Politec SANDOR HYBRID SMA User manual

Technical
manual

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
2
INDEX
1
MAIN COMPONENTS
Pag. 3
2
MOUNTING SAMPLES
Pag. 4
MOUNTING WITH BRACKETS
Pag. 5
3
INSTALLATION SAMPLES
Pag. 6
4
WIRING
Pag. 7
5
CONFIGURATION OF THE OPTICALS
Pag. 8
OPTICAL TX
Pag. 8
OPTICAL RX
Pag. 9
6
SANDOR WS SMA TX MOTHER BOARD
Pag. 10
7
SANDOR WS SMA RX MOTHER BOARD
Pag. 11
8
SETTINGS & FUNCTIONS
Pag. 12
DIP SWITCHES
Pag. 12
9
COLOUMN ALIGNMENT
Pag. 13
10
CALIBRATION WITH SMA SYSTEM
Pag. 14
11
PARALLEL BEAMS CALIBRATION
Pag. 18
12
ALARM SENSITIVITY ADJUSTMENT
Pag. 19
13
TECHNICAL CHARACTERISTICS
Pag. 20
Installation recommendation
Verify that the beam tower is fully watertight once the cover and end caps have been correctly filled at the
end of the installation.
Use the cable glands supplied on the tower for all cabling must pass through the lower end cap using the
cable glands supplied. The missed used of proper accessories decrease the IP grade protection of the
tower.
Avoid any type of obstruction between the transmitter and receiver.
Avoid installing the receivers beams in a position where direct sunlight, at the same angle as the receivers
beams, can enter directly into optics especially at sunset and sunrise
Do not install multiple beams where the transmitter beam can interfere with other receiver beams. It is
always better place either transmitter or receivers back to back.

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
3
1.MAIN COMPONENTS
N°
Description
1
Aluminium profile
2
IR cover
3
Caps
4
Opticals TX & RX
5
Terminals card
6
Mother board
7
Battery 3.6 V 19 Ah
8
Wireless trasmitter position
9
Power supply 12Vdc
10
Thermostat board
11
Power supply board 3,6 V
1
2
3
4
11
6
7
8
10
9
5

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
4
2.MOUNTING SAMPLES
Pole
mounting
with
SAN/PL
Wall
mounting
with
SAN/SD
Wall
mounting
with
SAN/PL

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
5
MOUNTING WITH BRACKETS
N.B.: we recommend the use of the brackets SAN / PL on the wall when you place the protection of
gates (windows, doors, ...) along the wall to avoid small obstacles (hinges, edges of window sills, ...)
that could create signal attenuation.
Insert the bracket
on the back
Wall mounting with
SAN/PL
Pole
mounting
with
SAN/PL
Diameter pole
max 48 mm
Wall mounting with
SAN/SD

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
6
3.INSTALLATION SAMPLES
Standard perimeter protection:
In the case of overlapped barriers:
RX
TX4
TX3
TX2
TX1
TX
RX
TX
RX4
RX3
RX2
RX1
RX4
RX3
RX2
RX1
TX4
TX3
TX2
TX1

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
7
4.WIRING
220 Vac
+
-
+
-
12 Vdc
THERMOSTAT
BOARD
POWER SUPPLY
BOARD 3.6V
MOTHERBOARD
TX or RX

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
8
5.CONFIGURATION OF THE OPTICALS
OPTICAL TX
NB: The address settings as per default .
1
2
3
4
5
6
1
2
3
4
5
6
TX1
TX2
TX3
TX4
TX5
TX6
TEST LED
TAMPER
TEST
BUTTON

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
9
OPTICAL RX
1
2
3
4
5
6
1
2
3
4
5
6
RX1
RX2
RX3
RX4
RX5
RX6
NB: The address settings as per default .
TAMPER
LOW
SIGNAL
LED
TEST LED
TEST
BUTTON

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
10
6. SANDOR WS SMA TX MOTHER BOARD
N.B.: When the motherboard is supplied the LED ON will flash.
LED ON
TAMPER
BATTERY
CONNECTION
3,6 V –19 Ah

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
11
7.SANDOR WS SMA RX MOTHER BOARD
N.B.: When the motherboard is supplied by battery the TEST LED will flash
- +
LED TEST
BATTERY
CONNECTION
3,6 V –19 Ah
3,6 V
3,0 V
TAMPER
ALARM
TAMPER
SUPPLY
INTERVENTION
DELAY
ADJUSTING
BATTERY LOW (BL)
SIGNAL LOW (SL)
AND FOR REMOTE
(AND)
DIP SWITCH
ANTIMASK POUTPUT
(AMK)

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
12
8.SETTINGS & FUNCTIONS
DIP SWITCHES
The board has Dip Switches to set different functions:
4 DIP SWITCH TX
1
TEST
In ON position goes in test for alignment. The TEST LED start blinking.
2
/
Not utilized
3
BEAM ON
It puts in test all TX during alignment (DIP 1 ON). Test LED fixed ON.
4
BEAM OFF
It puts OFF all TX during alignment (DIP 1 ON). Test LED fixed ON.
ON
1
2
3
4
5
6
7
8
9
10
Ex.: Function AND 1-2 with 6 beams
10 DIP SWITCHES RX
1
AND
At least 2 optical must be interrupted to give alarm
2
AND 1-2
AND function only for 1st and 2nd beam, usefull in case of growing grass
3
BEAM 3
First 3 RX are active
4
BEAM 4
First 4 RX are active
5
BEAM 5
First 5 RX are active
6
BEAM 6
all RX are active
7
S. LOW
FOG disqualification active
8
A. CRAWL
ON - Anti crawling active. In this condition if the first beam (lower) is interrupted for
more than 2 seconds, it will generate an alarm, independently of its configuration
(i.e. AND)
9
AMK
/
10
TEST
Put in ON activates the test phases

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
13
CONECTOR 8
1
HTR
Not utilized
2
3
ALLARME
NC Alarm relay
4
5
TAMPER
NC Tamper relay
6
7
SUPPLY
Possibility to supply the radio trasmitter with 3,0 or 3,6 V
8
CONNECTOR 4
BL
BATTERY LOW
Low battery indication (negative open collector)
SL
SIGNAL LOW
Fog disqualification (negative open collector)
AN
REMOTE
CONTROL
Giving a positive (3,6 V) the AND function is activated
AMK
ANTIMASK
Segnalazione di mascheramento data dalla chiusura al negativo di un
open collector.
9. COLOUMN ALIGNMENT
For proper alignment once installed barriers orient optical groups of the transmitters and receivers each optical
groups in the direction of others. Adjusting horizontally through the manual movement, and vertically through
the front screws placed above the lenses.
Vertical adjustment
Horizontal adjustment

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
14
10. CALIBRATION WITH SMA SYSTEM
You can improve the calibration through the use of the supplied filter
1) Fold the device by following the folds preset
2) Place the filter in front of the optics TX positioning the two hooks on the pins of the fork optics to
effectively search the signal alignment with critical conditions.
Simply applying the filter only on the TX, no need to repeat the operation RX.

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
15
3) Put the DIP10 in ON on the motherboard to activate the programming mode indicated by the flashing
LED test. During this phase the LED will continue to flash.
4) Start the alignment of the barrier is on activating the transmitter optics TX TEST, pressing the dedicated
button for about 3 seconds until the TEST LED turns orange.
DIP 10
ORANGE
LED
TEST
BUTTON

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
16
5) Turn the TEST on the corresponding optics receiver by pressing the dedicated button for about 3
seconds until the TEST LED turns orange , the Buzzer and LED alignment go ON.
6) Through the TRANSMITTER lens shifts , find the maximum optical alignment based on the BUZZER
and LED (high-brightness) of alignment, the 'increase in the frequency of blinking of the LEDs and the
whistle of the corresponding BUZZER indicate better ALIGNMENT.
7) By a FULL rotation on the horizontal axis of the RECEIVER optics , you make the SCANNING of the
optical signal.
8) Rotating the optical RX find the maximum value of which corresponds to the ALIGNMENT LED
(high-brightness) FIXED and whistle CONTINUOUS of the BUZZER.
PULSANTE
DI TEST
LED
ARANCIONE

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
17
9) Exit the function by repressing the ALIGNMENT TEST button for about 3 seconds on both optics (TX-
RX) ensuring that the orange LED TEST is shown in original condition.
10) When finished, remove the shade that acts as a attenuator, with the certainty of having found the
optimum value.
11) Once the alignment of all the beams is finished, put in OFF the DIP 10 on the motherboard to
deactivate the programming mode indicated by the LED turns off.
For the next 30 seconds the barrier will sound continuously in case of alignment not effective or
interruption of a beam; correct the orientation of the columns so that the buzzer emits no longer any
sound.
N.B.: SE IL LED DI TEST CONTINUA A LAMPEGGIARE VELOCEMENTE DURANTE IL
NORMALE FUNZIONAMENTO SIGNIFICA CHE ESISTE UNA FONTE DI DISTURBO
INFRAROSSO ( ALTRA BARRIERA, FOTOCELLULA CANCELLO, …) CHE NON
PERMETTE IL CORRETTO FUNZIONAMENTO DELLA BARRIERA.
PULSANTE
DI TEST
LED
ARANCIONE

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
18
11. PARALLEL BEAMS CALIBRATION
Put TEST optics TX1 and RX1 and proceed with the calibration
as previously explained.
Put TEST optics TX2 and RX2 and proceed with the calibration
as previously explained.
Put TEST optics TX3 and RX3 and proceed with the calibration
as previously explained.
Put TEST optics TX4 and RX4 and proceed with the calibration
as previously explained.
N.B.: During the alignment phase of a transmitter the other TX are switched off automatically.

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
19
12. ALARM SENSITIVITY ADJUSTMENT
You can set the barrier for HIGH sensitivity as crossing fast (running) or LOW as slow ( walking).
By adjusting the potentiometer counterclockwise to increase the alarm delay up to 500ms. In this
condition ensures the alarm of a person walking through the barrier, with the advantage of excluding the
possibility of any false alarms such animals.
Adjusting the potentiometer clockwise to decrease the alarm delay up to 50ms. In this condition ensures
the alarm of a person crossing the barrier running at maximum speed.

POLITEC s.r.l. | Manual Sandor HYBRID SMA –Ver. 1.2
20
13. TECHNICAL CHARACTERISTICS
MAX RANGE INDOOR
200 m
MAX RANGE OUTDOOR
100m
ALIGNEMENT TECHNOLOGY
SMA tecnology
SYNCHRONIZATION
Optical
ADJUSTMENT
20° vertical
180° horizontal
PHOTOBEAMS
Pulsed 950nM beams
SETTABLE OPERATION MODE
OR - AND RANDOM
SETTABLE BEAMS EXCLUSION
Yes
ANTI-CRAWLING FUNCTION (FIRST
BEAM LOW)
Yes
COLUMN SUPPLY
BATTERY 3,6 V 19 Ah
OUTPUT
Relè con contatti liberi NC/NO (su RX)
TAMPER OUTPUT
Free contact relay (NC NO) on RX (also
for TX tamper)
OUTPUT DISQUALIFICATION
Output OC
OUTPUT BARREY LOW
Output OC
OPERATING TEMP.
–25°C / +65°C
PROTECTION GRADE
IP65
DIMENSIONE PROFILO LXPXH
60 mm x 60 mm x (da 600 mm a 4000 mm)
N°
Beams
Battery life
Single battery
Double
batteries
2
42 months
/
4
36 months
/
6
24 months
48 months
This manual suits for next models
1
Table of contents
Other Politec Security Sensor manuals
Popular Security Sensor manuals by other brands

ESYLUX
ESYLUX EP10425806 installation instructions

AJAX
AJAX MotionProtect Curtain user manual

Knauer
Knauer BlueShadow 50D Service instructions

Heitronic
Heitronic 42198 Installation and operating instructions

daviteq
daviteq WS433-ATH user guide

Emerson
Emerson Machinery Health PR 9268 Series installation guide