PISCO EQ01-C04P01C08 User manual

●
Standard Quick Exhaust Valve with needle is equipped with Silencer.
R
e-adjustment of exhaust flow is not
needed
when replacing silencer element.
●
Certain models can be used as a shuttle Valve
Push-In Fitting Type Quick Exhaust Valve
Quick Exhaust Valve Series
●For Faster return/movement of Cylinder
●Mini type offers high flow in a compact and lightweight body, a wide
variety of style - available port O.D. sizes are 5/32~1/4", 3~6mm
●
Ideal countermeasure to prevent condensation caused by
adiabatic expansion of small actuators which leads malfunction,
deterioration and the washing down grease of valves etc.
(Install quick exhaust valves close to cylinders or actuators.)
Some smaller models with 1/4" O.D. Available now. Other models
with Inch/NPT/10-32UNF thread are coming soon in Spring 2020.

■ Standard type Model Designation (Example)
01EQ C 04
① Effective area
Code 01 02 03
Effective area
8mm216mm230mm2
Quick Exhaust Valve
①
Eff ective area
⑦
Exhaust-side tube dia.
⑥
Exhaust-side type
P 01 C
⑥
08
⑦
②
Intake-side type ③
Intake-side connection size
⑤
Output-side connection size
④
Output-side type
③ Intake-side connection size
Tube dia. (mm) Taper pipe thread size
Code 04 06 08 10 12 01 02 03 04
Size ø4 ø6 ø8 ø10 ø12 R1/8 R1/4 R3/8 R1/2
② Intake-side type
C:Push-In Fitting
P:Taper pipe thread
④ Output-side type
C:Push-In Fitting
P:Taper pipe thread
⑤ Output-side connection size
Tube dia. (mm) Taper pipe thread size
Code 04 06 08 10 12 01 02 03 04
Size ø4 ø6 ø8 ø10 ø12 R1/8 R1/4 R3/8 R1/2
⑥ Exhaust-side type
C:Push-In Fitting
E:Exhaust needle
⑦ Exhaust-side tube dia.(Exhaust-side type: Push-In Fitting only)
Code 08 10 12
Size (mm) ø8 ø10 ø12
Out
Ex.
In
*The following models may be available for imperial sizes. Ask us for the price.
EQ03
-
C3/8PN2E, EQ03
-
C3/8N3E, EQ03
-
C3/8PN2C1/2
Inch/NPT models are coming soon in Spring 2020
http://www.pisco.com

① Type
■ Mini type Model Designation (Example)
EQ 1/4
Quick Exhaust Valve Series
①
Type
②
Tube dia.
② Tube dia.
ø4 (5/32")
Code
Dia.
4 6
ø6
1/4
ø1/4"
In
Out
In Out
Ex.
*
Union/Stem Type
*Thread type
H
EQ
Quick Exhaust Valve Series
①
Thread type ②Ex. port Type
6
Inlet Tube Size
M5
③
Thread size
①Inlet Tube Size
Code 4 6
Dia. ø6
②Thread Size
③Ex. port type
3
ø3
Code
E
Type Needle Type
Code
Size
M3
M3×0.5
M5
M5×0.8
M6
M6×1
ø4 (5/32")
3
ø3
E
E
Ex.
Inch , 10-32UNF thread
models are coming soon
in Spring 2020.
Open-Air Exhaust
Ste m
Union Straight Open-Air Exhaust
Union Straight Pipe Exhaust
Union Straight Needle Silencer Exhaust
Code
U
Code
Y
Code
E
Type Type TypeType Code
J
In
Out
Ex.
Quick Exhaust Valve Series
For
direct-mounting
on
cylinders/actuators to
control the exhaust flow rate

■ Specifi cations
Fluid medium Air
Operating pressure range
Proof pressure
Operating temp. range
Min. opening pressure 7.25psi (0.05MPa)
196psi (1.35MPa)
41 ~ 140°F (5~ 60°C) (no freezing)
14.5
~102
psi
(0.1 ~ 0.7 MPa)
Sealock - coating
Tube
Element (PVF)
O-ring (NBR)
Thread body (Aluminum)
Guide ring (Nickel-plated brass) Locknut (Aluminum)
Symbol
Tube End
Needle (Nickel-plated brass)
Silencer cover (Aluminum)
Fitting body (Aluminum)
Lock-claws (Stainless steel)
Release ring (POM)
Elastic sleeve (NBR)
Intake-port →
↓
Output-port
Exhaust port
→
Diaphram (HNBR)
■
Construction
Standard type Ex.
(Intake: Push-In Fitting, Output: Thread, Exhaust:Needle)
Symbol
with needle
http://www.pisco.com
■
Construction
Mini type Ex.
(Union Open-Air Exhaust)
Main body (Aluminum)
Lock-claws (Stainless steel)
Guide ring (Copper alloy)
|
|
Lock-claws retainer (Copper alloy)
Elastic sleeve (Nitrile rubber)
Release ring (POM) |
|
__
Diaphram (HNBR) |
Diaphram retainer (Aluminum)|
Main body (Polybutylene terephthalate)
Exhaust cover (Polybutylene terephthalate)

■ Control direction (Example)
Solenoid valve
Cylinder
Flow Controller
High Flow
Quick exhaust valve EXIN
OUT
Air supply
to cylinder
① ②
Air exhaust
from cylinder
①Air from IN is supplied to cylinder
②Air from cylinder is exhausted directly not via solenoid valve.
※Combinations of Quick Exhaust Valve and Flow Controller
High Flow can improve the efficiency of air exhaust.
Air flow
①IN →OUT
②OUT →EX
Standard type
Direct-mounting type ()LJ. 1)LVWKHPRVWHIILFLHQWDLUGLVFKDUJHZLWKH[KDXVWLQJDLURQWKHF\OLQGHUSRUWV7KH
H[KDXVWHIILFLHQF\GHSHQGVRQWKHWXELQJOHQJWKLQFDVHRI,QOLQHW\SHILJWKHVKRUWHUWKHEHWWHU7KHDLU
WUDYHOVEDFNWKURXJKV\VWHPLQFDVHRIIORZFRQWUROOHUV (condensation may also be caused in case of short
stroke of actuators)WKHTXLFNH[KDXVWYDOYHVDUHUHFRPPHQGHGZKHQUDSLGF\OLQGHUUHWXUQLVQHHGHG or for
preventing condensation
●
Cylinder speed control by flow controllers
Solenoid valve
●
Cylinder speed control by quick exhaust valves
(needle type)
WXELQJ
OHQJWK
ÎEx.
Ì
Ex.
Fig.1. Example - Direct-mounting type
Fig.2. Example - In-line type
Fig. 3.
Mini type
cylinder
Solenoid valve
cylinder
Quick Exhaust Valve Series

Type
IN tube
dia.
OUT thread size
EX tube
dia.
R1/8 R1/4 R3/8 R1/2
EQ 4●8
IN & EX port: Fitting
6●
OUT port: Thread
● ● 10
(Tube exhaust) 8● ●
10 ●●●12
12 ●●●
■ Standard Size List
Standard type
Mini type
Type Tube dia.
4(5/32) 6
EQU
Union Straight Open-Air Exhaust
●●
EXIN
OUT
Type
IN tube
dia.
OUT thread size
EX tube
dia.
6 8 10 12
EQ R1/8 ●8
OUT & EX port : Fitting
● ● 10
IN port: Thread
R1/4 ● ●
(Tube exhaust) R3/8 ● ● 12
R1/2 ● ●
EX
IN
OUT
Type
IN tube
dia.
OUT thread size
R1/8 R1/4 R3/8 R1/2
EQ 4●
IN port: Fitting 6● ●
OUT port: Thread
8● ●
EX needle type 10 ● ● ●
(Open-air exhaust)
12 ● ● ●
EX
IN
OUT
EX needle type
EX
IN OUT
Type Tube dia.
4 (5/32) 6
EQY Union Straight Tube Exhaust ●●
EX
IN OUT
Type Tube dia.
4 (5/32) 6
EQE
Union Straight Needle Silencer Exhaust
●●
1/4
1/4
1/4
●
●
●
3
●
3
●
3
●
●
EXH
IN OUT
Needlecontrol
Type IN
Tube dia.
OUT thread size EX
thread size
M3×0.5 M5×0.8
EQH
Cylinder Direct Mount ing
Exhaust Female Thread
3● ●
M6×1
4● ●
6● ●
IN
OUT
EXH
Type IN
Tube dia.
OUT thread size
M3×0.5 M5×0.8
EQH
Cylinder Direct Mounting with Needle
3● ●
4● ●
6● ●
IN
OUT
EXH
Needle control
4 6
EQJ 4●
6●
EXH
EXH
IN OUT
http://www.pisco.com
TypeType Tube dia.
6WHPdia.
Stem Open-Air Exhaust
Inch/NPT models are
coming soon in Spring 2020

■ How to adjust the speed (Exhaust needle type only)
1. Speed adjustment of actuators
①Increasing speed
Turn the needle in the counterclockwise from a
fully closed state. The more the needle is
opened, the faster the actuator moves. Make sure
to tighten the locknut at the desired speed.
The speed setting can be changed without
tightening the locknut.
②Reducing speed
Turn the needle in the clockwise when the
speed is too fast. Make sure to tighten the
locknut at the desired speed. The speed setting
can be changed without tightening the locknut.
■ How to replace silencer element
1. Replacement of silencer element
①Remove the silencer cover by loosening it in the
counterclockwise direction.
②Remove the silencer element.
③Attach a new silencer element to the metallic body
up to the end.
④Place the silencer cover over the element and
tighten the cover in the clockwise direction.
※Make sure to stop air supply before replacing
silencer element. No need to readjust the needle
after the replacement of silencer element.
Silencer element
Model code
Element Model code
EQ 01-C □P□E
EQSE-01E
EQ 02-C □P□E
EQSE-02E
EQ 03-C □P□E
EQSE-03E
Silencer cover
Metallic body
■ How to insert and disconnect
1. How to insert and disconnect tubes
①Tube insertion
Insert a tube into Push-In Fitting up to the tube end. Lock-claws bite the
tube and fix it automatically, then the elastic sleeve seals around the
tube.
Refer to “2. Instructions for Tube Insertion”under “Common Safety
Instructions for Fittings” .
②Tube disconnection
The tube is disconnected bypushing release-ring torelease Lock-
claws.
Make sure to stop air supply before the tube disconnection.
2. How to tighten thread
①Tightening thread
Use a spanner to tighten a hexagonal-column or square part of the product.
Refer to “Table: Recommended tightening torque”under “2. Instructions for
Installing Controllers”in “Common Safety Instructions for Controllers”.
Hexagonal-column

EQ
Unit:mm
Model code
Tube O.D.
øD1
Tube O.D.
øD2 R A B L1 L2
Tube end
C1
Tube end
C2 E1 E2 □F
Effective area(mm
2
)
Weight
(g)
CAD
file name
IN →OUT
OUT →EX
EQ01-C04P01C08
48 1/8 8 25.5 21.5 14 10.9 18.2 46.5 23.8 15 49 19
CRE-001
EQ01-C06P01C08
611.7 46.8 24.1 6
EQ02-C06P01C10
6
10
1/8 8 29
25 16
11.7
20.7
54.4 28.1
18
9
16
27
EQ02-C06P02C10
1/4 11 31 29
EQ02-C08P01C10
81/8 8 29 18.2 59.7 33.4 12 31
EQ02-C08P02C10
1/4 11 31 33
EQ03-C10P02C12
10
12
1/4 11 40.5 34.5 22
20.7
23.3
74.6 42.8
25
24 34 69
EQ03-C10P03C12
3/8 12 34.2 21.7 25 35 72
EQ03-C10P04C12
1/2 15 42.5 34.3 21.8 27 37 77
EQ03-C12P02C12
12
1/4 11 40.5 34.5 22
23.3 76.2 44.4
25 34 73
EQ03-C12P03C12
3/8 12 34.2 21.7 26 35 75
EQ03-C12P04C12
1/2 15 42.5 34.3 21.8 28 37 80
※. “L1”and “L2”are reference values for height dimensions after tightening taper thread.
R
øD1
øD2
B
L1
L2
A
IN & EX port: Fitting OUT port: Thread
(Tube exhaust) E1
E2
C1
C2
□F
■ Standard type
compliant
Detailed Safety Instructions
Before using PISCO products, be sure to read “Safety Instructions” and “Safety
Instruction Manual” and “Common Safety Instructions for Controllers”
Warning
1. When controlling the speed of actuators with needle type, slowly release the air by adjusting
the needle from a fully closed state. In case the needle is opened, actuator can move
suddenly. As for other than needle types, make sure to confirm the safety before operation.
2. Do not swing or rotate resin body of the products by force. It may damage to the
products and cause a fluid leakage.
Caution
1. The clogging of silencer element increases exhaust-resistance. There is a possibility that it
causes the system
malfunction
.
2. Make sure to provide a differential pressure when Quick Exhaust Valve is used as a
shuttle valve. It can cause a malfunction without the differential pressure.
3. When replacing a silencer element, make sure to place the silencer cover over the
element and tighten the cover by hand firmly. The element
for
mini type, EQE
can not be replaced
.
4. Use a proper tool to tighten a hexagonal-column or square part of Quick Exhaust Valve. Refer
to “2. Instructions for Installing Controllers” in “Common Safety Instructions for Controllers”.
5. Adjust the tube direction while tightening thread within the tightening torque limits, since
some PISCO products do not swivel after the installation.
6. Exhaust air dirt may adhere to Exhaust port area (around outer hexagonal thread) of EQH (Exhaust
needle type) and become discolored depending on the use conditions and use frequency, but it is not
an abnormality.

EQ
R
øD
B
A
øP
E1
E2
E3
C□F
L1
L2
IN port: Fitting OUT port: Thread
Needle silencer exhaust (Silencer exhaust)
Unit:mm
Model code
Tube O.D.
øD R A B L1 L2 øP
Tube end
C
E1 E2 E3 □F
Effective area(mm
2
)
Weight
(g)
CAD
file name
max.
min.
IN →OUT
OUT →EX
EQ01-C04P01E
4 1/8 8 25.5 21.5 14 15 10.9 66.7 61.8 54.3 23.8 15 4 8 23
CRE-003
EQ01-C06P01E
61/8 825.5 21.5 14 15
11.7
67 62.1 54.6 24.1 15 6 8 23
EQ02-C06P01E
29 25 16 18 77.4 71.6 63.1 28.1 18 9 15 35
EQ02-C06P02E
1/4 11 31 37
EQ02-C08P01E
81/8 8 29 25 16 18 18.2 82.7 76.9 68.4 33.4 18 12 15 39
EQ02-C08P02E
1/4 11 31 41
EQ03-C10P02E
10
1/4 11 40.5 34.5 22
25 20.7
112.7 105.3
95.8 42.8 25
24 31 97
EQ03-C10P03E
3/8 12 34.2 21.7 25 98
EQ03-C10P04E
1/2 15 42.5 34.3 21.8 27 34 102
EQ03-C12P02E
12
1/4 11 40.5 34.5 22
25 23.3
114.3 106.9
97.4 44.4 25
25 31 99
EQ03-C12P03E
3/8 12 34.2 21.7 26 102
EQ03-C12P04E
1/2 15 42.5 34.3 21.8 28 34 106
※. “L1”and “L2”are reference values for height dimensions after tightening taper thread.
compliant
EQ
Unit:mm
Model code
Tube O.D.
øD1
Tube O.D.
øD2 R A B L1 L2 øP1 øP2
Tube end
C1
Tube end
C2 JHex.
H
Effective area(mm
2
)
Weight
(g)
CAD
file name
IN→OUT
OUT →EX
EQ01-P01C06C08
6 8 1/8 8 43.2 39.2 14.9 12.4 18.4 17 18.2 25.5 14 5.5 6.5 22
CRE-002
EQ02-P01C06C10
6
10
1/8 8 50.3 46.3 18.8
14.4 22
17
20.7
29
17
8 9 33
EQ02-P01C08C10
818.1 28.9 10 12
EQ02-P02C06C10
61/4 11 53.3 47.3 19.7 17 29 8 9 35
EQ02-P02C08C10
818.1 28.9 10 12
EQ03-P03C10C12
10
12
3/8 12 64.2 57.9 22.5 17.6
28
20.2
23.3
33.6
22
21 24 75
EQ03-P03C12C12
12 64.3 58 24.2 21 23.4 36.4 22 27 78
EQ03-P04C10C12
10 1/2 15 67.2 59 23.6 17.6 20.2 33.6 21 24 81
EQ03-P04C12C12
12 67.3 59.1 25.3 21 23.4 36.4 23 27 84
※. “L1”and “L2”are reference values for height dimensions after tightening taper thread.
R
øD1
øP1
øD2
øP2
OUT & EX port : Fitting IN port: Thread
(Tube exhaust) B
J
C1
L1
AH
C2L2
compliant

EQU
Unit:mm
Model code
Tube O.D.
øD B L øP1 øP2 øP3
Tube end
C
Effective area(mm
2
)
Weight
(g)
CAD
file name
IN →OUT
OUT →EX
EQU-4 4 (
5/32
) 34.6 11 8.4 10 11 1.8 1.8 3.3 EQU-4
EQU-6 6 37 12 10.4 12 11 11.6 4 4 4.9 EQU-6
øP2
øP3
2-øD
øP1
B
2-C
15L
Union Straight Open-Air Exhaust
■ Mini type
Mini
EQY
Unit:mm
Model code
Tube O.D.
øD B L1 L2 L3 øP1 øP2 øP3 øP4
Tube end
CE
Effective area(mm2)
Weight
(g)
CAD
file name
IN →OUT
OUT→EX
34.6 29.9 18.5 13.8 10 9 8.4 9 11 11
øP3
øP2
3-øD
øP1
E
øP4
B
L2
3-C
L3
L1
Union Straight Tube Exhaust
Mini
compliant
compliant
1/4
EQU-1/423.5 1212 12 17
59.9
EQU-3 3 34.6 11 3.5 EQU-3
8.4 10 9 11 N/A N/A
9 8.4 9 11 11 1.8 1.8 5.2 EQY-4
11 10.4 11 11.6 13 4 4 7.6 EQY-6
17
12 12 12 13
EQY-4 34.6 29.9 18.5 13.8 10
EQY-6 6 37 32 20 15 12
1/4
EQY-1/4
4 (
5/32
)
59.9 26.5
54.912
31.5
5.6 EQY-3
EQY-3 3 N/A N/A
EQE
Unit:mm
Union Straight Needle Silencer Exhaust
Mini
compliant
4.5
L3
2-øD
øP2
L2
E
øP4
ø4.4
øP1
øP3
B
L1 2-C
2-X
2-Y
Release ring dimensions
B L1 L2 L3
øP1 øP2 øP3 øP4
E X Y (g)
CAD
max.
min.
EQE-3 3
34.6 18.5 11.2 18.5 13.5
9 10 8.4 9 11 11 9.8 7.8 7.4 EQE-3
EQE-4
34.6 18.5 11.2 19.5 14.5
9 10 8.4 9 11 11 9.8 7.8 7.2 EQE-4
EQE-6 6 37 20 12 19 14 11 12
10.4
11
11.6
13
11.8
9.8 9.2 EQE-6
1/4
EQE-1/4
Tube O.D.
øD
Model code
Tube end
C
Weight
file name
9
4 (
5/32
)
1/4" O.D. available
1/4" O.D. available
1/4" O.D. available

EQH
EQH
R A B L1 L2 øP E X Y (g)
CAD
EQH-3M3M6
3
M3×0.5
2.5 19.2 16.7 7.7 9 11 22.2 9.8 7.8 6.6
EQH-3M3M6
EQH-3M5M6
M5×0.8
2.9 19.7 16.8 7.8 7.4
EQH-3M5M6
EQH-4M3M6
4
M3×0.5
2.5 19.2 16.7 7.7 9 11 22.2 9.8 7.8 6.5
EQH-4M3M6
EQH-4M5M6
M5×0.8
2.9 19.7 16.8 7.8 7.3
EQH-4M5M6
EQH-6M3M6
6
M3×0.5
2.5 19.2 16.7 7.5 11 11.6 23.7 11.8 9.8 7.4
EQH-6M3M6
EQH-6M5M6
M5×0.8
2.9 19.7 16.8 7.6 8.1
EQH-6M5M6
R A B L1 L2 øP E X Y (g)
CAD
max. min. max. min.
EQH-3M3E 3
M3×0.5
2.5 35.8 30.8 33.3 28.3 7.7 9 11 22.2 9.8 7.8 9.2
EQH-3M3E
EQH-3M5E
M5×0.8
2.9 36.3 31.3 33.4 28.4 7.3 9.9
EQH-3M5E
EQH-4M3E 4
M3×0.5
2.5 35.8 30.8 33.3 28.3 7.7 9 11 22.2 9.8 7.8 9.1
EQH-4M3E
EQH-4M5E
M5×0.8
2.9 36.3 31.3 33.4 28.4 7.3 9.8
EQH-4M5E
EQH-6M3E 6
M3×0.5
2.5 35.8 30.8 33.3 28.3 7.5 11 11.6 23.7 11.8 9.8 10
EQH-6M3E
EQH-6M5E
M5×0.8
2.9 36.3 31.3 33.4 28.4 7.6 11
EQH-6M5E
ø10.4
øD
B
L1
L2A
R
C
X
Y
E
øP
Hex. 8
Mini
Mini
ø10.4
øD
M6×1
5
B
L1
L2A
R
C
X
Y
Hex. 10
E
øP
Release ring dimensions
Release ring dimensions
Unit:mm
Unit:mm
Model code
Model code
Tube O.D.
øD
Tube O.D.
øD
Tube end
Tube end
C
C
Weight
Weight
file name
file name
Cylinder Direct-
Mounting with Needle
Cylinder Direct-Mounting
Exhaust Female Thread
EQJ
Unit:mm
Tube O.D.
øD1
Stem O.D.
øD2 BL øP
Tube end
C
Hex
HX Y Weight
(g)
CAD
file name
EQJ-4 4 4 41 18.2 9 11 10 9.8 7.8 2.3 EQJ-4
EQJ-6 6 6 47.3 21 11 11.6 12 11.8 9.8 3.9 EQJ-6
CY
H
B
L
øD1
øP
øD2
X
Stem Open-Air
Exhaust
Mini
compliant
compliant
compliant
Model code

Pressure(MPa)
0.1
200
400
600
800
1000
1200
1400
1600
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Pressure(MPa)
0.1
500
1000
1500
2000
2500
3000
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Pressure (MPa)
0.1
500
1000
1500
2000
2500
3000
3500
4000
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8
⑧
③
②
①
④
④
⑤
⑥
⑥
⑦
⑨
⑫
⑪⑪
⑩
⑰
⑯
⑯
⑮
⑭
⑬
⑳
⑲
⑱
No.
Model Direction
No.
Model Direction
①
EQ01-C04P01C08
INOUT ⑩
EQ03-P03C10C12
INOUT
EQ01-C04P01E
EQ03-P04C10C12
②
EQ01-P01C06C08
INOUT ⑪
EQ03-P03C12C12
INOUT
③
EQ01-C06P01C08
INOUT ⑫
EQ03-P04C12C12
INOUT
EQ01-C06P01E
⑬
EQ03-C10P02C12
INOUT
④
EQ01-P01C06C08
OUTEXH
EQ03-P03C10C12
OUTEXH
⑤
EQ02-P01C06C10
INOUT
EQ03-P04C10C12
EQ02-P02C06C10
EQ03-C10P02E
INOUT
⑥
EQ01-C04P01C08
OUTEXH
⑭
EQ03-C10P03C12
INOUT
EQ01-C06P01C08 EQ03-C12P02C12
EQ02-C06P01C10
INOUT
EQ03-C10P03E
EQ02-C06P02C10
EQ03-C12P02E
EQ02-P01C06C10
OUTEXH
⑮
EQ03-C12P03C12
INOUT
EQ02-P02C06C10
EQ03-C12P03E
EQ02-C06P01E
INOUT
⑯
EQ03-C10P04C12
INOUT
EQ02-C06P02E
EQ03-P03C12C12
OUTEXH
⑦
EQ02-P01C08C10
INOUT
EQ03-P04C12C12
EQ02-P02C08C10
EQ03-C10P04E
INOUT
⑧
EQ02-C08P01C10
INOUT ⑰
EQ03-C12P04C12
INOUT
EQ02-C08P02C10
EQ03-C12P04E
EQ02-P01C08C10
OUTEXH
⑱
EQ03-C10P02C12
OUTEXH
EQ02-P02C08C10 EQ03-C12P02C12
EQ02-C08P01E
INOUT ⑲
EQ03-C10P03C12
OUTEXH
EQ02-C08P02E
EQ03-C12P03C12
⑨
EQ02-C06P01C10
OUTEXH
⑳
EQ03-C12P04C12
EQ03-C10P04C12
OUTEXH
EQ02-C06P02C10
EQ02-C08P01C10
EQ02-C08P02C10
■ Flow characteristic
Standard type
Flow rate (l/min(ANR)) (0.5MPa)
Flow rate (l/min(ANR)) (0.5MPa)
Flow rate (l/min(ANR)) (0.5MPa)
Quick Exhaust Valve Series

Needle rotation (times)
21
50
100
150
03 4 5 6 7 8 9 10 11 12 13 14 Full
EQ 01-C04P01EEQ 01-C04P01E:
:
: OUT
: OUT
OUT
OUT
EXHEXH
EQ 01-C06P01EEQ 01-C06P01E EXHEXH
21
500
1000
1500
2000
03 4 5 6 7 8 9 10 11 12 13 14 Full
Needle rotaton (times)
21
200
400
600
800
1000
0 43 5 6 7 8 9 10 11 12 13 Full
EQ 02-C06P01EEQ 02-C06P01E:
:
: OUT
: OUT
OUT
OUT
EXHEXH
EQ 02-C08P02EEQ 02-C08P02E EXHEXH
C12P04EC12P04E
C10P04EC10P04E
:
:
: OUT
: OUT
OUT
OUT
EXHEXH
EXHEXH
EQEQ 0303-C10P02E-C10P02E
2P03E2P03E:
:
: OUT
: OUT
OUT
OUT
EXHEXH
EXHEXH
-C1-C1EQEQ 0303
Standard type
Needle rotaton (times)
Flow rate (l/min(ANR)) (0.5MPa)
Flow rate (l/min(ANR)) (0.5MPa)
Flow rate (l/min(ANR)) (0.5MPa)
QQ
EQ 03-EQ 03-
EE 03-03-
http://www.pisco.com

Pressure(MPa)
0.1
20
40
60
80
100
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Pressure(MPa)
0.1
50
100
150
200
250
300
350
400
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8
1
50
100
150
200
250
0 2 3 4 5 6 7 8 9
10 11 12 13
EQE-6: OUTEQE-6: OUTEXHEXH
EQE-3: OUTEQE-3: OUT
-4: OUT-4: OUT
EXHEXH
EXHEXH
EQEEQE
1
50
100
0 2 3 4 5 6 7 8 9
10 11 12 13
EQH-3M3E: OUTEQH-3M3E: OUTEXHEXH
EQH-4M3E: OUTEQH-4M3E: OUTEXHEXH
EQH-4M5E: OUTEQH-4M5E: OUT
EQH-3M5E: OUTEQH-3M5E: OUTEXHEXH
EXHEXH
EQH-6M5E: OUTEQH-6M5E: OUTEXHEXH
EQH-6M3E: OUTEQH-6M3E: OUTEXHEXH
①
③
②
②
④④
⑤
⑦
⑦
⑥
⑧
⑧
No.
形 式 流れ方向
No.
形 式 流れ方向
No.
形 式 流れ方向
①
EQH-3M3E INOUT
④
EQH-6M3E INOUT
⑦
EQU-4 INOUT
EQH-3M3M6 INOUT EQH-6M3M6 INOUT OUTEXH
OUTEXH OUTEXH EQY-4 INOUT
②
EQH-3M5E INOUT ⑤EQH-6M5M6 OUTEXH OUTEXH
EQH-4M3E
⑥
EQU-3 INOUT EQE-4 INOUT
EQH-3M5M6 INOUT OUTEXH
⑧
EQU-6 INOUT
OUTEXH EQY-3 INOUT OUTEXH
EQH-4M3M6 INOUT OUTEXH EQY-6 INOUT
OUTEXH EQE-3
INOUT
OUTEXH
③
EQH-4M5E INOUT EQH-6M5E EQE-6 INOUT
EQH-4M5M6 INOUT EQH-6M5M6
OUTEXH
Needle rotaton (times) Needle rotaton (times)
Flow rate (l/min(ANR)) (0.5MPa)
Flow rate (l/min(ANR)) (0.5MPa)
Flow rate (l/min(ANR)) (0.5MPa)
Flow rate (l/min(ANR)) (0.5MPa)
Mini type
Quick Exhaust Valve Series

SAFETY Instructions
Warning
This safety instructions aim to prevent personal injury and damage to
properties by requiring proper use of PISCO products.
Be certain to follow ISO 4414 and JIS B 8370
ISO 4414:Pneumatic fluid power…Recomendations for the application of equipment
to transmission and control systems.
JIS B 8370:
General rules and safety requirements for systems and their components.
This safety instructions is classified into “Danger”, “Warning” and “Caution” depending on
the degree of danger or damages caused by improper use of PISCO products.
1. Selection of pneumatic products
① A user who is a pneumatic system designer or has sufficient experience
and technical expertise should select PISCO products.
② Due to wide variety of operating conditions and applications for PISCO
products, carry out the analysis and evaluation on PISCO products.
The pneumatic system designer is solely responsible for assuring that
the user's requirements are met and that the application presents no
health or safety hazards. All designers are required to fully understand
the specifications of PISCO products and constitute all systems based
on the latest catalog or information, considering any malfunctions.
2. Handle the pneumatic equipment with enough knowledge and experience
① Improper use of compressed air is dangerous. Assembly, operation
and maintenance of machines using pneumatic equipment should be
conducted by a person with enough knowledge and experience.
3. Do not operate machine / equipment or remove pneumatic equipment until
safety is confirmed.
① Make sure that preventive measures against falling work-pieces or
sudden movements of machine are completed before inspection or
maintenance of these machine.
② Make sure the above preventive measures are completed. A
compressed air supply and the power supply to the machine must be
off, and also the compressed air in the systems must be exhausted.
③ Restart the machines with care after ensuring to take all preventive
measures against sudden movements.
Danger
Hazardous
personal injury.
conditions. It can cause death or serious
Warning
Hazardous conditions depending
PISCO products can cause death or serious personal injury.
on usages. Improper use of
Caution
Hazardous conditions depending
products can cause personal injury or damages to properties.
on usages. Improper use of PISCO
※. This safety instructions are subject to change without notice.

SAFETY INSTRUCTION MANUAL
Danger
1. Do not use PISCO products for the following applications.
① Equipment used for maintaining / handling human life and body.
② Equipment used for moving / transporting human.
③ Equipment specifically used for safety purposes.
Warning
1. Do not use PISCO products under the following conditions.
①
Beyond the specifications or conditions stated in the catalog, or the instructions.
② Under the direct sunlight or outdoors.
③ Excessive vibrations and impacts.
④
Exposure / adhere to corrosive gas, inflammable gas, chemicals, seawater, water and vapor. *
* Some products can be used under the condition above( ④ ), refer to
the details of specification and condition of each product.
2. Do not disassemble or modify PISCO products, which affect the
performance, function, and basic structure of the product.
3.
Turn off the power supply, stop the air supply to PISCO products, and make sure
there is no residual air pressure in the pipes before maintenance and inspection.
4.
Do not touch the release-ring of push-in fitting when there is a working pressure.
The lock may be released by the physical contact, and tube may fly out or slip out.
5. Frequent switchover of compressed air may generate heat, and there is a
risk of causing burn injury.
6. Avoid any load on PISCO products, such as a tensile strength, twisting
and bending. Otherwise, there is a risk of causing damage to the products.
7. As for applications where threads or tubes swing / rotate, use Rotary
Joints, High Rotary Joints or Multi-Circuit Rotary Block only. The other
PISCO products can be damaged in these applications.
8.
Use only Die Temperature Control Fitting Series, Tube Fitting Stainless SUS316
Series, Tube Fitting Stainless SUS316 Compression Fitting Series or Tube Fitting
Brass Series under the condition of over 60℃ (140°F) water or thermal oil. Other
PISCO products can be damaged by heat and hydrolysis under the condition above.
9.
As for the condition required to dissipate static electricity or provide an antistatic
performance, use EG series fitting and antistatic products only, and do not use other PISCO
products. There is a risk that static electricity can cause system defects or failures.
10. Use only Fittings with a characteristic of spatter-proof such as Anti-
spatter or Brass series in a place where flame and weld spatter is
produced. There is a risk of causing fire by sparks.
11.
Turn off the power supply to PISCO products, and make sure there is
no residual air pressure in the pipes and equipment before maintenance.
Follow the instructions below in order to ensure safety.
①
Make sure the safety of all systems related to PISCO products before maintenance.
②
Restart of operation after maintenance shall be proceeded with care after
ensuring safety of the system by preventive measures against unexpected
movements of machines and devices where pneumatic equipment is used.
③ Keep enough space for maintenance when designing a circuit.
12. Take safety measures such as providing a protection cover if there is a
risk of causing damages or fires on machine / facilities by a fluid leakage.
PISCO products are designed and manufactured for use in general industrial
machines. Be sure to read and follow the instructions below.

Caution
1. Remove dusts or drain before piping. They may get into the peripheral
machine / facilities and cause malfunction.
2. When inserting an ultra-soft tube into push-in fitting, make sure to place
an Insert Ring into the tube edge. There is a risk of causing the escape of
tube and a fluid leakage without using an Insert Ring.
3. The product incorporating NBR as seal rubber material has a risk of
malfunction caused by ozone crack. Ozone exists in high concentrations
in static elimination air, clean-room, and near the high-voltage motors,
etc. As a countermeasure, material change from NBR to HNBR or FKM is
necessary. Consult with PISCO for more information.
4. Special option “Oil-free” products may cause a very small amount of a fluid
leakage. When a fluid medium is liquid or the products are required to be
used in harsh environments, contact us for further information.
5. In case of using non-PISCO brand tubes, make sure the tolerance of the
outer tube diameter is within the limits of Table 1.
●Table 1. Tube O.D. Tolerance
mm size Nylon tube
Polyurethane tube
inch size Nylon tube
Polyurethane tube
ø1.8mm ─ ± 0.05mm ø1/8 ±0.1mm ±0.15mm
ø3mm ─ ±0.15mm ø5/32 ±0.1mm ±0.15mm
ø4mm ±0.1mm ±0.15mm ø3/16 ±0.1mm ±0.15mm
ø6mm ±0.1mm ±0.15mm ø1/4 ±0.1mm ±0.15mm
ø8mm ±0.1mm ±0.15mm ø5/16 ±0.1mm ±0.15mm
ø10mm ±0.1mm ±0.15mm ø3/8 ±0.1mm ±0.15mm
ø12mm ±0.1mm ±0.15mm ø1/2 ±0.1mm ±0.15mm
ø16mm ±0.1mm ±0.15mm ø5/8 ±0.1mm ±0.15mm
6. Instructions for Tube Insertion
① Make sure that the cut end surface of the tube is at right angle without
a scratch on the surface and deformations.
② When inserting a tube, the tube needs to be inserted fully into the push-
in fitting until the tubing edge touches the tube end of the fitting as
shown in the figure below. Otherwise, there is a risk of leakage.
Tube end
Sealing
Tube is not fully inserted up to tube end.
③ After inserting the tube, make sure it is inserted properly and not to be
disconnected by pulling it moderately.
※.
When inserting tubes, Lock-claws may be hardly visible in the hole, observed
from the front face of the release-ring. But it does not mean the tube will
surely escape. Major causes of the tube escape are the followings;
①Shear drop of the lock-claws edge
②The problem of tube diameter (usually small)
Therefore, follow the above instructions from ① to ③, even lock-claws
is hardly visible.
Good Imcomplete

7. Instructions for Tube Disconnection
①
Make sure there is no air pressure inside of the tube, before disconnecting it.
② Push the release-ring of the push-in fitting evenly and deeply enough to
pull out the tube toward oneself. By insufficient pushing of the release-
ring, the tube may not be pulled out or damaged by scratch, and tube
shavings may remain inside of the fitting, which may cause the leakage
later.
8. Instructions for Installing a fitting
① When installing a fitting, use proper tools to tighten a hexagonal-column
or an inner hexagonal socket. When inserting a hex key into the inner
hexagonal socket of the fitting, be careful so that the tool does not
touch lock-claws. The deformation of lock-claws may result in a poor
performance of systems or an escape of the tube.
② Refer to Table 2 which shows the recommended tightening torque. Do
not exceed these limits to tighten a thread. Excessive tightening may
break the thread part or deform the gasket and cause a fluid leakage.
Tightening thread with tightening torque lower than these limits may
cause a loosened thread or a fluid leakage.
③ Adjust the tube direction while tightening thread within these limits,
since some PISCO products are not rotatable after the installation.
●Table 2: Recommended tightening torque / Sealock color / Gasket
materials
Thread type Thread size Tightening torque Sealock color Gasket materials
Metric thread
M3 ×0.5 0.7N·m
─
SUS304
NBR
M5 ×0.8 1.0 ~ 1.5N·m
M6 ×1 2 ~ 2.7N·m
M3 ×0.5 0.5 ~ 0.6N·m
POM
M5 ×0.8 1 ~ 1.5N·m
M6 ×0.75 0.8 ~ 1N·m
M8 ×0.75 1 ~ 2N·m
Taper pipe thread
R1/8 7 ~ 9N·m
White ─
R1/4 12 ~ 14N·m
R3/8 22 ~ 24N·m
R1/2 28 ~ 30N·m
Unified thread No.10-32UNF 1.0 ~ 1.5N·m─SUS304、NBR
National pipe
thread taper
1/16-27NPT 7 ~ 9N·m
White ─
1/8-27NPT 7 ~ 9N·m
1/4-18NPT 12 ~ 14N·m
3/8-18NPT 22 ~ 24N·m
1/2-14NPT 28 ~ 30N·m
※ These values may differ for some products. Refer to each specification as well.
9. Instructions for removing a fitting
① When removing a fitting, use proper tools to loosen a hexagonal-column
or an inner hex bolt.
② Remove the sealant stuck on the mating equipment. The remained
sealant may get into the peripheral equipment and cause malfunctions.
10.
Arrange piping avoiding any load on fittings and tubes such as twist,
tensile, moment load, shaking and physical impact. These may cause
damages to fittings, tube deformations, bursting and the escape of tubes.

Warning
Common Safety Instructions for Controllers
Before selecting or using PISCO products, read the following instructions. Read the
detailed instructions for individual series as well as the instructions below.
1. Some products have an air direction to control. Make sure to distinguish the
direction by marking on the products. Installing the product with the wrong
direction may cause personal injury or property damage.
2. Avoid any load on PISCO products such as a tensile strength, twisting,
bending, dropping and excessive impacts. These may cause damage to the
products.
3. Locknut needs to be tightened by hand. Do not use any tool. Using tools to
tighten the locknut may cause damage to the products. Also, inadequate
tightening may loosen the locknut and the initial setting can be changed.
4. Use clean air to supply. Dusts and sludge may result in the change of the
initial setting.
Disclaimer
1. PISCO does not take any responsibility for any incidental or indirect
loss, such as production line stop, interruption of business, loss
of benefits, personal injury, etc., caused by any failure on use or
application of PISCO products.
2. PISCO does not take any responsibility for any loss caused by natural
disasters, res not related to PISCO products, acts by third parties, and
intentional or accidental damages of PISCO products due to incorrect
usage.
3. PISCO does not take any responsibility for any loss caused by improper
usage of PISCO products such as exceeding the specication limit or not
following the usage the published instructions and catalog allow.
4. PISCO does not take any responsibility for any loss caused by remodeling
of PISCO products, or by combinational use with non-PISCO products and
other software systems.
5. The damages caused by the defect of Pisco products shall be covered but
limited to the full amount of the PISCO products paid by the customer.

Caution
1. Refer to “Common Safety Instructions for Fittings” for the safety instructions
for fitting part.
2. Instructions for Installing Controllers
① Use proper tools to tighten a hexagonal-column or a knurling, when installing
the controller.
② Refer to the following table which shows the recommended tightening torque
to tighten thread. Excessive tightening may break the thread part or deform
the gasket to cause a fluid leakage. Tightening thread with the tightening
torque lower than these limits may cause a loosened thread or a fluid leakage.
● Table: Recommended tightening torque
(hexagonal-column) (knurling)
Thread type Thread size
Tightening torque
Thread type Thread size
Tightening torque
Metric thread
M3 ×0.5 0.7N・m
Metric thread
M5 ×0.8 1/6 turns
after hand
tightening
M5 ×0.8 1 ~1.5N・m M6 ×1
M6 ×1 2 ~2.7N・mM10 ×1
Taper pipe thread
R1/8 7 ~9N・mParallel pipe
thread
G3/8
1/2~1 turns after
hand tightening
R1/4 12 ~14N・m G1/2
R3/8 22 ~24N・m
R1/2 28 ~30N・m
Unified thread No.10-32UNF 1. 5 ~1.9N・m
National pipe
thread taper
1/16-28NPT 7 ~9N・m
1/8-27NPT 7 ~9N・m
1/4-18NPT 12 ~14N・m
3/8-18NPT 22 ~24N・m
1/2-14NPT 28 ~30N・m
Parallel pipe
thread
G3/8
After hand tightening
1/2~1 turns
G1/2
3. Instructions for removing Controller
① When removing controllers, use proper tools to loosen a hexagonal-column or
a knurling.
② Remove the sealant stuck on the mating equipment. The remained sealant
may get into the peripheral equipment and cause malfunctions.
4. Fixed Orifice Joint Series and Speed Controller Constant Flow Series have
deviation of flow rate. Contact us, in case a very accurate amount of flow rate
is required.
5. If PISCO products generate heat by an adiabatic compression, total
temperature including the heat from the product must be controlled within the
range of the specification.
This manual suits for next models
32
Table of contents
Other PISCO Control Unit manuals
Popular Control Unit manuals by other brands

Optical Systems Design
Optical Systems Design OSD361 Operator's manual

Farfisa
Farfisa Alba AB3G Get started

Bristan
Bristan OP TS1503 EL C Installation instructions and user guide

CKD
CKD MN3GA1R-T6G1 instruction manual

SCHUNK
SCHUNK LDH Series Assembly and operating manual

Grundfos
Grundfos ALPHA 15-55 SUC HWR-D Comfort Installation and operating instructions