shall be six (6) months, provided, however, that Picote does not warrant any claim or damage under
this
Warranty if such claim or damage results from:
1. Consumable parts or normal wear and tear resulng from use of the Products,
2. Product overload or overheated motor,
3. Regular periodic maintenance of Products,
4. Misuse, neglect, or improper installaon or maintenance of the Products, or use of Products
not for their intended purpose,
5. Products that have been altered, modied, repaired, opened or tampered with by anyone
other than Picote or an authorized Picote Service Centre, or unsuitable or unauthorized spare
parts, accessories or third party products when using the Products or;
6. the use of the Products not in compliance with their respecve Documentaon, user manuals,
safety and maintenance instrucons, and any usage restricons contained therein, or
7. accident, re, power failure, power surge, or other hazard.
Otherwise, the Products are sold AS IS. End User is responsible for using the Products within
their specicaons and instrucons as contained in the Documentaon.
EXCEPT AS SPECIFIED IN THIS WARRANTY, ALL EXPRESS OR IMPLIED CONDITIONS,
REPRESENTATIONS, AND WARRANTIES INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OR
CONDITION OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NONINFRINGEMENT,
SATISFACTORY QUALITY OR ARISING FROM A COURSE OF DEALING, LAW, USAGE, OR TRADE PRACTICE,
ARE HEREBY EXCLUDED TO THE EXTENT ALLOWED BY APPLICABLE LAW. TO THE EXTENT AN IMPLIED
WARRANTY CANNOT BE EXCLUDED, SUCH WARRANTY IS LIMITED IN DURATION TO THE WARRANTY
PERIOD. BECAUSE SOME STATES OR JURISDICTIONS DO NOT ALLOW LIMITATIONS ON HOW LONG AN
IMPLIED WARRANTY LASTS, THE ABOVE LIMITATION MAY NOT APPLY. This disclaimer and exclusion shall
apply even if the express warranty set forth above fails of its essenal purpose.

Revision Date: 6 Feb. 2019
Revision number: Rev. 1
Author: Mikko Långvik
Accepted: Dawn Greig Please Contact:
Your Reseller / Salesperson or Picote
www.picotesoluons.com
Finland. United Kingdom. USA.
Dawn Greig
Global Business Development &
Creave Director
+44 7585116508
dawn@picotesoluons.com
Anthony DeCavitch
Global Sales Director
+1 219 440 1404
tony@picotesoluons.com
Authorised Resellers:
www.picotesoluons.com/resellers
Jake Saltzman
World Wide Technical Director
+1 706 436 1892
jake@picotesoluons.com
Richard Swan
Head of Technical Client Services
+44 (0)7827 223237
richard@picotesoluons.com
Raudoiajane 4
06450 Porvoo, Finland
support@picotesoluons.com
Producon & R&D
Internaonal Oces Technical Support
Table of contents
Other PICOTE Portable Generator manuals
Popular Portable Generator manuals by other brands

STEELE PRODUCTS
STEELE PRODUCTS SPGG900E owner's manual

Hyundai power products
Hyundai power products 65156 instruction manual

Endress
Endress ESE 2300 i Translation of the original operating manual

Generac Portable Products
Generac Portable Products 4000XL 9777-2 owner's manual

Pts
Pts PTS-G3K13M user manual

Craftsman
Craftsman 919.67937 owner's manual

Generac Power Systems
Generac Power Systems 9 kW NG owner's manual

Matsusada Precision
Matsusada Precision REK Series instruction manual

Briggs & Stratton
Briggs & Stratton Vanguard 10V000 Operator's manual

EINHELL
EINHELL TC-PG 3500 W Original operating instructions

Mase
Mase MPL 66 S Use and maintenance manual

Sportsman
Sportsman GEN4KDF instruction manual