PMS HT329M1 User manual

Model
NO.
D
HT-329MKL1)
D
HT-329M2(L2)
HT-329M3(L3)
DHT-329M4(L4)

HT329M1~M4(L1~L4)
LCD
S c r e e n
Mini
Wireless
Digital
PMS
INDEX
1.
INTRODUCTION
1
2.
CAUTION
2-3
3.
INDICATOR
AND
CONTROLS
4-5
4.
PREPARATION
FORUSE6
5.
STANDARDACCESSORIES
7
6.
TROUBLESHOOTING
8-9
7.
TECHNICALSPECIFICATIONS
10
8.
REFERENCEAPPLICATION
11-12
9.
WARRANTY
13
D
HT329M1(L1)
Q
HT329M2(L2)
D
HT329M3(L3)
D
HT329M4(L4)
A
Before
using
the
instrument,
pleaseread
!\e
rating
instructions
carefully!
INTRODUCTION
What
is
PMS?
PMS
stands
for
Powered MuscleStimulator
ThePMS
unit
isa
batterypowereddevicethattransmits
a
mild
electricimpulsesthroughconductiveself-adhesiveelectrodes.
These impulsespassthrough
the
skin
to
underlying nerve
fibers
and
muscles
to
modify
the
perception
of
pain.
PMS
isa
safe
and
effectivedrugfreemethod
of
reducingpain
that
isinuseby
physicians
andin
painclinics
all
over
the
world.
The
HomeTech
PMS
system
unit
isa
high
quality electric
therapystimulator
that
youcanusein
yourhome.
PaintherapywithPMS.
ThePMS
provided
maybe
effective
in
helping
to
manage particularpain problems.
Its
physiologicalreasonings
are
explained
as
follows:
a.
Gatecontroltheory.
b.
The
endorphin theory.
c.
Nerve
block
theory.
d.
Pumping
effect.
e.
Placebotheory.
No
matterwhatpaintheory
is
applied,
PMSis
bothsafe
and
effective
in
painmanagement
for
manypatientsw i t hpain.

•
Re-use
ofthe
electrode
by
anotherusercouldcause
the
cross-infection
of
skindisease.
•The
device'sshelf-life
is3
years.
•
Thisdevice
is
warranted
fora
period
ofone
yearfrom
the
date
of
purchase
by the
originalbuyer.
•The
productcomplieswith
the
electromagneticcompatibility
requirement
of
EN60601-1-2
as
specified
inEEC
Directive
93/42/EEC
as
amended
by
2007/47/EC.
•
Operation
in
closeproximity
(
e.g.
1m) to
shortwave
or
microwavetherapy equipment
may
produce instability
in
the
stimulator
output.(IEC601-2-10).
•
Don'tapply
the
electrode
padto
broken
skin.
•
Don't abruptlystop
or
reset
the
device.
Itmay
cause
the
userdiscomfort.
•
Don'tre-use
too
manytimes,
if
the
electrode
has
deteriorated.
The
user
may
feel
irritation, hotness
orno
effect.
•
PMS
should
notbe
used
inthe
presence
of
cardiac
pace
m a k e
rsorduring
pregnancy.
CAUTION
I-
»
Keep
out
ofthe
reach
of
children.
•
The
contactperiod
is
within
30
min
onthe
samepart
of
patient'sbody
for
eachusage,
butthe
contactperiod
can
be
adjusted
bythe
physician
or
therapist.
'
Don't
stimulate
over
carotid
sinus
nerves
or
around
t h e
mouth
region.
1
Always
usethe
specifiedaccessories
inthe
manual.
The
useof
other parts
not
approved
bythe
manufacturer
may
causeharm.
1
For
serviceinformationlike
circuit
diagram,
partslistetc.,
please
contact
the
distributers.
>
To
clean
the
unit
apply
with
water
or
alcohol
after treatment.
1
Clean
anddrythe
area
to
which
the
electrodes
aretobe
applied
with
water
or
alcohol prior
to
application
ofthe
electrode.

I-
HT329M1(L1)
s
LCD
Screen
On/RaiseSwitch
L
SnapConnector
-Battery
Housing
HT329M2(L2)
LCD
Screen
L
Snap
Connector
-
Battery Housing
3
INDICATORANDCONTROLS
HT329M3(L3)
-Snap
Connector
BatteryHousing
LCD
Screen
On/Raise
Switch
HT329M4(L4)
L
SnapConnector
-
BatteryHousing
LCD
Screen
On/RaiseSwitch

PREPARATION
FOR
USE
1.
Insert
3V
battery,makingsure
itis
positionedcorrectly.
Connect
to
thepadand
place
onthe
skinarea.
2.
Touch
the
rightbutton
to
turn
on
unit
and
raisedensity
level
or
touch
the
left
button
to
lower
the
densitylevel
and
turn
off
the
unit.
3.
Turn
onthe
unit.
TheLCD
screendisplaywillshow
P1
(touch
modebutton
to
changeprogram
to
P2...PO,
there
areten
programs).
4.
When
the
program
has
beenchanged,
the
densitylevelw ill
return
to
"0".
To
raise
the
density,simplypress
the
right
buttonagain.
5.
Touching
the
right
or
leftbuttonwillactivate
the
density
function
andtheLCD
display
the
density level.After
10
seconds
theLCD
w i l l
display
the
number
of
minutes
that
the
unit
ison
for,
the
density
andthe
modeevery
3
seconds.
6.
The
unit
works
fora
period
of30
minutes
and
then
will
automaticallyturnoff.
7.
If
the
densitylevelremains
at
0
f or
more
than
3
minutes,the
unit
will
automatically
switch
off.
8.
The
modebuttonwillfastforwardwhenpressed,
the
density
button
will
not.
5
STANDARD
ACCESSORIES
The
Electric
Stimulator
Kit
have
3
different
Contents:
1.)
Electrode contains
:
a.
ElectricalStimulator
X1
b.
DualpolesSelfAdhering
PadX1
d.
OperatingManual
X1
e.
3V(CR2025)Battery
X1
g.
PackingPlasticCase
x1
2.)
Slim belt
set
contains
:
a.
ElectricalStimulator
X1
b.
Conductiveslim belt
X1
c.
Conductive
gel
X1
d.
Elastic
Strap
L
X1
e.
ElasticStrap
S X1
f.
OperatingManual
X1
g.
3V(CR2025)
Battery
X1
h.
PackingPlasticCase
X1
3.)
Electrode
&
Slim
belt
set
contains
:
a.
ElectricalStimulator
X1
b.
Conductiveslimbelt
X1
c.
Conductive
gelX1
d.
Elastic
Strap
L X1
e.
Elastic
StrapS
X1
f.
Dualpoles Self Adhering
PadX1
g.
Operating Manual
X1
h.3V(CR2025)
Battery
X1
I.
PackingPlasticCase
X1

6
TROUBLESHOOTING
Problem
Nostimula-
tionfelt
Intermittent
stimulation
Not
powerful
enough
Surgesof
power
Possible
Cause
•
Dead battery
•
Battery
in
b a c k w a r d s
•
Lead-off
•
Brokenleadwire
•
Very
dry
electrode
•
Defectiveunit
•
Loose
connection
unit
or
electrode
•
Brokenleadwire
•
Electrode
too
dry
or
worn
out
•
Batteryrunning
low
•
Electrodes
resistance
too
high
•
Impropermode
choice
•
Electrode
peeling
lose
from
skin
Corrective
Action
•
Replacewithfresh
battery
•
Remove
and
insert
correctly
•
Pullouttheunused
lead
plug
from
unit
•
Replacecord
set
w i t h
anothertocheckfor
brokenwire
•
Re-apply electrodes
•
contactdealer
•
Reconnect,
making
surecontact
is
secure
•
Replacecord
set
w i t h
anothertocheckfor
brokenwire
•
Re-apply electrodes
•
Replacebattery
•
Uselowimpedance
electrodes
•
Proper operation
functionmode,push
functionbutton
for
anothermode
•
Replaceelectrode
if
necessary
6
TROUBLESHOOTING
I-
Problem
Stimulation
weakness
minutes
after
start
Unwanted
muscle
twitches
occur
Stimulation
strong,
but
ineffective
Possible
Cause
•
Normal
adaptation
process
•Amplitude
too
high
•
Improper
electrode
placement
Corrective
Action
•
Increase
amplitude
•
Push
function
button
for
anothermode
•
Decreaseamplitude
•
Pushfunctionbutton
for
anothermode
•
Reposition
electrodes;
consult
your
clinician
•
Push
function
button
for
anothermode
If,
afterusingthisguide,
the
unitdoes
not
operateproperly,
theun
i t
should
be
serviced.
Pleasecall
yourdealer
for
instruction.
Stepl
step2
stepS

Dimensions
:
53x30x1
Omm
[HT329MKLD)
54dia.
x10mm
(HT329M2(L2))
54
x
35
x
10mm
[HT329M3(L3)1
54x40
x
10mm
[HT329M4(L4)J
Weight:
Lessthan30gm(batteryincluded)
Power Supply
:3V
battery(CR2025)
x 1
Piece
Channels
Isolation
: One
channeloutput
by
studconnector
Output
Current:
0-90mApeak
to
peak currentinto
500ohm
load
Density
:
Change
of
15
stepspulseamplitude
Timer:
30
minutesbackward
to
auto
off
WaveForm
:
Dualphasesquarewave
LCD
Screen
:
Exchange
display;
mode
;
timer;
density
ProgramMode
: P1
...P5
PMS
program, each
cycle
SOsec.,
7
cycles.
P6...PO
PMS
program,eachcycle
1min.,
7
cycles,contractiontime
(on
time)
2 or4
sec.
relaxationtime(offtime)
2 or4
sec.
^\step
mode\rat&\I
P2
P3
P4
P5
^-""
P6
P7
P8
P9
PO
1
30sec.
2
5
10
15
30
1
min.
2
8
30
36
6
2
SOsec.
4
8
15
25
46
1
min.
5
15
46
64
46
3
SOsec
2
5
10
15
86
1
min.
2
10
10
46
8
4
SOsec.
6
10
25
30
25
1
min.
6
8
36
36
64
5
SOsec.
2
8
10
15
76
1
min.
4
10
10
46
10
6
SOsec
4
5
25
30
30
1
min.
5
8
30
78
78
7
SOsec
6
8
15
25
64
1
min.
6
15
10
64
30
on
time/
/
/
/
/
/
2/2
4/4
2/2
4/4
2/4
;
All
data
is±
10%
STIFF
SHOULDER
AND
NECK.SORE SHOULDER
PARALYSIS
OF
BODY
61
WRISTNERVE,BACK
PAIN,
SCIATICNERVEPAIN
CHRONIC
RHEUMATISM; ROUGH
SKIN;
BLISTEREDSKIN

8
REFERENCE
APPLICATION
SKINNY;OBESITY
FACIAL
NERVEPAIN
;
INSOMNIA
;
NEURASTHEN1ASLEEPLESS
MENSTRUATION
PAIN
AND
IRREGULARMENSTRUATION
Another
Clinical
Uses:
•a
s i n g l e
area
toner
•
musclespasmreduction
•
tired muscle
•
nerveblock
;
reduction
•
cramp
•
postinjectionscleroma
•
scarhypertrophy
•
stiff
neck
•
tenniselbow
•
arthritis
•
headache
•
insomnia
•
intercostalneuralgia
•
paraplegia
•
enuresis
•
beautycare
etc.
•§-See
yourphysician
ifyou
have
any
problems.
9)
WARRANTY
SERVICECARD
MODEL:
TEL:
SERIAL
NO:
ADDRESS:
DATE
P U R C H A S E D :
PURCHASED
F R O M
:
OWNER'S
NAME
:
C€
0434
Distributed
by:
13 i
This manual suits for next models
7
Table of contents